Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Impact of Manual and Automated Interpretation of Fused PET/CT Data on Esophageal Target Definitions in Radiation Planning

Purpose: We compare CT-only based esophageal tumor definition with two PET/CT based methods: (1) manual contouring and (2) a semiautomated method based on specific thresholds. Methods and Materials: Patients with esophageal cancer treated at Brigham and Women's Hospital from 2003 to 2006 were identified. CT-based tumor volumes were compared with manual PET/CT-based volumes and semiautomated PET-based tumor volumes. Differences were scored as (1) minor if the superior or inferior extent of the primary tumor (or both) differed by 1-2 cm and (2) major if the difference was > 2 cm or if different noncontiguous nodal regions were identified as being grossly involved. Results: Comparing CT-based gross tumor volumes (GTVs) to manually defined PET/CT-based GTVs, use of PET changed volumes for 21 of 25 (84%) patients: 12 patients (48%) exhibited minor differences, whereas for 9 patients (36%), the differences were major. For 4 (16%) patients, the major difference was due to discrepancy in celiac or distant mediastinal lymph node involvement. Use of automated PET volumes changed the manual PET length in 14 patients (56%): 8 minor and 6 major. Conclusions: The use of PET/CT in treatment planning for esophageal cancer can affect target definition. Two PET-based techniques can also produce significantly different tumor volumes in a large percentage of patients. Further investigations to clarify the optimal use of PET/CT data in treatment planning are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Evaluation of Nanosecond Pulsed Laser-Induced Photomodification of Plasmonic Gold Nanoparticles

The rapid growth of gold nanoparticle applications in laser therapeutics and diagnostics has brought about the need for establishing innovative standardized test methods for evaluation of safety and performance of these technologies and related medical products. Furthermore, given the incomplete and inconsistent data on nanoparticle photo-modification thresholds provided in the literature, further elucidation of processes that impact the safety and effectiveness of laser-nanoparticle combination products is warranted. Therefore, we present a proof-of-concept study on an analytical experimental test methodology including three approaches (transmission electron microscopy, dynamic light scattering, and spectrophotometry) for experimental evaluation of damage thresholds in nanosecond pulsed laser-irradiated gold nanospheres, and compared our results with a theoretical model and prior studies. This thorough evaluation of damage threshold was performed based on irradiation with a 532nm nanosecond-pulsed laser over a range of nanoparticle diameters from 20 to 100nm. Experimentally determined damage thresholds were compared to a theoretical heat transfer model of pulsed laser-irradiated nanoparticles and found to be in reasonably good agreement, although some significant discrepancies with prior experimental studies were found. This study and resultant dataset represent an important foundation for developing a standardized test methodology for determination of laser-induced nanoparticle damage thresholds.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic active mixing nozzle for three-dimensional printing of viscoelastic inks

The present disclosure relates to a device for three-dimensional ink deposition from an impeller-driven active mixing microfluidic printing nozzle. The device is configured to receive a material property associated with the plurality of fluids and receive a structure property of the printing nozzle. The device then determines a threshold relation between a rotating speed .OMEGA. of an impeller in the nozzle and a volumetric flow rate Q of fluids that flow through the nozzle based on the material property of the plurality of fluids, the structure property of the printing nozzle. Based on the threshold relation, the device then determines an actual volumetric flow rate of the fluids and actual rotation speed of the impeller.

Lewis, Jennifer A.↗

Event Reconstruction for Water-based Liquid Scintillator Detectors

Water Cherenkov and liquid scintillator detectors represent two complementary approaches in neutrino physics. Water Cherenkov detectors provide particle track direction and particle identification (PID) through Cherenkov ring topology, while liquid scintillator detectors offer higher light yield and lower energy thresholds. Water-based liquid scintillator (WbLS) is designed to combine the advantages of both technologies. However, the simultaneous detection of Cherenkov and scintillation light by photosensors introduces significant challenges for event reconstruction. This poster presents event reconstruction studies for WbLS detectors. A likelihood-based reconstruction framework, fiTQun, has been successfully used in Super-Kamiokande to reconstruct water Cherenkov events in cylindrical detectors. We extend and improve this framework to demonstrate event reconstruction in WbLS detectors, enabling the concurrent reconstruction of particle energy, PID, vertex, and direction. The results demonstrate competitive performance in energy resolution, PID separation, and vertex and direction reconstruction, highlighting the strong potential of WbLS for next-generation neutrino experiments.

