Online updating of a Markovian solar forecast representation
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
A region-wide Energy Imbalance Market (EIM) was recently proposed by the Western Electricity Coordinating Council (WECC). In order for the Western Area Power Administration (Western) to make more informed decisions regarding its involvement in the EIM, Western asked Argonne National Laboratory (Argonne) to review the EIM benefits study (the October 2011 revision) performed by Energy and Environmental Economics, Inc. (E3). Key components of the E3 analysis made use of results from a study conducted by the National Renewable Energy Laboratory (NREL); therefore, we also reviewed the NREL work. This report examines E3 and NREL methods and models used in the EIM study. Estimating EIM benefits is very challenging because of the complex nature of the Western Interconnection (WI), the variability and uncertainty of renewable energy resources, and the complex decisions and potentially strategic bidding of market participants. Furthermore, methodologies used for some of the more challenging aspects of the EIM have not yet matured. This review is complimentary of several components of the EIM study. Analysts and modelers clearly took great care when conducting detailed simulations of the WI using well-established industry tools under stringent time and budget constraints. However, it is our opinion that the following aspects of the study and the interpretation of model results could be improved upon in future analyses. The hurdle rate methodology used to estimate current market inefficiencies does not directly model the underlying causes of sub-optimal dispatch and power flows. It assumes that differences between historical flows and modeled flows can be attributed solely to market inefficiencies. However, flow differences between model results and historical data can be attributed to numerous simplifying assumptions used in the model and in the input data. We suggest that alternative approaches be explored in order to better estimate the benefits of introducing market structures like the EIM. In addition to more efficient energy transactions in the WI, the EIM would reduce the amount of flexibility reserves needed to accommodate forecast errors associated with variable production from wind and solar energy resources. The modeling approach takes full advantage of variable resource diversity over the entire market footprint, but the projected reduction in flexibility reserves may be overly optimistic. While some reduction would undoubtedly occur, the EIM is only an energy market and would therefore not realize the same reduction in reserves as an ancillary services market. In our opinion the methodology does not adequately capture the impact of transmission constraints on the deployment of flexibility reserves. Estimates of flexibility reserves assume that forecast errors follow a normal distribution. Improved estimates could be obtained by using other probability distributions to estimate up and down reserves to capture the underlying uncertainty of these resources under specific operating conditions. Also, the use of a persistence forecast method for solar is questionable, because solar insolation follows a deterministic pattern dictated by the sun's path through the sky. We suggest a more rigorous method for forecasting solar insolation using the sun's relatively predictable daily pattern at specific locations. The EIM study considered only one scenario for hydropower resources. While this scenario is within the normal range over the WI footprint, it represents a severe drought condition in the Colorado River Basin from which Western schedules power. Given hydropower's prominent role in the WI, we recommend simulating a range of hydropower conditions since the relationship between water availability and WI dispatch costs is nonlinear. Also, the representation of specific operational constraints faced by hydropower operators in the WI needs improvements. The model used in the study cannot fully capture all of the EIM impacts and complexities of power system operations. In particular, a primary benefit of the EIM is a shorter dispatch interval; namely, 5 minutes. However, the model simulates the dispatch hourly. Therefore it cannot adequately measure the benefits of a more frequent dispatch. A tool with a finer time resolution would significantly improve simulation accuracy. When the study was conducted, the rules for the EIM were not clearly defined and it was appropriate to estimate societal benefits of the EIM assuming a perfect market without a detailed specification of the market design. However, incorporating a more complete description of market rules will allow for better estimates of EIM benefits. Furthermore, performing analyses using specific market rules can identify potential design flaws that may be difficult and expensive to correct after the market is established. Estimated cost savings from a more efficient dispatch are less than one percent of the total cost of electricity production.
