Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

EVs@Scale: NextGen Profiles EVSE Characterization 2025

As part of the U.S. DOE EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles [NGP]) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. Electric Vehicle Service Equipment (EVSE) characterization involves testing over a wide range of DC charging currents and voltages during nominal and off-nominal conditions. This testing allows for a better understanding of the impact that high-power charging will have on the electric grid. A common set of standard test plans, procedures, and data requirements were applied to the characterization in this document with minor updates and improvements. This report covers all conductive characterization activities performed between October 2024 and September 2025 on the Delta Electronics 350KW Electric Vehicle Charging System, consisting of power cabinet model EIDN-U350KTA01 and dispenser model EIDD-U350SSUUAEG-350.Key Findings include: Output regulation, Efficiency and power factor, Load management, Grid Resilience, Smart Charge Management (SCM) performance, Thermal control system performance, Multi-port simultaneous charging performance, and Selected performance comparisons with other EVSEs characterized in the NextGen Profiles project. Hot and cold temperature testing was not conducted on the Delta 350KW due to laboratory limitations. Future research could include continued testing the Delta hardware under off-nominal temperature conditions including multi-port/multi-session simultaneous charge testing, in addition to collecting data on other high-power conductive chargers to augment.

25 ENERGY STORAGE↗

Effect of electrode rinse solutions on the electrodialysis of concentrated salts

The data presented indicate that modest attention to the chemistry of the electrode rinse solution can yield as much as 56% improvement in process efficiency. When operating electrodialysis (ED) with salt concentrations greater than 10,000 mg/l (as NaCl) the amperage can be relatively high even at low voltages. To maximize the overall rate of ion transport from diluate to concentrate, there is a need to minimize resistances in the electrode cells since these can represent as much as 30% of the total resistances in the entire process and in this particular ED unit, represented resistance roughly equivalent to that within the membrane stack. This work describes the performance of a 10-cell pair, 200 cm 2 (0.02 m 2 ) per membrane, pilot ED unit operated in batch mode at 5 V potential. The feedstock to the stack was varied from 0.5% to 6% NaCl. Results from Volt-amp profiles (2.0–15 V) were used as the rationale for choosing the preferred electrode rinse solution, 90 g/l (kg/m 3 ) disodium sulfate at pH 12.5. The recommended solution of 30 g/l (kg/m 3 ) disodium sulfate at neutral pH was tested against stronger solutions (60, 90, and 120 g/l (kg/m 3 ) disodium sulfate) at neutral pH and with 1 g/l (kg/m 3 ) sodium hydroxide added to yield solutions at pH 12.5. There were stark differences in the performance of the ED unit between the solutions at pH 7 and those at pH 12.5. The slopes of the Volt-amp profiles improved indicating less resistance to ion flow at pH 12.5. Most of the difference can be attributed to the greater conductivity of sodium hydroxide compared to disodium sulfate, where even a modest addition of 1 g/l (kg/m 3 ) sodium hydroxide increased the conductivity of the solution between 8 and 20% depending on the concentration of disodium sulfate. Most notably, the initiation voltage was 2.39 ± 0.08 V with solutions at pH 7 and 1.99 V ± 0.04 V when the rinse solutions were around pH 12.5, a difference of around 0.42 V. Since the full batch runs were performed at 5.0 V, this 0.42 V differential represented a loss of 8% in process efficiency. A series of tests showed a shift in initiation voltage occurred between pH 11.5 and 12.5. Nernst equations for water electrolysis are coupled with a simple flux model that estimates the concentration of hydroxide and hydronium ions at the electrode surfaces. This model indicates that the potential demanded by the electrodes is directly linked to the current. Furthermore, there is a steep drop in the potential demanded by the anode when there is sufficient hydroxide available to generate oxygen from hydroxide as opposed to generation from water. The voltage demand is minimal at pH 12.5 and reflective of the reference standard voltage (just over 1.23 V predicted at 0.1 amps). However, the flux model predicts that the voltage demanded by the electrodes at pH 7 is 1.61 V at 0.1 amps (the lowest amperage measurable with the power pack). In conclusion, comparing this result to the reference standard (E 0 = -1.23 V) yields a satisfactory explanation for the observed difference below reference standard of 0.42 V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-World Distribution System Modeling Framework for Transmission-and-Distribution Cosimulation: Preprint

This paper presents a modeling methodology for realistic distribution system simulation and analysis. The methodology involves three major approaches: utility model conversion, feeder load modeling, and feeder model validation. The feeder models obtained from the utility are converted to the format that is more flexible for analysis and algorithm development. The load profiles down to each node are modeled in detail using advanced metering infrastructure data and supervisory control and data acquisition (SCADA) system measured load data. Then the distribution system models are validated by comparing the simulated feeder-head voltage results and SCADA measured voltage data. To better understand the bulk system operations and the interactions between transmission and distribution systems, the modeled realistic distribution systems are integrated into a transmission-and-distribution cosimulation framework to perform the system simulation from the bulk system down to each node in the distribution system.

load modeling↗

Nanosecond Transient Validation of Surge Arrester Models to Predict Electromagnetic Pulse Response

The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. Further, this article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.

