Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Nonvolatile memory cells from hafnium zirconium oxide ferroelectric tunnel junctions using Nb and NbN electrodes

Ferroelectric tunnel junctions (FTJs) utilizing hafnium zirconium oxide (HZO) have attracted interest as non-volatile memory for microelectronics due to ease of integration into back-end-of-line (BEOL) complementary metal oxide semiconductor fabrication. This work examines asymmetric electrode NbN/HZO/Nb devices with 7 nm thick HZO as FTJs in a memory structure, with an output resistance that can be controlled by read and write voltages. The individual FTJs are measured to have a tunneling electroresistance of 10 during the read state without significant filament conduction formation and reasonable ferroelectric performance. Endurance and remanent polarizations of up to 10 5 cycles and 20 μC/cm 2 , respectively, are measured and are shown to be dependent on the cycling voltage. Electrical measurements demonstrate how magnitude of the write pulse can modulate the high state resistance and the read pulse influences both resistance values as well as separation of resistance states. Then, by using two opposite switching FTJ devices in series, a programmable nonvolatile resistor divider is demonstrated. Measurements of these two FTJ unit memory cells show wide applicability to a BEOL microfabrication process for a re-readable, rewritable, and nonvolatile memory cell.

42 ENGINEERING↗

Enhanced stability of quantum Hall skyrmions under radio-frequency radiations

We present in this paper the results from a recent study on the stability of the quantum Hall skyrmions state at a Landau level filling factor (ν) close to ν = 1 in a narrow GaAs quantum well. Consistent with previous work, a resonant behavior is observed in the resistively detected NMR measurements. In the subsequent current-voltage (I-V) measurements to examine its breakdown behavior under radio frequency radiations, we observe that the critical current assumes the largest value right at the 75 As nuclear resonant frequency. We discuss possible origin for this unexpectedly enhanced stability.

36 MATERIALS SCIENCE↗

Gunn threshold voltage characterization in GaAs devices with wedge-shaped tapering

Here, we fabricate gallium arsenide-based devices with a wedge-shaped tapering region connected to a rectangular-shaped region and measure the threshold voltage required to trigger the Gunn effect. The threshold voltage reduction is attributed to the focusing of the electric field toward the narrower end of the device and is effective when the device has a steep enough tapering. We also model the electric field profile for the tapered devices using an intuitive graphical approach and the finite element method and provide estimates for the threshold voltages of tapered devices. Finally, we compare the estimates to the measured values and provide possible reasons for the discrepancies. We believe the capability of threshold voltage reduction with the wedge-shaped tapering design could be useful in device applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensing and Control During Bulk SPP

In this work, we use the thermoelectricity to directly measure the temperature at different radial positions within instrumented Al1100 billets during friction extrusion. Site-specific and uninterrupted temperature measurements were possible by measuring the local voltages at several thermoelectric junctions consisting of aluminum-nickel pairs during extrusion. Measurements were conducted for a constant die rotation speed of 150 RPM and different extrusion feed rates of 2, 8, 32, and 80 mm.min-1. X-ray computed tomography was used to locate the positions of the thermoelectric junctions inside the processed billet, thus allowing for site-specific microstructural characterization at the precise measurement points. Smooth particle hydrodynamic modeling allowed to determine the thermal, strain, and strain rate fields developing during FE. The applicability and limitations of this temperature measurement approach are discussed as a function of the peak extrusion and torsion stresses relative to the matrix of extrusion feed rates.

42 ENGINEERING↗

TEAMER: Performance mapping of Re Vision's Persistance PTO

Contains datasets from experimental measurements that were used to validate Re Vision's Persistence PTO's efficiency and performance. These measurements were obtained using a dynamometer test bench setup. The data includes open-circuit voltage and loss measurements to validate machine characteristics, efficiency mapping tests to determine the generator's performance mapping, and efficiency mapping tests to determine the converter's efficiency over the feasible operating range. This data was collected between June 2023 and September 2023. The data was collected at the National Renewable Energy Laboratory's Flatirons Campus, Colorado, United States. The data was collected using NREL's 5-kW dynamometer test bench, equipped with a torque sensor and various voltage and current sensors fed to a dedicated data acquisition system. Units for the data are included in the data file headers for each data series. A text editor or spreadsheet software such as Excel is required to view the *.csv data. The data are also provided in *.mat files. To view data plots, a Matlab script with *.mat files are provided.

