At least 235 records · Page 13

Computational and Experimental Validation of Fractal-Fin, Dimpled Solar Heat Collector

A 3 foot x 3 foot x 3 foot aluminum solar collector was manufactured using computer numerical control. The interior of the device included six triangular dimpled fins for enhanced heat transfer. The interior vertical wall on the south side was also dimpled. The solar collector working fluid was based on water, and the collector consisted solely of passive heat transfer mechanisms (no moving parts), making it ideal for off-the-grid and rural applications. Two types of heat transfer experiments were conducted. One experiment had external flat heaters attached on the top and the front side, while the other four sides were insulated. Except for the bottom surface, the second experiment had all its exterior surfaces sprayed with black solar paint to collect as much solar heat as possible. Temperature data as a function of time was collected using 14 thermocouples spread strategically throughout the solar collector. In addition, computational fluid dynamics (CFD) simulations were conducted using the dynamic Smagorinsky large eddy simulation turbulence model. The first simulation considered that both the top and front surfaces were exposed to a fixed temperature of 313.7 K (105 °F), while the remaining four surfaces were insulated. For the second simulation, all conditions were the same, except that the temperature for both heated surfaces was raised to 350 K (170.3 °F). The two temperatures are expected to bound the solar collector operational temperature during the late- Spring, Summer, and early-Fall months. The solar collector design, experimental data, CFD output, and a discussion of five manufacturing approaches and costs are documented in this report.

14 SOLAR ENERGY↗

Flow Sensor Test Article (F-STAr) - Water Testing and Commissioning Report for FY2024

Argonne National Laboratory’s Mechanism Engineering Test Loop (METL) facility is developing new experimental testing capabilities with the Flow Sensor Test Article (F-STAr). F-STAr’s mission is to provide high flowrate, sodium submersible testing capabilities to support the development of sodium cooled nuclear fission reactors. Figure 1 shows a model of F-STAr (left) and a photo of the partially assembled test article (right) with several of the main components labeled. The system currently includes a large pump with desired flowrates of up to 100 GPM; an immersion heater with a maximum power of 5 kW; an immersion cooler with an estimated maximum cooling power of 2 kW; and an experimental test section to support sub-test articles. Initially, F-STAr will be setup for testing flow sensors, specifically Eddy Current Flow Sensors (ECFS). However, the system can be reconfigured to support a wide range of testing needs. For example, F-STAr could be setup to complete testing of hydraulic components, heat exchangers, hydrodynamic bearings, seals, and more. This report will provide an update on the development of F-STAr with a focus on the water testing and commissioning activities during Fiscal Year 2024 (FY24). First, the report will focus on describing the pump development. Specifically, updates will be provided on troubleshooting the pump’s excessive vibrational issues. In addition to updates on the pump, pressure-flowrate performance testing in water will be described. Furthermore, updates will be provided on a pump shaft bushing development as well as rigging procedures. Future work and paths forward for F-STAr will be described. Finally, a short summary on the ECFS development will be described at the end of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Nuclear Spent Fuel Disposal in Clay-Bearing Rock - Process Model Development and Experimental Studies

