Rationale and Methods for Archival Sampling and Analysis of Atmospheric Trace Chemical Contaminants On Board Mir and Recommendations for the International Space Station

Collection and analysis of spacecraft cabin air samples are necessary to assess the cabin air quality with respect to crew health. Both toxicology and engineering disciplines work together to achieve an acceptably clean cabin atmosphere. Toxicology is concerned with limiting the risk to crew health from chemical sources, setting exposure limits, and analyzing air samples to determine how well these limits are met. Engineering provides the means for minimizing the contribution of the various contaminant generating sources by providing active contamination control equipment on board spacecraft and adhering to a rigorous material selection and control program during the design and construction of the spacecraft. A review of the rationale and objectives for sampling spacecraft cabin atmospheres is provided. The presently-available sampling equipment and methods are reviewed along with the analytical chemistry methods employed to determine trace contaminant concentrations. These methods are compared and assessed with respect to actual cabin air quality monitoring needs. Recommendations are presented with respect to the basic sampling program necessary to ensure an acceptably clean spacecraft cabin atmosphere. Also, rationale and recommendations for expanding the scope of the basic monitoring program are discussed.

Perry, J. L.↗

Development of Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

Ambient mass spectrometry is being investigated as a new method for rapidly characterizing trace inorganic species, including nuclear materials. SRNL is currently developing electrospray ionization (ESI) and paper spray ionization (PSI) methods for mass spectrometry for the detection of trace inorganic compounds JEOL AccuTOF™-DART ® LP 4G mass spectrometer. Sample analysis generates a complex three-dimensional data set with 10 2 -10 3 individual mass spectra spread temporally. To improve the quality and ease of data extraction from this amount of information, a simple data analysis pipeline written in R/R Studio has been improved and expanded upon. Specifically, the software now has header inputs to set base input/output filenames, isotopes of interest, and a list of concentrations analyzed on the instrument. Using list-based structures to enable batch processing of many concentrations at once, it then loads each file, extracts the relevant intensities for masses of interest from each spectrum, and iterates through each concentration to generate graphs of internal standard & analyte correlations, measured isotope ratios, and total ion chromatograms. It then filters the data to remove points at background levels or at the detector saturation limit. Using this filtered data, the pipeline re-creates the graphs to reveal high-quality information from a low-quality raw dataset. All graphs of the R software then output to PowerPoint format. Additionally, faster 3D visualization functionality was added to the pipeline for viewing the entire data file produced by the instrument as an intensity map. With these data analysis tools ready, samples of strontium nitrate/yttrium nitrate as an analyte/internal standard combination were measured on the AccuTOF. From the filtered data, calibration curves were prepared and limits of detection (LOD) of 1 ppb for ESI-MS and 20 ppb for PSI-MS were obtained. The quality available from the calibration curves and the low limits of detection demonstrate the value of the instrument/analysis pipeline system in characterizing trace inorganics.

47 OTHER INSTRUMENTATION↗

Analysis of atmospheric trace constituents from high resolution infrared balloon-borne and ground-based solar absorption spectra

Results of ongoing studies of high-resolution solar absorption spectra aimed at the identification and quantification of trace constituents of importance in the chemistry of the stratosphere and upper troposphere are presented. An analysis of balloon-borne and ground-based spectra obtained at 0.0025/cm covering the 700-2200/cm interval is presented. The 0.0025/cm spectra, along with corresponding laboratory spectra, improves the spectral line parameters, and thus the accuracy of quantifying trace constituents. Results for COF2, F22, SF6, and other species are presented. The retrieval methods used for total column density and altitude distribution for both ground-based and balloon-borne spectra are also discussed.

Goldman, A.↗

A Reference Based Analysis Framework for Analyzing System Call Traces

Reference based analysis (RBA) is a novel data mining tool for exploring a test data set with respect to a reference data set. The power of RBA lies in it ability to transform any complex data type, such as symbolic sequences and multi-variate categorical data instances, into a multivariate continuous representation. The transformed representation not only allows visualization of the complex data, which cannot be otherwise visualized in its original form, but also allows enhanced anomaly detection in the transformed feature space. We demonstrate the application of the RBA framework in analyzing system call traces and show how the transformation results in improved intrusion detection performance over state of art data mining based intrusion detection methods developed for system call traces.

99 GENERAL AND MISCELLANEOUS↗

Thermal radiation characteristics of nonisothermal cylindrical enclosures using a numerical ray tracing technique

Analysis of energy emitted from simple or complex cavity designs can lead to intricate solutions due to nonuniform radiosity and irradiation within a cavity. A numerical ray tracing technique was applied to simulate radiation propagating within and from various cavity designs. To obtain the energy balance relationships between isothermal and nonisothermal cavity surfaces and space, the computer code NEVADA was utilized for its statistical technique applied to numerical ray tracing. The analysis method was validated by comparing results with known theoretical and limiting solutions, and the electrical resistance network method. In general, for nonisothermal cavities the performance (apparent emissivity) is a function of cylinder length-to-diameter ratio, surface emissivity, and cylinder surface temperatures. The extent of nonisothermal conditions in a cylindrical cavity significantly affects the overall cavity performance. Results are presented over a wide range of parametric variables for use as a possible design reference.

