Search NASA⌕ Search

SEARCH · Search NASA

Results for “time synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Electric Six Degree of Freedom Installation Timelapse (Six Degree of Freedom Dynamic Test System)

The Six-degree-of-freedom Dynamic Test System (SDTS) is a short-range real-time motion based testing platform. Its primary use at NASA/JSC has been for development and qualification testing of docking systems, robotic assisted berthing mechanisms, and dynamic attachment systems. The SDTS is a closed-loop force feedback system that can simulate on-orbit contact dynamics between two vehicles utilizing the actual mechanical interfaces for testing. The facility is controlled by interconnected computers running real-time simulation software that takes measured contact forces, integrates the equations of motion in real time, and provide those states back into the motion table. This infrastructure can also be used for non-mating applications such as relative position sensor testing/evaluations. The SDTS facility provides a superstructure for mounting test articles, multiple test sensors, an intercom network for voice communications, and a synchronized timing system for data acquisition that includes HD video. This time-lapse video shows the buildup and testing of a modern electric actuation system created by Mikrolar, Inc. at the Johnson Space Center. This motion base will replace the current hydraulic actuator system, which is been in use since the 1970s, for all-future NASA testing. Once the system goes through customization to provide JSC’s unique closed-loop environment, the facility will help certify docking system and attach mechanisms on the ground before we send the first woman and the next man to the lunar surface

hexapod↗

Using GPS Receiver 1PPS Output to Verify Time Stamp Accuracy and Measure Propagation Delay

A simple pulse overlay circuit using a logic OR gate was developed to overlay a precise leading edge 1 pulse per second time reference marker from a global positioning system receiver onto a non-return -to- zero-level pulse code modulation telemetry data stream to validate time stamp accuracy and measure propagation delay in telemetry equipment. A pulse overlay (PO) circuit was designed to produce a time reference marker within a pulse code modulation (PCM) telemetry data stream that was recorded and analyzed to validate an IRIG Standard 106-17 Chapter 10 recorder’s time stamp accuracy [1]. A manufacturer of a newly purchased Chapter 10 recorder claimed the time stamp accuracy to be better than 10 microseconds (μs) with only IRIG-B120 (IRIG-B) input and better than 1 μs with IRIG-B and one pulse per second (1PPS) inputs. The PO circuit and a Chapter 10 recorder test setup were used to verify the vendor’s data-time synchronization claims and to justify infrastructure upgrade costs to connect additional cables to each purchased recorder. The circuit was also used to measure the propagation delay (PD) of a long distance Telemetry multiplexer/demultiplexer telecommunication system which the manufacturer did not provide a PD specification. Using the one pulse per second time reference marker of the global positioning system receiver and the pulse overlay circuit to overlay the one pulse per second variable pulse width signal into a pulse code modulation telemetry stream provided an excellent means to validate time stamp accuracy within a Chapter 10 recorder and to measure propagation delays within a normal telemetry operating environment. The positive results from the Chapter 10 recorder tests validated the vendor’s claims and justified the implementation to add the one pulse per second signal to the range Chapter 10 recorders. The pulse overlay circuit and test setups defined in this paper can easily be used to measure other telemetry equipment.

Knudtson, Kevin↗

Time and frequency comparisons in Europe by means of ECS 5 geostationary satellite

A time synchronization experiment between some European laboratories using the passive television method applied to the signals broadcasted by Eutelsat I-F5 telecommunication satellite was completed in 1990. The results obtained in the last period, when also range measurements from a Telespazio ground station were performed, are analyzed to evaluate the accuracy level of the time comparisons corrected for the effect of the satellite movement with position data obtained either from the European Space Agency (ESA) or from orbit determination with range data entered into GEODYN program of NASA/GSFC.