The DOE R&D program under the Spent Fuel Waste Science Technology (SFWST) campaign has made key progress in modeling and experimental approaches towards the characterization of chemical and physical phenomena that could impact the long-term safety assessment of heat-generating nuclear waste disposition in deep clay/shale/argillaceous rock. International collaboration activities such as heater tests and postmortem analysis of samples recovered from these have elucidated key information regarding changes in the engineered barrier system (EBS) material exposed to years of thermal loads. Chemical and structural analyses of sampled bentonite material from such tests has as well as experiments conducted on these are key to the characterization of thermal effects affecting bentonite clay barrier performance and the extent of sacrificial zones in the EBS during the thermal period. Thermal, hydrologic, and chemical data collected from heater tests and laboratory experiments has been used in the development, validation, and calibration of THMC simulators to model near-field coupled processes. This information leads to the development of simulation approaches (e.g., continuum vs. discrete) to tackle issues related to flow and transport at various scales of the host-rock and EBS design concept. Consideration of direct disposal of large capacity dual-purpose canisters (DPCs) as part of the back-end SNF waste disposition strategy has generated interest in improving our understanding of the effects of elevated temperatures on the EBS design. This is particularly important for backfilled repository concepts where temperature plays a key role in the EBS behavior and long-term performance. This report describes multiple R&D efforts on disposal in argillaceous geologic media through development and application of coupled THMC process models, experimental studies on clay/metal/cement barrier and host-rock (argillite) material interactions, molecular dynamic (MD) simulations of water transport during (swelling) clay dehydration, first-principles studies of metaschoepite (UO 2 corrosion product) stability, and advances in thermodynamic plus surface complexation database development. Drift-scale URL experiments provides key data for testing hydrological-chemical (HC) model involving strong couplings of fluid mixing and barrier material chemical interactions. The THM modeling focuses on heater test experiments in argillite rock and gas migration in bentonite as part of international collaboration activities at underground research laboratories (URLs). In addition, field testing at an URL involves in situ analysis of fault slip behavior and fault permeability. Pore-scale modeling of gas bubble migration is also being investigated within the gas migration modeling effort. Interaction experiments on bentonite samples from heater test under ambient and elevated temperatures permit the evaluation of ion exchange, phase stability, and mineral transformation changes that could impact clay swelling. Advances in the development, testing, and implementation of a spent nuclear fuel (SNF) degradation model coupled with canister corrosion focus on the effects of hydrogen gas generation and its integration with Geologic Disposal Safety Assessment (GDSA). GDSA integration activities includes evaluation of groundwater chemistries in shale formations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental and Numerical Evaluation of the Thermal-Fluid Characteristics of the Helium-Cooled Modular Divertor with Multiple Jets Using a Reversed Heat Flux Approach

A single-finger unit of the Helium-Cooled Modular Divertor with Multiple Jets (HEMJ) with a plasma-facing surface (PFS) area of about 2 cm 2 has been studied in a helium (He) loop at He mass flow rates m˙ H ≤ 8 g/s and nearly prototypical conditions. Based on previous studies of the single finger of the HEMJ, our Georgia Institute of Technology group is planning to experimentally study larger divertors. Given that the HEMJ test section was heated with an induction heater and that it is impractical to scale this up to divertors with larger PFS areas, a reversed heat flux approach is being considered to measure heat transfer coefficients (HTCs). In this approach, the direction of the heat flux is reversed with water cooling and high-temperature He heating of the outer shell attached to the PFS. This work presents an initial experimental and numerical evaluation of this approach for a single HEMJ finger. Experiments with brass and copper-chromium-zirconium outer shells were conducted at dimensionless He mass flow rates or Reynolds numbers Re = 1 × 10 4 to 4.7 × 10 4 , an inlet pressure of 10 MPa, temperatures as great as 673 K, and maximum heat flux of 8.4 MW/m 2 . The experiments verify that the He-side HTCs are independent of the direction of the heat flux. Here, the results agree well with previous Nusselt number correlation and pressure loss coefficients for the HEMJ obtained using the normal heating approach.

42 ENGINEERING↗

An international study on THM modelling of the full-scale heater experiment at Mont Terri laboratory

