Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Computational and Experimental Design of Fe-Based Superalloys for Elevated-Temperature Applications

Analogous to nickel-based superalloys, Fe-based superalloys, which are strengthened by coherent B2- type precipitates are proposed for elevated-temperature applications. During the period of this project, a series of ferritic superalloys have been designed and fabricated by methods of vacuum-arc melting and vacuum-induction melting. Nano-scale precipitates were characterized by atom-probe tomography, ultrasmall- angle X-ray scattering, and transmission-electron microscopy. A duplex distribution of precipitates was found. It seems that ferritic superalloys are susceptible to brittle fracture. Systematic endeavors have been devoted to understanding and resolving the problem. Factors, such as hot rolling, precipitate volume fractions, alloy compositions, precipitate sizes and inter-particle spacings, and hyperfine cooling precipitates, have been investigated. In order to understand the underlying relationship between the microstructure and creep behavior of ferric alloys at elevated temperatures, in-situ neutron studies have been carried out. Based on the current result, it seems that the major role of β' with a 16%-volume fraction in strengthening ferritic alloys is not load sharing but interactions with dislocations. The oxidation behavior of one ferritic alloy, FBB8 (Fe-6.5Al-10Ni-10Cr-3.4Mo-0.25Zr-0.005B, weight percent), was studied in dry air. It is found that it possesses superior oxidation resistance at 1,023 and 1,123 K, compared with other creep-resistant ferritic steels [T91 (modified 9Cr-1Mo, weight percent) and P92 (9Cr-1.8W-0.5Mo, weight percent)]. At the same time, the calculation of the interfacial energies between the -iron and B2-type intermetallics (CoAl, FeAl, and NiAl) has been conducted.

36 MATERIALS SCIENCE↗

On proton CT reconstruction using MVCT-converted virtual proton projections

Purpose: To describe a novel methodology of converting megavoltage x-ray projections into virtual proton projections that are otherwise missing due to the proton range limit. These converted virtual proton projections can be used in the reconstruction of proton computed tomography (pCT). Methods: Relations exist between proton projections and multispectral megavoltage x-ray projections for human tissue. Based on these relations, these tissues can be categorized into: (a) adipose tissue; (b) nonadipose soft tissues; and (c) bone. These three tissue categories can be visibly identified on a regular megavoltage x-ray computed tomography (MVCT) image. With an MVCT image and its projection data available, the x-ray projections through heterogeneous anatomy can be converted to the corresponding proton projections using predetermined calibration curves for individual materials, aided by a coarse segmentation on the x-ray CT image. To show the feasibility of this approach, mathematical simulations were carried out. The converted proton projections, plotted on a proton sinogram, were compared to the simulated ground truth. Proton stopping power images were reconstructed using either the virtual proton projections only or a blend of physically available proton projections and virtual proton projections that make up for those missing due to the range limit. These images were compared to a reference image reconstructed from theoretically calculated proton projections. Results: The converted virtual projections had an uncertainty of {+-}0.8% compared to the calculated ground truth. Proton stopping power images reconstructed using a blend of converted virtual projections (48%) and physically available projections (52%) had an uncertainty of {+-}0.86% compared with that reconstructed from theoretically calculated projections. Reconstruction solely from converted virtual proton projections had an uncertainty of {+-}1.1% compared with that reconstructed from theoretical projections. If these images are used for treatment planning, the average proton range uncertainty is estimated to be less than 1.5% for an imaging dose in the milligray range. Conclusions: The proposed method can be used to convert x-ray projections into virtual proton projections. The converted proton projections can be blended with existing proton projections or can be used solely for pCT reconstruction, addressing the range limit problem of pCT using current therapeutic proton machines.

60 APPLIED LIFE SCIENCES↗

Fluid pressure arrival time tomography: Estimation and assessment in the presence of inequality constraints, with an application to a producing gas field at Krechba, Algeria

Deformation in the overburden proves useful in deducing spatial and temporal changes in the volume of a producing reservoir. Based upon these changes we estimate diffusive travel times associated with the transient flow due to production, and then, as the solution of a linear inverse problem, the effective permeability of the reservoir. An advantage an approach based upon travel times, as opposed to one based upon the amplitude of surface deformation, is that it is much less sensitive to the exact geomechanical properties of the reservoir and overburden. Inequalities constrain the inversion, under the assumption that the fluid production only results in pore volume decreases within the reservoir. We apply the formulation to satellite-based estimates of deformation in the material overlying a thin gas production zone at the Krechba field in Algeria. The peak displacement after three years of gas production is approximately 0.5 cm, overlying the eastern margin of the anticlinal structure defining the gas field. Using data from 15 irregularly-spaced images of range change, we calculate the diffusive travel times associated with the startup of a gas production well. The inequality constraints are incorporated into the estimates of model parameter resolution and covariance, improving the resolution by roughly 30 to 40%.