Xie, Zhenxiong [Minnesota U.] (ORCID:0009000301442↗

A new version of the LUPIN detector: Improvements and latest experimental verification

LUPIN-II is an upgraded version of LUPIN, a novel rem counter first developed in 2010 specifically conceived to work in pulsed neutron fields (PNFs). The new version introduces some modifications that improve the performance of the detector, in particular extending its upper detection limit in PNFs. This paper discusses the characteristics and the performance of the instrument. Measurements have been carried out in radiation fields characterized by very different conditions: the detector has first been exposed in PNFs with intensity up to 5 μSv per burst, where it could keep the H*(10) underestimation below 20% up to 500 nSv per burst. It has then been tested in operational conditions around particle accelerators, where it has shown performances similar to that of ionization chambers. Its proper functioning has also been verified in high energy mixed fields, where the experimental results matched the Monte Carlo predictions. Its neutron/photon discrimination capability has been tested in a steady-state photon field where, via an innovative technique based on a threshold set on the derivative of the current signal, it was capable of rejecting a photon H*(10) rate of about 25 mSv/h, and in a mixed neutron/photon field, where a time-based discrimination method was employed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of the stimulated-emission threshold in high-{beta} nanoscale lasers through phase-space reconstruction

Nanoscale lasers sustain a few optical modes so that the fraction of spontaneous emission {beta} funnelled into the useful (lasing) mode is high (of the order of 10{sup -1}) and the threshold, which traditionally corresponds to an abrupt kink in the light-in-light-out curve, becomes ill defined. We propose an alternative definition of the threshold that is based on the dynamical response of the laser and is valid even for {beta}=1 lasers. The laser dynamics is analyzed through a reconstruction of its phase-space trajectory for pulsed excitations. Crossing the threshold, brings about a change in the shape of the trajectory and in the area contained in it. An unambiguous determination of the threshold in terms of this change is shown theoretically and illustrated experimentally in a photonic-crystal laser.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Defining Radiotherapy Target Volumes Using {sup 18}F-Fluoro-Deoxy-Glucose Positron Emission Tomography/Computed Tomography: Still a Pandora's Box?

Purpose: We discuss the effect of {sup 18}F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET)/computed tomography (CT) data on target volume definition for radiotherapy planning. We compared the effect of various thresholding methods on the PET-based target volume vs. the standard CT-based tumor volume. Methods and Materials: Different thresholding methods were reviewed and compared to our PET-based gross tumor volume data obtained from a cohort of 31 non-small-cell lung carcinoma patients who had undergone preoperative PET/CT scans for staging. The feasibility and limitations of FDG-based PET/CT data on target volume delineation in radiotherapy planning have been demonstrated with frequently used approaches for target outlining such as the qualitative visual method and the fixed 15% or 40% of the maximal iso-uptake value threshold methods. Results: The relationship between PET-based and CT-based volumes generally suffers from poor correlation between the two image data sets, expressed in terms of a large statistical variation in gross tumor volume ratios, irrespective of the threshold method used. However, we found that the maximal signal/background ratios in non-small-cell lung carcinoma patients correlated well with the pathologic results, with an average ratio for adenocarcinoma, large cell carcinoma, and squamous cell carcinoma of 10.5 {+-} 3.5, 12.6 {+-} 2.8, and 14.1 {+-} 5.9, respectively. Conclusion: The fluctuations in tumor volume using different quantitative PET thresholding approaches did not depend on the thresholding method used. They originated from the nature of functional imaging in general and PET imaging in particular. Functional imaging will eventually be used for biologically tailored target radiotherapy volume definition not as a replacement of CT- or magnetic resonance imaging-based anatomic gross tumor volumes but with the methods complementing each other in a complex mosaic of distinct biologic target volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-564: 3 Year Experience of Treatment Plan QualityAssurance for Vero SBRT Patients