42 ENGINEERING↗

Research and Development to Reduce Impurity Production and Transport of the Impurities to the Target in Linear Plasma Devices Using Helicon Plasma Sources

Linear plasma devices used to test plasma facing materials (PFMs) and components for fusion reactors are often suffering under the production of intrinsic impurities from the plasma source system. Most linear plasma devices use internal electrodes (hollow cathodes, reflex arc, or cascading arc), which typically are the source of the main impurities. The next-generation plasma generators use radio frequency (RF) plasma sources like helicons to avoid internal electrodes. However, high power operation of helicons has proven to result in impurity production due to the high rectified sheath voltages created. Depending on the plasma parameters and magnetic configuration, these impurities can be transported to the target and deposited there to unacceptable high levels. Here, in this contribution, the experimental results from Proto-MPEX are summarized, and the conclusions of the impurity source physics are given. Methods to reduce the impurity production, the impurity transport, and the net deposition on the target are presented. These methods to reduce the impurity production include Faraday screens to reduce the sheath voltage drop, high-Z refractory coatings to reduce the erosion yield, and wall conditioning methods. Methods to reduce the impurity transport include changes in the magnetic configuration as well as electron heating to change axial and radial temperature profiles. Preliminary results on the effectiveness of some of these methods are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method for implant and anneal for high voltage field effect transistors

In an example, the present invention provides a method of forming a semiconductor device on a gallium and nitrogen containing material. The method includes providing a substrate member comprising a surface region, the substrate member comprising a gallium and nitrogen bearing material. The method includes causing an implanted species to electrically activate the implant profile while removing one or more crystalline damage from the epitaxial material to change the amorphous state to a single crystalline state, and thereby creating a substantially electrically activated crystalline material.

Shealy, James R.↗

Quantifying concentration distributions in redox flow batteries with neutron radiography

Abstract The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.

Science & Technology - Other Topics↗

Ion Transport in Concentrated Crosslinked Solid Polymer Electrolytes

Crosslinking polymers is a common approach to create mechanically stable solid materials such as polymer electrolytes for lithium batteries. In conventional liquid electrolytes, the solvent molecules move freely to accommodate the field-induced motion of ions. However, in crosslinked polymer electrolytes, the rearrangement of polymer segments is constrained by the deformation limits of the network. Herein, we develop a new transport model that accounts for both the formation of concentration gradients and the elasticity of the electrolyte. The elasticity is incorporated by adding an additional term related to the entropy of crosslinked strands to the electrochemical potential of the salt. The resulting Crosslink Model contains two adjustable parameters: $\mathcal{N}$, the average number of monomers in a strand, and λ crit , the maximum strain the network can sustain. These solid-like constraints produce singularities in the governing transport equations, fundamentally altering the concentration profiles. Plateaus in salt concentrations emerge near the electrodes, and network elasticity introduces a strain overpotential. When compared to a Baseline Model ($\mathcal{N}$ → ∞, equivalent to concentrated solution theory), which predicts steepest gradients near the electrodes, both models yield similar current–voltage relationships. Model predictions are compared to electrochemical data for a poly(ethylene oxide)-based crosslinked polymer electrolyte.

Patel, Vivaan [University of California, Berkeley,↗

EVSE Characterization

NextGen Profiles' EVSE characterization efforts explored performance variability in production EVSE through the use of EV emulation equipment and assessed how different operational conditions influence charging behavior. Data were collected at a frequency of 10 Hz from both the EV emulator and EVSE during each charge session and stored in a time-series database for further analysis. As part of the NextGen Profiles project, characterization of high-power EVSE was performed on both conductive and wireless charging infrastructure; however, only conductive charging data are currently included in this repository. This EVSE characterization was performed over a range of DC output currents and voltages, covering both nominal and off-nominal test conditions. This EVSE characterization dataset includes high-power charging data from two types of 350-kW-capable EVSE using liquid-cooled Combined Charging System-1 (CCS1, North American version) cables and connectors. To protect confidentiality, all EVSE metadata are anonymized, and the publicly released datasets are metered at 10-Hz frequency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method for Spatiotemporal Solar Power Profile Estimation for a Proposed U.S.–Caribbean–South America Super Grid under Hurricanes