54 ENVIRONMENTAL SCIENCES↗

Digital Radiography and Computed Tomography (DRCT) of Recovered Chemical Warfare Materiel

The Digital Radiography and Computed Tomography (DRCT) of recovered chemical warfare material (RCWM) project is an ongoing effort to provide the following to the U.S. Army Chemical Materiel Activity (CMA): 1. Development of field-portable and transportable digital x-ray inspection capabilities including radiography and computed tomography. 2. Continuous maintenance and product development to maintain state of the art in x-ray inspection. 3. Evaluation and incorporation of advanced technologies. 4. Deployment of capabilities to selected U.S. Army designated sites. 5. Training of personnel in the use of x-ray inspection equipment. 6. Development of user guides and related documentation for inspection systems. 7. Operations support to field personnel to assess and resolve problems in the field. Support includes both remote (from Idaho) and on-site depending on the problem. These systems have been used to inspect thousands of containers ranging from bare and overpacked munitions to drums and ton containers. This in-progress program review showcases prospective efforts and updates to project systems that are in the developmental stage.

36 MATERIALS SCIENCE↗

Titanium porous-transport layers for PEM water electrolysis prepared by tape casting

While the porous-transport layer (PTL) is a key component in PEM electrolyzers, it is one of the most underexplored due to limited available structures. In this work, we present a novel PTL design for PEM water electrolyzers enabled by a cost-effective, scalable tape-casting technique. Here, a precise control of the PTL pore structure is achieved by incorporating poreformers of various sizes, and by varying the titanium and poreformer ratio. The structures are characterized with SEM and synchrotron X-ray computed tomography imaging techniques. Comprehensive electrochemical performance analysis demonstrates that higher titanium loading provides improved contact at the catalyst-layer/PTL interface but suffers from severe mass-transport losses due to gas bubbles. We solve this mass-transport problem by mixing in large poreformer beads that produce a highly porous structure with excellent gas removal properties yet still maintaining mechanical integrity. The PTL fabricated with 60:40 Ti:PMMA ratio and 60 μm PMMA bead size outperformed the standard commercial Ti powder-based PTL by 62 mV at 4 A/cm 2 .

25 ENERGY STORAGE↗

Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation

Purpose: Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol.Methods: A previously designed flow phantom, capable of producing predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared.Results: The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2 ± 1.1% (total calculated output contrast mass error) with a goodness of fit (R{sup 2}) of greater than 0.99 ± 0.0035 (n= 10). The DCE-CT QA protocol was capable of detecting significant deviations from the expected phantom result when scanning at low mAs and low kVp in terms of quantitative metrics (Injected Mass Error 15.4%), goodness of fit (R{sup 2}) of 0.91, and ROI sensitivity (increase in minimum input function ROI radius by 146 ± 86%). These tests also confirmed that the ASIR reconstruction process was beneficial in reducing noise without substantially increasing partial volume effects and that vendor specific modes (e.g., axial shuttle) did not significantly affect the phantom results. The phantom and QA protocol were finally able to quickly (<90 min) and successfully validate the DCE-CT imaging protocol utilized at the three separate institutions of a multicenter clinical trial; thereby enhancing the confidence in the patient data collected.Conclusions: A DCE QA protocol was developed that, in combination with a dynamic multimodality flow phantom, allows the intrascanner variability to be separated from other sources of variability such as the impact of injection protocol and ROI selection. This provides a valuable resource that can be utilized at various clinical trial institutions to test conformance with imaging protocols and accuracy requirements as well as ensure that the scanners are performing as expected for dynamic scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of columnar CsI x-ray detector responses obtained with hybridMANTIS, a CPU-GPU Monte Carlo code for coupled x-ray, electron, and optical transport

