Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Evaluation of 134 Ce/ 134 La as a PET Imaging Theranostic Pair for 225 Ac α-Radiotherapeutics

225 Ac-targeted α-radiotherapy is a promising approach to treating malignancies, including prostate cancer. However, α-emitting isotopes are difficult to image because of low administered activities and a low fraction of suitable γ-emissions. The in vivo generator 134 Ce/ 134 La has been proposed as a potential PET imaging surrogate for the therapeutic nuclides 225 Ac and 227 Th. In this report, we detail efficient radiolabeling methods using the 225 Ac-chelators DOTA and MACROPA. These methods were applied to radiolabeling of prostate cancer imaging agents, including PSMA-617 and MACROPA-PEG 4 -YS5, for evaluation of their in vivo pharmacokinetic characteristics and comparison to the corresponding 225 Ac analogs. Methods: Radiolabeling was performed by mixing DOTA/MACROPA chelates with 134 Ce/ 134 La in NH 4 OAc, pH 8.0, at room temperature, and radiochemical yields were monitored by radio–thin-layer chromatography. In vivo biodistributions of 134 Ce-DOTA/MACROPA.NH 2 complexes were assayed through dynamic small-animal PET/CT imaging and ex vivo biodistribution studies over 1 h in healthy C57BL/6 mice, compared with free 134 CeCl 3 . In vivo, preclinical imaging of 134 Ce-PSMA-617 and 134 Ce-MACROPA-PEG 4 -YS5 was performed on 22Rv1 tumor–bearing male nu/nu-mice. Ex vivo biodistribution was performed for 134 Ce/ 225 Ac-MACROPA-PEG 4 -YS5 conjugates. Results: 134 Ce-MACROPA.NH 2 demonstrated near-quantitative labeling with 1:1 ligand-to-metal ratios at room temperature, whereas a 10:1 ligand-to-metal ratio and elevated temperatures were required for DOTA. Rapid urinary excretion and low liver and bone uptake were seen for 134 Ce/ 225 Ac-DOTA/MACROPA. NH 2 conjugates in comparison to free 134 CeCl 3 confirmed high in vivo stability. An interesting observation during the radiolabeling of tumor-targeting vectors PSMA-617 and MACROPA-PEG 4 -YS5—that the daughter 134 La was expelled from the chelate after the decay of parent 134 Ce—was confirmed through radio–thin-layer chromatography and reverse-phase high-performance liquid chromatography. Both conjugates, 134 Ce-PSMA-617 and 134 Ce-MACROPA-PEG 4 -YS5, displayed tumor uptake in 22Rv1 tumor–bearing mice. The ex vivo biodistribution of 134 Ce-MACROPA.NH 2 , 134 Ce-DOTA and 134 Ce-MACROPA-PEG 4 -YS5 corroborated well with the respective 225 Ac-conjugates. Conclusion: These results demonstrate the PET imaging potential for 134 Ce/ 134 La-labeled small-molecule and antibody agents. The similar 225 Ac and 134 Ce/ 134 La-chemical and pharmacokinetic characteristics suggest that the 134 Ce/ 134 La pair may act as a PET imaging surrogate for 225 Ac-based radioligand therapies.

07 ISOTOPE AND RADIATION SOURCES↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

“Production of High Specific Activity 155 Tb, 161 Tb and 203 Pb for Research and Clinical Applications: Effective Target Design, Target Material Recycling and Radioisotope Separation”

Radioisotopes are essential for the development and application of radiopharmaceuticals that target specific diseases, such as cancer, offering unique potential for precision medicine. The growing demand for theranostic radioisotopes underscores their critical role in personalized medicine, where they enhance diagnostic imaging, minimize patient radiation exposure, and improve targeted tissue uptake, particularly in receptor- and antigen-directed therapies. The theranostic pair terbium-155 (diagnostic) and terbium-161 (therapeutic) holds significant promise for advancing individualized, targeted, and dosimetry-driven radiotherapies. However, the United States currently lacks routine and reliable production of these isotopes. This project made significant progress toward addressing this supply issue by developing production and separation methods for terbium-155 and terbium-161 while also training the next generation of the nuclear and radiochemistry workforce. This grant also strengthened collaboration between scientists at the University of Washington, the University of Missouri and Brookhaven National Laboratory. The research effort focused on evaluating target preparation methods, optimizing irradiation parameters, and refining isolation processes. In addition, the project provided extensive hands-on training to graduate students and postdoctoral fellows, equipping them with expertise in radioisotope production technologies and fostering the growth of the nuclear science workforce.

