Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage loss analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Gateway Power Quality Lessons Learned

Power Quality is a physical description of the electrical characteristics that allow the system to function properly without significant loss of performance or life. This physical description includes steady state voltage limits, transient voltage limits in normal/abnormal conditions, ripple voltage, stability, fault conditions, and more. All which are vital for improving reliability, ensuring stable operation, defining proper fault recovery, and ensuring a ‘plug and play’ approach to design and integration. Typically, a specification for Power Quality is created based on expected system performance or an existing standard, such as the International Space Power System Interoperability Standards (ISPSIS). One example of such a specification is the Gateway Power Quality Specification. It defines the requirements and characteristics of the 120 Volt direct current electrical power system for the Gateway Electrical Power System (EPS) and the Gateway Electrical Power Consuming Equipment (EPCE). This specification also maintains a separate requirement verification section that defines test methods for requirement verification. The test methods include analysis, test, inspection, and demonstration. These test methodologies and requirements are used to ensure that the loads operate when connected to the specified power quality and performance as defined by this specification. The challenge with developing a specification is that desired system characteristics are not always fully matured before the specification is needed and many performance requirements may be application specific. This drives the need to utilize lessons learned through extensive analysis and testing as well as historical knowledge to finalize requirements. Some example requirements where this is important are Small and Large Signal Stability, Ripple Voltage, Inrush/Surge Currents, and Fault Containment. Lessons learned are also important in the testing, analysis, and verification to ensure consistent and accurate results to verify performance. This presentation will cover the lessons learned for power quality relative to ripple, inrush/surge, fault containment, testing/verification, and more.

Power Quality↗

A Single-Stage Isolated Resonant SiC DC/AC Inverter for Efficient High-Power Applications

This paper presents a single-stage series-resonant dual active half bridge (SR-DAHB) inverter suitable for high power applications. The topology is an isolated dual half-bridge circuit with an unfolding bridge. A combined phase-shift and frequency modulation technique is utilized to generate AC power output. In high-power applications where the switching devices operate at relatively high current and voltage, the switching loss becomes the major portion of the converter’s total loss as the devices are turned on and off under hard switching condition. The primary merit of the proposed single-stage SR-DAHB inverter with the combined phase-shift and frequency modulation control is to significantly reduce the switching loss so that it is not a function of load current. A precise and comprehensive power loss model is developed for both the SR-DAHB and DAHB to optimize the operation of the inverters. The objective of the optimization is to minimize the inverter total loss while calculating the optimum combination of frequency and phase shift. A 1.5 kV, 50 kW prototype was built to demonstrate the performance of the SRDAHB versus DAHB inverters with the combined phase-shift and frequency modulation control, and validate the theoretical analysis.

Tayebi, S. Milad↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Stability Analysis of Control System in Multiport Autonomous Reconfigurable Solar Power Plants (MARS)

The Multiport Autonomous Reconfigurable Solar Power Plant (MARS) is an integrated photovoltaic (PV) power generation and energy storage system (ESS), that is designed to connect to both alternating current (AC) transmission grids and high-voltage direct current (HVDC) links. It is a three-phase plant consisting of numerous components with a complex hardware and hierarchical control architecture. This paper presents an approach to decouple the multivariable system of MARS using a recursive reduced-order and boundary layer system methodology. This approach enables efficient computation of the control parameters for the Ll, L2, and L3 controllers. To validate the effectiveness of the proposed control strategy, cyclic tests in accordance with pre-defined performance criteria using controller Hardware-in-the-Loop (cHIL) experiments are conducted. The results demonstrate that the MARS system operates consistently under steady-state conditions. Furthermore, the dynamic response of the MARS system to various grid events is analyzed, underlining the resilience of MARS in presence of faults or loss of generation within the connected WECC system.

Xia, Qian↗

An overview of vertebrate mineralization with emphasis on collagen-mineral interaction

The nucleation, growth, and development of mineral crystals through their interaction principally with collagen in normal bone and calcifying tendon have been elaborated by applying a number of different techniques for analysis of the inorganic and organic constituents of these tissues. The methods have included conventional and high voltage electron microscopy, electron diffraction, microscopic tomography and 3D image reconstruction, and atomic force microscopy. This summary presents results of these studies that have now characterized the size, shape, and aspects of the chemical nature of the crystals as well as their orientation, alignment, location, and distribution with respect to collagen. These data have provided the means for understanding more completely the formation and strength of the collagen-mineral composite present in most vertebrate calcifying tissues and, from that information, a basis for the adaptation of such tissues under mechanical constraints. In the context of the latter point, other data are given showing effects on collagen in bone cell cultures subjected to the unloading parameters of spaceflight. Implications of these results may be particularly relevant to explaining loss of bone by humans and other vertebrate animals during missions in space, during situations of extended fracture healing, long-term bedrest, physical immobilization, and related conditions. In a broader sense, the data speak to the response of bone and mineralized vertebrate tissues to changes in gravitational loading and applied mechanical forces in general.