Purpose: hybridMANTIS is a Monte Carlo package for modeling indirect x-ray imagers using columnar geometry based on a hybrid concept that maximizes the utilization of available CPU and graphics processing unit processors in a workstation. Methods: The authors compare hybridMANTIS x-ray response simulations to previously published MANTIS and experimental data for four cesium iodide scintillator screens. These screens have a variety of reflective and absorptive surfaces with different thicknesses. The authors analyze hybridMANTIS results in terms of modulation transfer function and calculate the root mean square difference and Swank factors from simulated and experimental results. Results: The comparison suggests that hybridMANTIS better matches the experimental data as compared to MANTIS, especially at high spatial frequencies and for the thicker screens. hybridMANTIS simulations are much faster than MANTIS with speed-ups up to 5260. Conclusions: hybridMANTIS is a useful tool for improved description and optimization of image acquisition stages in medical imaging systems and for modeling the forward problem in iterative reconstruction algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards resolving protein structures at the atomic scale using atom probe tomography

In the field of Structural Biology, Atom Probe Tomography (APT) is in the nascent stages of development wherein coarse-grained visuals of proteins have been captured. The characterization of organic samples or biomolecules through the technique is currently limited to the detection of a few dominant signatures. The problem of indecipherable characterization can inherently be traced back to multiple forms of technique-specific responses to organic samples and consequent triggers leading to organic-sample and sample-medium interactions. While it is possible for captured manifestations of protein reconstructions to seemingly appear intact from a basic visual purview, the parameter-protein associative responses throughout the structure as a direct consequence of the inherent workings of the technique (until harmonized with organic sample complexity and behavior) and field evaporation-based factors make non-aberrative atomic associations infeasible. The work focused on identifying and theorizing the (above stated and other) fundamental mechanisms that stronghold the study of intricate atomic to higher order associations in proteins through APT. Attempts at structure elucidation of the cryogenic sample under study, through indirect associations (and methods) based on other imaging techniques, further revealed the distinct and highly distortive nature at the atomic scale deterring structural tunability and thus characterization of APT based cryogenic samples under analysis. As a direct counter to the atomic scale characterization problem, by taking the experiment-specific uncertainties, and probable APT-centric organic sample-based variabilities into account, a basic result is extracted and presented. Through mass-spectrometric and computational analysis, specific individual amino acids (Sulfur-containing protein-bound amino acids) in proteins and aspects of protein structure (probable backbone fragments, partial sequence - partial backbone portions) have been identified and characterized. Under analysis considerations, a few of the simplest known and easily inferable segments that favor structural deteriorations in the reconstructions are stated. Additionally, to overcome technique-specific deterrents to the characterization of biomolecules in cryogenic sample medium, the development of a protein-labeling strategy tailored to APT is suggested.

59 BASIC BIOLOGICAL SCIENCES↗

Automated defect detection in spent nuclear fuel using combine Cerenkov and Gamma Emission Tomography data

Spent fuel monitoring and characterization has been a pillar of safeguards and nuclear facility monitoring for many years. The Digital Cerenkov Viewing Device (DCVD) has been used since the 1980s as a method of defect detection in spent fuel. In recent years, the accounting of large quantities of spent fuel before storage has renewed interest in this relatively quick and inexpensive method. This has an impact not only in safeguards, but also in for nuclear power facilities, as accounting can be a long and arduous process. Additionally, the DCVD demonstrates limited accuracy in more complex cases such as substitution of a fuel rod with steel, or a partial defect detection. A second method, Gamma Emission Tomography (GET) has been explored as an improved defect detection method, but is much more expensive and invasive than DCVD. This work identifies deficiencies in both methods, and proposes a combination of data gathered from each method to address these deficiencies for improved spent fuel characterization. Initial results are promising, showing 97% detection of a single missing fuel rod when the data types are combined, versus approximately 50% and 70%respectively for DCVD and GET data on their own. Finally, these classification results are obtained with algorithms derived from facial recognition and applied to this problem, yielding unique accuracy in near real-time while also maintaining the information barrier between output and measurement desired in safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Three-Dimensional Reconstruction and Analysis of All-Solid Li-Ion Battery Electrode Using Synchrotron Transmission X-ray Microscopy Tomography

A synchrotron transmission X-ray microscopy tomography system with a spatial resolution of 58.2 nm at the Advanced Photon Source was employed to obtain three-dimensional morphological data of all-solid Li-ion battery electrodes. The three-phase electrode was fabricated from a 47:47:6 (wt %) mixture of Li(Ni 1/3 Mn 1/3 Co 1/3 )O 2 as active material, Li 1.3 Ti 1.7 Al 0.3 (PO 4 ) 3 as Li-ion conductor, and Super-P carbon as electron conductor. Furthermore, the geometric analysis show that particle-based all-solid Li-ion battery has serious contact interface problem which significantly impact the Li-ion transport and intercalation reaction in the electrode, leading to low capacity, poor rate capability and cycle life.