Solar photovoltaic (PV) generation technology stands out as a scalable and cost-effective solution to enable the transition toward decarbonization. However, PV solar output, beyond the daily solar irradiance variability and unavailability during nights, is very sensitive to weather events like hurricanes. Hurricanes nucleate massive amounts of clouds around their centers, shading hundreds of kilometers in their path, reducing PV power output. This research proposes a spatiotemporal method, implemented in MATLAB R2023b coding, to estimate the shading effect of hurricanes over a wide distribution of PV solar plants connected to a high-voltage power infrastructure called the U.S.–Caribbean–South America super grid. The complete interconnection of the U.S., the Caribbean, and South America results in the lowest power valley levels, i.e., an overall percentual reduction in PV power output caused by hurricane shading. The simulations assess the impact of hurricanes in 10 synthetic trajectories spanning from Texas to Florida. The Caribbean would also experience lower power valleys with expanded interconnectivity schemes. The U.S.–Caribbean–South America super grid reduces Caribbean variability from 37.8% to 8.9% in the case study. The proposed spatiotemporal method for PV power profile estimation is a valuable tool for future solar power generation expansion, transmission planning, and system design considering the impact of hurricanes.

14 SOLAR ENERGY↗

Effect of microphase separation on the limiting current density in hybrid organic-inorganic copolymer electrolytes

Hybrid organic-inorganic block copolymer electrolytes are of interest to enable batteries containing lithium metal anodes. The conductive block is a standard polymer electrolyte of poly(ethylene oxide) and the mechanically rigid block is an inorganic poly(acryloisobutyl polyhedral oligomeric silsesquioxane) polymer. Here, in this paper, we compare a poly(acryloisobutyl polyhedral oligomeric silsesquioxane)-b-poly(ethylene oxide)-b-poly(acryloisobutyl polyhedral oligomeric silsesquioxane) (POSS-PEO-POSS) triblock copolymer and a poly(ethylene oxide)-b- poly(acryloisobutyl polyhedral oligomeric silsesquioxane) (PEO-POSS) diblock copolymer mixed with lithium bis(trifluoromethanesulfonyl)imide salt. We have experimentally measured the limiting current density in lithium symmetric cells containing hybrid organic-inorganic electrolytes at 90 °C. The cells were polarized at a large range of applied current density. The diblock copolymer electrolyte exhibited a clear plateau in cell potential at all current densities below the limiting current density. At low applied current density, the triblock copolymer electrolyte also exhibited a clear plateau in cell potential. At currents approaching the limiting current density, the triblock copolymer electrolyte exhibited an underdamped potential profile. The cell potential did not reach a plateau at current densities above the limiting current in both systems. The diblock and triblock copolymer electrolytes were fully characterized using electrochemical methods to determine the ionic conductivity, cation current fraction, salt diffusion coefficient, and open circuit voltage as a function of salt concentration. Cell potential and salt concentration as functions of position in the cell at various current densities were calculated using Newman's concentrated solution theory. The theoretical limiting current density was calculated to be the current density at which salt is depleted at the cathode. We see quantitative agreement between experimental measurements and theoretical predictions for the limiting current density in the diblock copolymer electrolyte which has an ordered structure at all salt concentrations, while the experimental limiting current density is lower than the theoretical prediction for the triblock copolymer electrolyte, which exhibits a disordered morphology at high salt concentrations.

25 ENERGY STORAGE↗

Pore-Scale Modeling of Electrokinetics in Geomaterials

Pore-scale finite-volume continuum models of electrokinetic processes are used to predict the Debye lengths, velocity, and potential profiles for two-dimensional arrays of circles, ellipses and squares with different orientations. The pore-scale continuum model solves the coupled Navier–Stokes, Poisson, and Nernst–Planck equations to characterize the electro-osmotic pressure and streaming potentials developed on the application of an external voltage and pressure difference, respectively. Here, this model is used to predict the macroscale permeabilities of geomaterials via the widely used Carmen–Kozeny equation and through the electrokinetic coupling coefficients. The permeability results for a two-dimensional X-ray tomography-derived sand microstructure are within the same order of magnitude as the experimentally calculated values. The effect of the particle aspect ratio and orientation on the electrokinetic coupling coefficients and subsequently the electrical and hydraulic tortuosity of the porous media has been determined. These calculations suggest a highly tortuous geomaterial can be efficient for applications like decontamination and desalination.