Purpose: To verify treatment plan monitor units from iPlan treatment planning system for Vero Stereotactic Body Radiotherapy (SBRT) treatment using both software-based and (homogeneous and heterogeneous) phantom-based approaches. Methods: Dynamic conformal arcs (DCA) were used for SBRT treatment of oligometastasis patients using Vero linear accelerator. For each plan, Monte Carlo calculated treatment plans MU (prescribed dose to water with 1% variance) is verified first by RadCalc software with 3% difference threshold. Beyond 3% differences, treatment plans were copied onto (homogeneous) Scanditronix phantom for non-lung patients and copied onto (heterogeneous) CIRS phantom for lung patients and the corresponding plan dose was measured using a cc01 ion chamber. The difference between the planed and measured dose was recorded. For the past 3 years, we have treated 180 patients with 315 targets. Out of these patients, 99 targets treatment plan RadCalc calculation exceeded 3% threshold and phantom based measurements were performed with 26 plans using Scanditronix phantom and 73 plans using CIRS phantom. Mean and standard deviation of the dose differences were obtained and presented. Results: For all patient RadCalc calculations, the mean dose difference is 0.76% with a standard deviation of 5.97%. For non-lung patient plan Scanditronix phantom measurements, the mean dose difference is 0.54% with standard deviation of 2.53%; for lung patient plan CIRS phantom measurements, the mean dose difference is −0.04% with a standard deviation of 1.09%; The maximum dose difference is 3.47% for Scanditronix phantom measurements and 3.08% for CIRS phantom measurements. Conclusion: Limitations in secondary MU check software lead to perceived large dose discrepancies for some of the lung patient SBRT treatment plans. Homogeneous and heterogeneous phantoms were used in plan quality assurance for non-lung patients and lung patients, respectively. Phantom based QA showed the relative good agreement between iPlan calculated dose and measured dose.

60 APPLIED LIFE SCIENCES↗

Development of coherent germanium neutrino technology (CoGeNT) for reactor safeguards

Antineutrinos are extremely penetrating elementary particles that have unique features of interest for safeguards at nuclear reactors. Current antineutrino detectors systems have large size and often use hazardous materials, presenting concerns to the safeguards agencies. We propose a new antineutrino detector, based on HPGe detector technology, which is much smaller and safer and therefore more likely to find widespread acceptance as a monitoring tool. The proposed system should be sensitive to a universally predicted but as-yet undetected antineutrino signature, the coherent neutrino-nucleus scattering, for which an unprecedentedly low noise threshold is required. Based on the noise analysis of an existing HPGe detector and the results of noise tests, a new system was designed and fabricated in collaboration with LBNL, though a full noise optimization has not been possible. Shielding design has been analyzed in the context of other deployment results, and an anticoincidence veto with high neutron efficiency has been tested.

Cabrera-Palmer, Belkis↗

H2@Scale: Economic Potential of Hydrogen as an Energy Intermediate

The H2@Scale concept envisions hydrogen as an energy intermediate across multiple energy sectors. The concept is motivated both by the opportunity to produce hydrogen from low-cost energy resources, and by the many potential applications of hydrogen, including as energy for transportation - used directly in fuel cell electric vehicles (FCEVs), as a feedstock for synthetic fuels, and to upgrade oil and biomass - feedstock for industry (e.g., for ammonia production, metals refining, and other end uses), heat for industry and buildings, and electricity storage. A key hydrogen production opportunity is using variable renewable electricity (i.e., electricity generated by wind turbines or solar photovoltaic panels) during hours when generation exceeds the load on the grid as a source of low-cost, dispatch constrained electricity (LDE). In addition to producing low-cost hydrogen, electrolysis can also serve as a form of responsive load on the electric grid, which can enhance grid stability, reduce curtailment, and create a supplementary revenue stream for generators. The future use and adoption of hydrogen across end-use applications depends both the cost of hydrogen production and on each application's threshold price (i.e., the maximum price each application will pay for hydrogen - above that price, the application has an alternative that is more economic). We estimate economic potential of the hydrogen market - the quantity of hydrogen at an equilibrium price at which suppliers are willing to produce and consumers are willing to buy the same quantity of hydrogen - by developing supply and demand curves for hydrogen production and use. The demand curves are based on the threshold price for various quantities of hydrogen in each market, which is affected by projected prices for alternatives that could provide the same service (e.g., fuel for vehicles, feedstock for metals refining). The supply curves include hydrogen produced via natural gas steam methane reforming, high-temperature electrolysis coupled with nuclear power plants, biomass gasification, and low-temperature electrolysis using LDE. We use a range of market and technology-advancement assumptions to estimate the economic potential for five scenarios in the mid 21st century timeframe, and the corresponding impacts on energy use and emissions. We estimate hydrogen's economic potential to be 14-48 MMT/yr in the contiguous United States - corresponding to 1.5-5 times current annual consumption - depending on key assumptions about the future market conditions and the success of hydrogen production research and development (R&D) in our five scenarios. As a result of the estimated economic potential markets, we also approximate that grid-integrated electrolysis can increase the penetration of wind generation in the electricity market by providing a value stream for LDE, and that total U.S. fossil fuel use could decline below a scenario with high renewable penetration on the grid. We find that hydrogen has potential to provide technical and economic synergies when integrated across multiple sectors of the U.S. energy system, but continued R&D, infrastructure, and market development for LDE are required.

