Search NASA⌕ Search

SEARCH · Search NASA

Results for “test protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Swab Tensile Testing Results and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the “Aged” swabs. For the “Aged” swabs, the tensile tests were performed 7 days after the Autoclave pre -treatment. All swabs were provided by HP.

36 MATERIALS SCIENCE↗

Swab Tensile Testing Results and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the Injection Molded samples. For the Injection Molded samples, the tensile tests were performed within 24 hours of the completion of the Autoclave pre-treatment. The FormLabs-USF and FormLabs-Northwell were printed at LLNL using FormLabs Surgical Grade V1 Resin on a Form 3B Printer. All other samples were provided by HP.

36 MATERIALS SCIENCE↗

Swab Tensile Testing Results and Procedures - PA11 Rev. 10 Swabs

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. All swabs were provided by HP and were the PA11 material and Rev 10 design. All of the swabs were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the “Aged” swabs. For the “Aged” swabs, the tensile tests were performed 7 days after the Autoclave pre -treatment. The “Aged” swabs that were not pre-treated using the Autoclave, were tested 7 days after those that were not “Aged.”

36 MATERIALS SCIENCE↗

I.6.C Battery Safety Testing

Abuse tests are designed to determine the safe operating limits of HEV\PHEV energy storage devices. Testing is intended to achieve certain worst-case scenarios to yield quantitative data on cell\module\pack response, allowing for failure mode determination and guiding developers toward improved materials and designs. Standard abuse tests with defined start and end conditions are performed on all devices to provide comparison between technologies. New tests and protocols are developed and evaluated to more closely simulate real world failure conditions. While robust mechanical models for vehicles and vehicle components exist, there is a gap for mechanical modeling of EV batteries. The challenge with developing a mechanical model for a battery is the heterogeneous nature of the materials and components (polymers, metals, metal oxides, liquids).

25 ENERGY STORAGE↗

COVID-19 prevention at institutions of higher education, United States, 2020–2021: implementation of nonpharmaceutical interventions

Background, In early 2020, following the start of the coronavirus disease 2019 (COVID-19) pandemic, institutions of higher education (IHEs) across the United States rapidly pivoted to online learning to reduce the risk of on-campus virus transmission. We explored IHEs’ use of this and other nonpharmaceutical interventions (NPIs) during the subsequent pandemic-affected academic year 2020–2021. Methods, From December 2020 to June 2021, we collected publicly available data from official webpages of 847 IHEs, including all public (n = 547) and a stratified random sample of private four-year institutions (n = 300). Abstracted data included NPIs deployed during the academic year such as changes to the calendar, learning environment, housing, common areas, and dining; COVID-19 testing; and facemask protocols. We performed weighted analysis to assess congruence with the October 29, 2020, US Centers for Disease Control and Prevention (CDC) guidance for IHEs. For IHEs offering ≥50% of courses in person, we used weighted multivariable linear regression to explore the association between IHE characteristics and the summated number of implemented NPIs. Results, Overall, 20% of IHEs implemented all CDC-recommended NPIs. The most frequently utilized NPI was learning environment changes (91%), practiced as one or more of the following modalities: distance or hybrid learning opportunities (98%), 6-ft spacing (60%), and reduced class sizes (51%). Additionally, 88% of IHEs specified facemask protocols, 78% physically changed common areas, and 67% offered COVID-19 testing. Among the 33% of IHEs offering ≥50% of courses in person, having < 1000 students was associated with having implemented fewer NPIs than IHEs with ≥ 1000 students. Conclusions, Only 1 in 5 IHEs implemented all CDC recommendations, while a majority implemented a subset, most commonly changes to the classroom, facemask protocols, and COVID-19 testing. IHE enrollment size and location were associated with degree of NPI implementation. Additional research is needed to assess adherence to NPI implementation in IHE settings.

