Search NASA⌕ Search

SEARCH · Search NASA

Results for “water heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Reversible structural transformations in supercooled liquid water from 135 to 245 K

Water has many anomalous properties compared to “simple” liquids, and these anomalies are typically enhanced in supercooled water.1-3 While numerous models have been proposed, including the liquid-liquid critical point,4,5 the singularity-free scenario,6 and the stability limit conjecture,1 a molecular-level understanding remains elusive. The main difficulty in determining which, if any, of these models is correct is the limited amount of data in the relevant temperature and pressure ranges. For water at ambient pressures, which is the focus of this work, data is largely missing from 160 – 232 K (“No Man’s Land”) due to rapid crystallization.2,3 Whether rapid crystallization is just an experimental obstacle, or a fundamental problem signaling the inability of water to thermally equilibrate prior to crystallization is also a major unanswered question.5,7 Here, we investigate the structural transformations of transiently-heated, supercooled water with nanosecond time resolution using infrared vibrational spectroscopy. The experiments demonstrate three key results. First, water’s structure relaxes from its initial configuration to a “steady-state” configuration prior to the onset of crystallization over a wide temperature range. Second, water’s steady-state structure can be reproduced by a linear combination of two, temperature-independent structures that correspond to a “high-temperature liquid” and a “low-temperature liquid.” Third, the observed structural changes are reversible over the full temperature range. Taken together, these results show that supercooled water can equilibrate prior to crystallization for temperatures from the homogeneous nucleation temperature, TH ~232 K,3 down to the glass transition temperature (Tg ~ 136 K). Second, the results provide support for the hypothesis that supercooled water can be described as a mixture of two, structurally-distinct, interconvertible liquids from 135 K to 245 K.5,8-18

Kringle, Loni M.↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

Heat capacity and thermodynamic functions of partially dehydrated sodium and zinc zeolite A (LTA)

Zeolite A (LTA) is an industrially important zeolite that exhibits sorption-induced framework flexibility, the thermodynamics of which are poorly understood. In this work, we report heat capacity measurements on zinc and sodium zeolite A from 1.8 to 300 K and compare the heat capacity of water in sodium zeolite A with that of water in other zeolites. The heat capacity of zeolitic water varies significantly depending on the hydration level and identity of the host zeolite, and more tightly bound water exhibits strong inflections in its heat capacity curve. This suggests a combination of effects, including differences in water-framework binding strength and hydration-dependent flexibility transitions. We also report fits of the heat capacity data using theoretical functions, and we report values for $C_{P,m}^°$,$Δ_0^TS_m^°$,$Δ_0^TH_m^°$, and $Φ_m^°$ from 0 to 300 K. These results contribute to a systematic thermodynamic understanding of the effects of cation exchange, guest molecule confinement, and sorbate-dependent flexibility transitions in zeolites.

Geochemistry & Geophysics↗

Economic assessment of a multistage surface-heated vacuum membrane distillation process for the treatment of hypersaline produced water

Here, the treatment and disposal of hypersaline produced water remains a challenge, particularly for oil and gas producers in the Permian basin where production wells generate significant amounts of wastewater, and the traditional method of injecting wastewater into disposal wells is coming under increasing scrutiny. Here we investigate the viability of using solar energy to power a multi-stage, surface heated, vacuum membrane distillation (SHVMD) with energy recovery to treat hypersaline produced wastewater from Midland, Texas. Membrane distillation is a process that can desalinate waters with high total dissolved solids concentration, and when incorporated into a system with surface heating and energy recovery can achieve high water recovery rates. Model results show that a 6-stage SHVMD system with a 54.4 % water recovery rate and a gained output ratio (GOR) of 3.28 has the potential to be economically viable when used to treat hypersaline produced water in the Permian basin. Assuming energy costs of $\$0.03$/kWh thermal and $\$0.12$kWh electric , we estimate a project net present value (NPV) of $\$225,525$ and an internal rate of return (IRR) of 13.5 % when an air cooled condensor is used to cool the distillate and a NPV of $\$570,791$ and IRR of 24.52 % when a liquid coooling source is available.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Resolving the Heat of Trimethylaluminum and Water Atomic Layer Deposition Half-Reactions