08 HYDROGEN↗

Geometry-Driven Detection, Tracking and Visual Analysis of Viscous and Gravitational Fingers

Viscous and gravitational flow instabilities cause a displacement front to break up into finger-like fluids. The detection and evolutionary analysis of these fingering instabilities are critical in multiple scientific disciplines such as fluid mechanics and hydrogeology. However, previous detection methods of the viscous and gravitational fingers are based on density thresholding, which provides limited geometric information of the fingers. The geometric structures of fingers and their evolution are important yet little studied in the literature. In this work, we explore the geometric detection and evolution of the fingers in detail to elucidate the dynamics of the instability. Additionally, we propose a ridge voxel detection method to guide the extraction of finger cores from three-dimensional (3D) scalar fields. After skeletonizing finger cores into skeletons, we design a spanning tree based approach to capture how fingers branch spatially from the finger skeletons. Finally, we devise a novel geometric-glyph augmented tracking graph to study how the fingers and their branches grow, merge, and split over time. Feedback from earth scientists demonstrates the usefulness of our approach to performing spatio-temporal geometric analyses of fingers.

97 MATHEMATICS AND COMPUTING↗

Pellet-Cladding Mechanical Interaction Failure Threshold for Reactivity Initiated Accidents for Pressurized Water Reactors and Boiling Water Reactors

Pacific Northwest National Laboratory (PNNL) has been requested by the U.S. Nuclear Regulatory Commission to evaluate the reactivity initiated accident (RIA) tests that have recently been performed in the Nuclear Safety Research Reactor (NSRR) and CABRI (French research reactor) on uranium dioxide (UO 2 ) and mixed uranium and plutonium dioxide (MOX) fuels, and to propose pellet-cladding mechanical interaction (PCMI) failure thresholds for RIA events. This report discusses how PNNL developed PCMI failure thresholds for RIA based on least squares (LSQ) regression fits to the RIA test data from cold-worked stress relief annealed (CWSRA) and recrystallized annealed (RXA) cladding alloys under pressurized water reactor (PWR) hot zero power (HZP) conditions and boiling water reactor (BWR) cold zero power (CZP) conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Observer POD for radiographic testing

The radiographic testing (RT) is a non-destructive testing (NDT) method capable of finding volumetric and open planar defects depending on their orientation. The radiographic contrast is higher for larger penetrated length of the defect in a component. Even though, the detectability of defects does not only depend on the contrast, but also on the noise, the defect area and the geometry of the defect. The currently applied Probability of Detection (POD) approach uses a detection threshold that is only based on a constant noise level or on a constant contrast threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the lateral area and shape of the indication. This work shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data of different defect types, such as ASTM E 476 EPS plates, flat bottom holes and notches. Additional experiments with different operators confirm that the depth of a defect, the lateral area and shape of its indication contribute with different weight to the detectability of the defect if evaluated by human operators on monitors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Particle Number Concentrations for HI-SCALE Field Campaign Report

