PV Inverter Grid Support Function Assessment using Open-Source IEEE P1547.1 Test Package.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
UnitTesterSG is a unit testing framework that is designed for nested and/or scientific/engineering data structures. It is designed primarily for testing the outputs if a single function or simulation run by storing the expected results file such that comparisons to the stored output can be made with unit tests after the function or software has been edited. This module is designed to be able to unit test arrays, strings, as well as nested and deeply nested objects (including arrays with tuples inside, arrays with strings inside, etc.). The module is compatable with nested objects, and thus has a dependency on the nestedObjectsFunctions module within. The module takes *calculated* results and then compares them to *expected* results. If no expected results are available (or they do not match the calculated results) the module then offers to store the calculated results as expected results for next time.
Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.
The hybrid stochastic deterministic transport code COMET, based on the incident response expansion theory, is used to model reactor cores with high fidelity and formidable computational speed. COMET models a reactor core using a library of incident flux response expansion coefficients that are pre computed for all the unique lattice cells (e.g., fuel assemblies, reflector blocks, etc.) in the core. In order to further improve its computational efficiency in pre-calculating the response library a new response function generation method is developed to compute the response functions for the composite coarse meshes made of a smaller set of unique lattices on the fly within the COMET's deterministic transport core sweep. The efficiency is achieved by eliminating a number of unique lattices that can be made up from the reduced set of unique meshes on the fly. The numerical process consists of the following steps. First, the boundary condition on composite coarse mesh boundaries is projected onto the expansion basis to compute the incident flux moments on external surfaces of all the basic (reduced set of unique) coarse meshes. Secondly, the deterministic sweeping solver in COMET is used to converge on the outgoing/incoming flux expansion moments crossing interfaces between the basic coarse meshes. Thirdly, the response functions for the composite coarse meshes are constructed as a superposition on the fly. The new response function generation method was tested on 88 composite coarse meshes consisting of CANDU fuel bundles and moderator blocks. It was found that response functions generated by the new method agree very well with those generated by direct Monte Carlo calculations. The average and maximum relative differences in the surface-to-surface response coefficients computed by the two methods are 0.10% and 0.20%, respectively. Similarly, the average and maximum relative differences in the response fission densities are 0.13% and 0.43%, respectively. These discrepancies are within one standard deviation of the stochastic uncertainties. The new method is five times faster than the original direct Monte Carlo method. The size of the response function library for the new method is five times smaller than that for the original method, leading to significantly less requirement for the computer hard drive space and memory. (authors)
This paper presents a hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation using an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge voltage control devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results show proper functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues (e.g., instability) for field deployment.
The United States nuclear industry is facing a strong challenge to ensure maximum safety while enhancing economic benefit. Safety is a key parameter to all aspects related to light water reactor (LWR) nuclear power plants (NPPs), especially cost savings. Since the goal is to extend the lifetimes of these NPPs, the traditional deterministic safety concept may not guarantee a current economic asset. The Light Water Reactor Sustainability (LWRS) Program has been promoting a wide range of research and development (R&D) in this field to maximize the safety, economics, and performance of these NPPs through improved scientific understanding. One of the best practices to achieve this goal is to identify and optimize safety margins, which can lead to cost reduction. To do this, under the LWRS framework, the Risk-Informed Systems Analysis (RISA) Pathway will focus on the optimization of safety margin and minimization of uncertainties to ensure both safety and economics at the highest level. The RISA Pathway will provide enhanced capabilities for analyzing and characterizing LWR systems performance by developing and demonstrating methods, tools, and data to enable risk-informed margins management (RIMM). The goals of the RISA Pathway are twofold: (1) deploy the risk-informed tools and methods that enable better representation of safety margins and factors that contribute to cost and safety; and (2) conduct advanced risk assessment applications with industry to support margin management strategies that enable more cost-effective plant operation. The tools and methods provided by the RISA Pathway will support effective margin management for both active and passive safety systems, structures, and components (SSC) of an NPP. The tools and methods used in the RISA Pathway should have high confidence and highest technical maturity for and implementation to industry at its current setting. They should also have a capability to support risk-informed decision making for both probabilistic and deterministic elements of safety. The RISA Pathway will, therefore, perform a comprehensive assessment of verification and validation (V&V) status of RISA Toolkit to enhance credibility RISA Toolkit which be used by industry. This report summarizes RELAP5-3D development activities for best estimated and uncertainty (BEPU) capability to support ongoing RISA Pathway pilot projects for risk informed uncertainty quantification applications. Work scope includes (1) development of initial perturbation model for selected closure laws and (2) testing of suitable probability distribution functions (PDF) for the selected correlations. Developed BEPU modules are tested with selected separate effect cases and compared with conventional thermal-hydraulics model.
