Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Evaluating the Potential and Challenges of an Uncertainty Quantification Method for Long Short–Term Memory Models for Soil Moisture Predictions

Recently, recurrent deep networks have shown promise to harness newly available satellite–sensed data for long–term soil moisture projections. However, to be useful in forecasting, deep networks must also provide uncertainty estimates. Here we evaluated Monte Carlo dropout with an input–dependent data noise term (MCD+N), an efficient uncertainty estimation framework originally developed in computer vision, for hydrologic time series predictions. MCD+N simultaneously estimates a heteroscedastic input–dependent data noise term (a trained error model attributable to observational noise) and a network weight uncertainty term (attributable to insufficiently constrained model parameters). Although MCD+N has appealing features, many heuristic approximations were employed during its derivation, and rigorous evaluations and evidence of its asserted capability to detect dissimilarity were lacking. To address this, we provided an in–depth evaluation of the scheme's potential and limitations. We showed that for reproducing soil moisture dynamics recorded by the Soil Moisture Active Passive (SMAP) mission, MCD+N indeed gave a good estimate of predictive error, provided that we tuned a hyperparameter and used a representative training data set. The input–dependent term responded strongly to observational noise, while the model term clearly acted as a detector for physiographic dissimilarity from the training data, behaving as intended. However, when the training and test data were characteristically different, the input–dependent term could be misled, undermining its reliability. Additionally, due to the data–driven nature of the model, data noise also influences network weight uncertainty, and therefore the two uncertainty terms are correlated. Altogether, this approach has promise, but care is needed to interpret the results.

54 ENVIRONMENTAL SCIENCES↗

Exploiting geometric degrees of freedom in topological quantum computing

In a topological quantum computer, braids of non-Abelian anyons in a (2+1)-dimensional space time form quantum gates, whose fault tolerance relies on the topological, rather than geometric, properties of the braids. Here we propose to create and exploit redundant geometric degrees of freedom to improve the theoretical accuracy of topological single- and two-qubit quantum gates. We demonstrate the power of the idea using explicit constructions in the Fibonacci model. We compare its efficiency with that of the Solovay-Kitaev algorithm and explain its connection to the leakage errors reduction in an earlier construction [H. Xu and X. Wan, Phys. Rev. A 78, 042325 (2008)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative analysis of image binarization methods for crack identification in concrete structures

Surface cracks in concrete structures are critical indicators of structural damage and durability. Manual visual inspection, the most commonly used method in practice, is inefficient from cost, time, accuracy, and safety perspectives. A promising alternative is computer vision-based methods that can automatically extract crack information from images. Image binarization, developed for text detection, is appropriate for crack identification, as texts and cracks are similar, consisting of distinguishable lines and curves. However, standardizing crack identification using image binarization is challenging, because binarization depends on the method and associated parameters. We investigate image binarization for crack identification, focusing on optimal parameter determination and comparative performance evaluation for five common binarization methods. Crack images are prepared to obtain optimal parameters by minimizing errors in estimated crack widths. Subsequently, comparative analysis is conducted using crack images with different conditions based on three performance evaluation criteria: crack width and length measurement accuracy and computation time.

36 MATERIALS SCIENCE↗

Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms

Purpose: Recently, image-based computational fluid dynamics (CFD) simulation has been applied to investigate the hemodynamics inside human cerebral aneurysms. The knowledge of the computed three-dimensional flow fields is used for clinical risk assessment and treatment decision making. However, the reliability of the application specific CFD results has not been thoroughly validated yet. Methods: In this work, by exploiting a phantom aneurysm model, the authors therefore aim to prove the reliability of the CFD results obtained from simulations with sufficiently accurate input boundary conditions. To confirm the correlation between the CFD results and the reality, virtual angiograms are generated by the simulation pipeline and are quantitatively compared to the experimentally acquired angiograms. In addition, a parametric study has been carried out to systematically investigate the influence of the input parameters associated with the current measuring techniques on the flow patterns. Results: Qualitative and quantitative evaluations demonstrate good agreement between the simulated and the real flow dynamics. Discrepancies of less than 15% are found for the relative root mean square errors of time intensity curve comparisons from each selected characteristic position. The investigated input parameters show different influences on the simulation results, indicating the desired accuracy in the measurements. Conclusions: This study provides a comprehensive validation method of CFD simulation for reproducing the real flow field in the cerebral aneurysm phantom under well controlled conditions. The reliability of the CFD is well confirmed. Through the parametric study, it is possible to assess the degree of validity of the associated CFD model based on the parameter values and their estimated accuracy range.

