Search NASA⌕ Search

SEARCH · Search NASA

Results for “toxicity values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Treatment Guidelines for Preoperative Radiation Therapy for Retroperitoneal Sarcoma: Preliminary Consensus of an International Expert Panel

Purpose: Evidence for external beam radiation therapy (RT) as part of treatment for retroperitoneal sarcoma (RPS) is limited. Preoperative RT is the subject of a current randomized trial, but the results will not be available for many years. In the meantime, many practitioners use preoperative RT for RPS, and although this approach is used in practice, there are no radiation treatment guidelines. An international expert panel was convened to develop consensus treatment guidelines for preoperative RT for RPS. Methods and Materials: An expert panel of 15 academic radiation oncologists who specialize in the treatment of sarcoma was assembled. A systematic review of reports related to RT for RPS, RT for extremity sarcoma, and RT-related toxicities for organs at risk was performed. Due to the paucity of high-quality published data on the subject of RT for RPS, consensus recommendations were based largely on expert opinion derived from clinical experience and extrapolation of relevant published reports. It is intended that these clinical practice guidelines be updated as pertinent data become available. Results: Treatment guidelines for preoperative RT for RPS are presented. Conclusions: An international panel of radiation oncologists who specialize in sarcoma reached consensus guidelines for preoperative RT for RPS. Many of the recommendations are based on expert opinion because of the absence of higher level evidence and, thus, are best regarded as preliminary. We emphasize that the role of preoperative RT for RPS has not been proven, and we await data from the European Organization for Research and Treatment of Cancer (EORTC) study of preoperative radiotherapy plus surgery versus surgery alone for patients with RPS. Further data are also anticipated pertaining to normal tissue dose constraints, particularly for bowel tolerance. Nonetheless, as we await these data, the guidelines herein can be used to establish treatment uniformity to aid future assessments of efficacy and toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inferring pesticide toxicity to honey bees from a field‐based feeding study using a colony model and Bayesian inference

Abstract Honey bees are crucial pollinators for agricultural crops but are threatened by a multitude of stressors including exposure to pesticides. Linking our understanding of how pesticides affect individual bees to colony‐level responses is challenging because colonies show emergent properties based on complex internal processes and interactions among individual bees. Agent‐based models that simulate honey bee colony dynamics may be a tool for scaling between individual and colony effects of a pesticide. The U.S. Environmental Protection Agency (USEPA) and U.S. Department of Agriculture (USDA) are developing the VarroaPop + Pesticide model, which simulates the dynamics of honey bee colonies and how they respond to multiple stressors, including weather, Varroa mites, and pesticides. To evaluate this model, we used Approximate Bayesian Computation to fit field data from an empirical study where honey bee colonies were fed the insecticide clothianidin. This allowed us to reproduce colony feeding study data by simulating colony demography and mortality from ingestion of contaminated food. We found that VarroaPop + Pesticide was able to fit general trends in colony population size and structure and reproduce colony declines from increasing clothianidin exposure. The model underestimated adverse effects at low exposure (36 µg/kg), however, and overestimated recovery at the highest exposure level (140 µg/kg), for the adult and pupa endpoints, suggesting that mechanisms besides oral toxicity‐induced mortality may have played a role in colony declines. The VarroaPop + Pesticide model estimates an adult oral LD 50 of 18.9 ng/bee (95% CI 10.1–32.6) based on the simulated feeding study data, which falls just above the 95% confidence intervals of values observed in laboratory toxicology studies on individual bees. Overall, our results demonstrate a novel method for analyzing colony‐level data on pesticide effects on bees and making inferences on pesticide toxicity to individual bees.