07 ISOTOPE AND RADIATION SOURCES↗

Optical Imaging on Z LDRD: Design and Development of Self-Emission and Debris Imagers

We present an overview of the design and development of optical self-emission and debris imaging diagnostics for the Z Machine at Sandia National Laboratories. These diagnostics were designed and implemented to address several gaps in our understanding of visibly emitting phenomenon on Z and the post-shot debris environment. Optical emission arises from plasmas that form on the transmission line that delivers energy to Z loads and on the Z targets themselves; however, the dynamics of these plasmas are difficult to assess without imaging data. Addressing this, we developed a new optical imager called SEGOI (Self-Emission Gated Optical Imager) that leverages the eight gated optical imagers and two streak cameras of the Z Line VISAR system. SEGOI is a low cost, side-on imager with a 1 cm field of view and 30-50 µm spatial resolution, sensitive to green light (540-600 nm). This report outlines the design considerations and development of this diagnostic and presents an overview of the first diagnostic data acquired from four experimental campaigns. SEGOI was fielded on power flow experiments to image plasmas forming on and between transmission lines, on an inertial confinement fusion experiment called the Dynamic Screw Pinch to image low density plasmas forming on return current posts, on an experiment designed to measure the magneto Rayleigh-Taylor instability to image the instability bubble trajectory and self-emission structures, and finally on a Magnetized Liner Inertial Fusion (MagLIF) experiment to image the emission from the target. The second diagnostic developed, called DINGOZ (Debris ImagiNG on Z), was designed to improve our understanding of the post-shot debris environment. DINGOZ is an airtight enclosure that houses electronics and batteries to operate a high-speed (10-400 kfps) camera in the Z Machine center section. We report on the design considerations of this new diagnostic and present the first high-speed imaging data of the post-shot debris environment on Z.

42 ENGINEERING↗

Excitation spectral microscopy for highly multiplexed fluorescence imaging and quantitative biosensing

The multiplexing capability of fluorescence microscopy is severely limited by the broad fluorescence spectral width. Spectral imaging offers potential solutions, yet typical approaches to disperse the local emission spectra notably impede the attainable throughput. Here we show that using a single, fixed fluorescence emission detection band, through frame-synchronized fast scanning of the excitation wavelength from a white lamp via an acousto-optic tunable filter, up to six subcellular targets, labeled by common fluorophores of substantial spectral overlap, can be simultaneously imaged in live cells with low (~1%) crosstalks and high temporal resolutions (down to ~10 ms). The demonstrated capability to quantify the abundances of different fluorophores in the same sample through unmixing the excitation spectra next enables us to devise novel, quantitative imaging schemes for both bi-state and Förster resonance energy transfer fluorescent biosensors in live cells. We thus achieve high sensitivities and spatiotemporal resolutions in quantifying the mitochondrial matrix pH and intracellular macromolecular crowding, and further demonstrate, for the first time, the multiplexing of absolute pH imaging with three additional target organelles/proteins to elucidate the complex, Parkin-mediated mitophagy pathway. Together, excitation spectral microscopy provides exceptional opportunities for highly multiplexed fluorescence imaging. The prospect of acquiring fast spectral images without the need for fluorescence dispersion or care for the spectral response of the detector offers tremendous potential.