16 TIDAL AND WAVE POWER↗

Impacts of Non-Ideal Back Contact on Capacitance Measurements in CdTe Solar Cells

CdTe solar cells suffer from a non-ideal back contact which can strongly affect the equivalent circuit model and complicate capacitance measurements. Here, five different back contact materials are deposited on identical CdTe absorbers and their influence on capacitance measurements is characterized. A five-element equivalent circuit model is shown to represent a CdTe solar cell with a non-ideal back contact, and capacitance-frequency (C-f) measurements on each sample clearly show the influence of this contact. Capacitance-voltage (C-V) measurements on each sample show the influence of frequency on measured capacitance. In the AlGaOx/Au sample, temperature dependent C-fs show the back barrier height to be 240 meV, and ongoing measurements will give a comparison of back barrier heights for all samples. This study provides insight into the efficacy of various back contacts and highlights potential errors in the interpretation of capacitance measurements due to the presence of the back contact.

cadmium compounds↗

One-dimensional antilocalization of electrons from spin disorder probed by nonlinear Hall effect

In recent years, nonreciprocal transport measurement has emerged as a probe of spin orbit interaction, spin texture, superconductivity, and other fundamental properties of materials. Here, we study the nonlinear Hall effect (NLHE) in Bi 2 Se 3 /CoFeB heterostructures measured by second harmonic voltage method. Magneto-optical Kerr effect measurements demonstrate the origin of the NLHE to be the asymmetric magnon scattering mechanism. Moreover, a linear relation between the nonlinear Hall resistance and the electron phase coherence length of Bi 2 Se 3 is observed between 5 and 50 K. In this work, we propose a phenomenological model that explains the enhancement of the NLHE below 50 K as a result of one-dimensional antilocalization of electrons from spin disorder, enabled by spin-momentum locking and conservation of angular momentum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TDC with uncontrolled delay lines: calibration approaches and precision improvement methods

The time-to-digital-converter (TDC) using uncontrolled delay lines has a simple structure and finer measurement precision since the delay cells are pure digital gates that operate at maximum speed. For every incoming hit, two “snapshots” of the delay line are taken by the register array with two strobes separated with a known time interval. With two measurements, propagation delays of each cell in the delay line can be calibrated for the operating temperature and voltage. The two measurements can also be averaged to improve the TDC measurement precision. We will discuss various calibration approaches and present test results in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hybrid Detector (Final Technical Report)

We report updates since the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov–Trofimov–Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. This new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Leveraging Cell Expansion Sensing in State of Charge Estimation: Practical Considerations

Measurements such as current and terminal voltage that are typically used to determine the battery’s state of charge (SOC) are augmented with measured force associated with electrode expansion as the lithium intercalates in its structure. The combination of the sensed behavior is shown to improve SOC estimation even for the lithium ion iron phosphate (LFP) chemistry, where the voltage–SOC relation is flat (low slope) making SOC estimation using measured voltage difficult. For the LFP cells, the measured force has a non-monotonic F–SOC relationship. This presents a challenge for estimation as multiple force values can correspond to the same SOC. The traditional linear quadratic estimator can be driven to an incorrect SOC value. To address these difficulties, a novel switching estimation gain is used based on determining the operating region that corresponds to the actual SOC. Moreover, a drift in the measured force associated with a shift of the cell SOC–expansion behavior over time is addressed with a bias estimator for the force signal. The performance of Voltage-based (V) and Voltage and Force-based (V&F) SOC estimation algorithms are then compared and evaluated against a desired ±5% absolute error bound of the SOC using a dynamic stress test current protocol that tests the proposed estimation scheme across wide range of SOC and current rates.