59 BASIC BIOLOGICAL SCIENCES↗

Biogenic synthesized nanoparticles and their applications

In the present scenario, there are growing concerns over the potential impacts of bioengineered nanoparticles in the health sector. However, our understanding of how bioengineered nanoparticles may affect organisms within natural ecosystems, lags far behind our rapidly increasing ability to engineer novel nanoparticles. To date, research on the biological impacts of bioengineered nanoparticles has primarily consisted of controlled lab studies of model organisms with single species in culture media. Here, we described a cost effective and environment friendly technique for green synthesis of silver nanoparticles. Silver nanoparticles were successfully synthesized from 1 mM AgNO{sub 3} via a green synthesis process using leaf extract as reducing as well as capping agent. Nanoparticles were characterized with the help of UV–vis absorption spectroscopy, X-ray diffraction and TEM analysis which revealed the size of nanoparticles of 30-40 nm size. Further the nanoparticles synthesized by green route are found highly toxic against pathogenic bacteria and plant pathogenic fungi viz. Escherichia coli, Pseudomonas syringae and Sclerotiniasclerotiorum. The most important outcome of this work will be the development of value-added products and protection of human health from pathogens viz., bacteria, virus, fungi etc.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Health-risk based approach to setting drinking water standards for long-term space missions

In order to develop plausible and appropriate drinking water contaminant standards for longer-term NASA space missions, such as those planned for the Space Exploration Initiative, a human health risk characterization was performed using toxicological and exposure values typical of space operations and crew. This risk characterization showed that the greatest acute waterborne health concern was from microbial infection leading to incapacitating gastrointestinal illness. Ingestion exposure pathways for toxic materials yielded de minimus acute health risks unlikely to affect SEI space missions. Risks of chronic health problems were within acceptable public health limits. Our analysis indicates that current Space Station Freedom maximum contamination levels may be unnecessarily strict. We propose alternative environmental contaminant values consistent with both acceptable short and long-term crew health safety.

Macler, Bruce A.↗

Clinical Outcomes of Patients Receiving Integrated PET/CT-Guided Radiotherapy for Head and Neck Carcinoma

Purpose: We previously reported the advantages of {sup 18}F-fluorodeoxyglucose-positron emission tomography (PET) fused with CT for radiotherapy planning over CT alone in head and neck carcinoma (HNC). The purpose of this study was to evaluate clinical outcomes and the predictive value of PET for patients receiving PET/CT-guided definitive radiotherapy with or without chemotherapy. Methods and Materials: From December 2002 to August 2006, 42 patients received PET/CT imaging as part of staging and radiotherapy planning. Clinical outcomes including locoregional recurrence, distant metastasis, death, and treatment-related toxicities were collected retrospectively and analyzed for disease-free and overall survival and cumulative incidence of recurrence. Results: Median follow-up from initiation of treatment was 32 months. Overall survival and disease-free survival were 82.8% and 71.0%, respectively, at 2 years, and 74.1% and 66.9% at 3 years. Of the 42 patients, seven recurrences were identified (three LR, one DM, three both LR and DM). Mean time to recurrence was 9.4 months. Cumulative risk of recurrence was 18.7%. The maximum standard uptake volume (SUV) of primary tumor, adenopathy, or both on PET did not correlate with recurrence, with mean values of 12.0 for treatment failures vs. 11.7 for all patients. Toxicities identified in those patients receiving intensity modulated radiation therapy were also evaluated. Conclusions: A high level of disease control combined with favorable toxicity profiles was achieved in a cohort of HNC patients receiving PET/CT fusion guided radiotherapy plus/minus chemotherapy. Maximum SUV of primary tumor and/or adenopathy was not predictive of risk of disease recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Toxicity Associated With Stereotactic Body Radiation Therapy to the Central Hepatobiliary Tract