59 BASIC BIOLOGICAL SCIENCES↗

Current Status of Radiopharmaceutical Therapy

In radiopharmaceutical therapy (RPT), a radionuclide is systemically or locally delivered with the goal of targeting and delivering radiation to cancer cells while minimizing radiation exposure to untargeted cells. Examples of current RPTs include thyroid ablation with the administration of {sup 131}I, treatment of liver cancer with {sup 90}Y microspheres, the treatment of bony metastases with {sup 223}Ra, and the treatment of neuroendocrine tumors with {sup 177}Lu-DOTATATE. New RPTs are being developed where radionuclides are incorporated into systemic targeted therapies. To assure that RPT is appropriately implemented, advances in targeting need to be matched with advances in quantitative imaging and dosimetry methods. Currently, radiopharmaceutical therapy is administered by intravenous or locoregional injection, and the treatment planning has typically been implemented like chemotherapy, where the activity administered is either fixed or based on a patient’s body weight or body surface area. RPT pharmacokinetics are measurable by quantitative imaging and are known to vary across patients, both in tumors and normal tissues. Therefore, fixed or weight-based activity prescriptions are not currently optimized to deliver a cytotoxic dose to targets while remaining within the tolerance dose of organs at risk. Methods that provide dose estimates to individual patients rather than to reference geometries are needed to assess and adjust the injected RPT dose. Accurate doses to targets and organs at risk will benefit the individual patients and decrease uncertainties in clinical trials. Imaging can be used to measure activity distribution in vivo, and this information can be used to determine patient-specific treatment plans where the dose to the targets and organs at risk can be calculated. The development and adoption of imaging-based dosimetry methods is particularly beneficial in early clinical trials. In this work we discuss dosimetric accuracy needs in modern radiation oncology, uncertainties in the dosimetry in RPT, and best approaches for imaging and dosimetry of internal radionuclide therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Low Can You Go? Using Synthetic 3D Imagery to Drastically Reduce Real-World Training Data for Object Detection

Deep convolutional neural networks (DCNNs) currently provide state-of-the-art performance on image classification and object detection tasks, and there are many global security mission areas where such models could be extremely useful. Crucially, the success of these models is driven in large part by the widespread availability of high-quality open source data sets such as Image Net, Common Objects in Context (COCO), and KITTI, which contain millions of images with thousands of unique labels. However, global security relevant objects-of-interest can be difficult to obtain: relevant events are low frequency and high consequence; the content of relevant images is sensitive; and adversaries and proliferators seek to obscure their activities. For these cases where exemplar data is hard to come-by, even fine-tuning an existing model with available data can be effectively impossible. Recent work demonstrated that models can be trained using a combination of real-world and synthetic images generated from 3D representations; that such models can exceed the performance of models trained using real-world data alone; and that the generated images need not be perfectly realistic (Tremblay, et al., 2018). However, this approach still required hundreds to thousands of real-world images for training and fine tuning, which for sparse, global security-relevant datasets can be an unrealistic hurdle. In this research, we validate the performance and behavior of DCNN models as we drive the number of real-world images used for training object detection tasks down to a minimal set. We perform multiple experiments to identify the best approach to train DCNNs from an extremely small set of real-world images. In doing so, we: Develop state-of-the-art, parameterized 3D models based on real-world images and sample from their parameters to increase the variance in synthetic image training data; Use machine learning explainability techniques to highlight and correct through targeted training the biases that result from training using completely synthetic images; and Validate our results by comparing the performance of the models trained on synthetic data to one another, and to a control model created by fine-tuning an existing ImageNet-trained model with a limited number (hundreds) of real-world images.

97 MATHEMATICS AND COMPUTING↗

Radiofluorination of oxazole-carboxamides for preclinical PET neuroimaging of GSK-3

Glycogen synthase kinase 3 (GSK-3) is an enzyme that is dysregulated in oncology neurodegeneration, neuroinflammation and several mental health illnesses. As such, GSK-3 is a long-sought after target for positron emission tomography (PET) imaging and therapeutic intervention. Herein, we report on the development and radiofluorination of two oxazole-4- carboxamides, including one bearing a non-activated aromatic ring. Both compounds demonstrated excellent selectivity in a kinase screen and inhibit GSK-3 with high affinity. [ 18 F]OCM-49 was synthesized from [ 18 F]fluoride using a copper-mediated reaction of an aryl boronic acid precursor, while [ 18 F]OCM-50 used a trimethylammonium triflate precursor, and both radiotracers were translated for preclinical PET imaging in rodents. Due to superior radiochemical yields and brain uptake (peak standardized uptake value of ~2.0), [ 18 F]OCM-50 was further evaluated in non-human primate and also showed good brain uptake and rapid clearance. Finally, further studies to consider clinical translation of both radiotracers are underway.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First-principles simulation of light-ion microscopy of graphene