We present results from an international model comparison study of the Full-Scale Emplacement (FE) experiment in Opalinus Clay at the Mont Terri Laboratory, Switzerland. Based on a provided parameter set the teams decided which parameters they adopted for their models, whether they considered the excavation and the ventilation phase in addition to the heating phase and if they included technical features like the shotcrete or the EDZ. The teams were able to reproduce the measured parameters temperature, relative humidity and pore pressure. The modelled results for temperature agree very closely between the teams especially in the sensors in Opalinus Clay. All teams were able to reproduce the redistribution of water in the bentonite backfill due to heating. The evolution of the relative humidity showed similar trends with differences in the intensity of the dry out effect. To model the pore pressure evolution is more complex because it comprises the full interaction of the coupled THM processes. The spread between the pore pressure modelled by the teams was larger, with some teams overestimating the pressure increase due to heating and some teams overestimating the extent of drainage. The agreement of modelled results with measurements improves with larger distance to the heater. We conclude that the EDZ and the shotcrete potentially influence the behaviour of the rock causing higher differences closer to the heater. Further research is needed to better implement those influences into the models. Based on the calibrated models, the future evolution of temperature, relative humidity and pore pressure was predicted over the next 10 years following a change of the heat power applied in 2023 and 2024. Again, the predicted temperatures agree very closely between the teams. Most teams do not expect an increase in relative humidity during the next 10 years after the initial dry-out.

58 GEOSCIENCES↗

Application of Electrochemical Methods to Molten Salt Reactors: Draft TLR Documenting Assessment of Electrochemical Monitoring

Nuclear Regulatory Commission (NRC) is developing the regulatory framework and technical expertise to support regulatory review of advanced non-water reactors, including molten salt reactors (MSRs). In an MSR, it is essential that the salt chemistry be maintained in a desired range in terms of redox potential for reliable operation and mitigation of corrosion to structural materials in the reactor, particularly the reactor vessel and heater exchanger. Measuring the redox potential of the salt in the reactor would also allow for the material lifetimes to be predicted more accurately, and chemical issues to be diagnosed more quickly. In addition to the chemical composition analysis by ICP-MS, electrochemical methods including potentiometry and linear wave scanning (LSC) were also used in molten salt reactor experiment (MSRE) for redox potential monitoring purposes. Electrochemcial methods offers unique advantages such as quick turnaround in results and unique capability of in-line monitoring of redox potential, and are considered popular electroanalytical techniques that can be used to monitor redox potentials and salt chemistry including impurities. The last two decades have seen significant advances in science and engineering of electrochemical methods for potential application to molten salts. The primary goal of this report is to assist NRC in understanding the monitoring of the salt chemistry by electrochemical methods and provide NRC reviewers with necessary information and tools to support regulatory review of MSR designs. This reports consists of two majors parts—Part 1, chemical potential of molten salts and effects by fission process in MSR; Part 2, assessment of electrochemical methods for application to MSRs. The TRLs of the typical relevant electrochemical methods for molten salts were evaluated based on the DOE TRL guidelines and upon a review of the current status of the electrochemical methods for two typical salt systems, fluoride and chloride, for MSRs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nonnuclear Experimental Capabilities to Support Design, Development, and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support nonnuclear testing and demonstration of technology in support of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the Single Primary Heat Extraction and Removal Emulator (SPHERE) and the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes noncontact infrared thermal imaging, surface thermocouples, spatially distributed fiber optic temperature and strain sensors, electrical power meters, and a water-cooled, gas-gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions. The MAGNET facility is a large-scale, 250-kW electrically heated microreactor test bed to enable nonnuclear experimental evaluation of a variety of microreactor concepts. It can be supplied to electrically heat a scaled section of a microreactor and further test the capabilities of heat rejection systems. The initial MAGNET experiments will support technology maturation and reduce uncertainty and risk associated with the design, operation, and deployment of monolithic heat pipe–based reactors. However, this test bed can broadly be applied to multiple microreactor concepts to evaluate a wide range of thermal-hydraulic and structural phenomena such as interface coupling with power conversion units and other collocated systems. MAGNET can evaluate integral thermomechanical effects during electrical heating of an array of heat pipes in a larger test article. Examples of initial testing will include thermal stresses in the monolith and the impact of debonding of a heat pipe from the core block and how that failure could impact surrounding heat pipes, i.e., understanding the potential for cascading failure. This work also discusses some modeling capabilities that can support experiment design, analysis, and interpretation, including the heat pipe code Sockeye and a comparison of thermal-structural simulations performed using ABAQUS and STAR-CCM+.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Capabilities to Support Design, Development and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support non-nuclear demonstration of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the single primary heat extraction and removal emulator (SPHERE) and the microreactor agile non-nuclear experimental test bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes non-contact infrared thermal imaging, surface thermocouples, spatially distributed fiber-optic temperature and strain sensors, electrical power meters, and a water-cooled, gas gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions.