Purpose: To identify dosimetric predictors of hepatobiliary (HB) toxicity associated with stereotactic body radiation therapy (SBRT) for liver tumors. Methods and Materials: We retrospectively reviewed 96 patients treated with SBRT for primary (53%) or metastatic (47%) liver tumors between March 2006 and November 2013. The central HB tract (cHBT) was defined by a 15-mm expansion of the portal vein from the splenic confluence to the first bifurcation of left and right portal veins. Patients were censored for toxicity upon local progression or additional liver-directed therapy. HB toxicities were graded according to Common Terminology Criteria for Adverse Events version 4.0. To compare different SBRT fractionations, doses were converted to biologically effective doses (BED) by using the standard linear quadratic model α/β = 10 (BED10). Results: Median follow-up was 12.7 months after SBRT. Median BED10 was 85.5 Gy (range: 37.5-151.2). The median number of fractions was 5 (range: 1-5), with 51 patients (53.1%) receiving 5 fractions and 29 patients (30.2%) receiving 3 fractions. In total, there were 23 (24.0%) grade 2+ and 18 (18.8%) grade 3+ HB toxicities. Nondosimetric factors predictive of grade 3+ HB toxicity included cholangiocarcinoma (CCA) histology (P<.0001), primary liver tumor (P=.0087), and biliary stent (P<.0001). Dosimetric parameters most predictive of grade 3+ HB toxicity were volume receiving above BED10 of 72 Gy (V{sub BED10}72) ≥ 21 cm{sup 3} (relative risk [RR]: 11.6, P<.0001), V{sub BED10}66 ≥ 24 cm{sup 3} (RR: 10.5, P<.0001), and mean BED10 (Dmean{sub BED10}) cHBT ≥14 Gy (RR: 9.2, P<.0001), with V{sub BED10}72 and V{sub BED10}66 corresponding to V40 and V37.7 for 5 fractions and V33.8 and V32.0 for 3 fractions, respectively. V{sub BED10}72 ≥ 21 cm{sup 3}, V{sub BED10}66 ≥ 24 cm{sup 3}, and Dmean{sub BED10} cHBT ≥14 Gy were consistently predictive of grade 3+ toxicity on multivariate analysis. Conclusions: V{sub BED10}72, V{sub BED10}66, and Dmean{sub BED10} to cHBT are associated with HB toxicity. We suggest V{sub BED10}72 < 21 cm{sup 3} (5-fraction: V40 < 21 cm{sup 3}; 3-fraction: V33.8 < 21 cm{sup 3}), V{sub BED10}66 < 24 cm{sup 3} (5-fraction: V37.7 < 24 cm{sup 3}; 3-fraction: V32 < 24 cm{sup 3}) as potential dose constraints for the cHBT when clinically indicated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relevance of Biologically Equivalent Dose Values in Outcome Evaluation of Stereotactic Radiotherapy for Lung Nodules

Purpose: Different biologically equivalent dose (BED) values associated with stereotactic radiotherapy (SRT) of patients with primary and metastatic pulmonary nodules were studied. The BED values were calculated for tumoral tissue and low {alpha}/{beta} ratio, assuming that better local response could be obtained by using stereotactic high-BED treatment. Methods and Materials: Fifty-eight patients with T1-T3 N0 non-small-cell lung cancer and 46 patients with metastatic lung nodules were treated with SRT. The BED was calculated for {alpha}/{beta} ratios of 3 and 10. Overall survival (OS) was assessed according to Kaplan-Meier and appraised as a function of three BED levels: low (30-50 Gy), medium (50-70 Gy), and high (70-98 Gy; {alpha}/{beta} = 10). Results: The OS rates for all 104 patients at 12, 24, and 36 months were 73%, 48.3%, and 35.8%, respectively. Local response greater than 50% for low, medium, and high BED values was observed in 54%, 47%, and 73%, respectively. In the high-BED treated group, OS rates at 12, 24, and 36 months (80.9%, 70%, and 53.6%, respectively) were significantly improved compared with low- (69%, 46.1%, and 30.7%, respectively) and medium-BED (67%, 28%, and 21%, respectively) treated patients. Results are also discussed in terms of BED calculated on {alpha}/{beta} 3 Gy characteristic of the microcapillary bed. No acute toxicity higher than Grade 1 was observed. Conclusions: Radioablation of pulmonary neoplastic nodules may be achieved with SRT delivered by using a high-dose fraction with high BED value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Analysis of Dose–Volume Profiles and its Implication for Radiation Therapy Planning in Prostate Carcinoma