42 ENGINEERING↗

Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

60 APPLIED LIFE SCIENCES↗

Redundancy management of multiple KT-70 inertial measurement units applicable to the space shuttle

Results of an investigation of velocity failure detection and isolation for 3 inertial measuring units (IMU) and 2 inertial measuring units (IMU) configurations are presented. The failure detection and isolation algorithm performance was highly successful and most types of velocity errors were detected and isolated. The failure detection and isolation algorithm also included attitude FDI but was not evaluated because of the lack of time and low resolution in the gimbal angle synchro outputs. The shuttle KT-70 IMUs will have dual-speed resolvers and high resolution gimbal angle readouts. It was demonstrated by these tests that a single computer utilizing a serial data bus can successfully control a redundant 3-IMU system and perform FDI.

Cook, L. J.↗

Photoacoustic infrared spectroscopy for conducting gas tracer tests and measuring water saturations in landfills

Highlights: Black-Right-Pointing-Pointer Photoacoustic infrared spectroscopy tested for measuring tracer gas in landfills. Black-Right-Pointing-Pointer Measurement errors for tracer gases were 1-3% in landfill gas. Black-Right-Pointing-Pointer Background signals from landfill gas result in elevated limits of detection. Black-Right-Pointing-Pointer Technique is much less expensive and easier to use than GC. - Abstract: Gas tracer tests can be used to determine gas flow patterns within landfills, quantify volatile contaminant residence time, and measure water within refuse. While gas chromatography (GC) has been traditionally used to analyze gas tracers in refuse, photoacoustic spectroscopy (PAS) might allow real-time measurements with reduced personnel costs and greater mobility and ease of use. Laboratory and field experiments were conducted to evaluate the efficacy of PAS for conducting gas tracer tests in landfills. Two tracer gases, difluoromethane (DFM) and sulfur hexafluoride (SF{sub 6}), were measured with a commercial PAS instrument. Relative measurement errors were invariant with tracer concentration but influenced by background gas: errors were 1-3% in landfill gas but 4-5% in air. Two partitioning gas tracer tests were conducted in an aerobic landfill, and limits of detection (LODs) were 3-4 times larger for DFM with PAS versus GC due to temporal changes in background signals. While higher LODs can be compensated by injecting larger tracer mass, changes in background signals increased the uncertainty in measured water saturations by up to 25% over comparable GC methods. PAS has distinct advantages over GC with respect to personnel costs and ease of use, although for field applications GC analyses of select samples are recommended to quantify instrument interferences.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-G-207-06: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Physical Phantom and Clinical Patient Images

Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCA coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential to localize tumor and other patient anatomical structures at treatment time even when inter-fractional changes occur. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc., Palo Alto, CA. The project was also supported, in part, by Award Number R21CA156068 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Chapter 13: Assessing Persistence and Other Evaluation Issues Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Addressing other evaluation issues that have been raised in the context of energy efficiency programs, this chapter focuses on methods used to address the persistence of energy savings, which is an important input to the benefit/cost analysis of energy efficiency programs and portfolios. In addition to discussing 'persistence' (which refers to the stream of benefits over time from an energy efficiency measure or program), this chapter provides a summary treatment of these issues -Synergies across programs -Rebound -Dual baselines -Errors in variables (the measurement and/or accuracy of input variables to the evaluation).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of fluid-fluid interfacial areas measured with X-ray microtomography and interfacial partitioning tracer tests for the same samples

Two different methods are currently used for measuring interfacial areas between immiscible fluids within 3-D porous media, high-resolution microtomographic imaging and interfacial partitioning tracer tests (IPTT). Both methods were used in this study to measure nonwetting/wetting interfacial areas for a natural sand. The microtomographic imaging was conducted on the same packed columns that were used for the IPTTs. This is in contrast to prior studies comparing the two methods, for which in all cases different samples were used for the two methods. In addition, the columns were imaged before and after the IPTTs to evaluate the potential impacts of the tracer solution on fluid configuration and attendant interfacial area. The interfacial areas measured using IPTT are ~5 times larger than the microtomographic-measured values, which is consistent with previous work. Analysis of the image data revealed no significant impact of the tracer solution on NAPL configuration or interfacial area. Furthermore, other potential sources of error were evaluated, and all were demonstrated to be insignificant. The disparity in measured interfacial areas between the two methods is attributed to the limitation of the microtomography method to characterize interfacial area associated with microscopic surface roughness due to resolution constraints.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Synthesis of Architecture of Avionic Systems

