Search NASA⌕ Search

SEARCH · Search NASA

Results for “ultraviolet fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Qualitative and quantitative flow visualization technique using ozone

The paper describes a new flow-visualization technique based on the absorption of ultraviolet light by ozone. Ozone is an excellent tracer, because as a gas it has the same effective physical properties as air. Ozone strongly absorbs the principal line (253.7 nm) of a mercury lamp, so that when an ozone-traced flow passes between a mercury lamp and a fluorescent screen, a sharp, shadow-like image of the ozone tracer is cast on the screen. Quantitative photometry can be carried out by replacing the screen with ultraviolet detectors that yield the path-integrated column density of ozone in the flow. High-speed quantitative point monitoring (10 Hz at 10 ppb O3) is possible with capillary probes and chemiluminescent analysis.

Dickerson, R. R.↗

Amplified spontaneous emission in the extreme ultraviolet by expanding xenon clusters

Focused short-wavelength free-electron laser (FEL) pulses interacting with gas phase samples can induce by inner-shell ionization a short-lived population inversion, followed by coherent collective emission of directed, short, and strong radiation bursts. We extend our studies into the warm-dense matter (WDM) regime by investigating the nanoplasmas produced in an ensemble of nanometer-sized clusters by FEL irradiation. Here, additional pathways can also lead to strong, laserlike emission: Electron-ion collisions can yield a long-lived population inversion, and subsequent amplified spontaneous emission. We observe amplified spontaneous emission (ASE) in the extreme ultraviolet in xenon clusters excited by soft x-ray FEL pulses, we diagnose the generated nanoplasmas by fluorescence spectroscopy, and we study under various cluster and FEL parameters the directed ASE from the Xe 2+ 65 nm line. We show its exponential increase as a function of FEL irradiation power, and an accompanying collisional broadening of the emission spectra. These findings are corroborated by extensive numerical simulations based on theory, combining detailed hydrodynamic and kinetic simulations with time-dependent calculations of radiation transport, amplification, and collective emission in the WDM nanoplasma. Furthermore, our theoretical findings underline that population inversion is due to electron-ion collisions and that the observed decoherence processes can be empirically characterized by a phenomenological decoherence time in the range of 100–200 fs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-latitude nitric oxide in the lower thermosphere

High-latitude observations of fluorescent nitric oxide gamma bands were made before and during a strong magnetic storm with the Ogo 4 ultraviolet spectrometer. Brightness measurements of the (1-0) gamma band of nitric oxide indicate a slow buildup of NO during the disturbed period. The NO column density reaches a value as high as a factor of 8 greater than the midlatitude value and shows no correlation with the brightness of the instantaneous aurora. A time-dependent model calculation indicates that the ionization and dissociation of N2 by auroral electrons can increase the NO and N(4-S) densities. This increase is dependent on the intensity and duration of the auroral precipitation and on the branching ratio of N(2-D) production by dissociation of N2. A steady state is not reached for NO until 100,000 sec in an aurora characterized by an energy flux of 10 ergs per sq cm sec. Dissociation by the solar ultraviolet radiation competes with horizontal and vertical transport as a loss process for the nitric oxide produced by the aurora. A high NO(plus)/O2(plus) ratio is to be expected in the period following a strong auroral precipitation.

Gerard, J.-C.↗

Production of N(+)-asterisk from N2 + hnu - Effective EUV emission yields from laboratory and dayglow data

Photodissociative ionization of N2 into the unbound N2(+) H 2Sigma-g(+) state is identified as the parentage of a number of N(+) and N-excited states that contribute to the u.v. dayglow. Yields have been obtained for the production of extreme ultraviolet emission lines of N(+) and N from a laboratory experiment using a broadband synchrotron radiation source with fluorescence spectroscopy. The yields are termed 'effective', in that they are constant percentages of the H state cross section. These are compared wih effective yields needed to reproduce N II 1085 and 916 A lines from four dayglow observations using a model of solar energy deposition and photoelectron production and loss in the earth's thermosphere. The 1085 A effective yield measured in the laboratory (18 percent) agrees with that from the dayglow data (average of 17 percent) to well within experimental uncertainties. Thus, it is concluded that photodissociative ionization of N2 is the primary source of the N II 1085 A dayglow. However, there is an order of magnitude discrepancy among the various dayglow observations of the 1085/916 intensity ratio, only one of which is consistent with the laboratory observation of 4.4. Neither contamination by other dayglow features nor atmospheric extinction can account for the disparities. Laboratory measurements of N2 and O2 absorption cross sections at these wavelengths are also reported.