Purpose: The study aimed to analyze the dose–volume profiles of 3-dimensional radiation therapy (3D-CRT) and intensity modulated RT (IMRT) in the treatment of prostate carcinoma and to specify the profiles responsible for the development of gastrointestinal (GI) toxicity. Methods and Materials: In the period 1997 to 2007, 483 patients with prostate carcinoma in stage T1-3 N0 (pN0) M0 were treated with definitive RT. Two groups of patients were defined for the analysis: the 3D-CRT group (n=305 patients) and the IMRT group (n=178 patients). In the entire cohort of 483 patients, the median follow-up time reached 4.4 years (range, 2.0-11.7 years). The cumulative absolute and relative volumes of irradiated rectum exposed to a given dose (area under the dose–volume curve, AUC) were estimated. The receiver operating characteristic analysis was then used to search for the optimal dose and volume cutoff points with the potential to distinguish patients with enhanced or escalated toxicity. Results: Despite the application of high doses (78-82 Gy) in the IMRT group, GI toxicity was lower in that group than in the group treated by 3D-CRT with prescribed doses of 70 to 74 Gy. Both RT methods showed specific rectal dose–volume distribution curves. The total AUC values for IMRT were significantly lower than those for 3D-CRT. Furthermore, IMRT significantly decreased the rectal volume receiving low to intermediate radiation doses in comparison with 3D-CRT; specific cutoff limits predictable for the level of GI toxicity are presented and defined in our work. Conclusions: Total area under the dose–volume profiles and specific cutoff points in low and intermediate dose levels have significant predictive potential toward the RT GI toxicity. In treatment planning, it seems that it is valuable to take into consideration the entire dose–volume primary distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing interspecies uncertainty using data from studies of anti-neoplastic agents in animals and humans

For most chemicals, the Reference Dose (RfD) is based on data from animal testing. The uncertainty introduced by the use of animal models has been termed interspecies uncertainty. The magnitude of the differences between the toxicity of a chemical in humans and test animals and its uncertainty can be investigated by evaluating the inter-chemical variation in the ratios of the doses associated with similar toxicological endpoints in test animals and humans. This study performs such an evaluation on a data set of 64 anti-neoplastic drugs. The data set provides matched responses in humans and four species of test animals: mice, rats, monkeys, and dogs. While the data have a number of limitations, the data show that when the drugs are evaluated on a body weight basis: 1) toxicity generally increases with a species' body weight; however, humans are not always more sensitive than test animals; 2) the animal to human dose ratios were less than 10 for most, but not all, drugs; 3) the current practice of using data from multiple species when setting RfDs lowers the probability of having a large value for the ratio. These findings provide insight into inter-chemical variation in animal to human extrapolations and suggest the need for additional collection and analysis of matched toxicity data in humans and test animals.

60 APPLIED LIFE SCIENCES↗

Near-infrared-emitting heteroleptic cationic iridium complexes derived from 2,3-diphenylbenzo[g]quinoxaline as in vitro theranostic photodynamic therapy agents

Five heteroleptic cationic iridium complexes with a π-expansive cyclometalating 2,3-diphenylbenzo[g] quinoxaline (dpbq) ligand (C^N ligand) and different diimine ligands (N^N ligands) (i.e. 2,2’-bipyridine (bpy, 1), phenanthroline (phen, 2), 2-(2-pyridinyl)quinoline (pqu, 3), 2,2’-bisquinoline (bqu, 4), and 2-(quinolin-2-yl)quinoxaline (quqo, 5)) were synthesized and characterized. The lowest-energy singlet electronic transitions (S1 states) were mainly dpbq ligand-centred 1ILCT (intraligand charge transfer)/1MLCT (metal to ligand charge transfer) transitions mixed with some 1π,π* transitions for complexes 1–4 with increased contributions from 1LLCT (ligand to ligand charge transfer) in 3 and 4. For complex 5, the S1 state was switched to the 1LLCT/1MLCT transitions. All five complexes displayed weak near-infrared (NIR) phosphorescence, with maximal emission output spanning 700–1400 nm and quantum yields being on the order of 10-3. The triplet state absorptions of 1–4 all resembled that of the [Ir(dpbq)2Cl]2 dimer with lifetimes of ca. 400 ns, while the TA spectrum of 5 possessed the characteristics of both the quqo ligand and the [Ir(dpbq)2Cl]2 dimer with a bi-exponential decay of ca. 5 μs and 400 ns. While the photophysics of these complexes differ slightly, their theranostic photodynamic therapy (PDT) effects varied drastically. All of the complexes were biologically active toward melanoma cells. Complexes 2 and 3 were the most cytotoxic, with 230–340 nM activity and selectivity factors for melanoma cells over normal skin fibroblasts of 34 to 40 fold. Complexes 2, 3, and 5 became very potent cytotoxins with light activation, with EC50 values as low as 12–18 nM. This potent nanomolar light-triggered activity combined with a lower dark toxicity resulted in 5 having a phototherapeutic index (PI) margin of almost 275. The bpy coligand led to the least amount of dark toxicity of 1, while phen and pqu produced cytotoxic but selective complexes 2 and 3. The quqo coligand produced the most potent complex 5 for in vitro PDT, both in terms of photocytotoxicity and PI. All Ir(III) complexes exhibited very bright NIR phosphorescence in melanoma cells. The wide range of cytotoxicity and photocytotoxicity effects within a relatively small class of complexes highlights the importance of the identity of the coligand in the biological activity of the π-expansive biscyclometalated Ir(III) complexes, and their bright NIR emission in live cells demonstrates their potential as theranostic PDT agents.