59 BASIC BIOLOGICAL SCIENCES↗

Module OT Laboratory Test Procedure

This document will detail a test procedure, involving bench and emulation testing, for the Module OT device developed for the joint NREL-SNL DOE CEDS project titled "Modular Security Apparatus for Managing Distributed Cryptography for Command & Control Messages on Operational Technology (OT) Networks." The aim of this document is to create the testing and evaluation protocol for the module for lab-level testing; this includes checklists and experiments for information gathering, functional testing, cryptographic implementation, public key infrastructure, key exchange/authentication, encryption, and implementation testing in the emulation environment.

97 MATHEMATICS AND COMPUTING↗

Research to Develop Flood Barrier Testing Strategies for Nuclear Power Plants

The U.S. Nuclear Regulatory Commission has developed regulations regarding the siting and design of nuclear power plants (NPPs) that are aimed at addressing various natural hazards, including flooding. Flood barriers are designed to prevent water from entering NPP areas containing structures, systems, and components (SSCs) important to safety. The barriers are used at NPPs along with drains, sumps, pumps, valves, plugs, and site grading as part of the plant flood protection features that protect SSCs from experiencing external or internal flooding and mitigate the effects of flooding on NPP operations. The performance of flood protection features, including flood barriers at NPPs, has been an ongoing concern. Domestic and international operational experience provides clear indications that flood barrier performance has significant safety implications, especially for aging NPPs. The observed deficiencies show that flood barriers should be designed and installed properly, then adequately tested, inspected, and maintained in order to ensure that they perform their intended functions during flooding events. Here, this paper reviews available information related to flood barriers employed at U.S. NPPs and provides an overview and categorization of NPP flood barriers. It identifies potential domestic and international flood barrier testing facilities, including operating and decommissioned U.S. NPPs. Finally, this paper presents the technical and logistical considerations that should be made when developing specific testing strategies and protocols for flood barriers, such as the selection of flood barriers, test locations, testing approach, performance criteria, and testing parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bayesian learning for rapid prediction of lithium-ion battery-cycling protocols

Advancing lithium-ion battery technology requires the optimization of cycling protocols. A new data-driven methodology is demonstrated for rapid, accurate prediction of the cycle life obtained by new cycling protocols using a single test lasting only 3 cycles, enabling rapid exploration of cycling protocol design spaces with orders of magnitude reduction in testing time. We achieve this by combining lifetime early prediction with a hierarchical Bayesian model (HBM) to rapidly predict performance distributions without the need for extensive repetitive testing. The methodology is applied to a comprehensive dataset of lithium-iron-phosphate/graphite comprising 29 different fast-charging protocols. HBM alone provides high protocol-lifetime prediction performance, with 6.5% of overall test average percent error, after cycling only one battery to failure. Here, by combining HBM with a battery lifetime prediction model, we achieve a test error of 8.8% using a single 3-cycle test. In addition, the generalizability of the HBM approach is demonstrated for lithium-manganese-cobalt-oxide/graphite cells.

25 ENERGY STORAGE↗

The Dynamic Assimilation Technique measures photosynthetic CO2 response curves with similar fidelity as steady-state approaches in half the time

The net CO2 assimilation (A) response to intercellular CO2 concentration (Ci) is a fundamental measurement in photosynthesis and plant physiology research. The conventional A/Ci protocols rely on steady-state measurements and take 15-40 minute per measurement, limiting data resolution or biological replication. Additionally, there are several CO2 protocols employed across the literature, without clear consensus as to the optimal protocol or systematic biases in their estimations. We compared the non-steady state Dynamic Assimilation Technique (DAT) protocol and the three most used CO2 protocols in steady-state measurements, and tested whether different CO2 protocols lead to systematic differences in estimations of the biochemical limitations to photosynthesis.