This paper presents an advanced hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation coordinated across advanced distribution management systems (ADMS), distributed energy management system (DERMS), and DERs. The HIL platform provides realistic laboratory testing, including accurate modeling of the real-world distribution system from a utility partner, real controller (ADMS and DERMs) and power (DERs) hardware, and standard communications protocols. The test results show proper functionalities of the integrated platform and performance of the peak load management of coordinated control systems. Based on the laboratory testing, the utility can set up the same grid automation system to manage DERs to achieve system-level control and operation objectives (e.g., peak load management), thus derisking potential issues (e.g., instability) for field deployment.
In this work, an “atomically-dispersed” iron-nitrogen-carbon (Fe–N–C) catalyst was used to provide a systematic comparison of platinum group metal (PGM)-free electrocatalyst degradation as a function of accelerated stress tests (ASTs) in an acidic polymer electrolyte fuel cell (PEFC). It was determined that the majority of catalyst degradation was caused by cell operation in presence of O 2 . In contrast, potential cycling of the Fe–N–C-containing cathode under inert atmosphere over typical PEFC cathode operation from 0.95 to 0.6 V had little to no effect. The increase in kinetic overpotential is shown to be the major source of the PEFC performance decrease during the ASTs. These results continue to showcase the need for development of robust PGM-free electrocatalysts in concert with improved electrochemical performance.
Accurate detection of infected individuals is one of the critical steps in stopping any pandemic. When the underlying infection rate of the disease is low, testing people in groups, instead of testing each individual in the population, can be more efficient. In this work, we consider noisy adaptive group testing design with specific test sensitivity and specificity that select the optimal group given previous test results based on pre-selected utility function. As in prior studies on group testing, we model this problem as a sequential Bayesian Optimal Experimental Design (BOED) to adaptively design the groups for each test. We analyze the required number of group tests when using the updated posterior on the infection status and the corresponding Mutual Information (MI) as our utility function for selecting new groups. More importantly, we study how the potential bias on the ground-truth noise of group tests may affect the group testing sample complexity.
The thermoacidophilic red alga Cyanidioschyzon merolae survives its challenging environment likely in part by operating a carbon-concentrating mechanism (CCM). Here, we demonstrated that C. merolae 's cellular affinity for CO 2 is stronger than the affinity of its rubisco for CO 2 . This finding provided additional evidence that C. merolae operates a CCM while lacking the structures and functions characteristic of CCMs in other organisms. To test how such a CCM could function, we created a mathematical compartmental model of a simple CCM, distinct from those we have seen previously described in detail. The results of our modeling supported the feasibility of this proposed minimal and non-canonical CCM in C. merolae . To facilitate the robust modeling of this process, we measured and incorporated physiological and enzymatic parameters into the model. Additionally, we trained a surrogate machine-learning model to emulate the mechanistic model and characterized the effects of model parameters on key outputs. This parameter exploration enabled us to identify model features that influenced whether the model met the experimentally derived criteria for functional carbon concentration and efficient energy usage. Such parameters included cytosolic pH, bicarbonate pumping cost and kinetics, cell radius, carboxylation velocity, number of thylakoid membranes, and CO 2 membrane permeability. Our exploration thus suggested that a non-canonical CCM could exist in C. merolae and illuminated the essential features generally necessary for CCMs to function.