25 ENERGY STORAGE↗

An 802pW 93% Peak Efficiency Buck Converter with 5.5×10 6 Dynamic Range Featuring Fast DVFS and Asynchronous Load-Transient Control

Here this paper presents a buck converter with sub-nW quiescent power, high efficiency, and a wide dynamic range for ultra-low-power (ULP) IoT SoCs. To optimize the SoC power consumption, the buck converter supports fast dynamic voltage and frequency scaling (DVFS) and enables fast load-transient response (FLTR) through asynchronous control. In addition, the buck converter is fully self-contained with all features integrated on chip including a proposed adaptive deadtime controller. Fabricated in 65nm CMOS, measurement results show the buck converter has an 802pW quiescent power at 1.5V input voltage and a 93% peak efficiency. The measured dynamic range is from 0.5nW to 2.75mW, which is over 6 orders of magnitude. The measured voltage droop is 54mV for a 45nA-to-1mA load current step thanks to the asynchronous load-transient detector. The buck converter achieves the highest efficiency and widest dynamic range among all the state-of-the-art sub-nW switching voltage regulators, which makes it well suited for power management in ULP SoCs.

42 ENGINEERING↗

Voltage-dependent excitation dynamics in UV-absorbing organic photovoltaics with efficient charge transfer exciton emission

Intermolecular charge-transfer excitons play a central role in determining the performance of organic solar cells as their voltage-dependent formation, dissociation, and recombination dynamics contribute to photocurrent generation, radiative/nonradiative voltage losses, and photovoltaic fill factor. Here, we explore the properties of brightly-emitting wide energy gap (>2 eV) charge transfer excitons by measuring the voltage-dependent photoluminescence, photocurrent, and ultrafast pump–probe transient absorption spectra of organic solar cells employing five UV-absorbing donor molecules that differ only by the length of the oligophenylene or acene group at their core. We find that organic solar cells with a strong correlation between their voltage-dependent photocurrent and charge-transfer exciton photoluminescence have low photovoltaic fill factors as they require voltage to facilitate efficient charge-transfer exciton dissociation. In contrast, solar cells that are efficient can readily generate charges without an applied field and have a separate population of tightly-bound charge-transfer excitons that are responsible for emission. Furthermore, considering that the sum of all excitation loss rates (i.e., recombination and charge extraction) must be equal to the excitation generation rate in the steady state, these voltage-dependent data allow us to solve for the voltage-dependent fate of all excitations in the solar cells and estimate upper and lower bounds for geminate and non-geminate recombination, respectively.

14 SOLAR ENERGY↗

Analytical Identification Method of Generalized Short‐Circuit Ratio Using Phasor Measurement Units

This paper introduces a novel analytical approach for the identification of the admittance matrix and the generalized short-circuit ratio (gSCR) in power systems integrated with renewable energy sources. The proposed method leverages voltage and current measurements from phasor measurement units (PMUs) to construct a least squares objective function, which is then solved using matrix calculus and partial derivatives. Unlike conventional optimization algorithms, this approach provides an analytical solution that substantially reduces data requirements, enabling the efficient and accurate identification of the gSCR with smaller datasets. Additionally, its fixed computational complexity allows for real-time updates as new data are collected, ensuring continuous refinement of the system of equations and enabling rapid, precise gSCR calculations. The method also exhibits strong robustness against measurement noise, making it well-suited for practical applications in dynamic power systems. The combination of reduced data requirements, real-time adaptability, noise robustness and fixed computational load establishes this method as a highly efficient and reliable tool for real-time power system stability analysis. Case studies on an EPRI 36-bus system demonstrate the method's effectiveness, highlighting its accuracy in closely matching true gSCR values, even under diverse disturbances and noisy conditions.

Han, Zelei [Hohai University, Nanjing (China)] (OR↗

Propagation of non-Gaussian voltage angle fluctuations in high-voltage power grids

Recent measurements have reported non-Gaussian tails in the distribution of frequency data in electric power grids. Large frequency deviations may induce grid instabilities and it is therefore crucial to understand how noise disturbances with long, non-Gaussian tails propagate. Here, we investigate how fluctuations in power feed-in, characterized by non-zero cumulants of their distribution, propagate through high-voltage power grids. Unlike previous investigations which focused on the white-noise limit, we consider the limit of long noise correlation time, where power feed-in fluctuates over times longer than the inherent dynamical time scales of the grid - the relevant regime for large-scale, high-voltage distribution grids. In this work, we show that in this limit, the skewness and kurtosis of the power feed-in distribution propagate similarly as its variance, independently of the distribution of inertia. Non-Gaussianities from individual sources of noise therefore persist throughout the entire network. This finding is corroborated by numerical results on a realistic model of the synchronous grid of continental Europe.