Non-NASA Center↗

Anodic Interfacial Evolution in Extremely Fast Charged Lithium-Ion Batteries

Interfacial reaction mechanisms at the anode/separator interface play a central role in the performance and safety of lithium-ion batteries during fast charging. We report a mechanistic study on the evolution and interactions of the aging mechanisms at the anode/separator interface in lithium cobalt oxide/graphite pouch cells charged with variable charging rates (1–6C) over 10 cycles. In situ electrochemical measurements, including voltage relaxation, Coulombic efficiency, and direct current internal resistance, indicated an incremental lithium loss until the C rates were ≤5C. A substantial capacity fade is observed in the first few cycles of fast charging, but the magnitude of capacity fade progressively diminishes with the number of cycles, indicating a suppression in the lithium deposition mechanism. Post-mortem film thickness, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM) analyses were performed to elucidate the evolution of electrolyte decomposition, the solid–electrolyte interface (SEI), lithium plating, and film fracture mechanisms with C rate. XPS measurements confirmed an increasing lithium concentration in an SEI film with an increase in the C rate. SEM images showed a growth of dendritic lithium on the anode surface from 1C to 3C. Precrack formation leading to an interfacial film fracture was observed at higher C rates. Furthermore, a differential analysis of the discharge capacity indicated a possible two-phase delithiation from the anode and reduced cathodic lithiation due to lithium loss at high C rates.

36 MATERIALS SCIENCE↗

Multilayer Piezoelectric Stack Actuator Characterization

Future NASA missions are increasingly seeking to use actuators for precision positioning to accuracies of the order of fractions of a nanometer. For this purpose, multilayer piezoelectric stacks are being considered as actuators for driving these precision mechanisms. In this study, sets of commercial PZT stacks were tested in various AC and DC conditions at both nominal and extreme temperatures and voltages. AC signal testing included impedance, capacitance and dielectric loss factor of each actuator as a function of the small-signal driving sinusoidal frequency, and the ambient temperature. DC signal testing includes leakage current and displacement as a function of the applied DC voltage. The applied DC voltage was increased to over eight times the manufacturers' specifications to investigate the correlation between leakage current and breakdown voltage. Resonance characterization as a function of temperature was done over a temperature range of -180C to +200C which generally exceeded the manufacturers' specifications. In order to study the lifetime performance of these stacks, five actuators from one manufacturer were driven by a 60volt, 2 kHz sine-wave for ten billion cycles. The tests were performed using a Lab-View controlled automated data acquisition system that monitored the waveform of the stack electrical current and voltage. The measurements included the displacement, impedance, capacitance and leakage current and the analysis of the experimental results will be presented.

active mirrors↗

A three-dimensional pore-scale model for redox flow battery electrode design analysis

A three-dimensional (3-D) pore-scale model has been developed to construct multiscale fibrous electrodes for redox flow batteries (RFB). New designs, such as biporous electrodes modify electrode structures by creating secondary pores on single carbon fiber to reduce internal battery resistance. Existing pore-scale models only resolve electrodes to the single carbon fiber scale and cannot incorporate recent multiscale electrode designs into numerical models. Our new model aims to bridge this gap and provide a tool to rapidly screen new electrode configurations. Two multiscale electrodes, laser-perforated and biporous electrodes, were investigated at varying operation conditions with the proposed 3-D pore-scale models. The laser-perforated electrode exhibits a reduced pressure drop, but follows the same permeability correlation compared to the corresponding pristine electrode. For the biporous electrode, the added specific surface area and faster reaction kinetics from the secondary pores are the most influential factors leading to improved battery efficiency. However, operating the biporous electrode in limiting current density conditions should be avoided due to the decreased mass transfer efficiency and a more significant voltage loss. Finally, we believe that our 3-D pore-scale model can accelerate the flow battery electrode design process and provide new insights into electrode geometry optimizations.