We report that atomic layer deposition (ALD) is a surface synthesis technique that is characterized by self-limiting reactions between gas-phase precursors and a solid substrate. Although ALD processes have been demonstrated that span the periodic table, a greater understanding of the surface chemistry that affords ALD is necessary to enable greater precision, including area- and site-selective growth. We offer new insight into the thermodynamics and kinetics of the trimethylaluminum (TMA) and H 2 O ALD half-reactions with calibrated and time-resolved in situ pyroelectric calorimetry. The half-reactions produce 3.46 and 2.76 eV/Al heat, respectively, which is greater than the heat predicted by computational models based on crystalline Al 2 O 3 substrates and closely aligned with the heat predicted by standard heats of formation. The pyroelectric thin-film calorimeter offers submilisecond temporal resolution that uniquely and clearly resolves precursor delivery and reaction kinetics. Both half-reactions are observed to exhibit multiple kinetic rates, with average TMA half-reaction rates at least 2 orders of magnitude faster than the H 2 O half-reaction kinetics. Comparing the experimental heat with published computational literature and additional first-principles modeling highlights the need to refine our models and mechanistic understanding of even the most ubiquitous ALD reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat transport in liquid water from first-principles and deep neural network simulations

In this work, we compute the thermal conductivity of water within linear response theory from equilibrium molecular dynamics simulations, by adopting two different approaches. In one, the potential energy surface (PES) is derived on the fly from the electronic ground state of density functional theory (DFT) and the corresponding analytical expression is used for the energy flux. In the other, the PES is represented by a deep neural network (DNN) trained on DFT data, whereby the PES has an explicit local decomposition and the energy flux takes a particularly simple expression. By virtue of a gauge invariance principle, established by Marcolongo, Umari, and Baroni, the two approaches should be equivalent if the PES were reproduced accurately by the DNN model. We test this hypothesis by calculating the thermal conductivity, at the GGA (PBE) level of theory, using the direct formulation and its DNN proxy, finding that both approaches yield the same conductivity, in excess of the experimental value by approximately 60%. Besides being numerically much more efficient than its direct DFT counterpart, the DNN scheme has the advantage of being easily applicable to more sophisticated DFT approximations, such as meta-GGA and hybrid functionals, for which it would be hard to derive analytically the expression of the energy flux. We find in this way that a DNN model, trained on meta-GGA (SCAN) data, reduces the deviation from experiment of the predicted thermal conductivity by about 50%, leaving the question open as to whether the residual error is due to deficiencies of the functional, to a neglect of nuclear quantum effects in the atomic dynamics, or, likely, to a combination of the two.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative phase imaging around water vapor microbubbles under pulsed laser illumination

We measured water temperature around a self-oscillating water vapor-rich bubble using diffraction phase microscopy equipped with a pulsed laser. The water vapor-rich bubble, which causes a strong water flow around it, was generated by locally heating degassed water through the photothermal conversion properties of an FeSi2 thin film. The generation of the flow is related to the self-oscillation of the bubble at sub-MHz frequencies and the temperature distribution around it. Here, the refractive index of the surrounding water was measured using a pulsed laser with a 3.5-ns pulse duration, which guarantees a time resolution of less than 1/200 of the oscillation cycle of the bubble. The temperature distribution around the bubble was calculated from the measured refractive index.

Narihira, Kyoshiro [Kyoto University, Japan]↗

The E3 Initiative

The Department of Energy’s Building Technologies Office is developing a national initiative focused on efficient and clean heating and cooling systems in residential and commercial buildings, making it easier to afford and install high-performance heat pump solutions.

HVAC, residential, commercial, Cold Climate Heat P↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo: Preprint

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. Using GHEDesigner, a lookup table was created to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on agent energy bills. This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of different costing and pricing future scenarios. While the code is still under development and nationwide simulations are ongoing, initial results for two states are provided. Future work includes expanding the module to consider mixed residential and commercial districts and considering multiple costing scenarios.

ambient temperature loop↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.

ambient-temperature loop↗

Sensitivity study of coupled chemical-CFD simulations for analyzing aluminum-clad spent nuclear fuel storage in sealed canisters

We report the United States Department of Energy (DOE) manages over 50 Metric Tons Heavy Metal (MTHM) of aluminum-clad spent nuclear fuel. One main source for DOE’s Aluminum-clad spent nuclear fuel (ASNF) inventory is the advanced test reactor (ATR) at the INL site, which makes this fuel of particular interest for storage scenarios. Road-ready and final disposition packaging configurations for the ATR fuel dictates storage within helium-backfilled, sealed DOE standard canisters. The conditions within these sealed canisters for extended (greater than50 year dry) storage is of interest. To further this goal, a three-dimensional (3D) multi-physics computational fluid dynamics (CFD) model is developed of the sealed DOE standard canisters. This 3D CFD model is one-way coupled with bulk gas radiolysis reactions considering sealed canisters with inert gas and possible trace amounts of air and water vapor. This study looks at the evolution of the thermal history of the canisters over a 50 year time period with a coupling to the chemical reactions occurring from radiolytic breakdown of residual water. A sensitivity study is then carried out over the parameters of the model including the fuel decay heat, residual water content, sealed pressure, canister external temperature, and canister emissivity. In pure helium, hydrogen generation rates are low, under 10 ppm, but hydrogen generation rates are affected greatly by the presence of even 1% residual air, increasing by 50-plus-fold, and nitric acid generation with residual air also occurs ranging from 500 to 4000 ppm after 50 years. The fuel decay heat and the residual water content show the most importance in the generation of hydrogen gas in pure air, and for nitric acid with a residual air condition. External temperature, canister emissivity and sealed pressure all show minor sensitivity effects to the generation of potentially harmful species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗

Prokaryotic responses to a warm temperature anomaly in northeast subarctic Pacific waters

Recent studies on marine heat waves describe water temperature anomalies causing changes in food web structure, bloom dynamics, biodiversity loss, and increased plant and animal mortality. However, little information is available on how water temperature anomalies impact prokaryotes (bacteria and archaea) inhabiting ocean waters. This is a nontrivial omission given their integral roles in driving major biogeochemical fluxes that influence ocean productivity and the climate system. Here we present a time-resolved study on the impact of a large-scale warm water surface anomaly in the northeast subarctic Pacific Ocean, colloquially known as the Blob, on prokaryotic community compositions. Multivariate statistical analyses identified significant depth- and season-dependent trends that were accentuated during the Blob. Moreover, network and indicator analyses identified shifts in specific prokaryotic assemblages from typically particle-associated before the Blob to taxa considered free-living and chemoautotrophic during the Blob, with potential implications for primary production and organic carbon conversion and export.

54 ENVIRONMENTAL SCIENCES↗

Guia de Calentadores de Agua con Bomba de Calor para Pequenas Empresas

Esta guia esta destinada a propietarios de edificios y administradores de instalaciones interesados en electrificar los sistemas de calentamiento de agua de edificios comerciales a traves de sistemas nuevos o reemplazos. Esta guia tambien es un recurso para que los contratistas se familiaricen con los calentadores de agua comerciales con bomba de calor. Esta guia se enfoca en equipos de calentadores de agua con bomba de calor de fuente de aire unitario (estilo tanque), y aqui se incluyen informacion basica, mejores practicas y consideraciones clave. Un ingeniero debe ayudar a identificar las consideraciones especificas exclusivas de los sistemas individuales, segun sea necesario. This is the Spanish translation of NREL/FS-5500-84401, Heat Pump Water Heater Guide for Small Businesses.

decarbonization↗

Heat and mass transfer in hygroscopic hydrogels

Sorption and desorption with hygroscopic hydrogels hold significant promise for thermal management, passive cooling, thermal energy storage, and atmospheric water harvesting. However, a comprehensive understanding of the energy and mass transport mechanisms in hygroscopic hydrogels remains missing, impeding accurate modeling and optimization. In this paper, we develop a model for the simultaneous vapor, water, and heat transfer in hygroscopic hydrogels during sorption and desorption processes. We show that by considering vapor diffusion in the hydrogel micropores, water diffusion in the polymer mesh, and heat transfer in the porous hydrogel, we can accurately capture experimentally observed thermally-driven desorption rates in these hydrogels. Furthermore, we consider three typical operating configurations of hydrogels and elucidate the differences in the transport mechanisms depending on the configuration. Finally, for each of these configurations, we identify key design parameters, including hydrogel thickness, hydrogel shear modulus, heat transfer coefficient, and thermal conductivity, and we parametrically show that by varying these parameters, a hygroscopic hydrogel can desorb up to 128.5%, 14.9%, 69.7%, and 9.6% more water, respectively, relative to the initial water content. This work provides a generic framework to model sorption and desorption processes in hygroscopic hydrogels which can guide the design and optimization in applications of thermal management, passive cooling, thermal energy storage, and atmospheric water harvesting with hydrogels.

36 MATERIALS SCIENCE↗

Advancing hydrogen production: A comprehensive review of wastewater reforming techniques, feedstocks, and opportunities

Wastewater is produced across nearly all human activities and requires treatment to safeguard human health and the natural environment. Treatment of wastewater often requires a large amount of thermal energy, resulting in wasted heat after the treatment process. Because hydrocarbon reforming needs both water and heat, the integration of wastewater treatment with hydrocarbon reforming, a process that produces synthesis gas rich in hydrogen, offers an excellent opportunity to utilize this waste heat and the impurities in wastewater to produce valuable hydrogen gas, to minimize waste from industrial processes, and to integrate water treatment with the hydrogen economy. Yet, no comprehensive literature review has been conducted to examine the integration of reforming and wastewater. To address this lack, we summarize the variety of catalytic reforming techniques available in the open literature and review the current literature on wastewater reforming with these techniques. Subsequently, we conduct a review of common types of wastewater contaminants and their possible effects on reforming catalyst performance and life. Lastly, three underexamined wastewater sources are identified, namely, oilfield wastewater, geothermal water, and mining and mineral processing wastewater, and their potential for future study as a reforming feedstock is examined.

08 HYDROGEN↗