A/Ci response↗

Advancing reliability assessments of photovoltaic modules and materials using combined-accelerated stress testing

Previously undiscovered failure modes in photovoltaic (PV) modules continue to emerge in field installations despite passing protocols for design qualification and quality assurance. Failure to detect these modes prior to widespread use could be attributed to the limitations of present-day standard accelerated stress tests (ASTs), which are primarily designed to identify known degradation or failure modes at the time of development by applying simultaneous or sequential stress factors (usually two at most). Here, we introduce an accelerated testing method known as the combined-accelerated stress test (C-AST), which simultaneously combines multiple stress factors of the natural environment. Simultaneous combination of multiple stress factors allows for improved identification of failure modes with better ability to detect modes not known a priori. A demonstration experiment was conducted that reproduced the field-observed cracking of polyamide- (PA-) and polyvinylidene fluoride (PVDF)–based backsheet films, a failure mode that was not detected by current design qualification and quality assurance testing requirements. In this work, a two-phase testing protocol was implemented. The first cycle (“Tropical”) is a predominantly high-humidity and high-temperature test designed to replicate harsh tropical climates. The second cycle (“Multi-season”) was designed to replicate drier and more temperate conditions found in continental or desert climates. Testing was conducted on 2 × 2-cell crystalline-silicon cell miniature modules constructed with both ultraviolet (UV)–transmitting and UV-blocking encapsulants. Cracking failures were observed within a cumulative 120 days of the Tropical condition for one of the PA-based backsheets and after 84 days of Tropical cycle followed by 42 days of the Multi-season cycle for the PVDF-based backsheet, which are both consistent with failures seen in fielded modules. In addition to backsheet cracking, degradation modes were observed including solder/interconnect fatigue, various light-induced degradation modes, backsheet delamination, discoloration, corrosion, and cell cracking. The ability to simultaneously apply multiple stress factors may allow many of the test sequences within the standardized design qualification procedure to be performed using a single test setup.

14 SOLAR ENERGY↗

Mitigation of PtCo/C Cathode Catalyst Degradation via Control of Relative Humidity

Maintaining the high performance of proton-exchange membrane fuel cells (PEMFC) over the course of its lifetime is a key enabling factor for its successful commercialization as a primary power source in zero-emission transportation applications. In this context, it is important to mitigate the degradation of PtCo-alloy based cathode catalysts used for oxygen reduction reaction (ORR). PtCo-alloy catalysts exhibit high activity at beginning-of-life (BOL) which tends to decrease during operation due to loss of electrochemical surface area (ECSA) and dissolution-contamination related effects of the Co-alloying component. Here, we demonstrate the use of relative humidity (RH) of the inlet gases as a controllable parameter to mitigate the degradation of PtCo-alloy catalyst degradation. We employ a catalyst-specific voltage cycling accelerated stress test (AST) durability protocol as a function of inlet RH to degrade PtCo catalysts. A series of in situ electrochemical diagnostics and ex situ characterizations have been carried out to investigate the catalyst layer characteristics at end-of-test (EOT). Our results show that at sub-saturated conditions of durability protocol operation, PtCo catalyst sustains higher EOT H 2 /air performance due to better retention of ECSA and smaller impact of Co 2+ dissolution/contamination.

25 ENERGY STORAGE↗

High Air-Flow Aerosol Filtration Testing

Pressure losses and aerosol collection efficiencies were measured for fibrous filter materials at air-flow rates consistent with high efficiency filtration (hundreds of cubic feet per minute). Microfiber filters coated with nanofibers were purchased and fabricated into test assemblies for a 12-inch duct system designed to mimic high efficiency filtration testing of commercial and industrial processes. Standards and specifications for high efficiency filtration were studied from a variety of institutions to assess protocols for design, testing, operations and maintenance, and quality assurance (e.g., DOE, ASHRAE, ASME). Three materials with varying Minimum Efficiency Reporting Values (MERV) were challenged with sodium chloride aerosol. Substantial filter loading was observed where aerosol collection efficiencies and pressure losses increased during experiments. Filter designs will be optimized and characterized in subsequent years of this study. Additional testing will be performed with higher hazard aerosols at Oak Ridge National Laboratory.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning for continuous quantum error correction on superconducting qubits