Wang, Li↗

Enhanced charge carrier extraction and transport with interface modification for efficient tin-based perovskite solar cells

Interface modification improves charge carrier extraction in tin-based perovskite solar cells. Tin-based perovskites have become the most promising non-lead perovskites due to their ideal band gap and low toxicity. Although the open circuit voltage of tin-based perovskite solar cells (TPSCs) continues to approach the theoretical value, the short-circuit current is still far from the theoretical value. Here, we describe an interface modification method by regulating the property of hole transport layer, PEDOT:PSS, which improves the surface molecular morphology and the energy level alignment of PEDOT:PSS/perovskite interface. Advanced GIWAXS and IR s-SNOM characterization are conducted to achieve multi-dimensional characterization of nanoscale surface morphology and chemical distribution of PEDOT:PSS. With the multi-attribute optimization, charge carrier extraction and non-radiative recombination are also improved. The resultant TPSCs exhibit a higher power conversion efficiency of 13.32% in compared with the control device of 10.50%, accompanied with an increase in the short-circuit current from 18.10 to 20.50 mA cm −2 and FF from 68.23% to 76.43%. This work demonstrates a reliable strategy for improving charge carrier extraction and device performance for lead-free TPSCs.

Zhao, Zhenzhu↗

High Risk Spacecraft Materials Offgassing

NASA-STD-6001B, Determination of Offgassed Products (Test 7), provides the offgassing characteristics under standardized conditions for materials and assembled articles to be located within habitable spacecraft environments. Experience with Test 7 has found certain material types to be of higher risk for offgassing undesirable compounds aboard spacecraft than others. Formaldehyde and acrolein are historically high T value offgassed components of the offgassed compound target list because they have low spacecraft maximum allowable concentration (SMAC) values assigned by the JSC Toxicology Group. Carbon disulfide, benzene, acrylonitrile, and furan are additional target compounds of concern due to their lower thresholds of toxicity as determined by the JSC Toxicology Group. Materials offgassing siloxanes are also of concern due to their degradation effects on environmental control and life support system (ECLSS) components and performance. Spacecraft materials and articles defined in this manuscript as high risk were identified after examining and condensing data for these compounds of concern from approximately 3000 tests performed over 30 years. Summaries of high risk material and article types based on highest Multi-Purpose Crew Vehicle (MPCV) T values are also presented. Historical analysis shows high risk components are produced largely from test materials and articles in the general categories of electronic/powered components, foams, paints/coatings/films, adhesives/tapes, epoxy/resins, liquids/gels, Nomex® with surface treatments, markers/pens/inks, dry film lubricants, thermoplastics, hygiene items (deodorants, lip balms), and silicone rubber. These data are intended to be a resource for spacecraft materials and processes managers, designers, and toxicologists. High risk materials and articles intended for use aboard spacecraft should be tested in accordance with NASA-STD-6001B Test 7.