Cordara, Franco↗

Time and Laser Ranging: A Window of Opportunity for Geodesy, Navigation, and Meteorology

Recent progress in the domain of time and frequency (T/F) standards requires important improvements in existing timedistribution links, in term of accuracy in particular. Satellite Laser Ranging (SLR) has proven to be a fundamental tool,offering a straightforward, conceptually simple, highly accurate, and unambiguous observable. Several time transfers by laserlink projects have been carried out over the past 10 years with numerous scientific and metrological objectives. Depending on the mission, SLR is used to transmit time over two-way or one-way distances from 500 to several millions of kilometers.The following missions and their objectives employed this technique: European Laser Timing (ELT, expected in 2020) at 450 km, Time Transfer by Laser Link (T2L2) at 1336 km, Laser Time Transfer at 36,000 km, Lunar Reconnaissance Orbiter at 350,000 km, and MErcury Surface, Space ENvironment, GEochemistry, and Ranging at tens of million km. This article describes the synergy between SLR and T/F technologies developed on the ground and in space and as well as the state of the art of their exploitation. The performance and sources of limitation of such space missions are analyzed. It shows that currentand future challenges lie in the improvement in the time accuracy and stability of the time for ground geodetic observatories.The role of the next generation of SLR systems is emphasized both in space and at ground level, from the point of view of Global Geodetic Observing System and valuable exploitation of the synergy between time synchronization, ranging, and data transfer.

Laser ranging↗

Using Pulsars For Clock Steering and Time Transfer

As we prepare for extended missions on the Moon and in cislunar space, precise time synchronization between lunar and terrestrial clocks becomes increasingly critical for navigation, communication, and science measurements. One promising technique is the use of millisecond pulsars, which are highly magnetized, rapidly rotating neutron stars emitting beams of electromagnetic radiation. These celestial clocks offer extraordinary stability and precision, with rotational periods ranging from about 1 to 10 milliseconds and timing stability comparable to laboratory atomic clocks on Earth. Pulsars can provide a common time reference for clock comparisons, allowing time transfer independent of a communications link.

Spacecraft Communications, Command and Tracking↗

Development of the ISS EMU Dashboard Software

The EMU (Extra-Vehicular Mobility Unit) Dashboard was developed at NASA s Johnson Space Center to aid in real-time mission support for the ISS (International Space Station) and Shuttle EMU space suit by time synchronizing down-linked video, space suit data and audio from the mission control audio loops. Once the input streams are synchronized and recorded, the data can be replayed almost instantly and has proven invaluable in understanding in-flight hardware anomalies and playing back information conveyed by the crew to missions control and the back room support. This paper will walk through the development from an engineer s idea brought to life by an intern to real time mission support and how this tool is evolving today and its challenges to support EVAs (Extra-Vehicular Activities) and human exploration in the 21st century.

Bernard, Craig↗

Entangled Photon Pair Source Demonstrator Using the Quantum Instrumentation Control Kit System

Here, we report the first demonstration of using the Quantum Instrumentation and Control Kit (QICK) system on RFSoC-FPGA technology to drive the electro-optic intensity modulator that generate time-bin entangled photon pairs and to detect the photon signals. With the QICK system, we achieve high levels of performance metrics including coincidence-to-accidental ratio exceeding 150, and entanglement visibility exceeding 95%, consistent with performance metrics achieved using conventional waveform generators. We also demonstrate simultaneous detector readout using the digitization functional of QICK, achieving internal system synchronization time resolution of 3.2 ps. The work reported in this paper represents an explicit demonstration of the feasibility for replacing commercial waveform generators and time taggers with RFSoC-FPGA technology in the operation of a quantum network, representing a cost reduction of more than an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Point Cloud of Cloud Points (PCCP) Value-Added Product Report

In this report, we refer to a pair of cameras that capture synchronized pictures with overlapping fields of view (FOV) as a stereo pair. Each stereo pair independently performs a stereo reconstruction of cloud points. Currently, there are three U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility stereo pairs (six cameras in total) positioned around the Southern Great Plains (SGP) observatory’s Central Facility (CF; Romps and Oktem 2017). Time-synchronized pictures from the two cameras in a stereo pair can be paired together to obtain a three-dimensional (3D) reconstruction of feature points by triangulation. This document explains how we use ARM stereo cameras and stereophotogrammetric principles to generate the Point Cloud of Cloud Points (PCCP) Value-Added Product (VAP). The PCCP VAP is essentially a set of 3D positions representing the locations of cloud features in the sky. Thousands of cloud features can be reconstructed instantly in each stereo pair's FOV, which covers an area of tens of square kilometers. Cloud base and cloud top heights can be extracted from the PCCP product.