Waste-to-energy (WTE) technologies present an opportunity to recycle organic waste material into renewable energy while offsetting disposal and environmental costs. A key challenge to ensuring economic and environmental viability of WTE is understanding the variability of individual WTE resource characteristics, including their location, amount, and quality. The main objective of this study is to estimate the wet WTE resource potential in the United States and illustrate its geographic distribution. The wet resources considered in this study are wastewater sludge, animal manure, food waste, and FOG (fats, oils, and greases). This study is the first to achieve results below national level, at the finest geographic resolution. Our analysis indicates that about 566 teragrams (Tg) of wet WTE resources are generated annually in the United States. This amount corresponds to about 1 exajoule (EJ), which is sufficient to displace about 18% of the 2015 U.S. on-highway diesel consumption on an energy basis. About half of this potential is generated by animal manure.
Increased contributions from wind and solar power resources are necessary to meet California’s goal to use 33 percent renewable energy by 2020. Using these renewable resources, however, will substantially increase the variability and uncertainty in electricity generation resources available to California’s electricity grid operators. Automated demand response and energy storage systems can help reduce this variability and uncertainty through energy buying and selling (arbitrage) in day-ahead markets that would levelize loads and prices throughout the day. They could also provide load-following capability through bids in the real-time market and system management (or regulation) services to the system operator. The project identified policies, technologies (energy storage), and control methods (demand response) that could reduce the cost and improve the reliability of electric power for California ratepayers. Data and assumptions describing energy storage and demand response resources were provided by the Electric Power Research Institute, the California Energy Storage Alliance, and the Demand Response Research Center. The California Independent System Operator provided the production simulation model and supporting data.
As inverter-based resources continue to be installed at all levels of the electric grid, the fixed protection schemes used at the distribution level will continue to be stressed until they no longer ensure the protection of the grid. Adaptive protection has been proposed as a solution with the ability to update the protection schemes in near real-time to ensure reliability and increase the resilience of the grid. However, weather variability poses a significant challenge to the ability of these methods to keep the selectivity and reliability of these schemes coordinated. If the ramp rates, due to solar variability, of the inverter-based resources change faster than the adaptive protection can issue new settings, the protection system could be uncoordinated, with the wrong device responding to a system fault. The proposed adaptive protection method ensures that due to solar variability, communication, and protection calculation latency, it can issu e coordinated protection settings promptly, in one minute or less. The hardware-in-the-loop results show the protection settings being issued and maintaining system coordination in under a minute.
The growing need for sustainable energy solutions in coastal areas necessitates the development of integrated systems that leverage abundant marine resources. In this study, a standalone Marine Energy Supported Multi-Energy System (MRE-MES) is designed for sustainable coastal community development, utilizing renewable marine resources, including offshore wind, wave, and solar energy, to address the energy needs of electricity, heat, freshwater, and hydrogen. The proposed MRE-MES incorporates a co-optimization model that simultaneously balances capacity planning and operational efficiency to minimize costs and environmental impacts. The system is tested under different renewable energy penetration levels and demand uncertainties, using a two-stage stochastic programming to account for variability in renewable resources and consumption needs. The experimental results indicate that in the optimal system capacity configuration, the percentage of total renewable energy generation is around 80 %, with or without capacity limitation constraints on PV, water tank, and hydrogen storage. Compared to the worst-case scenario in Monte Carlo experiments, two-stage stochastic optimization results in a more robust decision that effectively mitigates the risks posed by future uncertain demand conditions. In conclusion, the findings highlight the viability of marine energy for providing a resilient, comprehensive energy solution to coastal communities.
High-resolution, long-term solar dataset is essential for characterizing the variability of solar energy resources and for informing strategies that ensure grid reliability and resilience in grid systems with high levels of solar energy integration. We present the development of a new 4-km, hourly Earth system dataset for the contiguous United States (CONUS), using a statistical downscaling approach that integrates the National Solar Radiation Database (NSRDB) with regional Earth system model projections. The new high-resolution Earth system dataset includes key variables - GHI, DNI, DHI, surface air temperature, and wind speed - under two future scenarios. Preliminary results show a reasonable agreement with NSRDB observations, with nBias less than 1% for GHI across CONUS. The dataset is expected to support in-depth analyses of extreme weather impacts and provide input to resource adequacy for future energy systems with diverse generation sources.