25 ENERGY STORAGE↗

Phosphorus replenishment to improve the contact resistivity of light-induced Al contacts on Si solar cells

A method to repair laser-induced phosphorus loss from the n-type emitter of Si solar cells during light-induced Al plating is demonstrated. The ability to add a water-reactive phosphorus compound, PCl 5 , into the Al plating bath gives a unique advantage to Al over Cu for front contacts on Si solar cells. The contact resistivity between light-induced Al and Si emitter is reduced to as low as 0.1 mΩ-cm 2 . Cyclic voltammetry performed on a plating bath composed of 81 wt% 1-ethyl-3-methylimidazolium tetrachloroaluminate, 19 wt% AlCl 3 , and 0.2 wt% PCl 5 reveals multiple reduction reactions of PCl 5 , although incomplete decomposition of PCl 5 is possible. A decrease in nucleation loop size during cyclic voltammetry is also observed suggesting that PCl 5 , while being consumed, modifies the growth mechanism during Al plating. Structural analysis confirms that the addition of PCl 5 produces an Al film which is levelized and compact. Here, a pulsed voltage profile coupled with chemical analysis verifies that phosphorus incorporation is electrolytically activated and is likely the cause for the low contact resistivity.

14 SOLAR ENERGY↗

Analysis of Thermoradiative Thermal Energy Conversion

The thermoradiative cell is a new method for converting heat energy to electrical power, first detailed by Strandberg in 2015. The cell is a p-n junction semiconductor device, similar to a photovoltaic cell but thermodynamically operating in the reverse direction, converting the thermal dark current into electrical power while radiating waste heat to space. The power and efficiency can be calculated as a function of bandgap in the Shockley-Queisser detailed-balance limit, in which the thermal emissivity of the cell is due to the recombination of electron-hole pairs, and all other recombination losses are ignored. The current produced is directly proportional to the recombination radiation. The fundamental loss mechanism for the thermoradiative cell is the energy carried by the infrared radiation into space from band-to-band recombination of carriers injected across the junction. In an ideal cell, to maximize the efficiency, the emission energy of these photons would precisely equal the bandgap. This can be achieved, for example, using dielectric filters or meta-material filters to recycle emission at other wavelengths back into the cell. The voltage is proportional to the external bias. These two constraints allow optimization of the optimum bias point for maximum power. Unlike photovoltaic cells, the maximum power operating point is not the same as the maximum efficiency point, and higher efficiency can be achieved at a higher (negative) bias in the ideal case. Incorporating non-ideal losses, however, shifts the maximum efficiency point toward lower bias. Unlike in photovoltaic cells, non-radiative recombination (e.g., Auger losses) will reduce the output current, but will not reduce the conversion efficiency, since the recombination energy is retained in the cell in the form of heat. Since a thermoradiative cell operates by radiating directly to space, the current produced by themoradiative cells will increase as Stefan-Boltzmann radiation; roughly the fourth power of the temperature. Thus, the power produced is highest at high operating temperatures, and, unlike conventional thermal conversion, increasing radiator temperature increases, the efficiency. Thus, the choice of technology will be toward semiconductors resistant to degradation at high temperature.

Thermoradiative↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge and Neutralizer Cathodes

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for both discharge and neutralizer cathodes. Discharge keeper erosion was found to be significantly reduced from what was observed in the NEXT 2 kh wear test and NSTAR Extended Life Test, providing adequate protection of vital cathode components throughout the test with ample lifetime remaining. The area of the discharge cathode orifice plate that was exposed by the keeper orifice exhibited net erosion, leading to cathode plate material building up in the cathode-keeper gap and causing a thermally-induced electrical short observed during the test. Significant erosion of the neutralizer cathode orifice was also found and is believed to be the root cause of an observed loss in flow margin. Deposition within the neutralizer keeper orifice as well as on the downstream surface was thicker than expected, potentially resulting in a facility-induced impact on the measured flow margin from plume mode. Neutralizer keeper wall erosion on the beam side was found to be significantly lower compared to the NEXT 2 kh wear test, likely due to the reduction in beam extraction diameter of the ion optics that resulted in decreased ion impingement. Results from the post-test inspection have led to some minor thruster design improvements.

Electric Propulsion↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge and Neutralizer Cathodes

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 h of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for both discharge and neutralizer cathodes. Discharge keeper erosion was found to be significantly reduced from what was observed in the NEXT 2 kh wear test and NSTAR Extended Life Test, providing adequate protection of vital cathode components throughout the test with ample lifetime remaining. The area of the discharge cathode orifice plate that was exposed by the keeper orifice exhibited net erosion, leading to cathode plate material building up in the cathode-keeper gap and causing a thermally-induced electrical short observed during the test. Significant erosion of the neutralizer cathode orifice was also found and is believed to be the root cause of an observed loss in flow margin. Deposition within the neutralizer keeper orifice as well as on the downstream surface was thicker than expected, potentially resulting in a facility-induced impact on the measured flow margin from plume mode. Neutralizer keeper wall erosion on the beam side was found to be significantly lower compared to the NEXT 2 kh wear test, likely due to the reduction in beam extraction diameter of the ion optics that resulted in decreased ion impingement. Results from the post-test inspection have led to some minor thruster design improvements.