In support of the Holistic Interactions of Shallow Clouds, Aerosols, and Ecosystems (HI-SCALE) project to study new particle formation in the atmosphere, a pair of custom water condensation particle counters were provided to the second intensive field campaign, from mid-August through mid-September 2017, at the U.S. Department of Energy Southern Great Plains Atmospheric Radiation Measurement (ARM) Climate Research Facility observatory. These custom instruments were developed by Aerosol Dynamics, Inc. (Hering et al. 2017) to detect particles into the nanometer size range. Referred to as “versatile water condensation particle counter (vWCPC)”, they are water-based, laminar-flow condensational growth instruments whose lower particle size threshold can be set based on user-selected operating temperatures. For HI-SCALE, the vWCPCs were configured to measure airborne particle number concentrations in the size range from approximately 2nm to 2μm. Both were installed in the particle sizing system operated by Chongai Kuang of Brookhaven National Laboratory (BNL). One of these was operated in parallel to a TSI Model 3776, upstream of the mobility particle sizing system, to measure total ambient particle concentrations. The airborne particle concentration data from this “total particle number vWCPC” (Ntot-vWCPC) system has been reported to the ARM database. The data are reported with one-second resolution. The second vWCPC was operated in parallel with the BNL diethylene glycol instrument to count particles downstream of a separate differential mobility size analyzer. Data from this “DMA-vWCPC” system was logged by BNL, and will eventually be provided by that laboratory.

HI-SCALE, aerosol particle number concentration, v↗

A prediction model of failure threshold for shear deformation in a Zr-based bulk metallic glass

The failure of bulk metallic glasses (BMGs) during plastic deformation at room temperature is abrupt and instantaneous, while the analysis of precursor information based on avalanche events helps predict catastrophic failure. An acoustic emission (AE) signal can provide accurate precursor information for material failure, due to its sensitive and high fast calculation ability. In the current study, AE monitoring tests are carried out during uniaxial compression tests of BMGs at different strain rates. The AE experimental failure threshold, E max , is proposed on the basis of AE cumulative energy, which reflects the intensity of damage evolution at different loading conditions. Compared with the critical shear band velocity (CSBV) associated with stick-slip dynamics of serrated flow, E max is a more sensitive failure parameter since it is connected with the local microscopic changes that occur during the material response process. Here, the E max is obtained prior to reaching the CSBV since the calculation of these two avalanches analysis focuses on the different stages of shear band growth. In particular, AE events are related to the “dry” friction process in the first stage, however, the CSBV is responsible for the “viscous” glide in the second stage. Therefore, Emax is not affected by the complex interactions between the shear bands during the stick-slip process. The maximum avalanche of serrated flow, S max , is proposed as the experimental failure threshold, which depends on the applied strain rate as S max ~ $\dot{ε}$ –λ . According to the relationship of E max and S max , the theoretical failure threshold, E max , follows a criterion E max = 2545$\dot{ε}$ –λ - 4468, where λ is equivalent to 0.15 for this work. Finally, combining the different calculations and AE measurements, this model gives new insights to predict the deformation failure behavior of Zr-based BMGs.

36 MATERIALS SCIENCE↗

SU-E-J-219: A Dixon Based Pseudo-CT Generation Method for MR-Only Radiotherapy Treatment Planning of the Pelvis and Head and Neck

Purpose: To develop an image processing method for MRI-based generation of electron density maps, known as pseudo-CT (pCT), without usage of model- or atlas-based segmentation, and to evaluate the method in the pelvic and head-neck region against CT. Methods: CT and MRI scans were obtained from the pelvic region of four patients in supine position using a flat table top only for CT. Stratified CT maps were generated by classifying each voxel based on HU ranges into one of four classes: air, adipose tissue, soft tissue or bone.A hierarchical region-selective algorithm, based on automatic thresholding and clustering, was used to classify tissues from MR Dixon reconstructed fat, In-Phase (IP) and Opposed-Phase (OP) images. First, a body mask was obtained by thresholding the IP image. Subsequently, an automatic threshold on the Dixon fat image differentiated soft and adipose tissue. K-means clustering on IP and OP images resulted in a mask that, via a connected neighborhood analysis, allowing the user to select the components corresponding to bone structures.The pCT was estimated through assignment of bulk HU to the tissue classes. Bone-only Digital Reconstructed Radiographs (DRR) were generated as well. The pCT images were rigidly registered to the stratified CT to allow a volumetric and voxelwise comparison. Moreover, pCTs were also calculated within the head-neck region in two volunteers using the same pipeline. Results: The volumetric comparison resulted in differences <1% for each tissue class. A voxelwise comparison showed a good classification, ranging from 64% to 98%. The primary misclassified classes were adipose/soft tissue and bone/soft tissue. As the patients have been imaged on different table tops, part of the misclassification error can be explained by misregistration. Conclusion: The proposed approach does not rely on an anatomy model providing the flexibility to successfully generate the pCT in two different body sites. This research is founded by ZonMw IMDI Programme, project name: “RASOR sharp: MRI based radiotherapy planning using a single MRI sequence”, project number: 10-104003010.