The extreme sensitivity of 2D materials to defects and nanostructure requires precise imaging techniques to verify presence of desirable and absence of undesirable features in the atomic geometry. Helium-ion beams have emerged as a promising materials imaging tool, achieving up to 20 times higher resolution and 10 times larger depth-of-field than conventional or environmental scanning electron microscopes. Here, we offer first-principles theoretical insights to advance ion-beam imaging of atomically thin materials by performing real-time time-dependent density functional theory simulations of single impacts of 10–200 keV light ions in free-standing graphene. Here we predict that detecting electrons emitted from the back of the material (the side from which the ion exits) would result in up to three times higher signal and up to five times higher contrast images, making 2D materials especially compelling targets for ion-beam microscopy. This predicted superiority of exit-side emission likely arises from anisotropic kinetic emission. The charge induced in the graphene equilibrates on a sub-fs time scale, leading to only slight disturbances in the carbon lattice that are unlikely to damage the atomic structure for any of the beam parameters investigated here.

36 MATERIALS SCIENCE↗

2017 Puerto Rico G-LiHT Metadata

This data package contains metadata for data acquired for sample transects across Puerto Rico using NASA Goddard's Lidar, Hyperspectral, and Thermal (G-LiHT) Airborne Imager in March 2017. Flights specifically targeted sites with coincident field data collection for NGEE-Tropics, existing forest inventory plots from the USDA-Forest Service Forest Inventory & Analysis (FIA) program and university collaborators, and other research installations (e.g., NEON).

54 ENVIRONMENTAL SCIENCES↗

Biologically Inspired Interception on an Unmanned System

Borrowing from nature, neural-inspired interception algorithms were implemented onboard a vehicle. To maximize success, work was conducted in parallel within a simulated environment and on physical hardware. The intercept vehicle used only optical imaging to detect and track the target. A successful outcome is the proof-of-concept demonstration of a neural-inspired algorithm autonomously guiding a vehicle to intercept a moving target. This work tried to establish the key parameters for the intercept algorithm (sensors and vehicle) and expand the knowledge and capabilities of implementing neural-inspired algorithms in simulation and on hardware.

42 ENGINEERING↗

Numerical Analysis and Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) simulations for both 300 g/s and 400 g/s are performed on the NMR target to analyze the helium flow through the NMR system. The pressure drop, the mass flow rate through each of the disc and window channels and the force applied on the first disc are some of the quantities estimated using CFD. These results will be combined with Monte Carlo N-Particle (MCNP) estimates of heat flux into the system from the electron beam to perform conjugate heat transfer analysis (CHT). The experiments presented in this report focus on the effect of the flow induced vibrations from helium flowing through the coolant gaps between the discs. There is concern that the flow induced vibrations may lead to excessive mass loss of the enriched Mo-100 discs, and the goal would be to mitigate the mass loss. This work presents benchtop tests of flow through a subset of the target stack which involves high speed imaging and displacement measurements used to estimate disc vibration, as well as mass loss.

42 ENGINEERING↗

The SAGA Survey. II. Building a Statistical Sample of Satellite Systems around Milky Way–like Galaxies

