Search NASA⌕ Search

SEARCH · Search NASA

Results for “(IMP)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Evaluation of the IMP-16 microprocessor orbit determination system filter

The results of the numerical tests performed in evaluating the interplanetary monitoring platform-16 orbit determination system are presented. The system is capable of performing orbit determination from satellite to satellite tracking data in applications technology satellite range and range rate format. The estimation scheme used is a Kalman filter, sequential (recursive) estimator. Descriptions of the tests performed and tabulations of the numerical results are included.

Shenitz, C. M.↗

Latitudinal and field-aligned cosmic ray gradients 2 to 5 AU Voyagers 1 and 2 and IMP 8

Results are presented showing that the contemporary picture of a relatively small heliocentric radial gradient is generally correct. They emphasize that such a gradient should really be thought of in terms of field-aligned structures since the cosmic ray populations tend to 'corotate' locally with the interplanetary field structure. Nonuniform latitudinal gradients of approximately 2 to 5 percent/deg in structures lasting 10 to 30 days are identified unambiguously. Additional evidence is seen for somewhat smaller latitudinal gradients often north to south and probably mixed with small field-aligned gradients of less than 1 percent/AU that persist for several solar rotations. It is suggested that these smallest ephemeral latitudinal gradients manifest themselves by affecting the degree of irregularity in diurnal variations of high latitude neutron monitors.

Roelof, E. C.↗

IMF draping around the geotail - IMP 8 observations

The draping pattern for the full range of IMF directions is mapped in the GSM yz-plane using a large data set for studying magnetic field draping around the tail. Based on the maps, it is concluded that the dominant pattern is draping as found by Ohtani and Kokubun (1991) and Sanchez and Siscoe (1990). A new finding is that the draping pattern is rotated relative to the plane formed by the IMF and the aberrated x-axis, with the degree of rotation varying from zero for strongly northward and southward IMF to a peak of 17 deg for moderately southward IMF. It is also found that the tail radius is bigger for southward IMF than for northward IMF.

Kaymaz, Zerefsan↗

Constraints on Martian Soil Composition as Inferred from Viking XRFS and Pathfinder APXS and IMP Data

With the successful operation of the Alpha Proton X-Ray Spectrometer (APXS) during 1997's Mars Pathfinder (MPF) mission, geochemistry data are now available from three sites on Mars. APXS raw spectra for six soils and five rocks have been converted to compositional abundances. The Viking Lander X-Ray Fluorescence Spectrometer (XRFS) successfully measured elemental abundances of nine soils at Viking 1 and eight soils at Viking 2. Although the three landing sites are located in different parts of Mars, the soils exhibit broad similarities, with an iron-rich chemistry similar to that of palagonite. However, the Pathfinder sods show some significant differences from Viking soils, notably an enrichment in silica and depletion in sulfur. The XRFS samples consisted of near-surface and deep (up to 22 cm) soils acquired by a collector head at the cod of a retractable boom. It was possible to collect and analyze pebbles as large a 2 cm, but only sod, some in the form of consolidated clods, was sampled. In contrast, the APXS measured materials in situ. This resulted in MPF "rock" analyses that probably had a significant dust component and, as explored here, "soil" analyses that may have contained a rocky component We examine several possibilities to explain these differences and other attributes of the APXS and XRFS data sets: 1) The APXS soil measurements actually sampled a mixture of Viking-like soil and small bits of high-silica, low-sulfur rock, 2) The soils were derived from high-silica rocks mixed with a minor component of globally-homogenized dust; these soils are chemically distinct and have a separate geologic history from the Viking soils. 3) The weathering environment was different at the Pathfinder landing site compared to the Viking sites, and 4) Uncertainties in the XRFS and APXS measurements result in reported elemental abundances different than those that are actually present We show that none of the possibilities can be discounted, but that an MPF soil distinct in composition from Viking sods is best supported by the available data.

Bridges, N. T.↗

Nature of Fluctuations on Directional Discontinuities Inside a Solar Ejection: Wind and IMP 8 Observations

A solar ejection passed the Wind spacecraft between December 23 and 26, 1996. On closer examination, we find a sequence of ejecta material, as identified by abnormally low proton temperatures, separated by plasmas with typical solar wind temperatures at 1 AU. Large and abrupt changes in field and plasma properties occurred near the separation boundaries of these regions. At the one boundary we examine here, a series of directional discontinuities was observed. We argue that Alfvenic fluctuations in the immediate vicinity of these discontinuities distort minimum variance normals, introducing uncertainty into the identification of the discontinuities as either rotational or tangential. Carrying out a series of tests on plasma and field data including minimum variance, velocity and magnetic field correlations, and jump conditions, we conclude that the discontinuities are tangential. Furthermore, we find waves superposed on these tangential discontinuities (TDs). The presence of discontinuities allows the existence of both surface waves and ducted body waves. Both probably form in the solar atmosphere where many transverse nonuniformities exist and where theoretically they have been expected. We add to prior speculation that waves on discontinuities may in fact be a common occurrence. In the solar wind, these waves can attain large amplitudes and low frequencies. We argue that such waves can generate dynamical changes at TDs through advection or forced reconnection. The dynamics might so extensively alter the internal structure that the discontinuity would no longer be identified as tangential. Such processes could help explain why the occurrence frequency of TDs observed throughout the solar wind falls off with increasing heliocentric distance. The presence of waves may also alter the nature of the interactions of TDs with the Earth's bow shock in so-called hot flow anomalies.