60 APPLIED LIFE SCIENCES↗

High Performance Computing Based Parallel HIearchical Modal Association Clustering (HPAR HMAC)

For many applications, clustering is a crucial step in order to gain insight into the makeup of a dataset. The best approach to a given problem often depends on a variety of factors, such as the size of the dataset, time restrictions, and soft clustering requirements. The HMAC algorithm seeks to combine the strengths of 2 particular clustering approaches: model-based and linkage-based clustering. One particular weakness of HMAC is its computational complexity. HMAC is not practical for mega-scale data clustering. For high-definition imagery, a user would have to wait months or years for a result; for a 16-megapixel image, the estimated runtime skyrockets to over a decade! To improve the execution time of HMAC, it is reasonable to consider an multi-core implementation that utilizes available system resources. An existing imple-mentation (Ray and Cheng 2014) divides the dataset into N partitions - one for each thread prior to executing the HMAC algorithm. This implementation benefits from 2 types of optimization: parallelization and divide-and-conquer. By running each partition in parallel, the program is able to accelerate computation by utilizing more system resources. Although the parallel implementation provides considerable improvement over the serial HMAC, it still suffers from poor computational complexity, O(N2). Once the maximum number of cores on a system is exhausted, the program exhibits slower behavior. We now consider a modification to HMAC that involves a recursive partitioning scheme. Our modification aims to exploit divide-and-conquer benefits seen by the parallel HMAC implementation. At each level in the recursion tree, partitions are divided into 2 sub-partitions until a threshold size is reached. When the partition can no longer be divided without falling below threshold size, the base HMAC algorithm is applied. This results in a significant speedup over the parallel HMAC.

Patlolla, Dilip R↗

Low Group Delay Dispersion Optical Coating for Broad Bandwidth High Reflection at 45° Incidence, P Polarization of Femtosecond Pulses with 900 nm Center Wavelength

We describe an optical coating design suitable for broad bandwidth high reflection (BBHR) at 45° angle of incidence (AOI), P polarization (Ppol) of femtosecond (fs) laser pulses whose wavelengths range from 800 to 1000 nm. The design process is guided by quarter-wave HR coating properties. Our design must afford low group delay dispersion (GDD) for reflected light over the broad, 200 nm bandwidth in order to minimize temporal broadening of the fs pulses due to dispersive alteration of relative phases between their frequency components. The design should also be favorable to high laser-induced damage threshold (LIDT). We base the coating on TiO 2 /SiO 2 layer pairs produced by means of e-beam evaporation with ion-assisted deposition, and use OptiLayer Thin Film Software to explore designs starting with TiO 2 /SiO 2 layers having thicknesses in a reverse chirped arrangement. This approach led to a design with R > 99% from 800 to 1000 nm and GDD < 20 fs 2 from 843 to 949 nm (45° AOI, Ppol). The design’s GDD behaves in a smooth way, suitable for GDD compensation techniques, and its electric field intensities show promise for high LIDTs. Reflectivity and GDD measurements for the initial test coating indicate good performance of the BBHR design. Subsequent coating runs with improved process calibration produced two coatings whose HR bands satisfactorily meet the design goals. Lastly, for the sake of completeness, we summarize our previously reported transmission spectra and LIDT test results with 800 ps, 8 ps and 675 fs pulses for these two coatings, and present a table of the LIDT results we have for all of our TiO 2 /SiO 2 BBHR coatings, showing the trends with test laser pulse duration from the ns to sub-ps regimes.

36 MATERIALS SCIENCE↗