Abstract Continuous quantum error correction has been found to have certain advantages over discrete quantum error correction, such as a reduction in hardware resources and the elimination of error mechanisms introduced by having entangling gates and ancilla qubits. We propose a machine learning algorithm for continuous quantum error correction that is based on the use of a recurrent neural network to identify bit-flip errors from continuous noisy syndrome measurements. The algorithm is designed to operate on measurement signals deviating from the ideal behavior in which the mean value corresponds to a code syndrome value and the measurement has white noise. We analyze continuous measurements taken from a superconducting architecture using three transmon qubits to identify three significant practical examples of non-ideal behavior, namely auto-correlation at temporal short lags, transient syndrome dynamics after each bit-flip, and drift in the steady-state syndrome values over the course of many experiments. Based on these real-world imperfections, we generate synthetic measurement signals from which to train the recurrent neural network, and then test its proficiency when implementing active error correction, comparing this with a traditional double threshold scheme and a discrete Bayesian classifier. The results show that our machine learning protocol is able to outperform the double threshold protocol across all tests, achieving a final state fidelity comparable to the discrete Bayesian classifier.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LANL Contributions to pyiron: An integrated development environment for computational materials science

To support and accelerate the development of simulation protocols in atomistic modelling, we introduce an integrated development environment (IDE) for computational materials science called pyiron (http://pyiron.org). The pyiron IDE combines a web based source code editor, a job management system for build automation, and a hierarchical data management solution. The core components of the pyiron IDE are pyiron objects based on an abstract class, which links application structures such as atomistic structures, projects, jobs, simulation protocols and computing resources with persistent storage and an interactive user environment. The simulation protocols within the pyiron IDE are constructed using the Python programming language. To highlight key concepts of this tool as well as to demonstrate its ability to simplify the implementation and testing of simulation protocols we discuss two applications. In these examples we show how pyiron supports the whole life cycle of a typical simulation, seamlessly combines ab initio with empirical potential calculations, and how complex feedback loops can be implemented. While originally developed with focus on ab initio thermodynamics simulations, the concepts and implementation of pyiron are general thus allowing to employ it for a wide range of simulation topics.

Janssen, Jan↗

Advancing Development of Emissions Detection (Final Report)

This document is the final report to the U.S. Department of Energy (DOE for contract DE-FE0031873) awarded to Colorado State University (CSU). CSU and partners at Harrisburg University of Science and Technology, University of Texas Arlington, and University of Texas at Austin organized several testing rounds to provide knowledge focused on advancing the detection capabilities of emissions monitoring devices. With this funding opportunity the research group began by establishing the Advancing the Development of Emission Detection (ADED) program, with the goal focused on enhancing the accuracy, reliability, and field applicability of methane detection technologies. This effort aimed to address the critical challenges of identifying and quantifying methane emissions while enabling industry stakeholders to meet regulatory compliance and environmental sustainability goals. The program engaged with industry, government, and technology stakeholders to promote adoption and consensus on testing techniques for methane detection solutions. Methane, a potent greenhouse gas, contributes significantly to global warming, and the oil and natural gas (O&G) sector is a primary source of methane emissions. Regulatory measures such as leak detection and repair (LDAR) programs have been implemented to address emissions. However, traditional LDAR approaches, reliant on handheld and component-level measurements, are resource-intensive. To address these limitations and move with evolving regulations, advanced methane technologies are emerging. These solutions include ground-based sensors, mobile systems (e.g., drones, vehicles, and aircraft), and satellite-based platforms. They offer innovative capabilities for autonomous monitoring, larger spatial coverage, and emission quantification using methods such as tracer gas techniques and inverse modeling with Gaussian plume analysis. The ADED program began with creating protocols for methane controlled release (CR) testing these continuous monitoring (CM) and survey technologies that detect and monitor methane emissions at O&G facilities. The protocols were then implemented throughout testing of CM and survey devices at CSU’s Methane Emissions Technology Evaluation Center (METEC) facility from 2021 through 2024. As apart of the protocol, solutions that tested under the ADED program installed their solutions at METEC, documented their system under test, and provided detection reports to the METEC team for analysis. The METEC team would provide the solutions with analyzed reports of their emissions and ground truth data of the releases conducted during their testing session. Under the ADED program, CMs were also tested at O&G facilities for a six week test run of challenge release (ChR) releases. The findings from the ADED program underscore the critical role of collaborative research and innovation in tackling methane emissions, offering a pathway for the oil and gas sector to achieve significant environmental and economic benefits. Results from METEC testing saw improvement of performance and accuracy across all solutions over the extent of the ADED experiments. The results also showed a variance in CM solution performance between CRs and ChRs. That variance pushed the team to further analyze the differences between CR testing environments and field conditions. With the drive from regulations and that variance in field conditions, the ADED team began designing a new CR testing protocol and additions to the METEC testing facility. The METEC team is furthering the progress made through the ADED program with awarded funding from DE-FE0032276. This funding pushes the development of METEC’s addition with new equipment, allowing for an updated facility layout. METEC still facilitates for traditional facilities, with a legacy pad, while expanding an new design based on how O&G infrastructure has Final Report - Contract Number: DE-FE0031873 been changed over the last decade. Throughout the ADED program the team has also been working with international partners to ensure staying in the trend globally. International partners have been essential in moving the new protocol forward to implement into CR testing at the METEC facility in Spring 2025.