25 ENERGY STORAGE↗

Physical cryptographic verification of nuclear warheads

Significance We provide a method for potentially solving one of the central problems in arms control: proving the authenticity of a nuclear warhead without revealing information about its construction. The proposal is the first, to our knowledge, to be proof-theoretically sound (i.e., unspoofable) and information-theoretically secure. The method uses a tomography technique which can resolve the spatial distribution of mass with isotopic specificity. The soundness and security emerge from an integral-geometric transform that is able to uniquely map 3D geometries from zero-dimensional point measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DOLCE: A Model-Based Probabilistic Diffusion Framework for Limited-Angle CT Reconstruction

Limited-Angle Computed Tomography (LACT) is a non-destructive evaluation technique used in a variety of applications ranging from security to medicine. The limited angle coverage in LACT is often a dominant source of severe artifacts in the reconstructed images, making it a challenging inverse problem. We present DOLCE, a new deep model-based framework for LACT that uses a conditional diffusion model as an image prior. Diffusion models are a recent class of deep generative models that are relatively easy to train due to their implementation as image denoisers. DOLCE can form high-quality images from severely under-sampled data by integrating data-consistency updates with the sampling updates of a diffusion model, which is conditioned on the transformed limited-angle data. We show through extensive experimentation on several challenging real LACT datasets that, the same pre-trained DOLCE model achieves the SOTA performance on drastically different types of images. Additionally, we show that, unlike standard LACT reconstruction methods, DOLCE naturally enables the quantification of the reconstruction uncertainty by generating multiple samples consistent with the measured data.

Kim, Hyojin↗

A Bayesian Measurment Error Model for Misaligned Radiographic Data

An understanding of the inherent variability in micro-computed tomography (micro-CT) data is essential to tasks such as statistical process control and the validation of radiographic simulation tools. The data present unique challenges to variability analysis due to the relatively low resolution of radiographs, and also due to minor variations from run to run which can result in misalignment or magnification changes between repeated measurements of a sample. Positioning changes artificially inflate the variability of the data in ways that mask true physical phenomena. We present a novel Bayesian nonparametric regression model that incorporates both additive and multiplicative measurement error in addition to heteroscedasticity to address this problem. We also use this model to assess the effects of sample thickness and sample position on measurement variability for an aluminum specimen. Supplementary materials for this article are available online.

97 MATHEMATICS AND COMPUTING↗

Imaging properties and its improvements of scanning/imaging x-ray microscope

A scanning / imaging X-ray microscope (SIXM) system has been developed at SPring-8. The SIXM consists of a scanning X-ray microscope with a one-dimensional (1D) X-ray focusing device and an imaging (full-field) X-ray microscope with a 1D X-ray objective. The motivation of the SIXM system is to realize a quantitative and highly-sensitive multimodal 3D X-ray tomography by taking advantages of both the scanning X-ray microscope using multi-pixel detector and the imaging X-ray microscope. Data acquisition process of a 2D image is completely different between in the horizontal direction and in the vertical direction; a 1D signal is obtained with the linear-scanning while the other dimensional signal is obtained with the imaging optics. Such condition have caused a serious problem on the imaging properties that the imaging quality in the vertical direction has been much worse than that in the horizontal direction. In this paper, two approaches to solve this problem will be presented. One is introducing a Fourier transform method for phase retrieval from one phase derivative image, and the other to develop and employ a 1D diffuser to produce an asymmetrical coherent illumination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iatrogenic Subtotal Stenosis of the Right Subclavian Artery Treated With Percutaneous Transluminal Angioplasty

