Search NASA⌕ Search

SEARCH · Search NASA

Results for “tariffs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

An integrated assessment of the potential of agricultural and forestry residues for energy production in China

Biomass has been widely recognized as an important energy source with high potential to reduce greenhouse gas emissions while minimizing environmental pollution. In this study, we employ the Global Change Assessment Model to estimate the potential of agricultural and forestry residue biomass for energy production in China. Potential availability of residue biomass as an energy source was analyzed for the 21st century under different climate policy scenarios. Currently, the amount of total annual residue biomass, averaged over 2003-2007, is around 15519PJ in China, consisting of 10818PJ from agriculture residues (70%) and 4701PJ forestry residues (30%). We estimate that 12693PJ of the total biomass is available for energy production, with 66% derived from agricultural residue and 34% from forestry residue. Most of the available residue is from south central China (3347PJ), east China (2862PJ) and south-west China (2229PJ), which combined exceeds 66% of the total national biomass. Under the reference scenario without carbon tax, the potential availability of residue biomass for energy production is projected to be 3380PJ by 2050 and 4108PJ by 2095, respectively. When carbon tax is imposed, biomass availability increases substantially. For the CCS 450ppm scenario, availability of biomass increases to 9002PJ (2050) and 11524PJ (2095), respectively. For the 450ppm scenario without CCS, 9183 (2050) and 11150PJ (2095) residue biomass, respectively, is projected to be available. Moreover, the implementation of CCS will have a little impact on the supply of residue biomass after 2035. Our results suggest that residue biomass has the potential to be an important component in China's sustainable energy production portfolio. As a low carbon emission energy source, climate change policies that involve carbon tariff and CCS technology promote the use of residue biomass for energy production in a low carbon-constrained world.

bioenergy↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

REopt: A Platform for Energy System Integration and Optimization: Preprint

REopt is NREL's energy planning platform offering concurrent, multi-technology integration and optimization capabilities to help clients meet their cost savings and energy performance goals. The REopt platform provides techno-economic decision-support analysis throughout the energy planning process, from agency-level screening and macro planning to project development to energy asset operation. REopt employs an integrated approach to optimizing a site?s energy costs by considering electricity and thermal consumption, resource availability, complex tariff structures including time-of-use, demand and sell-back rates, incentives, net-metering, and interconnection limits. Formulated as a mixed integer linear program, REopt recommends an optimally-sized mix of conventional and renewable energy, and energy storage technologies; estimates the net present value associated with implementing those technologies; and provides the cost-optimal dispatch strategy for operating them at maximum economic efficiency. The REopt platform can be customized to address a variety of energy optimization scenarios including policy, microgrid, and operational energy applications. This paper presents the REopt techno-economic model along with two examples of recently completed analysis projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Data Driven Pre-cooling Framework for Energy Cost Optimization in Commercial Buildings

Commercial buildings consume significant amount of energy. Facility managers are increasingly grappling with the problem of reducing their buildings’ peak power, overall energy consumption and energy bills. In this paper, we first develop an optimization framework – based on a gray box model for zone thermal dynamics – to determine a pre-cooling strategy that simultaneously shifts the peak power to low energy tariff regimes, and reduces both the peak power and overall energy consumption by exploiting the flexibility in a building’s thermal comfort range. We then evaluate the efficacy of the pre-cooling optimization framework by applying it to building management system data, spanning several days, obtained from a large commercial building located in a tropical region of the world. The results from simulations show that optimal pre-cooling reduces peak power by over 50%, energy consumption by up to 30% and energy bills by up to 37%. Next, to enable ease of use of our framework, we also propose a shortest path based heuristic algorithmfor solving the optimization problemand show that it has comparable erformance with the optimal solution. Finally, we describe an application of the proposed optimization framework for developing countries to reduce the dependency on expensive fossil fuels, which are often used as a source for energy backup.We conclude by highlighting our real world deployment of the optimal pre-cooling framework via a software service on the cloud platform of a major provider. Our pre-cooling methodology, based on the gray box optimization framework, incurs no capital expense and relies on data readily available from a building management system, thus enabling facility managers to take informed decisions for improving the energy and cost footprints of their buildings

Vishwanath, Arun↗

Why Do Electricity Policy and Competitive Markets Fail to Use Advanced PV Systems to Improve Distribution Power Quality?

