Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Building Energy Modeling Enhancements to Identify Least-Cost Pathways to Net-Zero Carbon Homes: Preprint

Residential grid-interactive efficient buildings (GEBs) can utilize high levels of energy efficiency and demand flexibility to deliver value to occupants, the grid, and society. However, without the ability to analyze, design, and optimize residential GEBs there is a risk that homes will not realize their full potential value as efficient and dynamic resources, which could ultimately lead to higher than necessary energy costs for U.S. households and lower realization of potential energy efficiency and demand flexibility benefits such as increased convenience/automation, thermal comfort, durability, indoor air quality, and resilience. In 2018, the National Renewable Energy Laboratory (NREL) Residential Modeling Team developed a vision for an open source Residential GEB Analytics Platform built within DOE's EnergyPlus and OpenStudio modeling environment that would enable the design and optimization of residential GEBs, including the identification of least-cost pathways to highly energy-efficient and energy-flexible homes (e.g., net zero carbon homes). We created a detailed workplan for the development of new and enhanced residential GEB component-level models for EnergyPlus and OpenStudio needed to progress toward the vision for the analytics platform while delivering near-term benefits to industry. This paper 1) presents the vision for the platform, summarizing the workplan for residential GEB modeling enhancements; 2) highlights significant advancements that have been achieved between 2018 and 2022, including stochastic residential occupancy modeling, flexible water heater modeling, detailed lithium-ion stationary battery modeling, and realistic residential HVAC modeling; and 3) outlines ongoing efforts and next steps toward the full vision for the platform.

building energy modeling↗

A modular chemo-selective oxygen production unit to deliver oxygen for advanced combustion systems

Commercial oxygen generation technologies deploy either cryogenic air separation or vacuum pressure swing adsorption (VPSA). These technologies can provide nearly pure oxygen but are only economically viable at oxygen production rates of 100-7,000 tonnes/day. The state-of-theart cryogenic air separation plants are impending the theoretical limits of thermodynamic efficiency but cannot be scaled down to cater future needs. Therefore, there is great incentive to develop a new approach for oxygen separation that can accommodate the upcoming demands. Our proposed research approach address to find novel methodologies to provide energy efficient modular O 2 on demand systems for modular gasification and other applications. Small scale modular systems for O 2 production offer certain benefits including enhanced energy efficiency, reduced operating costs and flexibility to tailor location specific needs. Our hypothesis is that a small modular system could be engineered using solvent-based capture and thermal release of oxygen, to enable “oxygen on demand” for any combustion-related technology.

42 ENGINEERING↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Performance Assessment of the Overall Building Envelope Thermal Performance—Building Envelope Performance (BEP) Metric

Today, to describe the thermal performance of the building envelope and its components we use a variation of metrics; such as, R-value, ACH (air exchange rate per hour), SHGC (solar heat gain coefficient) of windows, U-factor etc. None of these performance indicators is meant to represent the overall thermal performance. In this paper, such a metric is introduced, the BEP (building envelope performance) value. Unlike the thermal resistance, typically expressed as an R-value, the BEP-value considers additional elements of heat transfer that affect the energy demand of the building because of exterior and interior (solar) thermal loads: conductive and radiant heat transfer, and air infiltration. To demonstrate BEP’s utility, validation studies were carried out by comparing the BEP-value to theoretical results using whole building energy simulation tools such as EnergyPlus and WUFI Plus. Results show that BEP calculations are comparable to calculations made using these simulation tools and that unlike other similar metrics, the BEP-value accounts for all heat transfer mechanisms that are relevant for the overall energy performance of the building envelope. The BEP-value thus allows comparing envelopes of buildings with different use types in a fair and realistic manner.

42 ENGINEERING↗

Ultrasonic Characterization of Lithium Ion Thermal Runaway Conditions for Real-time Ultrasonic Enabled BMS Integration

The demand for energy storage is growing, and lithium-ion batteries are a promising technology to meet this need due to their high power/energy density, high round-trip efficiency, rapid response time, and portability. However, recent catastrophic events caused by thermal runaway have slowed their adoption, highlighting the need for an early warning system for battery failure. In this work, ultrasound is used to detect physical changes in 950 mAh batteries by identifying material property changes independent of voltage and current. [Ultrasound signal features (e.g., time of flight, maximum frequency component) were extracted as the batteries were cycled and subjected to both constant current and constant voltage overcharge and were used to develop two metrics identifying failure: a warning to detect the start of overcharge and an emergency stop (E-stop) to immediately take the battery out of service. The identification method involved locating magnitude differences of several ultrasound features compared to baseline operation considering different currents and temperatures, and the warning/stopping metrics were consistent across all experiments. For an average overcharge time of 140 minutes, the average warning was issued 124 minutes before the failure and the average E-stop was triggered 94 minutes before failure. As a test of using ultrasound for early warning detection, a battery was forced into overcharge and returned to normal cycling conditions based on the previously determined warning metric. Both the voltage profile and the ultrasound measurements returned to their baseline behavior, indicating that ultrasonic detection can not only identify battery failure before a catastrophic event, but can also provide early enough warnings such that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.]