In this work, we present the Stage II results from the ongoing Satellites Around Galactic Analogs (SAGA) Survey. Upon completion, the SAGA Survey will spectroscopically identify satellite galaxies brighter than M r,o = -12.3 around 100 Milky Way (MW) analogs at z ~ 0.01. In Stage II, we have more than quadrupled the sample size of Stage I, delivering results from 127 satellites around 36 MW analogs with an improved target selection strategy and deep photometric imaging catalogs from the Dark Energy Survey and the Legacy Surveys. We have obtained 25,372 galaxy redshifts, peaking around z = 0.2. These data significantly increase spectroscopic coverage for very low redshift objects in 17 < r o < 20.75 around SAGA hosts, creating a unique data set that places the Local Group in a wider context. The number of confirmed satellites per system ranges from zero to nine and correlates with host galaxy and brightest satellite luminosities. We find that the number and luminosities of MW satellites are consistent with being drawn from the same underlying distribution as SAGA systems. The majority of confirmed SAGA satellites are star-forming, and the quenched fraction increases as satellite stellar mass and projected radius from the host galaxy decrease. Overall, the satellite quenched fraction among SAGA systems is lower than that in the Local Group. We compare the luminosity functions and radial distributions of SAGA satellites with theoretical predictions based on cold dark matter simulations and an empirical galaxy–halo connection model and find that the results are broadly in agreement.

79 ASTRONOMY AND ASTROPHYSICS↗

Using Fiducial Markers for Pose Estimation of an OSWEC in a Wave Tank: Preprint

In this study, we consider a novel method of sensing the motion of a wave energy converter during testing in a wave flume under the influence of incoming waves. The wave energy converter considered in our research is an oscillating surge wave energy converter, which is a hinged paddle that responds to incoming waves. Motion sensing is normally done with inertial sensors, which can hinder the motion due to suspended cables that carry power and transmit signals. Our proposed method is contactless and can be implemented economically. A camera is used to record different marker patterns affixed to the moving paddle and the motion deduced by pose estimation algorithms. Fiducial markers are commonly used for robot localization and in augmented reality. There are many types of fiducial markers, including ArUco-type markers which are accurate, fast and robust. The system consists of markers attached to the paddle element and recorded using a machine vision camera. A pose estimation algorithm is then applied to the detected markers to estimate the tilt of the paddle. In this work, we examine the challenges of image acquisition and calibration for underwater targets, compare the motion obtained by this new system with a calibrated tilt sensor and identify areas where the new system may be superior.

computer vision↗

PET Imaging Agents (FES, FFNP, and FDHT) for Estrogen, Androgen, and Progesterone Receptors to Improve Management of Breast and Prostate Cancers by Functional Imaging

Many breast and prostate cancers are driven by the action of steroid hormones on their cognate receptors in primary tumors and in metastases, and endocrine therapies that inhibit hormone production or block the action of these receptors provide clinical benefit to many but not all of these cancer patients. Because it is difficult to predict which individuals will be helped by endocrine therapies and which will not, positron emission tomography (PET) imaging of estrogen receptor (ER) and progesterone receptor (PgR) in breast cancer, and androgen receptor (AR) in prostate cancer can provide useful, often functional, information on the likelihood of endocrine therapy response in individual patients. This review covers our development of three PET imaging agents, 16α-[ 18 F]fluoroestradiol (FES) for ER, 21-[ 18 F]fluoro-furanyl-nor-progesterone (FFNP) for PgR, and 16β-[ 18 F]fluoro-5α-dihydrotestosterone (FDHT) for AR, and the evolution of their clinical use. For these agents, the pathway from concept through development tracks with an emerging understanding of critical performance criteria that is needed for successful PET imaging of these low-abundance receptor targets. Progress in the ongoing evaluation of what they can add to the clinical management of breast and prostate cancers reflects our increased understanding of these diseases and of optimal strategies for predicting the success of clinical endocrine therapies.

60 APPLIED LIFE SCIENCES↗

Single detector laser-induced fluorescence imager and raman spectral instrument

Apparatus include divergence optics removably coupled to receive a probe beam in a first imaging mode to cause the probe beam to diverge before impinging on a first area of a target surface, and to not receive the probe beam in a second imaging mode to cause the probe beam to impinge on a second area of the target surface smaller than the first area, collection optics configured to receive, in response to the probe beam, luminescence light emitted from the first area and spectral light emitted from the second area, and an optical detector coupled to the collection optics, wherein the optical detector includes a luminescence imaging detector portion and a spectral imaging detector portion adjacent to the luminescence imaging detector portion, wherein the luminescence imaging detector portion is configured to receive the luminescence light emitted from the first area and the spectral imaging detector portion is configured to receive the spectral light from the second area.

Gasda, Patrick J.↗