This report describes a rare vascular complication of surgical placement of a marking clip and a possible approach to problem solving. A 55-year-old patient presented with loss of sensation in the fingers and loss of peripheral pulsations in the right arm 4 days after right upper lobectomy for a pT2N1 moderately differentiated adenocarcinoma of the lung. Duplex examination and computed tomography were performed the same day and showed a subtotal stenosis of the right subclavian artery, which was caused by the surgical placement of a metal clip to mark the surgical boundary. Selective angiography was subsequently performed. Percutaneous transluminal angioplasty (PTA) successfully dilated the stenosis and pushed the clip off. Flow in the right subclavian artery (RSA) was completely restored as were neurology and peripheral pulses. In conclusion, arterial stenosis by a surgical (marking) clip may be feasibly treated with PTA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ru supported on micro and mesoporous carbons as catalysts for biomass-derived molecules hydrogenation

Supported ruthenium based materials are active for the catalytic hydrogenation of biomass-derived molecules. However, such catalysts still have problems regarding deactivation coming from Ru leaching and particles aggregation. In this work we demonstrate that spatial restriction on metal nanoparticles limits aggregation and eliminates performance losses upon subsequent testing. We synthesized and compared Ru supported on activated (Ru/AC) or mesoporous carbon (Ru/MC). Electron tomography characterization showed preferential Ru location depending on the material porosity; Ru nanoparticles were located inside mesoporous carbon pores and showed narrower size distribution. In catalytic reactions, Ru/MC reached the complete conversion of levulinic acid with the 96% selectivity to γ-valerolactone while it converted 74% of glycerol compared to the 34% showed by Ru/AC. Furthermore, we find that the Ru/AC materials deactivated after 1 catalytic cycle, however the Ru/MC maintained constant activity for multiple catalytic cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2D and 3D characterization of pore defects in die cast AM60

The widespread application of die castings can be hampered due to the potential of large scale porosity to act as nucleation sites for fracture and fatigue. It is therefore important to develop robust approaches to the characterization of porosity providing parameters that can be linked to the material's mechanical properties. We have tackled this problem in a study of the AM60 die cast Mg alloy, using samples extracted from a prototype shock tower. A quantitative characterization of porosity has been undertaken, analyzing porosity in both 2D (using classical metallographic methods) and in 3D (using X-ray computed tomography (XCT)). Metallographic characterization results show that shrinkage pores and small gas pores can be distinguished based on their distinct geometrical features. Shrinkage pores are irregular with multiple arms, resulting in a form factor less than 0.4. In contrast, gas pores are generally more circular in shape yielding form factors larger than 0.6. XCT provides deeper insight into the shape of pores, although this understanding is limited by the resolution obtainable by laboratory based XCT. It also shows how 2D sectioning can produce artefacts as single complex pores are sectioned into multiple small pores. - Highlights: • Mg (e.g. AM60) die castings may contain large scale porosity that act as nucleation sites for fracture and fatigue • Quantitative characterization of porosity metallography (2D) and X-ray tomography (3D) is used • Shrinkage pores and small gas pores can be distinguished based on their distinct geometrical features. • Shrinkage pores are irregular giving a form factor < 0.4; gas pores are rounder with form factors > 0.6 • XCT enables pore visualization, although limited by the resolution obtainable by laboratory based XCT.

36 MATERIALS SCIENCE↗

Bayesian soft X-ray tomography using non-stationary Gaussian Processes

In this study, a Bayesian based non-stationary Gaussian Process (GP) method for the inference of soft X-ray emissivity distribution along with its associated uncertainties has been developed. For the investigation of equilibrium condition and fast magnetohydrodynamic behaviors in nuclear fusion plasmas, it is of importance to infer, especially in the plasma center, spatially resolved soft X-ray profiles from a limited number of noisy line integral measurements. For this ill-posed inversion problem, Bayesian probability theory can provide a posterior probability distribution over all possible solutions under given model assumptions. Specifically, the use of a non-stationary GP to model the emission allows the model to adapt to the varying length scales of the underlying diffusion process. In contrast to other conventional methods, the prior regularization is realized in a probability form which enhances the capability of uncertainty analysis, in consequence, scientists who concern the reliability of their results will benefit from it. Under the assumption of normally distributed noise, the posterior distribution evaluated at a discrete number of points becomes a multivariate normal distribution whose mean and covariance are analytically available, making inversions and calculation of uncertainty fast. Additionally, the hyper-parameters embedded in the model assumption can be optimized through a Bayesian Occam's Razor formalism and thereby automatically adjust the model complexity. This method is shown to produce convincing reconstructions and good agreements with independently calculated results from the Maximum Entropy and Equilibrium-Based Iterative Tomography Algorithm methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