As the penetration of variable generation (wind and solar) increases around the world, there is an accompanying growing interest and importance in accurately assessing the contribution that these resources can make toward planning reserve. This contribution, also known as the capacity credit or capacity value of the resource, is best quantified by using a probabilistic measure of overall resource adequacy. In recognizing the variable nature of these renewable resources, there has been interest in exploring the use of reliability metrics other than loss of load expectation. In this paper, we undertake some comparisons using data from the Western Electricity Coordinating Council in the western United States.
As power generation from variable distributed energy resources (DER) grows, energy flows in the network are changing, increasing the requirements for ancillary services, including voltage support. With the appropriate power converter, DER can provide ancillary services such as frequency control and voltage support. This paper outlines the economic potential of DERs coordinated in a microgrid to provide reactive power and voltage support at its point of common coupling. The DER Customer Adoption Model assesses the costs of providing reactive power, given local utility rules. Depending on the installed DER, the cost minimizing solution for supplying reactive power locally is chosen. Costs include the variable cost of the additional losses and the investment cost of appropriately over-sizing converters or purchasing capacitors. A case study of a large health care building in San Francisco is used to evaluate different revenue possibilities of creating an incentive for microgrids to provide reactive power.
Background/Objectives. The aggressive goals being set by nation states, communities, and private industry for decarbonization of grid electricity, industrial heat sources, and transportation around the world are imperative to mitigating the devastating effects that we are seeing from climate change. Although many of these goals focus on accomplishments by 2035 or 2050, the decisions that we make today won’t just impact the landscape of energy systems for the next 20 or 30 years—they will shape the world’s environment for centuries to come. That means that we can’t just focus on technologies that will get us to 2050, but technologies that will withstand our energy demands over that long-ranging future. Success will require us to utilize all of the clean energy resources that we have available to meet demands for electricity, heat, and steam, and we will need energy carriers such as hydrogen that do not emit additional greenhouse gases at the point of use. Nuclear energy, ranging from technologies in service today to advanced, higher temperature and modular systems that will be in service this decade, will provide a robust complement to renewable energy resources that operate variably. Researchers across the U.S. Department of Energy laboratory complex are working to advance multiple aspects of these clean energy solutions, with many focusing on integrated energy system solutions that leverage all available clean energy assets to meet wide-ranging energy demands. Approach/Activities. Nuclear energy is a proven, zero-emission option during operation that can provide consistent, dispatchable power to meet electricity demands while also providing high-quality heat that can meet energy demands beyond the electricity sector. Energy system design should seek to maximize these assets. As a dispatchable energy source with a small land utilization footprint, nuclear energy can be collocated with renewable resources, and the smaller systems that will be deployed this decade (ranging from a few megawatts to hundreds of megawatts) can be installed right where that energy is needed. Integrated nuclear and renewable systems will enhance power grid reliability and resilience, and they will help stabilize the grid through their increasingly flexible operation. Licensing, installation, and broad adoption of these advanced nuclear energy systems are expected to progress significantly in the 2020s, but this may be longer than desired by some stakeholders wishing to implement impactful clean energy decisions today. However, one must recall that nuclear energy systems will operate for 80 or more years, as is being demonstrated by current fleet nuclear systems. The nuclear community is extremely thorough in reviewing these systems with regard to safety and security; these efforts ensure that the deployed systems will continue to provide reliable, resilient energy over that operational lifetime. That investment of time up front will ensure that we can support energy demands over the centuries to come. While advanced nuclear technologies move through this process, communities and private industry may choose to install renewable generation systems that can later be coupled to the complementary nuclear systems as they become available—thus moving closer to the net zero goals in the near term. Choosing technologies and deployment configurations that allow small modular nuclear powerhouses to be added to these “energy parks” as they become available will ensure that advanced technologies can be readily adopted to support growing demands for clean energy. Results/Lessons Learned. The primary focus of integrated energy systems (IES) research is to assess the technical and economic potential of novel multi-input, multioutput solutions that are expected to enhance energy system flexibility, reliability, and resilience as we pursue a clean energy transition. Various energy applications and product streams beyond electricity are being evaluated, ranging from generation of potable water