Meier, R. R.↗

Medium resolution studies of extreme ultraviolet emission from N2 by electron impact - The effect of predissociation on the emission cross section of the b 1Pi(u) state

The electron impact induced fluorescence spectrum of N2 is measured in the 102-134 nm range at a 0.05 nm spectral resolution. The spectral measurements provide the emission cross sections of the transitions of the b 1Pi(u)-X 1Sigma(+)g Birge-Hopfield I-band system. The structure and vibrational population distribution of this system are strongly affected by a configuration interaction of the valence b 1Pi(u) and Rydberg c 1Pi(u) and o 1Pi(u) states. The excitation function (0-400 eV) for the b-X (1,2) transition is measured and a modified Born approximation analytic model is applied to calculate the oscillator strength for the b 1Pi(u)-X band system. With the exception of the v-prime = 1 level, vibrational levels of the b 1Pi(u) state predissociate with a branching ratio of between 0.95 and 1.00. Predissociation of the b 1Pi(u) state contributes approximately six percent of the total dissociation cross section of N2 by electron impact at 100 eV.

James, Geoffrey K.↗

Temperature-dependent x-ray fluorescent response from thermographic phosphors under x-ray excitation

Phosphor thermometry has been successfully applied within several challenging environments. Typically, the thermographic phosphors are excited by an ultraviolet light source, and the temperature-dependent spectral or temporal response is measured. However, this is challenging or impossible in optically thick environments. In addition, emission from other sources (e.g., a flame) may interfere with the optical phosphor emission. Furthermore, a temperature dependent x-ray excitation/emission could alleviate these issues as x-rays could penetrate obscurants with no interference from flame luminosity. In addition, x-ray emission could allow for thermometry within solids while simultaneously x-ray imaging the structural evolution. In this study, select thermographic phosphors were excited via x-ray radiation, and their x-ray emission characteristics were measured at various temperatures. Several of the phosphors showed varying levels of temperature dependence with the strongest sensitivity occurring for YAG:Dy and ZnGa 2 O 4 :Mn. This approach opens a path for less intrusive temperature measurements, particularly in optically opaque multiphase and solid phase combustion environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Molecular fluorescence as a monitor of minor stratospheric constituents

The potential of molecular fluorescence was assessed as a stratospheric monitor of the concentrations of various minor species. Seventeen molecules were considered and all spectral regions from the vacuum ultraviolet through to the infrared are included. The exercise has produced few surprises; however, further confirmation has emerged as to the feasibility of this sensitive technique for monitoring stratospheric OH, NO2, and SO2, sufficient to warrant its development as analytical flight hardware for these species. All the other molecules have been eliminated with the exception of C10 which appears to have promise but requires additional information before its detection limit can be calculated; its fluorescence spectrum is as yet uninvestigated. A handbook for molecular fluorescence is presented, and a compilation of all reported studies for simple molecules using line source excitation is included.