54 ENVIRONMENTAL SCIENCES↗

Retrieving Point Cloud of Cloud Points (PCCP) Value-Added Product from Stereo Cameras

In this report, we refer to a pair of cameras that capture synchronized pictures with overlapping fields of view (FOV) as a stereo pair. Each stereo pair independently performs a stereo reconstruction of cloud points. Currently, there are three U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility stereo pairs (six cameras in total) positioned around the Southern Great Plains (SGP) observatory’s Central Facility (CF; Romps and Oktem 2017). Time-synchronized pictures from the two cameras in a stereo pair can be paired together to obtain a three-dimensional (3D) reconstruction of feature points by triangulation. This document explains how we use ARM stereo cameras and stereophotogrammetric principles to generate the Point Cloud of Cloud Points (PCCP) Value-Added Product (VAP). The PCCP VAP is essentially a set of 3D positions representing the locations of cloud features in the sky. Thousands of cloud features can be reconstructed instantly in each stereo pair's FOV, which covers an area of tens of square kilometers. Cloud base and cloud top heights can be extracted from the PCCP product.

42 ENGINEERING↗

Cause identification of electromagnetic transient events using spatiotemporal feature learning

This paper presents a spatiotemporal feature learning method for cause identification of electromagnetic transient events in power grids. The proposed method is formulated based on the availability of time-synchronized high-frequency measurements and using the convolutional neural network as the spatiotemporal feature representation along with softmax function for the classification. Despite the existing threshold-based, or energy-based events analysis methods, such as support vector machine autoencoder, and tapered multi-layer perceptron neural network, the proposed feature learning is carried out with respect to both time and space. The effectiveness of the proposed feature learning and the subsequent cause identification is validated through the Electromagnetic Transients Program (EMTP) simulation of different events such as line energization, capacitor bank energization, lightning, fault, and high-impedance fault in the IEEE 30-bus, and the real-time digital simulation of the Western System Coordinating Council (WSCC) 9-bus system.

42 ENGINEERING↗

Synchrophasor spoofing detection and remediation for wide-area damping control

Evolving cyber-attack threats put at risk automatic closed-loop systems to be incorporated in the smart grid. Wide-area control systems are particularly vulnerable to signal spoofing attacks due to sensor remoteness and dependence on satellite communication for time synchronization. A successful cyber-attack on a wide-area controller has the potential to reduce relative stability of the power system or worse, destabilize it. As such, detection algorithms must be deployed as defense against such attacks with the ability to autonomously correct for detected tampering or misoperation. The Spoof Catch and Restore Routine (SCR 2 ), a combination of three real-time spoof detectors, each requiring limited information about the plant, is reported here. Nonlinear simulations of a compromised wide-area control system deployed in the Western Interconnection show the effectiveness of SCR 2 in detecting both delay-type and counterfeit-type spoofing attacks on wide-area sensors.

42 ENGINEERING↗

GPS signal loss in the wide area monitoring system: Prevalence, impact, and solution

The phasor measurement unit (PMUs), equipped with Global Positioning System (GPS) receivers for precise time synchronization, provides measurements of voltage and current phasors at different nodes of the wide area monitoring system. However, GPS receivers are likely to lose satellite signals due to various unpredictable factors. The prevalence of GPS signal loss (GSL) on PMUs is first investigated using real PMU data. The historical GSL events are extracted from a phasor data concentrator (PDC) and FNET/GridEye server. The correlation between GSL and time, spatial location, solar activity are explored via comprehensive statistical analysis. Furthermore, the impact of GSL on phasor measurement accuracy has been studied via experiments. Finally, several potential solutions to mitigate the impact of GSL on PMUs are discussed and compared.

47 OTHER INSTRUMENTATION↗

A Strategy for Forced Oscillation Suppression

Wide-area time-synchronized measurements have recently revealed troublesome forced oscillations (FOs) within modern synchronized power grids. In some cases, these FOs represent a dangerous hazard to the system. Recent research has focused on locating the source of FOs to provide operators with knowledge for mitigating their impact locally. This paper presents a complementary mitigation strategy, which is to purposely induce a second oscillation into the grid which cancels the impact of the FO. Such a strategy is complementary in that it may provide valuable time to operators attempting to locate the FOs source and to determine how to rectify it. This paper presents a suppression control strategy which modulates controllable devices to automatically cancel the impact of the FO without the need for locating the source of the original FO. The strategy is based upon tuned feedback control. In this study, the approach is demonstrated on a simulation system via modulation of inverter-based generation.