The Architecture Synthesis Tool (AST) is software that automatically synthesizes software and hardware architectures of avionic systems. The AST is expected to be most helpful during initial formulation of an avionic-system design, when system requirements change frequently and manual modification of architecture is time-consuming and susceptible to error. The AST comprises two parts: (1) an architecture generator, which utilizes a genetic algorithm to create a multitude of architectures; and (2) a functionality evaluator, which analyzes the architectures for viability, rejecting most of the non-viable ones. The functionality evaluator generates and uses a viability tree a hierarchy representing functions and components that perform the functions such that the system as a whole performs system-level functions representing the requirements for the system as specified by a user. Architectures that survive the functionality evaluator are further evaluated by the selection process of the genetic algorithm. Architectures found to be most promising to satisfy the user s requirements and to perform optimally are selected as parents to the next generation of architectures. The foregoing process is iterated as many times as the user desires. The final output is one or a few viable architectures that satisfy the user s requirements.

Chau, Savio↗

BrachyView, A novel inbody imaging system for HDR prostate brachytherapy: Design and Monte Carlo feasibility study

Purpose: High dose rate (HDR) brachytherapy is a form of radiation therapy for treating prostate cancer whereby a high activity radiation source is moved between predefined positions inside applicators inserted within the treatment volume. Accurate positioning of the source is essential in delivering the desired dose to the target area while avoiding radiation injury to the surrounding tissue. In this paper, HDR BrachyView, a novel inbody dosimetric imaging system for real time monitoring and verification of the radioactive seed position in HDR prostate brachytherapy treatment is introduced. The current prototype consists of a 15 Multiplication-Sign 60 mm{sup 2} silicon pixel detector with a multipinhole tungsten collimator placed 6.5 mm above the detector. Seven identical pinholes allow full imaging coverage of the entire treatment volume. The combined pinhole and pixel sensor arrangement is geometrically designed to be able to resolve the three-dimensional location of the source. The probe may be rotated to keep the whole prostate within the transverse plane. The purpose of this paper is to demonstrate the efficacy of the design through computer simulation, and to estimate the accuracy in resolving the source position (in detector plane and in 3D space) as part of the feasibility study for the BrachyView project.Methods: Monte Carlo simulations were performed using the GEANT4 radiation transport model, with a {sup 192}Ir source placed in different locations within a prostate phantom. A geometrically accurate model of the detector and collimator were constructed. Simulations were conducted with a single pinhole to evaluate the pinhole design and the signal to background ratio obtained. Second, a pair of adjacent pinholes were simulated to evaluate the error in calculated source location.Results: Simulation results show that accurate determination of the true source position is easily obtainable within the typical one second source dwell time. The maximum error in the estimated projection position was found to be 0.95 mm in the imaging (detector) plane, resulting in a maximum source positioning estimation error of 1.48 mm.Conclusions: HDR BrachyView is a feasible design for real-time source tracking in HDR prostate brachytherapy. It is capable of resolving the source position within a subsecond dwell time. In combination with anatomical information obtained from transrectal ultrasound imaging, HDR BrachyView adds a significant quality assurance capability to HDR brachytherapy treatment systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recovering noise-free quantum observables

We introduce a technique for recovering noise-free observables in noisy quantum systems by combining the results of many slightly different experiments. Our approach is applicable to a variety of quantum systems, but we illustrate it with applications to quantum information and quantum sensing. The approach corresponds to repeating the same quantum evolution many times with known variations on the underlying systems' error properties, e.g., the spontaneous emission and dephasing times $T_1$ and $T_2$. As opposed to standard quantum error correction methods, which have an overhead in the number of qubits (many physical qubits must be added for each logical qubit), our method has only an overhead in the number of evaluations, allowing the overhead to, in principle, be hidden via parallelization. We show that the effective spontaneous emission $T_1$ and dephasing $T_2$ times can be increased using this method in both simulation and experiments on an actual quantum computer. We also show how to correct more complicated entangled states and how Ramsey fringes relevant to quantum sensing can be significantly extended in time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bias in Dynamic Monte Carlo Alpha Calculations

A 1/N bias in the estimate of the neutron time-constant (commonly denoted as α) has been seen in dynamic neutronic calculations performed with MCATK. In this paper we show that the bias is most likely caused by taking the logarithm of a stochastic quantity. We also investigate the known bias due to the particle population control method used in MCATK. We conclude that this bias due to the particle population control method is negligible compared to other sources of bias.