The increasing pressure for network operators to meet distribution network power quality standards with increasing peak loads, renewable energy targets, and advances in automated distributed power electronics and communications is forcing policy-makers to understand new means to distribute costs and benefits within electricity markets. Discussions surrounding how distributed generation (DG) exhibits active voltage regulation and power factor/reactive power control and other power quality capabilities are complicated by uncertainties of baseline local distribution network power quality and to whom and how costs and benefits of improved electricity infrastructure will be allocated. DG providing ancillary services that dynamically respond to the network characteristics could lead to major network improvements. With proper market structures renewable energy systems could greatly improve power quality on distribution systems with nearly no additional cost to the grid operators. Renewable DG does have variability challenges, though this issue can be overcome with energy storage, forecasting, and advanced inverter functionality. This paper presents real data from a large-scale grid-connected PV array with large-scale storage and explores effective mitigation measures for PV system variability. We discuss useful inverter technical knowledge for policy-makers to mitigate ongoing inflation of electricity network tariff components by new DG interconnection requirements or electricity markets which value power quality and control.

14 SOLAR ENERGY↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Home Energy Saver v3 (website) and APIs

A web-based residential energy calculator with APIs that run two LBNL websites: http://hes.lbl.gov and http://hespro.lbl.gov. Provide customized estimates of residential energy use, energy bills, and CO2 emissions, based on building description information provided by the user. Energy use is estimated by end-use and device, using engineering models developed at LBNL. Space heating and cooling use is based on the DOE-2.1 E building simulation model. Other end-uses (water heating, appliances, lighting, and miscellaneous equipment) are based on engineering models developed by LBNL. Users can estimate their household carbon footprint and compare it to average values for their neighborhood and other regions, displayed using the Google Maps API. Energy bills can be calculated using either average energy price data or actual utility tariffs. The HES software also includes extensive default input for required user inputs. Hardware req.: Multi-platform; Type of files: Source code, installation instructions other; programmer documentation; user manual; electronic format.

Mills, Evan↗

EFFORT (EFFectiveness Of Rate sTructure for enabling demand response)

This tool helps utilities evaluate potential time of use price-plans and find effective hours for price plan on peak periods and the potential price-elastic demand response. An optimization model can be used to find tiered prices for the time of use tariffs and analyze the impact on load profiles, energy consumption, utility, and customer savings. The tool is equipped with an optimization model to determine the energy consumption of electric appliances that can leverage survey data containing information on the number of appliances owned by customers. Lastly, a statistical model can be used to predict system-level load based on exogenous parameters such as weather, time of day, month, type of day, and year. The tool is scripted in Python and uses the Pyomo python optimization language.

Duwadi, Kapil↗

LCOC (Levelized Cost of Light-Duty EV Charging Calculator)

This code was developed to calculate the levelized cost of light-duty electric vehicle (EV) charging (LCOC) for the paper "Levelized Cost of Charging Electric Vehicles in the United States" by Borlaug et al.(https://doi.org/10.1016/j.joule.2020.05.013). The calculation takes inputs from a variety of publicly available data sources (e.g., utility tariffs from the Utility Rate Database; EV charging station locations from the Alternative Fuels Data Center; energy price forecasts from the Energy Information Administration) and produces the current LCOC, considering when, where, and how light-duty EVs are recharged. In addition, the lifetime fuel cost savings (LFCS) calculation estimates the discounted fuel cost savings for a new battery EV (BEV) or plug-in hybrid EV (PHEV) over a 15-year time horizon using state-level gasoline price and LCOC projections.

Borlaug, Brennan↗

A Reverse Logistics Tool For Ev Battery Recycling And Repurposing,

The demand for electric vehicles (EVs) in the United States is projected to rise significantly, with sales expected to reach approximately 4.1 million units by 2030. However, the U.S. remains heavily reliant on imports for the batteries and critical raw materials—such as lithium, cobalt, and nickel—that power these vehicles. As of 2024, around 70% of these imports originate from China. This dependency has become even more precarious following China’s imposition of export restrictions in April 2025, a retaliatory move against U.S. tariffs. These developments highlight the strategic vulnerabilities posed by China’s dominant position in the critical materials market. Compounding the issue, decades of intensive extraction have severely depleted global reserves of critical materials, widening the gap between supply and growing demand. This situation underscores the urgent need for the U.S. and other nations to diversify their sources of critical materials and enhance domestic capabilities to secure these resources—an essential step toward ensuring long-term energy security. At the end of their lifecycle—whether due to the battery’s degradation or the retirement of the vehicle—EV batteries are often improperly disposed of or sent to landfills. However, many of these batteries still retain usable capacity and can follow one of three alternative pathways: (a) Re-used: deployed in another vehicle with a shorter driving range, (b) Re-purposed: utilized act as a backup storage/power for data centers, solar panels, and e-scotters or (c) Recycled: broken down to recover the critical materials. To that end, the proposed tool (REBORN) is designed to optimize the reverse logistics network for battery repurposing and recycling. Its goal is to minimize associated costs while identifying optimal locations for battery collection and processing. Ultimately, REBORN ensures that each battery is used to its fullest potential.

Srinivas, SrikarV. [Idaho National Laboratory (INL↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