to production of hydrogen, fertilizers, synthetic fuels, and various chemicals. In early FY23 Idaho National Laboratory (INL) will commission thermal energy generation systems that emulate nuclear fission energy input using electric heating and will allow for integrated system testing with thermal energy storage, hydrogen production via high temperature electrolysis (HTE), and power systems hardware to demonstrate operation of a clean energy park within a microgrid or larger grid infrastructure, supporting up to 450 kW of heat input via electric heating and demonstrating operation of HTE systems at the multi-hundred kW scale. This presentation will highlight the wide array of RD&D being conducted at INL and partner laboratories to develop and deploy nuclear and renewable-based IES that will be key to achieving our net zero goals, including both computational and experimental demonstrations. By working with key collaborators in industry, analytical st
In developing a national energy strategy, the United States has a number of objectives, including increasing economic growth, improving environmental quality, and enhancing national energy security. Wind power contributes to these objectives through the deployment of clean, affordable and reliable domestic energy. To achieve U.S. wind generation objectives, the Wind and Water Power Program within the Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy (EERE) instituted the U.S. Offshore Wind: Removing Market Barriers Program in FY 2011. Accurate and comprehensive information on offshore wind resource characteristics across a range of spatial and temporal scales is one market barrier that needs to be addressed through advanced research in remote sensing technologies. There is a pressing need for reliable offshore wind-speed measurements to assess the availability of the potential wind energy resource in terms of power production and to identify any frequently occurring spatial variability in the offshore wind resource that may impact the operational reliability and lifetime of wind turbines and their components and to provide a verification program to validate the “bankability” of the output of these alternative technologies for use by finance institutions for the financing of offshore wind farm construction. The application of emerging remote sensing technologies is viewed as a means to cost-effectively meet the data needs of the offshore wind industry. In particular, scanning and buoy mounted LIDAR have been proposed as a means to obtain accurate offshore wind data at multiple locations without the high cost and regulatory hurdles associated with the construction of offshore meteorological towers. However; before these remote sensing technologies can be accepted the validity of the measured data must be evaluated to ensure their accuracy. The proposed research will establish a unique coastal ocean test-bed in the Mid-Atlantic for the evaluation of LIDAR-based wind measurement systems to validate the accuracy of remotely measured wind data in marine applications. Specifically, the test-bed will be utilized to systematically evaluate the capability of emerging scanning LIDAR and buoy mounted vertically profiling LIDAR by: (1) Evaluating a fixed scanning LIDAR against land-based 50 and 60 meter high meteorological masts fitted with research quality cup-vane and/or sonic anemometers; (2) Evaluating a buoy mounted vertically profiling LIDAR fixed on land and floating in a sheltered bay against a co-located 60 meter high meteorological mast fitted with a research quality cup-vane and/or sonic anemometers and the fixed scanning LIDAR; and (3) Offshore field evaluation of both LIDAR platforms through a comparison of the fixed scanning LIDAR data and data obtained by the buoy mounted LIDAR located 10 miles offshore. The proposed research will systematically validate Light Detection and Ranging (LIDAR) based wind measurement systems and assess the temporal and spatial variability of the offshore wind resource in the Mid-Atlantic east of New Jersey. The goal of the proposed project is to address the technical and commercial challenges of the offshore wind energy industry by validating and assessing cost-effective, over ocean wind resource characterization technologies. The objective is to systematically evaluate the capability of both scanning and vertically profiling LIDARs to accurately measure 3D wind fields through comparison with fixed met masts and intercomparison among LIDAR platforms. Once validated, data collected by both buoy mounted vertically profiling LIDARs and shore-based, pulsed horizontally scanning LIDARs can be used to accurately assess offshore wind resources and to quantify the spatial and temporal variability in the offshore wind fields. One of the fundamental research questions to be addressed in phase 1 is the assessment of various measurement and data processing schemes to retrieve accurate wind vectors in the marine environment over large sampling ranges (10 to 12 km) and varying atmospheric aerosol levels. Atmospheric conditions and aerosol content within the coastal ocean region of the Mid-Atlantic seaboard of the US can vary significantly over short time periods in response to frontal passages and extratropical and tropical low pressure system passage offshore of the coast. Since aerosols provide the scattering medium for the determination of LIDAR Doppler shifts in the atmosphere the accuracy and range of LIDAR derived velocity measurements as a function of variation in aerosol content in the marine environment is a key research question to be addressed. In phase 1, it is desired to capture as much variation in atmospheric conditions and aerosol content as possible. To this