42 ENGINEERING↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method and apparatus for desalinating water

This disclosure concerns a system and a method for removing dissolved solids from liquids. Specific implementations concern desalinating water. The system may comprise a blower, such as a thermal fan/compressor, configured to atomize a solid-bearing liquid to produce a hot, humid gas containing dissolved solids; a gas-solid separator configured to receive hot, humid gas containing entrained dissolved solids from the blower to separate the solids from the humid gas and to transmit the humid gas with solids removed through an exit port; a heater configured to heat the hot, humid gas received from the exit port of the gas-solid separator; and a condenser configured to receive heated humid gas from the heater and to condense solids-free liquid therefrom. The thermal fan/compressor may comprise a plurality of nozzles with outlets positioned adjacent atomization apertures across which a solid-bearing liquid flows and through which gas exiting the nozzles passes.

Abbasi, Bahman↗

Method and apparatus for desalinating water

This disclosure concerns a system and a method for removing dissolved solids from liquids. Specific implementations concern desalinating water. The system may comprise a blower, such as a thermal fan/compressor, configured to atomize a solid-bearing liquid to produce a hot, humid gas containing dissolved solids; a gas-solid separator configured to receive hot, humid gas containing entrained dissolved solids from the blower to separate the solids from the humid gas and to transmit the humid gas with solids removed through an exit port; a heater configured to heat the hot, humid gas received from the exit port of the gas-solid separator; and a condenser configured to receive heated humid gas from the heater and to condense solids-free liquid therefrom. The thermal fan/compressor may comprise a plurality of nozzles with outlets positioned adjacent atomization apertures across which a solid-bearing liquid flows and through which gas exiting the nozzles passes.

Abbasi, Bahman↗

Project Plan: Salt in Situ Heater Test

This project plan gives a high-level description of the US Department of Energy Office of Nuclear Energy (DOE-NE) Spent Fuel and Waste Disposition (SFWD) campaign in situ borehole heater test project planned for the Waste Isolation Pilot Plant (WIPP) site, titled the Brine Availability Test in Salt (BATS). BATS is the first stage in a planned sequence of tests to bolster the technical basis for disposal of heat generating waste in salt. This plan provides an overview of the schedule and responsibilities of the parties involved. This project is a collaborative effort by Sandia, Los Alamos, and Lawrence Berkeley National Laboratories to execute a series of small-diameter borehole heater tests in salt for the DOE-NE SFWD campaign. Design of a heater test in salt at WIPP has evolved over several years. The experiment has begun in January 2020 and the first phase will continue for several months with the possibility for follow on testing. BATS comprises a suite of modular tests, which consist of a group of adjacent horizontal boreholes in the wall of drifts at WIPP. Each test is centered around a packer-isolated heated borehole (12.2 cm [4.81 diameter) containing equipment for water-vapor collection and borehole closure monitoring, surrounded by smaller-diameter (up to 5.3 cm [2.11 diameter) satellite observation boreholes. Observation boreholes contain grouted-in temperature sensors, electrical resistivity tomography (ERT) sensors, and fiber optics; packer-isolated tracer release and sampling intervals; and acoustic emission (AE) piezoelectric sensors. A larger-diameter (12.2 cm [4.81) satellite borehole includes sorel and salt cement plugs, as part of an engineered barrier sealing test. The first two tests, to be implemented in parallel, are heated (target borehole wall temperature of 120 °C) and unheated, with similar arrays of observation borehole monitoring changes. Follow-on tests will be designed using information gathered from the first two tests, and may be conducted at other borehole wall temperatures, use multiple observation boreholes, and may include different measurement types and test designs. This 2020 update of the original 2018 project plan satisfies DOE-NE Spent Fuel and Waste Science and Technology (SFWST) milestone M3SF-205N010303034, as part of the SNL "Salt Disposal R&D" work package.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Volatility-resolved chemical characterization of airborne particles