42 ENGINEERING↗

Methylation protocol for the retrospective detection of isopropyl-, pinacolyl- and cyclohexylmethylphosphonic acids, indicative markers for the nerve agents sarin, soman and cyclosarin, at low levels in soils using EI-GC–MS

A practical and efficient protocol for the derivatization and detection by GC-EI-MS of isopropyl-, pinacolyl- and cyclohexylmethylphosphonic acids, key diagnostic degradation products of the nerve agents sarin, soman and cyclosarin respectively, in six different types of soil matrices is presented here. The method involves the in situ conversion of the phosphonic acids to their respective methyl esters using trimethyloxonium tetrafluoroborate when present in the soils at low levels (10 μg g -1 ) without any prior extractions or soil preparation. The soils employed in our study were Nebraska EPA soil, Georgia soil, silt, Virginia type A soil, regular sand and Ottawa sand and were chosen for their vast differences in composition and physical features. Appealing attributes of the protocol include its rapidity (t < 30 min), mildness (ambient temperature), and practicality that includes the production of the phosphonic methyl esters that can be easily detected by GC-EI–MS and corroborated with the instrument&#x27;s internal NIST spectral library or the Organisation for the Prohibition of Chemical Weapons (OPCW) central analytical database (OCAD v.21_2019). The overall efficacy of the protocol was then tested on a soil sample featured in the 44th OPCW PT that our laboratory participated in. After preparing the soil so as to give pinacolyl methylphosphonic acid at a 5 μg g -1 concentration, the acid was successfully methylated and detected by GC-EI-MS. The protocol's performance mirrors that of the universally employed diazomethane protocol but accomplishes this without any of the explosive hazards and time consuming reagent preparation commonly associated with it.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Best Practices in PEC Water Splitting: How to Reliably Measure Solar-to-Hydrogen Efficiency of Photoelectrodes

Photoelectrochemical (PEC) water splitting, which utilizes sunlight and water to produce hydrogen fuel, is potentially one of the most sustainable routes to clean energy. One challenge to success is that, to date, similar materials and devices measured in different labs or by different operators lead to quantitatively different results, due to the lack of accepted standard operating procedures and established protocols for PEC efficiency testing. With the aim of disseminating good practices within the PEC community, we provide a vetted protocol that describes how to prepare integrated components and accurately measure their solar-to-hydrogen (STH) efficiency (η STH ). This protocol provides details on electrode fabrication, η STH test device assembly, light source calibration, hydrogen evolution measurement, and initial material qualification by photocurrent measurements under monochromatic and broadband illumination. Common pitfalls in translating experimental results from any lab to an accurate STH efficiency under an AM1.5G reference spectrum are discussed. A III–V tandem photocathode is used to exemplify the process, though with small modifications, the protocol can be applied to photoanodes as well. Dissemination of PEC best practices will help those approaching the field and provide guidance for comparing the results obtained at different lab sites by different groups.

08 HYDROGEN↗