end, collocated measurements of LIDAR and standard anemometer wind fields will be captured by the project PIs over all four seasons and during specific events (e.g., coastal low pressure system passage) in year 1. Additionally, since the meteorological masts are permanent structures, additional events can be captured over the three year duration of the field research project. All research instruments are owned by Fishermen’s Energy and made available to the PIs though a lease agreement as part of the DOE grant. Energy Fishermen’s Energy will be responsible for the operation and maintenance of the scanning LIDAR and met mast anemometers. On a daily basis, environmental data and systems performance indicators will be transmitted from each measurement station to the Fishermen’s project team consisting of both in-house personnel and equipment manufacturer engineers. Data sets include compiled LIDAR files as well as data sets from ancillary sensors. Diagnostic parameters to be monitored include standard deviations of measured values, battery levels and charging systems output, and the operational status. Once data have been confirmed as complete and reliable, files will be transferred to the Garrad Hassan (a subcontractor to Fishermen’s Energy) for incorporation in to the validation database, which is accessible to other scientific team members. Data collection times and durations will be determined by the PI and Co-PIs in consultation with instrument engineers to ensure the capture of data representative of the expected range of mid-Atlantic atmospheric conditions (e.g., temperature, moisture, coastal low pressure systems, tropical systems, rain, snow, fog). The collection and processing of the data is a function of site specific measurement requirements (Kelley et.al. 2007; Hannon et.al. 2008). To determine the optimal profiles of wind speed and direction from the LIDAR radial velocities as a function of azimuth angle, rigorous estimates of the bias and random error of each radial velocity estimate are required. Lockheed Martin Coherent Technologies, Inc., under contract with Fishermen’s Energy, will provide analyses of raw and processed data using various scan patterns to determine optimal performance settings for the pulsed scanning LIDAR. Once optimized, appropriate processing and analyses techniques will be evaluated by Garrad Hassan for use in validating the accuracy of the LIDAR wind field measurements against the standard anemometer measurements from the meteorological masts. The most attractive capability of the scanning LIDAR is the ability to provide high spatial resolution observations in a three-dimensional volume which provides superior statistical accuracy due to the large number of samples obtained. Each radial scan provides measurements in 100 range gates over a distance of 10 to 12 km at an update rate of 5 to 10 Hz and rotation of 2.5° per second. Each rotation at a fixed azimuth requires 2.4 minutes. Depending on the number of azimuths desired a complete scan can take up to 10 minutes or longer to complete. Once collected the radial velocities are processed to produce vector wind velocity estimates based on a set of data distributed in angle and range around points of interest, typically a standard grid within the radial wind map. To calculate wind vectors over a limited spatial area of interest for the comparison of data with other measurement platforms a localized least-squares approach has been applied by Hannon et.al. (2008) and a Variation Assimilation (VAR) processing technique has been applied by Chan and al Assimilation (VAR) processing technique has been applied by Chan and Shao (2006). Additionally, Kelley et.al. (2007) applied a “stare” technique that fixed a scanning LIDAR in both azimuth and elevation angles to measure over collocated sampling volumes of the LIDAR and a 3D sonic anemometer mounted to a fixed mast. Although the stare technique is limited to wind directions aligned with the sampling radial of the LIDAR, it does provide a direct comparison of sampling volumes. Each of the processing techniques described above (and possibly others) will be evaluated to determine the validity of the LIDAR derived wind fields in the marine environment. Numerical methods such as linear regression and comparison of probability density functions of wind fields measured by each instrument platform will be used to assess the processing techniques. Linear regression has the advantage of directly evaluating corresponding pairs of wind data measured by each instrument and can lend insight into deviations and bias between instruments as a function of wind speed. Assessment of the coherency between the probability density function of the wind measured by each instrument provides insight into processes that may not be accurately resolved by each instrument at specific frequencies. Once processed and assessed the most appropriate technique will be utilized to provide valid wind measurements from the pulsed scanning LIDAR. A detailed analysis of the measurement data from the LIDAR and the three meteorological towers and comparison of the coastal wind characteristics from the different systems will be performed by the CO_PI at NREL. This analysis will evaluate how the WT LIDAR performance and measurement of the wind characteristics vary with distance from the LIDAR and by atmospheric conditions; using the tower measurements at different distances (4.8, 9.6, and 19 km) from the LIDAR as a reference. The comparative analysis will include, to the extent possible, evaluation of parameters such as wind speed and direction distributions, wind shear, turbulence intensity and their variations by atmospheric conditions, month or season, and time of day.