42 ENGINEERING↗

Time-evolution methods for matrix-product states

Highlights: • Introductory review of time-evolution methods for matrix-product states. • Detailed description of five state-of-the-art algorithms. • Extended comparison of numerical examples. • Extended error analysis of each algorithm. • Pseudo-code examples towards an implementation where necessary. - Abstract: Matrix-product states have become the de facto standard for the representation of one-dimensional quantum many body states. During the last few years, numerous new methods have been introduced to evaluate the time evolution of a matrix-product state. Here, we will review and summarize the recent work on this topic as applied to finite quantum systems. We will explain and compare the different methods available to construct a time-evolved matrix-product state, namely the time-evolving block decimation, the MPO W{sup I,II} method, the global Krylov method, the local Krylov method and the one- and two-site time-dependent variational principle. We will also apply these methods to four different representative examples of current problem settings in condensed matter physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of a Real-time Processing System for the NASA Multifrequency Microwave Radiometer

A study was conducted to investigate the data reduction and processing requirements for the multifrequency microwave radiometer system (MFMR). The objectives were to develop and evaluate algorithms and processing techniques which might provide for dedicated real time or near real time data processing and to develop a configuration design and processor recommendation to accomplish the data reduction. An analysis of the required data reduction and calibration equations was included along with the identification of sources of error which may be present in the (MFMR) data. The definition and evaluation of the significance of effects introduced by aircraft perturbation was given.

Source record↗

Quantifying Diurnal Cloud Radiative Effects by Cloud Type in the Tropical Western Pacific

Cloud radiative effects are examined using long-term datasets collected at the three Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facilities in the tropical western Pacific. We quantify the surface radiation budget, cloud populations, and cloud radiative effects by partitioning the data by cloud type, time of day, and as a function of large scale modes of variability such as El Niño Southern Oscillation (ENSO) phase and wet/dry seasons at Darwin. The novel facet of our analysis is that we break aggregate cloud radiative effects down by cloud type across the diurnal cycle. The Nauru cloud populations and subsequently the surface radiation budget are strongly impacted by ENSO variability whereas the cloud populations over Manus only shift slightly in response to changes in ENSO phase. The Darwin site exhibits large seasonal monsoon related variations. We show that while deeper convective clouds have a strong conditional influence on the radiation reaching the surface, their limited frequency reduces their aggregate radiative impact. The largest source of shortwave cloud radiative effects at all three sites comes from low clouds. We use the observations to demonstrate that potential model biases in the amplitude of the diurnal cycle and mean cloud frequency would lead to larger errors in the surface energy budget compared to biases in the timing of the diurnal cycle of cloud frequency. Our results provide solid benchmarks to evaluate model simulations of cloud radiative effects in the tropics.

54 ENVIRONMENTAL SCIENCES↗

Fast Evaluation of Aircraft Icing Severity Using Machine Learning Based on XGBoost

Aircraft icing represents a serious hazard in aviation which has caused a number of fatal accidents over the years. In addition, it can lead to substantial increase in drag and weight, thus reducing the aerodynamics performance of the airplane. The process of ice accretion on a solid surface is a complex interaction of aerodynamic and environmental variables. The complex relationship makes machine learning-based methods an attractive alternative to traditional numerical simulation-based approaches. In this study, we introduce a purely data-driven approach to find the complex pattern between different flight conditions and aircraft icing severity prediction. The supervised learning algorithm Extreme Gradient Boosting (XGBoost) is applied to establish the prediction framework which makes prediction based on any set of observations. The input flight conditions for the proposed prediction framework are liquid water content, droplet diameter and exposure time. The proposed approach is demonstrated in three cases: maximum ice thickness prediction, icing area prediction and icing severity level evaluation. Performance comparison studies and error analysis are also conducted to verify the effectiveness and performance of the proposed method. Results show that the proposed method has reasonable capability in evaluating aircraft icing severity.

Li, Sibo (ORCID:000000021705844X)↗