Ion engine↗

Comprehensive Comparative Analysis: VSI-based vs. CSI-based Motor Drive Systems with Sinusoidal Output Voltage

The emergence of wide-bandgap (WBG) power devices opens opportunities for current source inverters (CSIs) to provide a promising alternative drive configuration for motor drive applications. The sinusoidal output voltage of CSI offers significant advantages for numerous motor drive applications, including reducing the risks associated with motor terminal overvoltages and bearing discharge currents. This paper compares the performance of CSIs and voltage source inverters (VSIs) with the same performance capabilities. More specifically, sine filters are added to the VSI output terminals to match the CSI performance, and a front-end boost converter is added to the VSI to match the CSI’s voltage-boost capability. The results show that the CSI active components require 48% less volume than the VSI, combined with other performance advantages that make it an appealing candidate for some future motor drive applications.

current source inverter, motor drive system, passi↗

Development of a Linear Stirling Model with Varying Heat Inputs

The linear model of the Stirling system developed by NASA Glenn Research Center (GRC) has been extended to include a user-specified heat input. Previously developed linear models were limited to the Stirling convertor and electrical load. They represented the thermodynamic cycle with pressure factors that remained constant. The numerical values of the pressure factors were generated by linearizing GRC s non-linear System Dynamic Model (SDM) of the convertor at a chosen operating point. The pressure factors were fixed for that operating point, thus, the model lost accuracy if a transition to a different operating point were simulated. Although the previous linear model was used in developing controllers that manipulated current, voltage, and piston position, it could not be used in the development of control algorithms that regulated hot-end temperature. This basic model was extended to include the thermal dynamics associated with a hot-end temperature that varies over time in response to external changes as well as to changes in the Stirling cycle. The linear model described herein includes not only dynamics of the piston, displacer, gas, and electrical circuit, but also the transient effects of the heater head thermal inertia. The linear version algebraically couples two separate linear dynamic models, one model of the Stirling convertor and one model of the thermal system, through the pressure factors. The thermal system model includes heat flow of heat transfer fluid, insulation loss, and temperature drops from the heat source to the Stirling convertor expansion space. The linear model was compared to a nonlinear model, and performance was very similar. The resulting linear model can be implemented in a variety of computing environments, and is suitable for analysis with classical and state space controls analysis techniques.

Regan, Timothy F.↗

Development of a Linear Stirling System Model with Varying Heat Inputs

The linear model of the Stirling system developed by NASA Glenn Research Center (GRC) has been extended to include a user-specified heat input. Previously developed linear models were limited to the Stirling convertor and electrical load. They represented the thermodynamic cycle with pressure factors that remained constant. The numerical values of the pressure factors were generated by linearizing GRC's nonlinear System Dynamic Model (SDM) of the convertor at a chosen operating point. The pressure factors were fixed for that operating point, thus, the model lost accuracy if a transition to a different operating point were simulated. Although the previous linear model was used in developing controllers that manipulated current, voltage, and piston position, it could not be used in the development of control algorithms that regulated hot-end temperature. This basic model was extended to include the thermal dynamics associated with a hot-end temperature that varies over time in response to external changes as well as to changes in the Stirling cycle. The linear model described herein includes not only dynamics of the piston, displacer, gas, and electrical circuit, but also the transient effects of the heater head thermal inertia. The linear version algebraically couples two separate linear dynamic models, one model of the Stirling convertor and one model of the thermal system, through the pressure factors. The thermal system model includes heat flow of heat transfer fluid, insulation loss, and temperature drops from the heat source to the Stirling convertor expansion space. The linear model was compared to a nonlinear model, and performance was very similar. The resulting linear model can be implemented in a variety of computing environments, and is suitable for analysis with classical and state space controls analysis techniques.