Schofield, K.↗

Visible-Light-Responsive Catalysts Using Quantum Dot-Modified TiO2 for Air and Water Purification

Photocatalysis, the oxidation or reduction of contaminants by light-activated catalysts, utilizing titanium dioxide (TiO2) as the catalytic substrate has been widely studied for trace contaminant control in both air and water applications. The interest in this process is due primarily to its low energy consumption and capacity for catalyst regeneration. Titanium dioxide requires ultraviolet light for activation due to its relatively large band gap energy of 3.2 eV. Traditionally, Hg-vapor fluorescent light sources are used in PCO reactors; however, the use of mercury precludes the use of this PCO technology in a spaceflight environment due to concerns over crew Hg exposure. The development of a visible-light responsive (VLR) TiO2-based catalyst would eliminate the concerns over mercury contamination. Further, VLR development would allow for the use of ambient visible solar radiation or highly efficient LEDs, both of which would make PCO approaches more efficient, flexible, economical, and safe. Though VLR catalyst development has been an active area of research for the past two decades, there are few commercially available VLR catalysts. Those VLR catalysts that are commercially available do not have adequate catalytic activity, in the visible region, to make them competitive with those operating under UV irradiation. This study was initiated to develop more effective VLR catalysts through a novel method in which quantum dots (QD) consisting of narrow band gap semiconductors (e.g., CdS, CdSe, PbS, ZnSe, etc.) are coupled to TiO2 via two preparation methods: 1) photodeposition and 2) mechanical alloying using a high-speed ball mill. A library of catalysts was developed and screened for gas and aqueous phase applications using ethanol and 4-chlorophenol as the target contaminants, respectively. Both target compounds are well studied in photocatalytic systems and served as model contaminants for this research. Synthesized catalysts were compared in terms of preparation method, nature of the quantum dots, and dosage of quantum dots.

visible light↗

Visible-Light Responsive Catalysts Using Quantum Dot-Modified TiO2 for Air and Water Purification

Photocatalysis, the oxidation or reduction of contaminants by light-activated catalysts, utilizing titanium dioxide (TiO2) as the catalytic substrate has been widely studied for trace contaminant control in both air and water applications. The interest in this process is due primarily to its low energy consumption and capacity for catalyst regeneration. Titanium dioxide requires ultraviolet light for activation due to its relatively large band gap energy of 3.2 eV. Traditionally, Hg-vapor fluorescent light sources are used in PCO reactors; however, the use of mercury precludes the use of this PCO technology in a spaceflight environment due to concerns over crew Hg exposure.

visible light↗

Atomic and molecular fluorescence as a stratospheric species monitor

The results of an investigation are presented evaluating the potential of atomic and molecular fluorescence as a stratospheric monitor of the concentrations of any one of 18 minor species: Cl, Cl2, ClO, ClO2, CO, H2, HCHO, HCl, HNO2, HNO3, H2S, NH3, NO, NO2, N2O, O, OH, and SO2. All spectral regions from the vacuum ultraviolet through the infrared were included. It was found that suitable systems can be constructed for the stratospheric monitoring of CO (5 ppb), NO2 (less than 1 ppb), OH (0.2 ppt), and O (50-200 ppt). The fluorescence sensitivities for Cl (0.5-1.0 ppt), H2 (0.2 ppm at 10 torr) and SO2 (1-10 ppb) are marginally insufficient with current technology.

Schofield, K.↗

Multiplexed structured imaging of laser induced fluorescence at 10 GHz rate

The frame rate of conventional high-speed imaging devices is limited by exposure time and signal read-out time. Structured imaging is able to push the frame rate beyond the limit of the imaging device. This work demonstrates the feasibility of potential TeraHz rate structured imaging with a multiplexed structured imaging setup. In this work, a multiplexed structured image capture system was employed to image UV laser induced krypton-II emission lines at 10 GHz. The measured emission intensity of the 764 nm line over time suggests a temporal resolution of 97 ps. The temporal resolution is adjustable, and the frame rate can be further increased to the TeraHz level.

47 OTHER INSTRUMENTATION↗

Extended near infrared emission from visual reflection nebulae

Extended near infrared (2 to 5 microns) emission was observed from three visual reflection nebulae, NGC 7023, 2023, and 2068. The emission from each nebula consists of a smooth continuum, which can be described by a greybody with a color temperature of 1000 K, and emission features at 3.3 and 3.4 microns. The continuum emission cannot be explained by free-free emission, reflected light, or field stars, or by thermal emission from grains, with commonly accepted ratios of infrared to ultraviolet emissivities, which are in equilibrium with the stellar radiation field. A possible explanation is thermal emission from grains with extremely low ratios of infrared to ultraviolet emissivities, or from grains with a temperature determined by mechanisms other than equilibrium radiative heating. Another possibility is continuum fluorescence.