The capacity credit for a generator is the fraction of its nameplate capacity that can contribute to meeting the system's resource adequacy. However, estimating the capacity credit of variable renewable energy is challenging due to the variability, uncertainty, and spatial diversity of the renewable resources. This study uses the Regional Energy Deployment System to quantify the impacts on the U.S. power sector through 2050 from misestimations of renewable capacity credit. Results show that small underestimates of the renewable capacity credit have little impact on system buildout, but that large underestimates (>50%) can reduce solar photovoltaic deployment by nearly 100 GW (50%) and wind by up to 43 GW (22.8%) in 2030s. Such large differences are possible because the capacity credit for variable renewable energy can substantially impact the overall costs and value of variable renewable energy relative to other technologies. Such effects are most strongly felt in the mid-term but are less relevant over the long-term due to the declining value of variable resources. Underestimating the capacity credit of variable renewable energy leads to increased system costs and emissions. Conversely, overvaluing the capacity credit of variable renewable energy reduces system costs at the risk of lower reliability.
Pumped storage hydropower (PSH) is a type of hydropower technology where energy can be stored and generated by moving water between two reservoirs of differing elevations. In addition to providing 97% of the total utility-scale hydropower storage in the United States, PSH plants have operational characteristics - such as high ramp rates and the ability to provide reserves - that contribute to greater flexibility and reliability of the power grid. New PSH technologies can provide additional flexibility beyond existing, fixed-speed units. With the emergence of high levels of variable renewable energy resources (e.g., wind and solar), energy storage is expected to be crucial to the reliability and reliance of the power grid in a low-carbon future. At diurnal and longer durations, PSH plants have some of the lowest costs per unit of energy, have been proven to be reliable and efficient, are not cycle-limited, and typically have long lives, often exceeding 50 years. The work presented here focuses on a new generation of PSH: ternary PSH and quaternary PSH (together referred to as T/Q-PSH). Given recent experience in Europe, grid operators in the United States and elsewhere are increasingly focusing their attention on T/Q-PSH as a proven, financeable technology that can offer utility-scale, long-duration, fast-acting energy storage capabilities and grid services. T/Q-PSH differs from conventional PSH in that it can provide fast-response ancillary services during both generating and pumping operations. This capability together with fast mode switching times are key attributes that make T/Q-PSH technologies attractive for managing and stabilizing electricity systems with high amounts of variable renewable energy.