Vanessa D Buchanan↗

Association of lenvatinib trough plasma concentrations with lenvatinib-induced toxicities in Japanese patients with thyroid cancer

The aim of this study was to examine the association of lenvatinib-induced adverse events with the trough plasma concentration (C{sub 0}) in Japanese patients with thyroid cancer. Patients received lenvatinib 24 mg as an initial dose, and sequential dose reductions were conducted based on the grade of each side effect. Assessment of adverse events, assay of lenvatinib C{sub 0}, and analysis of clinical laboratory tests were performed at the same time of day and were retrospectively analyzed. There were no significant differences in lenvatinib C{sub 0} among grades of hypertension, proteinuria, hand-foot syndrome, and diarrhea. However, levels of aspartate transaminase, alanine transaminase, and total bilirubin were significantly higher in lenvatinib C{sub 0} quartile (Q) 4 (≥ 88 ng/mL) than in Q1 (< 42 ng/mL) and Q2–3 (42–88 ng/mL). Additionally, platelet counts were highest in the lowest Q1 group. The median dose of lenvatinib in patients with UGT1A1*6/*6 or *6/*28 (poor metabolizers [PMs]) was significantly lower than that in patients with UGT1A1*1/*1 (10 and 14 mg, respectively), whereas the median bilirubin levels were significant higher in UGT1A1 PMs (0.9 and 0.5 mg/dL, respectively). There were no significant differences in median lenvatinib C{sub 0} values between patients with UGT1A1*1/*1 and PMs (58.0 and 50.0 ng/mL, respectively). The threshold between the C{sub 0} and toxicity of lenvatinib may be more than 88 ng/mL. Therefore, the dose of lenvatinib could be controlled to maintain a lower C{sub 0} of less than 88 ng/mL. The target C{sub 0} for lenvatinib as the threshold between the C{sub 0} and optimal response may be in the range from 42 to 88 ng/mL; however, further studies are necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Palliative Radiation Therapy for Advanced Head and Neck Carcinomas: A Phase 2 Study

Purpose: Incurable head and neck cancer is hard to manage with usual palliative care. Radiation therapy (RT) in this setting is sometimes omitted because there is an apprehension that the side effects in the head and neck region might counterbalance the benefits. The objective of this phase 2 study was to evaluate whether highly conformal RT could improve the therapeutic ratio with this comprehensive Quality of Life (QOL) and toxicity evaluation. Methods and Materials: Patients from 2 academic centers, deemed unfit for radical treatment because of their poor medical condition or advanced cancer stage by an experienced tumor board, were offered 25 Gy in 5 daily intensity modulated RT fractions over 1 week to the symptomatic tumor volume. QOL was evaluated with the European Organization for Research and Treatment of Cancer QLQ-C15-PAL and QLQ-H&N35 questionnaires, and toxicities with the Common Terminology Criteria for Adverse Events version 4.0. Survival and time to tumor progression were calculated with the Kaplan-Meier method. Results: Thirty-two patients were recruited, of whom 66% had at least T4, N3, or M1 disease. The QOL questionnaires completion rate was 86%. Eighty-eight percent of patients received the planned dose. The median overall survival and progression-free survival times were, respectively, 6.5 and 3.2 months. No grade 4 or 5 toxicity was seen. Only 13% of patients had any grade 3 toxicities, and 17% of patients reported no toxicity at all. The QOL was equal or improved, and head and neck symptoms remained equal to or lower than the baseline values for most patients at up to 6 months. Eighty-five percent of patients would have chosen to receive this RT regimen again when asked. Conclusions: This palliative RT regimen was highly tolerable and effective in preserving or improving self-reported QOL in most patients for up to 6 months, which corresponds to this population's median overall survival. Given the minimal side effects, intensification could be considered to achieve longer locoregional control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards using bacterial microcompartments as a platform for spatial metabolic engineering in the industrially important and metabolically versatile Zymomonas mobilis