Sellgren, K.↗

Extended near-infrared emission from visual reflection nebulae

Extended near infrared (2 to 5 microns) emission was observed from three visual reflection nebulae, NGC 7023, 2023, and 2068. The emission from each nebula consists of a smooth continuum, which can be described by a greybody with a color temperature of 1000 K, and emission features at 3.3 and 3.4 microns. The continuum emission cannot be explained by free-free emission, reflected light, or field stars, or by thermal emission from grains, with commonly accepted ratios of infrared to ultraviolet emissivities, which are in equilibrium with the stellar radiation field. A possible explanation is thermal emission from grains with extremely low ratios of infrared to ultraviolet emissivities, or from grains with a temperature determined by mechanisms other than equilibrium radiative heating. Another possibility is continuum fluorescence. Previously announced in STAR N83-25629

Sellgren, K.↗

OH Planar Laser Induced Fluorescence (PLIF) Measurements for the Study of High Pressure Flames: An Evaluation of a New Laser and a New Camera System

Planar laser induced fluorescence (PLIF) is used by the Combustion Branch at the NASA Glenn Research Center (NASA Glenn) to assess the characteristics of the flowfield produced by aircraft fuel injectors. To improve and expand the capabilities of the PLIF system new equipment was installed. The new capabilities of the modified PLIF system are assessed by collecting OH PLIF in a methane/air flame produced by a flat flame burner. Specifically, the modifications characterized are the addition of an injection seeder to a Nd:YAG laser pumping an optical parametric oscillator (OPO) and the use of a new camera with an interline CCD. OH fluorescence results using the injection seeded OPO laser are compared to results using a Nd:YAG pumped dye laser with ultraviolet extender (UVX). Best settings of the new camera for maximum detection of PLIF signal are reported for the controller gain and microchannel plate (MCP) bracket pulsing. Results are also reported from tests of the Dual Image Feature (DIF) mode of the new camera which allows image pairs to be acquired in rapid succession. This allows acquisition of a PLIF image and a background signal almost simultaneously. Saturation effects in the new camera were also investigated and are reported.

Tedder, Sarah↗

Laser-induced fluorescence of space-exposed polyurethane

The object of this work was to utilize laser-induced fluorescence technique to characterize several samples of space-exposed polyurethane. These samples were flown on the Long Duration Exposure Facility (LDEF), which was in a shuttle-like orbit for nearly 6 years. Because of our present work to develop laser-induced-fluorescence inspection techniques for polymers, space-exposed samples and controls were lent to us for evaluation. These samples had been attached to the outer surface of LDEF; therefore, they were subjected to thermal cycling, solar ultraviolet radiation, vacuum, and atomic oxygen. It is well documented that atomic oxygen and ultraviolet exposure have detrimental effects on many polymers. This was a unique opportunity to make measurements on material that had been naturally degraded by an unusual environment. During our past work, data have come from artificially degraded samples and generally have demonstrated a correlation between laser-induced fluorescence and tensile strength or elasticity.

Hill, Ralph H., Jr.↗

ELM: Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and bright-field microscope designed to meet key objectives defined in the 2016 NASA Europa Lander Study Report, including the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In situ Research imager, designed and built at NASA Ames Research Center, for the autonomous study of microbial biology in low Earth orbit. For ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line 10, 1.0, and 0.2 μm pore-size filters to capture successively smaller particles for imaging. For bright-field imaging, ELM uses deep-ultraviolet, ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect biosignatures as small as 0.2 μm in size is achieved by imaging native fluorescence and using fluorescence microscopy stains to identify key structural and functional indicators of microbial life (proteins, lipids, nucleic acids). For fluorescence imaging, ELM uses 265, 370, 470, and 530 nm LEDs with five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging enables the detection of a wide range of molecular species and their rough classification. Excitation at 265 nm allows for the detection of smaller polycyclic aromatic hydrocarbons (PAH), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and separated from organic fluorescence, allowing the recognition and in some cases classification, of minerals and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Richard C Quinn↗