Not Available
Not Available
In this work, the integrated design and dispatch of behind-the-meter or distributed resources (e.g. stationary battery storage and solar PV generation) is considered. A simulation-based framework is employed, generating high-fidelity results with closed-loop predictive control at a fine resolution, at the expense of high computational cost (several minutes to a few hours per design point). To address this challenge, parallel derivative-free design methods are considered. Four methods are compared, including state-of-the-art surrogate-based methods (Radial-Basis Functions and Gaussian processes) and sampling strategies, an evolutionary-based method, and a simple sequential grid refinement method. As a case study, two types of design problem with increasing complexity are considered, namely, the design of behind-the-meter resources (three design variables) and the inclusion of grid capacity (four design variables). The second yields a constrained design problem for which violations can only be determined after solving the computationally expensive simulation. For the three-dimensional case, all methods present a good performance, achieving a solution within 1% of the optimum after the first iteration, with the sequential grid refinement exhibiting the fastest convergence and achieving the best final objective value. This indicates that the parallel evaluation of multiple sampling points may be more important than the choice of method for small decision spaces. For the four-dimensional constrained case, the Genetic Algorithm presents the best tradeoff between performance and computational effort, while the rough objective function terrain generated by constraint violation penalties reduces the performance of surrogate-based methods. Contour plots with flat regions indicate flexibility in the optimal design and highlight the importance of characterizing the solution space.
This study examines the impact of reserve margin-based reliability assessment, as commonly used in capacity expansion models, on planning resource-adequate power systems under high penetrations of solar photovoltaics (PV). As a generation resource, PV is operationally different from the conventional dispatchable resources for which most capacity expansion models were designed. The question this study attempts to answer is whether large amounts of PV on a system (in this case, the Western Interconnection of North America) would bias the results of conventional reserve margin-based capacity expansion modeling towards an over- or under-provisioning of resource adequacy. This analysis used NREL’s Resource Planning Model (RPM) for capacity expansion modeling and NREL’s Probabilistic Resource Adequacy Suite (PRAS) for resource adequacy assessment. RPM uses a reserve margin requirement to enforce resource adequacy. PRAS, a collection of tools for studying the resource adequacy of power systems and the adequacy contributions of individual resources on a probabilistic basis, was used to compute multiple resource adequacy metrics across a number of simulated scenarios and system representations with differing regional detail. In all cases, including high PV penetrations (up to 33% annual generation from PV, interconnection-wide), RPM was able to produce resource-adequate systems as measured by normalized expected unserved energy and loss-of-load expectation results from PRAS. The accuracy of reserve margin approaches depends heavily on the underlying assumptions informing the capacity credit assigned to variable and energy-limited resources, particularly when such resources are abundant in the modeled system. RPM’s standard methodology for estimating variable and flexible resources’ capacity contributions, which is based on the top 100 hours of net load, did not appear to systematically undervalue or overvalue variable generation relative to a more rigorous equivalent firm capacity assessment using PRAS, although both over- and under-valuations were observed in specific scenarios. In the worst cases, the top 100 hour method underestimated the equivalent firm capacity of PV by two percentage points, and overestimated the equivalent firm capacity of PV by five percentage points. Calculating capacity contributions based on the top 10 hours of net load systematically underestimated equivalent firm capacities at more modest PV penetrations, but was often a better approximation of equivalent firm capacity than the existing 100-hour approach in scenarios with higher PV penetrations.
Building demand flexibility (DF) research has recently gained attention. To unlock building DF as a predictable grid resource, we must establish a quantitative understanding of the resource size, performance variability, and predictability based on large empirical datasets. Researchers have proposed various sets of theoretical metrics to measure this performance. Some metrics have been applied to simulation results, but most fall short of exploring the complexities in real building applications. There are practical metrics used in individual demand response field studies but they alone cannot fulfil the job of DF benchmarking across a diverse group of buildings. The electrical grid's geographically diverse and changing nature presents challenges to comparing building DF performance measured under different conditions (i.e., benchmarking DF). To address this challenge, a novel DF benchmarking framework focused on load shedding and shifting is presented; the foundation is a set of simple, proven single-event metrics with attributes describing event conditions. These enable benchmarking and visualization in different dimensions for identifying trends that represent how these attributes influence DF. To test its feasibility and scalability, the DF framework was applied to two case studies of 11 office buildings and 121 big-box retail buildings with demand response participation data. Furthermore, these examples provided a pathway for using both building level benchmarking and aggregation to extract insights into building DF about magnitude, consistency, and influential factors. Potential applications of the framework and real-world values have been identified for grid and building stakeholders.