A method and apparatus for evaluating the chemical composition of airborne particles by sequentially collecting and analyzing airborne particles in-situ. The method includes: collecting particles; enlarging the particles through water condensation; accelerating the enlarged particles onto a surface to collect enlarged particles; and analyzing the enlarged particles by: isolating the surface; passing a carrier gas over the surface; heating the surface to thermally desorb collected particles into the carrier gas; transporting this evolved vapor into detectors; and assaying the evolved vapor as a function of a desorption temperature. The apparatus includes: a sample flow inlet; a condensational growth tube; a collection and thermal desorption (CTD) cell; a carrier gas source; a heater coupled to the CTD; one or more gas detectors; and a controller configured to operate valves, the heater, the growth tube, and the CTD cell in at least an in-situ sequential collection mode and analysis mode.

Isaacman-VanWertz, Gabriel↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Code Benchmark of Depressurized Conduction Cooldown Transient in the High Temperature Test Facility

This paper presents results from modeling of a depressurized conduction cooldown (DCC) transient at the High Temperature Test Facility (HTTF) as part of the OECD-NEA Thermal Hydraulics Code Validation Benchmark for High-Temperature Gas-Cooled Reactors using HTTF Data . This paper briefly describes the benchmark and the models being used. It then presents a comparison of steady state and transient results based on the Problem 2 Exercise 1A and 1B definitions. We compare block and helium temperature distributions, mass flow distribution, and energy balance in steady state. All models show comparable mass flow distributions and energy balances. The temperatures within the core and outer regions are comparable in all models too, but inner reflector temperatures can vary significantly. Despite that, we find that the models are in good agreement for the full-power steady state. In the DCC, we look at block temperature at the core midplane and RCCS water exit temperature. The INL and ANL models are found to be in excellent agreement with one another on block temperature over time, while the agreement when the KAERI and NRG models are added into consideration is good. Differences in the transient heat removal from the RCCS cause the differences in block temperature over time in these models. The CNL models show similar trends to the INL, ANL, KAERI, and NRG models, but the temperatures are high because the volumes used in calculating the average temperature include the heater rods in the CNL models only. The HUN-REN model shows results that suggest significantly lower heat removal in the RCCS which merit further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mitigation of Boiling-Induced Thermal Degradation Using Microporous Nickel Inverse Opals Structures

Engineered microporous structures have received much attention in high-heat-flux electronics cooling due to their high thermal conductivity and permeability, and large surface area for heat transfer, but are susceptible to boiling-induced thermal degradation. Here, this study investigates the efficacy of nickel inverse opals (NiIOs) in mitigating structural degradation caused by corrosion-assisted erosion during pool boiling with water as the working fluid. First, we compared the reliability of NiIOs to copper inverse opals (CuIOs) for a 3-day pool boiling test at constant heat flux. The NiIOs demonstrated superior resistance to thermal degradation due to their inherent corrosion resistance and mechanical strength. Subsequently, we conducted a more controlled experiment to show the effect of heat flux on the degradation of the NiIOs while excluding the effect of temperature variations. Pool boiling tests of 20-μm-thickness NiIOs covering an area of ∼11 × 11 mm 2 with a 2.5 × 2.5 mm 2 heater at the center were conducted at heat flux levels of 20%, 40%, and 60% of the critical heat flux (CHF) for 3 days. The NiIOs subjected to heat flux levels of 20% and 40% CHF showed minimal degradation, while the sample subjected to 60% CHF showed erosion on the top surface due to higher bubble formation and departure rate. These results show the potential of NiIOs as a promising solution for long-term thermal management in high-power electronic devices, although design considerations for maximum allowable heat flux are necessary for reliable operation.

36 MATERIALS SCIENCE↗