42 ENGINEERING↗

Stability and noise spectra of relative Loran-C frequency comparisons

Relative comparisons of Loran-C frequency transmissions between the master station of Catanzaro (Simeri Crichi) and the X, Z slave stations of Estartit (Spain) and Lampedusa (Italy) are carrying out by the GG LORSTA monitor station of the Mediterranean Sea Loran-C chain. These comparisons are able to emphasize the relative and, under certain conditions, the absolute rate of the emitting standard frequencies of the slave stations and some relevant statistical properties of the Loran-C Method for frequency transmission and time synchronization. The stability of each Loran-C frequency standard transmission is subject to perturbations, more or less known, due to the propagation medium and other causes. Following the Allan (1966) method for data processing, the performance of the relative rate of frequency of the transmissions of the X, Z slave stations are described calculating the standard deviation of a set of N frequency measurements from its mean averaged during sampling times. This standard deviation is designated as the measure of the stability of the Loran-C frequency transmission.

Proverbio, E.↗

Implications of Wide-Area Geographic Diversity for Short- Term Variability of Solar Power

Worldwide interest in the deployment of photovoltaic generation (PV) is rapidly increasing. Operating experience with large PV plants, however, demonstrates that large, rapid changes in the output of PV plants are possible. Early studies of PV grid impacts suggested that short-term variability could be a potential limiting factor in deploying PV. Many of these early studies, however, lacked high-quality data from multiple sites to assess the costs and impacts of increasing PV penetration. As is well known for wind, accounting for the potential for geographic diversity can significantly reduce the magnitude of extreme changes in aggregated PV output, the resources required to accommodate that variability, and the potential costs of managing variability. We use measured 1-min solar insolation for 23 time-synchronized sites in the Southern Great Plains network of the Atmospheric Radiation Measurement program and wind speed data from 10 sites in the same network to characterize the variability of PV with different degrees of geographic diversity and to compare the variability of PV to the variability of similarly sited wind. The relative aggregate variability of PV plants sited in a dense 10 x 10 array with 20 km spacing is six times less than the variability of a single site for variability on time scales less than 15-min. We find in our analysis of wind and PV plants similarly sited in a 5 x 5 grid with 50 km spacing that the variability of PV is only slightly more than the variability of wind on time scales of 5-15 min. Over shorter and longer time scales the level of variability is nearly identical. Finally, we use a simple approximation method to estimate the cost of carrying additional reserves to manage sub-hourly variability. We conclude that the costs of managing the short-term variability of PV are dramatically reduced by geographic diversity and are not substantially different from the costs for managing the short-term variability of similarly sited wind in this region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hawaii Wave Surge Energy Converter (HAWSEC) OSU O.H. Hinsdale Basin