Improved Charge-Transfer Fluorescent Dyes

Improved charge-transfer fluorescent dyes have been developed for use as molecular probes. These dyes are based on benzofuran nuclei with attached phenyl groups substituted with, variously, electron donors, electron acceptors, or combinations of donors and acceptors. Optionally, these dyes could be incorporated as parts of polymer backbones or as pendant groups or attached to certain surfaces via self-assembly-based methods. These dyes exhibit high fluorescence quantum yields -- ranging from 0.2 to 0.98, depending upon solvents and chemical structures. The wavelengths, quantum yields, intensities, and lifetimes of the fluorescence emitted by these dyes vary with (and, hence, can be used as indicators of) the polarities of solvents in which they are dissolved: In solvents of increasing polarity, fluorescence spectra shift to longer wavelengths, fluorescence quantum yields decrease, and fluorescence lifetimes increase. The wavelengths, quantum yields, intensities, and lifetimes are also expected to be sensitive to viscosities and/or glass-transition temperatures. Some chemical species -- especially amines, amino acids, and metal ions -- quench the fluorescence of these dyes, with consequent reductions in intensities, quantum yields, and lifetimes. As a result, the dyes can be used to detect these species. Another useful characteristic of these dyes is a capability for both two-photon and one-photon absorption. Typically, these dyes absorb single photons in the ultraviolet region of the spectrum (wavelengths < 400 nm) and emit photons in the long-wavelength ultraviolet, visible, and, when dissolved in some solvents, near-infrared regions. In addition, these dyes can be excited by two-photon absorption at near-infrared wavelengths (600 to 800 nm) to produce fluorescence spectra identical to those obtained in response to excitation by single photons at half the corresponding wavelengths (300 to 400 nm). While many prior fluorescent dyes exhibit high quantum yields, solvent-polarity- dependent fluorescence behavior, susceptibility to quenching by certain chemical species, and/or two-photon fluorescence, none of them has the combination of all of these attributes. Because the present dyes do have all of these attributes, they have potential utility as molecular probes in a variety of applications. Examples include (1) monitoring curing and deterioration of polymers; (2) monitoring protein expression; (3) high-throughput screening of drugs; (4) monitoring such chemical species as glucose, amines, amino acids, and metal ions; and (5) photodynamic therapy of cancers and other diseases.

Meador, Michael↗

Development of a cosmic ray oriented trigger for the fluorescence telescope on EUSO-SPB2

The Extreme Universe Space Observatory on a Super Pressure Balloon 2 (EUSO-SPB2), in preparation, aims to make the first observations of Ultra-High Energy Cosmic Rays (UHECRs) from near space using optical techniques. EUSO-SPB2 will prototype instrumentation for future satellite-based missions, including the Probe of Extreme Multi-Messenger Astrophysics (POEMMA) and K-EUSO. The payload will consist of two telescopes. The first is a Cherenkov telescope (CT) being developed to quantify the background for future below-the-limb very high energy (E 10 PeV) astrophysical neutrino observations, and the second is a fluorescence telescope (FT) being developed for detection of UHECRs. The FT will consist of a Schmidt telescope, and a 6192 pixel ultraviolet camera with an integration time of 1.05 s. The first step in the data acquisition process for the FT is a hardware level trigger in order to decide which data to record. In order to maximize the number of UHECR induced extensive air showers (EASs) which can be detected, a novel trigger algorithm has been developed based on the intricacies and limitations of the detector. Finally, the expected performance of the trigger has been characterized by simulations and, pending hardware verification, shows that EUSO-SPB2 is well positioned to attempt the first near-space observation of UHECRs via optical techniques.

79 ASTRONOMY AND ASTROPHYSICS↗