25 ENERGY STORAGE↗

Ultrasonic Elastography for Nondestructive Evaluation of Dissimilar Material Joints

Dissimilar material joints or multilayered metals have become inevitable in the manufacturing industry due to the increasing demand for multifunctional materials with variable mechanical, thermal, or electrical characteristics in a single assembly. Lattice mismatch of materials at the interface of dissimilar materials leads to inferior mechanical characteristics. In particular, the mismatch in elastic properties indicated by a large initial elastic deformation is critical to determine the extent of variation in stress. However, nanoindentation, the most common and accepted technique to measure elastic modulus, is destructive, time-consuming, and can only examine mechanical properties within a limited area. A non-invasive elastographic mapping technique evaluates the mechanical properties using ultrasonic elastography to study incompressibility. The dissimilar joint between steel and copper was obtained via friction stir welding. The variation of the stress developed at the welded joint of the two different metals was evaluated from the dynamic bulk modulus map. A tensile test of the involved workpiece confirmed a good agreement with our analysis based on the dynamic bulk modulus elastographic mapping results. This study provides a rapid and non-invasive technique for the bulk metallurgic elastic modulus inspection to overcome the limitations of conventional methods.

Jin, Yuqi↗

First-principles calculation of lattice distortion, electronic structure, and bonding properties of GeTe-based and PbSe-based high-entropy chalcogenides

The massive amount of wasted heat energy from industry has pushed the development of thermoelectric (TE) materials that directly convert heat into electricity to a new level of concern. Recently, multicomponent alloys such as GeTe-based and PbSe-based high-entropy (HE) chalcogenides have attracted a great deal of attention due to their potential application as TE materials. The nature of the interatomic bonding, lattice distortion (LD), and the electronic structure in this class of materials is not fully understood. Herein, we report a comprehensive computational investigation of nine GeTe-based HE alloys with eight metallic elements (Ag, Pb, Sb, Bi, Cu, Cd, Mn, and Sn) with large supercells of 1080 atoms each; seven PbSe-based HE solid solutions: Pb0.99−ySb0.012SnySe1−2xTexSx (x = 0.1, 0.2, 0.25, 0.3, 0.35, 0.4, 0.45, with y = 0) with supercells of 1000 atoms each; and five Pb0.99−ySb0.012SnySe1−2xTexSx (y = 0.05, 0.1, 0.15, 0.2, 0.25 with x = 0.25) solid solutions with supercells of 1000 atoms each. All these HE models are theoretically investigated for the first time. The electronic structure, interatomic bonding, charge transfer, and lattice distortion (LD) are investigated by first-principles calculations based on density functional theory. Multicomponent HE alloys can cause a significant LD, which affects their mechanical, thermal, and TE properties. The calculations for the GeTe-based HE chalcogenides showed that they are semiconductors with a narrow bandgap, except for m8, which has a semi-metallic characteristic, and this makes them good candidates for TE applications. For most of these models, the Fermi level shifts upward and locates deeply in the conduction bands, resulting in the enhancement of the electrical conductivity (σ). The bonding properties showed that most bonds in m5 are more dispersed, indicating highest LD and lower lattice thermal conductivity. For PbSe-based HE solid solutions, the LD calculations showed that the models Pb0.99Sb0.012Se0.5Te0.25S0.25 and Pb0.89Sb0.012Sn0.1Se0.5Te0.25S0.25 have the higher LD, and thus a lower lattice thermal conductivity. Such investigations are in high demand since it enables us to design new HE chalcogenides for TE applications. We use the novel concept of total bond order density as a single quantum mechanical metric to characterize the internal cohesion of these HE alloys and correlate with calculated properties, especially the mechanical properties. This work provides a solid database for HE chalcogenides and a road map for many potential applications. Moreover, the computational procedure we developed can be used to design new HE chalcogenides for specific TE applications.