Regan, Timothy F.↗

Physical Interpretation of Early Battery Life Prediction Models

Early battery life prediction models are most useful for R&D if they help us understand the early changes in battery electrochemical response that correspond with long-term degradation and failure. Linear regression models such as Fused lasso and Partial Least Squares can fit coefficients directly to high-dimensional electrochemical data like capacity-voltage and ΔV–state-of-charge, i.e., Q(V) and ΔV(SOC) curves, learning coefficients that can be physically interpreted. We leverage the ISU-ILCC battery aging data set to learn high-dimensional coefficients for early battery life prediction from traditional slow-rate capacity check data, demonstrating learning on Q(V), d Q· d V −1 , and ΔV(SOC) curves. A thorough study on the dependence of coefficient values on train/test size and data preprocessing methods is made, demonstrating the reliability of high-dimensional regression approaches unless very small amounts of data are used for model training. For this data set, coefficients from Q(V) and d Q· d V −1 models highlight changes in electrode stoichiometry due to lithium loss, while ΔV(SOC) coefficients highlight changes in positive electrode diffusivity due to particle cracking as well as electrode stoichiometry shifts. By directly interpreting the coefficients of a regression model, we make physical insights into battery degradation mechanisms without requiring the assumptions of traditional battery data analysis methods.

25 ENERGY STORAGE↗

Degradation mechanisms and partial shading of glass-backsheet and double-glass photovoltaic modules in three climate zones determined by remote monitoring of time-series current–voltage and power datastreams

Degradation and partial shading impact the long-term reliability and power production of photovoltaic (PV) modules and power plants. Time-series power (P mp ) and current–voltage (I-V) curve datastreams from PV modules enable a remote diagnostic approach to quantify active degradation mechanisms and identify partial shading. We study three to nine years of these datastreams, including 3.6 million P mp I-V curves and 36 million values, from eight PV modules, four each of double-glass and glass-backsheet module architectures, located in three distinctly different Köppen-Geiger climate zones, to determine the module’s performance loss rates (PLR), identify active degradation mechanisms and power loss modes, along with partial shading by local objects. Considering both module architectures, PLR results indicate that the BSh climate zone is the most aggressive for module degradation, while the Alpine ET zone is the mildest climate. PLR of double-glass modules located in BWh and BSh climate zones are different due to the significantly greater uniform current loss (ΔP Isc ) for double-glass modules in BSh, at a 5% significance level. Power loss for four out of five modules located in the BWh and BSh climates are dominated by uniform current degradation. Statistical analysis of multistep I-V curves detects partial shading experienced by three studied modules with details of the shading profile, the shading Poynting vector diagram for the obstacle’s relative position, shading scenarios, and duration. Lastly, this work demonstrates how remote monitoring and diagnosis of P mp & I-V time-series of modules can provide quantitative operations and maintenance insights into system performance, degradation mechanisms, and shading.

14 SOLAR ENERGY↗

A Call To Action To Engage The Community To Meet The Challenges That Must Be Tackled To Make Electrified Aircraft Propulsion Real

Technology risk reduction is essential, as it is necessary to demonstrate the potential of Electrified Aircraft Propulsion (EAP). However, more is needed for implementation. The industry is leading EAP by developing a diverse community of novel vehicles from short-haul, small, urban-focused electric vertical takeoff and landing (eVTOL) to regional air mobility (RAM) and hybrid-electric, single-aisle transport category airplanes. There are a variety of novel EAP technologies for each of these novel vehicles. And the industry is not only looking at novel technology to advance the state of the art. Instead, the industry is looking to certify these novel aircraft through their regulatory authorities, such as the US Federal Aviation Administration (FAA), the European Union Aviation Safety Authority (EASA), Transport Canada Civil Aviation (TCCA), and Brazil’s Agência Nacional de Aviação Civil (National Civil Aviation Agency, ANAC), as well as other regulatory authorities. The NASA Electrified Powertrain Flight Demonstration (EPFD) project has partnered with two industry partners to advance integrated MW-class powertrain system technology demonstration that includes an assessment of their regulatory and standards gaps in their technology. The EPFD has conducted a generic regulatory gap analysis of hybrid electric engines that aligns with the industry partners’ efforts. The EPFD regulations and standards team is integrated into the industry standards community. The international industry standards community is wrestling with critical key challenges to certification. While some certification elements are proprietary, several technology elements cut across company propriety in aircraft engines (US 14 CFR Part 33 and EASA CS-E, regulations that only reflect reciprocating and turbine engines). The approach that several of these regulatory authorities have taken is to collaborate to address their challenges. The Certification Management Team (CMT) consists of the EASA, FAA, TCCA, and ANAC, and they have begun to address common questions, such as the Loss of Power Control (LOPC) for electric engines. They have reached out to the standards community to seek answers. The industry standards development organizations (SDO) have also looked ahead to address current regulations and standards gaps. The ASTM has built key committees in its ASTM F44 General Aviation Committee and F39 Aircraft Systems Committee. The SAE has established the E-40 Electric Propulsion and AE-10 High Voltage committees.

Standards↗