The following information and metadata applies to both the Phase I (Hydrodynamics) and Phase II (Full System Power Take-Off) zip folders which contain testing data from the OSU (Oregon State University) O.H. Hinsdale Wave Research Laboratory, from both OSU and the University of Hawaii at Manoa (UH). See zip folders provided further below in the downloads section. For experimental data of the full system, including PTO, see Phase II dataset. There are two main directories in each Phases's zip folder: "OSU_data" and "UH_data". The "OSU_data" directory contains data collected from their DAQ (data acquisition system), which includes all wave gauge observations, as well as body motions derived from their Qualisys motion tracking system. The organization of the directory follows OSU's convention. Detailed information on the instrument setup can be found under "OSU_data/docs/setup/instm_locations". The experiments conducted are documented in the "OSU_data/docs/daq_logs", which provides the trial number to the corresponding data located under "OSU_data/data" in several formats (e.g., ".mat" and ".txt"). Inside the trial directory, data is provided for each of the instruments defined in "OSU_data/docs/setup/instm_locations". The "UH_data" directory contains data collected from their DAQ. The data is stored in a ".tdms" file format. There are free plug-ins for Microsoft Excel and MathWorks MATLAB to read the ".tdms" format. Below are a few links providing methods to read in the data, but a Google search should identify alternatives sources if these no longer exist (valid as of January 2024): Excel: http://www.ni.com/example/27944/en/ MATLAB: https://www.mathworks.com/matlabcentral/fileexchange/30023-tdms-reader The Excel plugin is recommend to get a quick overview of the data. The UH data is organized by directory name, in which the sub-directories for each experiment contains a directory whose name defines the wave height and period for the experimental data within. For example, a directory name "H02_T0275" corresponds to an experiment with wave height 0.1m and a period of 2.75s. For random wave data, the gamma value is also included in the directory name. For example, a directory name "H02_T0225_G18" corresponds to an experiment with a significant wave height of 0.2m, a peak period of 2.25s, and a gamma value of 1.8, with each spectra being a TMA spectrum. For the free decay experiments, the directory name is defined by the initial angular displacement. For example, a directory name "ang05_run01" corresponds to an experiment with an initial angular displacement of 5 degrees. There is a dataset in the UH data for each corresponding experiment defined in the OSU DAQ logs. The ".tdms" data is output from the DAQ at fixed intervals. Therefore, if multiple files are contained within the folder, the data will need to be stitched together. Within the UH dataset, there are two input channels from the OSU DAQ providing a random square wave signal for time synchronization ("ENV-WHT-0010") and a high/low signal ("ENV-WHT-0012") to identify when the wave maker is active (+5V). The UH data is logged as a collection of channel outputs. Channels not in use for the OSU testing (either Phase I or Phase II) are marked "nan" below. If the sensor is disconnected, it will record noise throughout the experiment. Below are the channel definitions in terms of what they measure: GPS Time = time CYL-POS-0001 = position between flap and fixed reference CYL-LCA-0001 = force between flap and hydraulic cylinder REC-LPT-0001 = nan REC-HPT-0001 = nan REC-HPT-0002 = nan REC-HPT-0003 = nan HHT-HPT-0001 = pressure at exhaust ("head" only) REC-FQC-0001 = nan REC-FQC-0002 = nan HHT-FQC-0001 = flow at exhaust ("head" only) ENV-WHT-0001 = nan ENV-WHT-0002 = nan ENV-WHT-0003 = nan ENV-WHT-0010 = random signal from OSU DAQ ENV-WHT-0012 = high/low signal from OSU DAQ Also included is a calibration curve to convert the string pot data to flap pi...

16 TIDAL AND WAVE POWER↗

Clock synchronization experiments performed via the ATS-1 and ATS-3 satellites.

Clock synchronization experiments were carried out May 10 to June 10, 1971, via the ATS-1 and ATS-3 geostationary satellites between the NASA tracking stations at Rosman, N.C., and Mojave, Calif., in order to determine the offset and the relative drift rate between the two station clocks. Pulses at C band with very sharp risetime and of 10 microsec duration were exchanged by the two stations through the dual transponders of the satellites. At each station, a time-interval counter was started by the transmitted pulse and stopped by the pulse received via satellite from the other station. The probable error of the clock offset as measured by the counter is 10 msec. A very long baseline interferometer experiment was also performed between the two stations at the same time and provided independent clock-offset data to check the accuracy of the time-synchronization experiment.

Ramasastry, J.↗

Accurate Time/Frequency Transfer Method Using Bi-Directional WDM Transmission

An accurate time transfer method is proposed using b-directional wavelength division multiplexing (WDM) signal transmission along a single optical fiber. This method will be used in digital telecommunication networks and yield a time synchronization accuracy of better than 1 ns for long transmission lines over several tens of kilometers. The method can accurately measure the difference in delay between two wavelength signals caused by the chromatic dispersion of the fiber in conventional simple bi-directional dual-wavelength frequency transfer methods. We describe the characteristics of this difference in delay and then show that the accuracy of the delay measurements can be obtained below 0.1 ns by transmitting 156 Mb/s times reference signals of 1.31 micrometer and 1.55 micrometers along a 50 km fiber using the proposed method. The sub-nanosecond delay measurement using the simple bi-directional dual-wavelength transmission along a 100 km fiber with a wavelength spacing of 1 nm in the 1.55 micrometer range is also shown.

Imaoka, Atsushi↗