42 ENGINEERING↗

Development of planar P-type point contact germanium detectors for low-mass dark matter searches

The detection of low-energy deposition in the range of sub-eV through ionization using germanium (Ge) with a bandgap of ~ 0.7 eV requires internal amplification of the charge signal. This can be achieved through high electric field that accelerates charge carriers, which can then generate more charge carriers. The minimum electric field required to generate internal charge amplification is derived for different temperatures. We report the development of a planar point contact Ge detector in terms of its fabrication and the measurements of its leakage current and capacitance as a function of applied bias voltage. With the determination of the measured depletion voltage, the field distribution is calculated using GeFiCa, which predicts that the required electric field for internal charge amplification can be achieved in proximity to the point contact. The energy response to an Am-241 source is characterized and discussed. We conclude that such a detector with internal charge amplification can be used to search for low-mass dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Future Standard for Reactive Power Measurement

Reactive power is defined for sinusoidal voltage and current. Several different ways to measure the quantity have been developed, and while they all give the same result for sinusoidal voltages and currents, the results are not the same when the inputs are distorted. Work was done with distorted test signals to explore these—sometimes large— differences, and a report summarizing the findings was published by the US National Institute of Standards and Technology (NIST) in 2011. We show in this paper that the differences are smaller, but not negligible, when the waveforms are less distorted. The differences between the results of the various existing methods are discussed from the viewpoint of measurement theory. The paper argues that it is time to select one method. The relevance to the ongoing revision to IEEE standard 1459 (which defines reactive power for the purposes of measurement) is explored.

reactive power, measurement standard, definitions,↗

Charged Ferroelectric Domain Walls for Deterministic ac Signal Control at the Nanoscale

The direct current (dc) conductivity and emergent functionalities at ferroelectric domain walls are closely linked to the local polarization charges. Depending on the charge state, the walls can exhibit unusual dc conduction ranging from insulating to metallic-like, which is leveraged in domain-wall-based memory, multilevel data storage, and synaptic devices. In contrast to the functional dc behaviors at charged walls, their response to alternating currents (ac) remains to be resolved. Here, we reveal ac characteristics at positively and negatively charged walls in ErMnO 3 , distinctly different from the response of the surrounding domains. By combining voltage-dependent spectroscopic measurements on macroscopic and local scales, we demonstrate a pronounced nonlinear response at the electrode-wall junction, which correlates with the domain-wall charge state. The dependence on the ac drive voltage enables reversible switching between uni- and bipolar output signals, providing conceptually new opportunities for the application of charged walls as functional nanoelements in ac circuitry.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

CORC $^{\circledR}$ cable terminations with integrated Hall arrays for quench detection

ReBCO superconducting cables have the potential to enable compact thermonuclear fusion reactors that operate at magnetic fields exceeding 20 T and allow operation at temperatures far exceeding the boiling point of liquid helium, potentially allowing for demountable magnets. Normal zone detection remains a challenge, and while novel quench detection techniques are an active area of research, few are non-invasive, provide real-time quench detection, and have been demonstrated with current ramp rates relevant for fusion reactors. To address this problem, a CORC$^{\circledR}$ cable termination is developed with integrated Hall sensors to monitor current redistribution as a proxy for quench detection. The methodology exploits the current sharing and layered topology in CORC$^{\circledR}$ cables, and allows quench detection using a localized sensor instead of co-wound voltage wires or optical fibers. Furthermore, experiments are presented where current redistribution is measured from induced quenches, and in a 0.2 meter CORC$^{\circledR}$ sample it is found that the Hall sensors detect normal zone transitions with a similar magnitude and temporal resolution as voltage measurements. To emulate the conditions of dynamic poloidal and central solenoidal fields, experiments are repeated with ramp rates up to 10 kA s -1 that demonstrate the potential to detect normal zone development over a range of experimental parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