Vasquez, Bernard J.↗

Leg intramuscular pressures during locomotion in humans

To assess the usefulness of intramuscular pressure (IMP) measurement for studying muscle function during gait, IMP was recorded in the soleus and tibialis anterior muscles of 10 volunteers during treadmill walking and running by using transducer-tipped catheters. Soleus IMP exhibited single peaks during late-stance phase of walking [181 +/- 69 (SE) mmHg] and running (269 +/- 95 mmHg). Tibialis anterior IMP showed a biphasic response, with the largest peak (90 +/- 15 mmHg during walking and 151 +/- 25 mmHg during running) occurring shortly after heel strike. IMP magnitude increased with gait speed in both muscles. Linear regression of soleus IMP against ankle joint torque obtained by a dynamometer produced linear relationships (n = 2, r = 0.97 for both). Application of these relationships to IMP data yielded estimated peak soleus moment contributions of 0.95-1.65 N . m/kg during walking, and 1.43-2.70 N . m/kg during running. Phasic elevations of IMP during exercise are probably generated by local muscle tissue deformations due to muscle force development. Thus profiles of IMP provide a direct, reproducible index of muscle function during locomotion in humans.

Clinical Trial↗

Intramuscular Pressure Measurement During Locomotion in Humans

To assess the usefulness of intramuscular pressure (IMP) measurement for studying muscle function during gait, IMP was recorded in the soleus and tibialis anterior muscles of ten volunteers during, treadmill walking, and running using transducer-tipped catheters. Soleus IMP exhibited single peaks during late-stance phase of walking (181 +/- 69 mmHg, mean +/- S.E.) and running (269 +/- 95 mmHg). Tibialis anterior IMP showed a biphasic response, with the largest peak (90 +/- 15 mmHg during walking and 151 +/- 25 mmHg during running) occurring shortly after heel strike. IMP magnitude increased with gait speed in both muscles. Linear regression of soleus IMP against ankle joint torque obtained by a dynamometer in two subjects produced linear relationships (r = 0.97). Application of these relationships to IMP data yielded estimated peak soleus moment contributions of 0.95-165 Nm/Kg during walking, and 1.43-2.70 Nm/Kg during running. IMP results from local muscle tissue deformations caused by muscle force development and thus, provides a direct, practical index of muscle function during locomotion in humans.

Ballard, Ricard E.↗

Intramuscular pressures for monitoring different tasks and muscle conditions

Intramuscular fluid pressure (IMP) can easily be measured in man and animals. It follows the law of Laplace which means that it is determined by the tension of the muscle fibers, the recording depth and by fiber geometry (fiber curvature or pennation angle). Thick, bulging muscles create high IMPs (up to 1000 mmHg) and force transmission to tendons becomes inefficient. High resting or postexercise IMPs are indicative of a compartment syndrome due to muscle swelling within a low-compliance osseofascial boundary. IMP increases linearly with force (torque) independent of the mode or speed of contraction (isometric, eccentric, concentric). IMP is also a much better predictor of muscle force than the EMG signal. During prolonged low-force isometric contractions, cyclic variations in IMP are seen. Since IMP influences muscle blood flow through the muscle pump, autoregulating vascular elements, and compression of the intramuscular vasculature, alterations in IMP have important implications for muscle function.

NASA Discipline Musculoskeletal↗

Intermediate Molecular Phenotypes to Identify Genetic Markers of Anthracycline-Induced Cardiotoxicity Risk