Julienne is a compiler-portable unit-testing framework for Fortran software projects, including those that use the parallel/accelerator-programming features of Fortran 2023. Julienne achieves portability across compilers through minimalism and isolation. The minimal design ensures that Julienne uses only features supported by the majority of Fortran compilers. The isolation through zero dependencies ensures that no other projects block Julienne from building with a particular compiler. Julienne also contains with additional services that support its unit-testing code. These include functions for manipulating strings, command lines and input/output format strings; and a user-defined collective subroutine for verifying that all processes pass a test in parallel testing. Julienne's name derives from the term for vegetables sliced into thin strings: julienne vegetables. Julienne captures the authors' most frequently used thin slice of the Veggies and Sourcery software repositories while avoiding certain compiler limitations of the those two packages.
The Surveillance and Test System (SATS) checks the functionality of ATR’s Plant Protection System (PPS). The analogue linearity test checks that the SATS analog and digital conversions are accurate to +/- 61 mVdc. This project analyzes whether this accuracy range can be increased without impacting the uncertainty analysis of the PPS system.
As part of the annual FBI/LANL training schedule, a joint training exercise was conducted during the week of 10FEB2020 with FBI HEAT members and LANL Fissile Material Handlers (FMHs). The joint training exercise was conducted in a non-radiological area to reduce cost and ensure the test object would not be contaminated. The exercise test object was fabricated by LANL using surrogate materials to represent an object containing Special Nuclear Material (SNM). Working with Jim Blankenship and Kevin Swearingen, functional requirements of the test object included the following: unclassified, disassembly (to include screws), and moderately heavy. To meet the objectives, the test object was fabricated by welding a custom aluminum box (8” x 8” x 12”) with a lid which was secured by four (4) screws. The custom box housed a track and field shot put (16 lbs.) that was anchored by a hose clamp. The intent of the training was to disassemble the test object and conduct traditional forensic determinations on the parts. This lessons learned report documents all of the associated aspects related to the joint training effort.
To test the communications and cybersecurity functionality, Electric Vehicle and charging station vendors have had to ship their products to in-person testing events. This is cumbersome, expensive, inefficient, and an impediment to rapid time-to-deployment. In this project Sandia used COTS hardware and Open-Source Software to develop and demonstrate a more agile, productive approach: testing low-voltage controllers independently from high-voltage power delivery sub-systems. This approach allows communications controllers to be transported easily (e.g. shipped at low cost, checked as airline baggage); set up on a table-top (“bench testing”); and use ordinary 120 VAC outlets to conduct agile testing. Table-top platforms become end nodes that can connect to laboratory and cloud-based servers to test communications and cybersecurity, specifically Public Key Infrastructure (PKI) functionality and interoperability, separately from EV battery charging (power/energy transfer) functionality.
Branching ratios for the decay of hadrons with large width or near thresholds depend on their definition. We test different definitions and show that rather different branching ratios can be obtained. For wide resonances and for sequential decays with wide intermediate resonances, integration over the spectral functions is mandatory. The tests are performed exploiting the latest solution of the Bonn-Gatchina multi-channel analysis and published values for residues of light scalar mesons. For a resonance overlapping with a threshold, in case its pole lies in a non-adjacent sheet, we show how the total width, needed for the branching ratios, does not correspond to the imaginary part of the pole position. We use the Madrid-Krakow dispersive parameterizations to illustrate this situation with the f 0 (980).