Baumeister, Joseph F.↗

User's manual for University of Arizona APART program (Analysis Program - Arizona Radiation Trace)

A description and operating instructions for the Analysis Program Arizona Radiation Trace (APART) are given. This is a computer program that is able to efficiently and accurately predict the off-axis rejection characteristics of unwanted stray radiation for complex rotationally symmetric optical systems. The program first determines the critical objects or areas that scatter radiation to the image plane either directly or through imaging elements: this provides the opportunity to modify, if necessary, the design so that the number of critical areas seen by the image plane is reduced or the radiation to these critical areas is minimized. Next, the power distribution reaching the image plane and a sectional power map of all internal surfaces are computed. Angular information is also provided that relates the angle by which the radiation came into a surface to the angle by which the radiation is scattered out of the surface.

Breault, R. P.↗

Trace-based performance analysis for the petascale simulation code FLASH

Performance analysis of applications on modern high-end petascale systems is increasingly challenging due to the rising complexity and quantity of the computing units. This paper presents a performance-analysis study using the Vampir performance-analysis tool suite, which examines application behavior as well as the fundamental system properties. This study was carried out on the Jaguar system at Oak Ridge National Laboratory, the fastest computer on the November 2009 Top500 list. We analyzed the FLASH simulation code that is designed to be scaled with tens of thousands of CPU cores, which means that using existing performance-analysis tools is very complex. The study reveals two classes of performance problems that are relevant for very high CPU counts: MPI communication and scalable I/O. For both, solutions are presented and verified. Finally, the paper proposes improvements and extensions for event tracing tools in order to allow scalability of the tools towards higher degrees of parallelism.

Computer Science↗

An analysis of the Antarctic Halogen Occultation Experiment trace gas observations

Analysis of the version 16 Halogen Occultation Experiment (HALOE) CH4 data shows that this long-lived trace gas is well correlated with potential vorticity (PV) computed from National Meteorological Center balanced winds. Analyzing late September and October 1992 data, we show that very low CH4 values are confined to the interior of a vortex edge defined by the maximum gradient in PV. The CH4 and HF time tendency is used to estimate the descent rate in the Antarctic vortex. After removing a component of the trend correlated with the HALOE sampling pattern, we compute the lower stratosphere vertical descent rates and net heaing rates in the spring Antarctic vortex. Our computations of the spring Antarctic vortex heating rates give -0.5 to -0.1 K/day. Over the winter season, the overall lower stratospheric descent rate averages about 1.8-1.5 km/month. These computations are in line with radiative transfer estimates of the heating and descent rate. The HALOE data thus appear to be consistent with the picture of an isolated lower stratospheric Antarctic vortex.

Schoeberl, Mark R.↗

Trace-level perchlorate analysis of impacted groundwater by elevated gold ellipse dimer nanoantenna surface-enhanced Raman scattering

Perchlorate (ClO 4 - ) contamination has received increased attention the past two decades because of health concerns from its impact on thyroid function coupled with its environmental ubiquity and persistence. In this paper, we demonstrate the detection of ClO 4 - below micromolar (<1 × 10 -6 moles l -1 ) levels using a portable Raman instrument integrated with novel elevated gold (Au) ellipse dimer nanoantenna surface enhanced Raman scattering (SERS) architectures. The ellipse dimer nanoantenna architectures demonstrate improved ClO 4 - detection limits over previously reported SERS substrates while maintaining good reproducibility. The impact of chloride (Cl - ), nitrate (NO 3 - ), and sulfate (SO 4 2- ) interferences on the detection efficiency is systematically evaluated; SO 4 2- is found to exhibit the largest interference effect at low concentrations while at higher ion concentrations the interference effects among ions are similar. Finally and additionally, ClO 4 - concentrations on the order of 1 mg l -1 are determined in groundwaters collected from an US Department of Defense Navy site demonstrating the applicability of these SERS architectures for the rapid, field detection of trace-level ClO 4 - contamination within complex environmental samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Airborne infrared interferometric observations and analysis of stratospheric trace constituents

Infrared interferometric observations of key trace constituents of the stratosphere have been obtained. The NASA Lear Airborne Observatory with the Grumman airborne interferometer system was flown in the lower stratosphere at an altitude of 13.7 km to obtain transmission spectra in the 2800-6000 per cm region at a resolution of 2.5 per cm using the moon as a source. An atmospheric modeling program and the AFGL line parameter atlas are used to identify H2O, CH4, O3 and other trace constituents and to derive stratospheric column densities (molecules/sq cm).

Smith, L. L.↗

Fracture trace expression and analysis in radar imagery of rain forest terrain (Peru)

Mapping of minor lineaments from radar imagery of the rain forest in southeast Peru is biased due to the selective suppression of some topography which results from the observation geometry of the imaging radar system and the varied perception of lineaments on the imagery by different interpreters. Team analysis of the imagery compensates for several of the sources of bias, and results in the clear recognition of differing regimes within the regional fracture field in the study area.

Martin-Kaye, P. H. A.↗

Seventy-meter antenna performance predictions: GTD analysis compared with traditional ray-tracing methods

A comparative analysis was performed, using both the Geometrical Theory of Diffraction (GTD) and traditional pathlength error analysis techniques, for predicting RF antenna gain performance and pointing corrections. The NASA/JPL 70 meter antenna with its shaped surface was analyzed for gravity loading over the range of elevation angles. Also analyzed were the effects of lateral and axial displacements of the subreflector. Significant differences were noted between the predictions of the two methods, in the effect of subreflector displacements, and in the optimal subreflector positions to focus a gravity-deformed main reflector. The results are of relevance to future design procedure.