Cardiotoxicity due to anthracyclines (CDA) affects cancer patients, but we cannot predict who may suffer from this complication. CDA is a complex trait with a polygenic component that is mainly unidentified. We propose that levels of intermediate molecular phenotypes (IMPs) in the myocardium associated with histopathological damage could explain CDA susceptibility, so variants of genes encoding these IMPs could identify patients susceptible to this complication. Thus, a genetically heterogeneous cohort of mice (n = 165) generated by backcrossing were treated with doxorubicin and docetaxel. We quantified heart fibrosis using an Ariol slide scanner and intramyocardial levels of IMPs using multiplex bead arrays and QPCR. We identified quantitative trait loci linked to IMPs (ipQTLs) and cdaQTLs via linkage analysis. In three cancer patient cohorts, CDA was quantified using echocardiography or Cardiac Magnetic Resonance. CDA behaves as a complex trait in the mouse cohort. IMP levels in the myocardium were associated with CDA. ipQTLs integrated into genetic models with cdaQTLs account for more CDA phenotypic variation than that explained by cda-QTLs alone. Allelic forms of genes encoding IMPs associated with CDA in mice, including AKT1, MAPK14, MAPK8, STAT3, CAS3, and TP53, are genetic determinants of CDA in patients. Two genetic risk scores for pediatric patients (n = 71) and women with breast cancer (n = 420) were generated using machine-learning Least Absolute Shrinkage and Selection Operator (LASSO) regression. Thus, IMPs associated with heart damage identify genetic markers of CDA risk, thereby allowing more personalized patient management.

60 APPLIED LIFE SCIENCES↗

ISEE/IMP observations of simultaneous upstream ion events

Propagation of upstream energetic (50-200 keV) ions is analyzed in sixteen events observed simultaneously by solid state detectors on ISEE 3 at about 200 earth radii and on IMP 8 at about 35 earth radii from the earth. Conclusions are based on comparisons of the pitch angle distributions observed at the two spacecraft and transformed into the solar wind frame. They are beamlike at ISEE 3 and are confined to the outward hemisphere. When IMP 8 is furthest from the bow shock, they are also usually beamlike, or hemispheric. However, when IMP 8 is closer to the bow shock, pancakelike distributions are observed. This systematic variation in the IMP 8 pitch angle distributions delimits a scattering region l less than about 15 earth radii upstream of the earth's bow shock (l measured along the interplanetary magnetic field) that dominates ion propagation, influences the global distribution of fluxes in the foreshock, and may play a role in acceleration of the ions. When IMP 8 is beyond l of about 15 earth radii the propagation appears to be essentially scatter-free between IMP 8 and ISEE 3; this is deduced from the absence of earthward fluxes at IMP 8 as well as the tendency for the spin-averaged fluxes to be comparable at the two spacecraft.

Mitchell, D. G.↗

Intramuscular pressure and electromyography as indexes of force during isokinetic exercise

A direct method for measuring force production of specific muscles during dynamic exercise is presently unavailable. Previous studies indicate that both intramuscular pressure (IMP) and electromyography (EMG) correlate linearly with muscle contraction force during isometric exercise. The objective of this study was to compare IMP and EMG as linear assessors of muscle contraction force during dynamic exercise. IMP and surface EMG activity were recorded during concentric and eccentric isokinetic plantarflexion and dorsiflexion of the ankle joint from the tibialis anterior (TA) and soleus (SOL) muscles of nine male volunteers. Ankle torque was measured using a dynamometer, and IMP was measured via catheterization. IMP exhibited better linear correlation than EMG with ankle joint torque during concentric contractions of the SOL and the TA, as well as during eccentric contractions. IMP provides a better index of muscle contraction force than EMG during concentric and eccentric exercise through the entire range of torque. IMP reflects intrinsic mechanical properties of individual muscles, such as length-tension relationships, which EMG is unable to assess.

Aratow, M.↗

Intramuscular pressure: A better tool than EMG to optimize exercise for long-duration space flight

A serious problem experienced by astronauts during long-duration space flight is muscle atrophy. In order to develop countermeasures for this problem, a simple method for monitoring in vivo function of specific muscles is needed. Previous studies document that both intramuscular pressure (IMP) and electromyography (EMG) provide quantitative indices of muscle contraction force during isometric exercise. However, at present there are no data available concerning the usefulness of IMP versus EMG during dynamic exercise. Methods: IMP (Myopress catheter) and surface EMG activity were measured continuously and simultaneously in the tibalis anterior (TA) and soleus (SOL) muscles of 9 normal male volunteers (28-54 years). These parameters were recorded during both concentric and eccentric exercises which consisted of plantarflexon and dorsiflexon of the ankle joint. A Lido Active Isokinetic Dynamometer concurrently recorded ankle joint torque and position. Results: Intramuscular pressure correlated linearly with contraction force for both SOL (r exp 2 = 0.037) and TA (R exp 2 = 0.716 and r exp 2 = 0.802, respectively). During eccentric exercises, SOL and TA IMP also correlated linearly with contraction force (r(exp 2) = 0.883 and r(exp 2) = 0.904 respectively), but SOL and TA EMG correlated poorly with force (r(exp 2) = 0.489 and r(exp 2) = 0.702 respectively). Conclusion: IMP measurement provides a better index of muscle contraction force than EMG during concentric and eccentric exercise. IMP reflects intrinsic mechanical properties of individual muscles, such as length tension relationships. Although invasive, IMP provides a more powerful tool and EMG for developing exercise hardware and protocols for astronauts exposed to long-duration space flight.

Hargens, A. R.↗