The wrong diurnal cycle of precipitation is a common weakness of current global climate models (GCMs). To improve the simulation of the diurnal cycle of precipitation and understand what physical processes control it, we test a convective trigger function described in Xie et al. (2019) with additional optimizations in the NCAR Community Atmosphere Model version 5 (CAM5). The revised trigger function consists of three modifications: 1) replacing the Convective Available Potential Energy (CAPE) trigger with a dynamic CAPE (dCAPE) trigger, 2) allowing convection to originate above the top of planetary boundary layer (i.e., the unrestricted air parcel launch level - ULL), and 3) optimizing the entrainment rate and threshold value of the dynamic CAPE generation rate for convection onset based on observations. Results from 1°-resolution simulations show that the revised trigger can alleviate the long-standing GCM problem of too early maximum precipitation during the day and missing the nocturnal precipitation peak that is observed in many regions, including the U.S. southern Great Plains (SGP). The revised trigger also improves the simulation of the propagation of precipitation systems downstream of the Rockies and the Amazon region. A further composite analysis over the SGP unravels the mechanisms through which the revised trigger affects convection. Additional sensitivity tests show that both the peak time and the amplitude of the diurnal cycle of precipitation are sensitive to the entrainment rate and dCAPE threshold values.
This project explores the use of Wiener deconvolution to recover an original signal that has been distorted by a known transfer function and by noise. A simulated Gaussian pulse was used as the test signal, and a transfer function was applied in the frequency domain to model system distortion. Controlled noise was then introduced to approximate real-world signal degradation. A Wiener filter was implemented to reverse the effects of the transfer function while minimizing the influence of noise. The recovered signal was compared to the original pulse to evaluate the effectiveness of the filter. Results demonstrate that Wiener deconvolution offers a stable and effective approach to signal recovery, balancing complete transfer function inversion and noise suppression.
Between 2016 and 2018, the Hanford Tank Operations Contractor - Washington River Protection Solutions (WRPS) - conducted a series of tests of air-purifying respirator (APR) chemical cartridges commonly used at Hanford tank farms to determine the period of time for which the cartridges would provide adequate performance when used in APRs and powered-air-purifying respirators (PAPRs) to protect workers when exposed to a mixture of vapors exiting tank headspaces. Although cartridge manufacturers provide service life estimating tools for individual chemical compounds, the projected performance of these cartridges on complex vapor mixtures is not available, and the adequacy of APRs for tank farm applications represents an important workforce concern. The Occupational Safety and Health Administration identifies cartridge testing as a valid approach for establishing cartridge service life. The primary function of the WRPS Cartridge Test Program was to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford tank farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis of and recommendations based on respirator cartridge performance. A total of 28 APR and 10 PAPR cartridge tests were conducted between 2016 and 2018 on 12 different tank headspaces and tank farm exhauster slipstreams. Two APR cartridges from SCOTT (now 3M) and two PAPR cartridges from MSA Safety, Inc. and 3M were evaluated using a cartridge testing system specifically designed to measure and monitor test conditions and sample cartridge inlet and outlet vapor streams for important chemical compounds. Testing focused on analysis of approximately 61 tank vapor chemicals of potential concern (COPCs) that have been previously detected in tank vapors at levels above 10% of their occupational exposure limits (OELs). Each test was conducted over 16 hours of run time. Evidence of chemical breakthrough was assessed by comparing inlet and outlet COPC concentrations over the duration of each test. The breakthrough threshold was normally defined as exceeding 10% of the compounds OEL at the cartridge outlet. Ammonia breakthrough was observed in a majority of the cartridge tests and occurred earlier than breakthrough of any other chemical compound. Several other COPCs did exhibit breakthrough behavior, including mercury, 1,3-butadiene, furan, 2,5 dihydrofuran, and N-nitrosodimethylamine (NDMA), but only in a very limited number of cartridge tests and only after ammonia breakthrough had occurred. In addition, tests results suggest that breakthrough of some of these COPCs may have been affected by competition with and breakthrough of other non-COPC organics, such as ethanol and acetone, with substantially lower toxicological hazard. Comparison of cartridge manufacturers' service life estimates with the experimentally derived breakthrough times indicates that manufacturers' estimates are generally conservative, even in the presence of the complex mixed vapor streams experienced in these tests. With consideration of appropriate safety margins, these results provide valuable insights on cartridge performance to inform industrial hygiene professionals in establishing appropriate cartridge change-out schedules for APR and PAPR use in the Hanford tank farms. (authors)