Advances in synthetic biology have enabled the incorporation of novel biochemical pathways for the production of high-value products into industrially important bacterial hosts. However, attempts to redirect metabolic fluxes towards desired products often lead to the buildup of toxic or undesirable intermediates or, more generally, unwanted metabolic cross-talk. The use of shells derived from self-assembling protein-based prokaryotic organelles, referred to as bacterial microcompartments (BMCs), as a scaffold for metabolic enzymes represents a sophisticated approach that can both insulate and integrate the incorporation of challenging metabolic pathways into industrially important bacterial hosts. Here we took a synthetic biology approach and introduced the model shell system derived from the myxobacterium Haliangium ochraceum (HO shell) into the industrially relevant organism Zymomonas mobilis with the aim of constructing a BMC-based spatial scaffolding platform. SDS-PAGE, transmission electron microscopy, and dynamic light scattering analyses collectively demonstrated the ability to express and purify empty capped and uncapped HO shells from Z. mobilis . As a proof of concept to internally load or externally decorate the shell surface with enzyme cargo, we have successfully targeted fluorophores to the surfaces of the BMC shells. Overall, our results provide the foundation for incorporating enzymes and constructing BMCs with synthetic biochemical pathways for the future production of high-value products in Z. mobilis .

59 BASIC BIOLOGICAL SCIENCES↗

Assessing the Renal Toxicity of Capstone Depleted Uranium Oxides and Other Uranium Compounds

The primary target for uranium toxicity is the kidney. The most frequently used guideline for uranium kidney burdens is the International Commission on Radiation Protection (ICRP) value of 3 µg U/g kidney, a value that is based largely upon chronic studies in animals. In the present effort, we have developed a risk model equation to assess potential outcomes of acute uranium exposure. Twenty-seven previously published case studies in which workers were acutely exposed to soluble compounds of uranium (as a result of workplace accidents) were analyzed. Kidney burdens of uranium for these individuals were determined based on uranium in the urine, and correlated with health effects observed over a period of up to 38 years. Based upon the severity of health effects, each individual was assigned a score (- to +++) and then placed into an Effect Group. A discriminant analysis was used to build a model equation to predict the Effect Group based on the amount of uranium in the kidneys. The model equation was able to predict the Effect Group with 85% accuracy. The risk model was used to predict the Effect Group for Soldiers exposed to DU as a result of friendly fire incidents during the 1991 Gulf War. This model equation can also be used to predict the Effect Group of new cases in which acute exposures to uranium have occurred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Volumetric Modulated Arc Therapy Planning for Primary Prostate Cancer With Selective Intraprostatic Boost Determined by {sup 18}F-Choline PET/CT

Purpose: This study evaluated expected tumor control and normal tissue toxicity for prostate volumetric modulated arc therapy (VMAT) with and without radiation boosts to an intraprostatically dominant lesion (IDL), defined by {sup 18}F-choline positron emission tomography/computed tomography (PET/CT). Methods and Materials: Thirty patients with localized prostate cancer underwent {sup 18}F-choline PET/CT before treatment. Two VMAT plans, plan{sub 79} {sub Gy} and plan{sub 100-105} {sub Gy}, were compared for each patient. The whole-prostate planning target volume (PTV{sub prostate}) prescription was 79 Gy in both plans, but plan{sub 100-105} {sub Gy} added simultaneous boost doses of 100 Gy and 105 Gy to the IDL, defined by 60% and 70% of maximum prostatic uptake on {sup 18}F-choline PET (IDL{sub suv60%} and IDL{sub suv70%}, respectively, with IDL{sub suv70%} nested inside IDL{sub suv60%} to potentially enhance tumor specificity of the maximum point dose). Plan evaluations included histopathological correspondence, isodose distributions, dose-volume histograms, tumor control probability (TCP), and normal tissue complication probability (NTCP). Results: Planning objectives and dose constraints proved feasible in 30 of 30 cases. Prostate sextant histopathology was available for 28 cases, confirming that IDL{sub suv60%} adequately covered all tumor-bearing prostate sextants in 27 cases and provided partial coverage in 1 case. Plan{sub 100-105} {sub Gy} had significantly higher TCP than plan{sub 79} {sub Gy} across all prostate regions for α/β ratios ranging from 1.5 Gy to 10 Gy (P<.001 for each case). There were no significant differences in bladder and femoral head NTCP between plans and slightly lower rectal NTCP (endpoint: grade ≥ 2 late toxicity or rectal bleeding) was found for plan{sub 100-105} {sub Gy}. Conclusions: VMAT can potentially increase the likelihood of tumor control in primary prostate cancer while observing normal tissue tolerances through simultaneous delivery of a steep radiation boost to a {sup 18}F-choline PET-defined IDL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