Physics↗

Smart building HVAC control challenge: experience and solutions from the ADRENALIN project

A smart building HVAC control competition crowdsourced and compared algorithms on fair and equal ground using the standardized BOPTEST framework. The competition attracted 138 participants, but only 9% submitted valid solutions for the final stage, highlighting the complexity of advanced HVAC control design. The winning solutions showed significant potential to reduce energy use and cost by shifting demand, without compromising occupant comfort. Across scenarios, thermal energy cost reductions of 36–76% relative to a baseline, were achieved. In peak heat periods, the cost reduction leveraged limited energy use reduction (0–15%), but more significant energy price reduction (34–62%). This shows smart controls' ability to avoid as much as possible consumption during the morning peak hours, when spot prices are tendentially the highest. Hosting the competition has highlighted challenges in creating competitions that both are fair and promotes solutions that are transferable to real life implementation.

BOPTEST↗

Empirically-calibrated H100 node power models for accurate AI training energy estimation

Accurately quantifying the energy use of artificial intelligence (AI) training is critical for infrastructure planning, carbon accounting, and sustainable data center operation, but few studies have directly measured the power consumption of production workloads on contemporary hardware. By combining empirical measurements from Brookhaven National Laboratory during AI training on 8-graphics-processing-unit H100 systems with open-source benchmarking data, we develop statistical models relating computational intensity to node-level power consumption. We measure the gap between manufacturer-rated thermal design power (TDP) and actual power demand during AI training. Our analysis reveals that even computationally intensive workloads operate at only 76% of the 10.2 kW TDP rating. Our architecture-specific model, calibrated to floating-point operations, predicts energy consumption with 11.4% mean absolute percentage error, significantly outperforming TDP-based approaches (27%–37% error). We identified distinct power signatures between transformer and convolutional neural network architectures, with transformers showing characteristic fluctuations that may impact grid stability. These results provide a measurement-grounded basis for improving AI training energy estimates, enabling more reliable infrastructure sizing, cost projections, and environmental impact assessments.

Newkirk, Alex C↗

Leadership and Community Engagement in Chile: Deploying Net-Zero Technologies and Solutions

The report presents the 2023 Net Zero World Chile program results from activities of the the four program workstreams: 1) energy-system wide modeling LEAP modeling and analysis results including accelerated Net Zero scenarios with aggressive energy efficiency improvements, fuel switching, and electrification across demand sector; 2) district energy chapter provides thermal district energy systems modeling results of the Recoleta-Independencia pilot project and comparative analysis of district energy systems' potential versus competing technologies in Chile; 3) just transition action steps for the creation of a sister city relationship between Tocopilla and a US counterpart city; and 4) power decarbonization capacity building activities focused on the selection and adoption of grid-enhancing technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Science and Technology of High Performance Ferritic (HiperFer) Stainless Steels

Future, flexible thermal energy conversion systems require new, demand-optimized high-performance materials. The High performance Ferritic (HiperFer) stainless steels, under development at the Institute of Microstructure and Properties of Materials (IEK-2) at Forschungszentrum Jülich GmbH in Germany, provide a balanced combination of fatigue, creep and corrosion resistance at reasonable price. This paper outlines the scientific background of alloy performance development, which resulted in an age-hardening ferritic, stainless steel grade. Furthermore, technological properties are addressed and the potential concerning application is estimated by benchmarking versus conventional state of the art materials.

36 MATERIALS SCIENCE↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

47 OTHER INSTRUMENTATION↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

ADVANCED PROPULSION SYSTEMS↗

Electric Motor Thermal Management

Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

ADVANCED PROPULSION SYSTEMS↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Department of Energy/IDEA: More best-practices research

This article continues the overview of the U.S. Department of Energy and IDEA collaboration by highlighting additional case studies that demonstrate innovative engineering approaches in district energy systems. It focuses on how campuses are improving efficiency, integrating advanced technologies, and reducing energy use and emissions through data-driven strategies. The University of Cincinnati is featured for its highly efficient chilled water system, using advanced algorithms and upgraded “smart chillers” to optimize performance, reduce energy consumption, and lower costs. Wake Forest University emphasizes a data-informed modernization process, using system optimization and targeted building improvements to significantly boost efficiency and reduce overall energy use. Arizona Western College showcases creative solutions to extreme cooling demands, including system redesign, smart controls, and thermal storage to improve reliability and cut peak energy costs. Overall, the article demonstrates that combining innovative engineering, real-time data analysis, and system optimization can significantly enhance performance, reduce emissions, and deliver cost savings in district energy systems.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