36 MATERIALS SCIENCE↗

Sr 2 Fe 2–X Mo X O 6 double perovskites as electrocatalysts for oxidative dehydrogenation of ethane: Effect of B-site stoichiometry

The oxidative dehydrogenation of ethane (ODHE) was investigated using a solid oxide electrocatalytic cell with Sr 2 Fe 2–X Mo X O 6–δ (SFM) double perovskite as the anode electrocatalyst. As shown in the XRD patterns, SFM perovskites maintained their cubic structure upon modifying the B-site ratios of Mo and Fe. Increasing the Mo content of the perovskite structure resulted in a lower water signal intensity at low temperatures in TPR profiles, indicative of moderate oxygen transport through the perovskite structure. Because Mo–O bonds are stronger than Fe–O bonds, the electrical conductivity of SFM perovskites decreased with increasing Mo content. When operated at 100 mA cm –2 , ODHE activity improved four times compared to open circuit voltage, resulting in 16.1% conversion of C 2 H 6 and 83.1% selectivity to C 2 H 4 . It has been demonstrated that oxygen ions provided by perovskite lattices were the key species involved in activating C 2 H 6 based on the in-situ DRIFTS experiments. In conclusion, the SFM perovskite with higher Mo content showed the highest conversion and selectivity due moderate oxygen ion mobility and fast desorption of C 2 H 4 .

25 ENERGY STORAGE↗

Elevated Electron Temperature Coincident with Observed Fusion Reactions in a Sheared-Flow-Stabilized Z Pinch

The sheared-flow-stabilized Z pinch concept has been studied extensively and is able to produce fusion-relevant plasma parameters along with neutron production over several microseconds. In this work, we present elevated electron temperature results spatially and temporally coincident with the plasma neutron source. An optical Thomson scattering apparatus designed for the FuZE device measures temperatures in the range of 1–3 keV on the axis of the device, 20 cm downstream of the nose cone. The 17-fiber system measures the radial profiles of the electron temperature. Scanning the laser time with respect to the neutron pulse time over a series of discharges allows the reconstruction of the T e temporal response, confirming that the electron temperature peaks simultaneously with the neutron output, as well as the pinch current and inductive voltage generated within the plasma. Comparison to spectroscopic ion temperature measurements suggests a plasma in thermal equilibrium. The elevated T e confirms the presence of a plasma assembled on axis, and indicates limited radiative losses, demonstrating a basis for scaling this device toward net gain fusion conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Illumination-induced modulation of conductivity and Gunn oscillation properties in epitaxial GaAs

In this work, we illuminate a gallium arsenide (GaAs) Gunn device and study the light-induced changes of Gunn oscillation properties. We observe that illumination leads to the modulation of the Gunn threshold voltage, the Gunn oscillation magnitude, and the coherency of Gunn oscillation, with the nature of the modulation being closely related to the position of illumination on the device. These effects are attributed to the generation of optically excited carriers, which results in the modulation of conductivity and the electric field profile along the device. The finite element method is used to simulate the change of the field profile of the Gunn device caused by illumination. We also report an unexpected phenomenon of Gunn oscillation property manipulation with an optical chopper. In addition, wavelength-dependent, power-dependent, and pulsed illumination measurements are performed to help with further understanding the observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ionization wave propagation in a He plasma jet in a controlled gas environment

Characterizing ionization wave propagation in low temperature plasma jets is critical to predicting production of reactive species and plasma–surface interactions for biomedical applications and surface functionalization. In this work, results from optical emission and laser induced fluorescence measurements of the ionization wave in a He plasma jet operating in a controlled gas environment are discussed and used for comparison with numerical modeling. Additionally, the ionization wave was observed using ICCD (Intensified Charge Coupled Device) imaging and characterized by time and spatially resolved electron density measurements using laser-collision-induced fluorescence. The plasma jet was initially characterized using pure He (nominally at 200 Torr), while varying pressure and voltage. When operating in pure He, the ionization wave broadly expands exiting the plasma tube. Increasing the operating pressure reduces the speed and isotropic expansion of the ionization wave. Furthermore, the jet operated with a humid He shroud was also studied. The humid He shroud results in the electron density increasing and having an annular profile due to the lower ionization potential of H2O compared to He and localized photoionization in the mixing region. Numerical modeling highlighted the importance of resonance radiation emitted by excited states of He, photoelectron emission from the quartz tube, and the kinetic behavior of the electrons produced by photoionization ahead of the ionization front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interfacial Characterization of Positive Bias Voltage Degradation in PV Modules

Degradation from high system voltage is a prevailing failure mode in fielded photovoltaic modules, and the degradation mechanism is inherently dependent on the bias polarity. Here we report the effects of positive bias. Modules under positive bias demonstrated a significant photocurrent loss caused by two routes. First, delamination and discoloration of the silicon nitride layer, leading to optical loss determined by reflectance measurements. Second, chemical discoloration of the cell gridlines and encapsulant (EVA), which is linked to an electrochemical reaction at the silver electrodes. Chemical compositional analysis using X-ray photoemission spectroscopy demonstrated that the discoloration is attributed to Ag 2 S and/or Ag 2 O. Evidence of Ag ion migration from the cell grid into the encapsulant is observed after shallow depth profiling on the EVA surface. However, Ag was not detected at the EVA/glass interface, inferring limited Ag ion transport through the EVA. The source of sulfur is believed to be ambient air, which diffused into the module through the breathable backsheet.

characterization↗