Search NASA⌕ Search

SEARCH · Search NASA

Results for “ASHRAE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Understanding the Temporal and Spatial Variability of New Generation Gridded TMYs

Presentation at ASHRAE about the spatial and temporal variability of gridded TMYs, discussing advanced GIS and Web services that allow for direct access to data, surface-based observations for thousands of stations, climate reanalysis data, and products derived from satellite data; new developments in NREL's solar databases based on both observed data and satellite-derived gridded data, status of TMY3 weather files, and NREL's plans for the next-generation TMY weather files; and also covers what is new and different in the Climatic Design Conditions Table in the 2013 ASHRAE Handbook of Fundamentals.

54 ENVIRONMENTAL SCIENCES↗

Presidential Address: Building Our New Energy Future

Sheila J. Hayter, P.E., Presidential Member/Fellow ASHRAE and Distinguished Lecturer, is a group manager with the Integrated Applications Center at the Department of Energy's National Renewable Energy Laboratory (NREL) in Golden, Colo., where she has worked since 1992. She leads a team of experts who support international, federal, state, and local entities with the goal of significantly reducing nonrenewable energy consumption. As the ASHRAE president, this is her presidential speech.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ComStock/COVID-19: U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies

ComStock is a DOE platform, with NREL as the lead developer, that models the U.S. commercial building stock using OpenStudio/EnergyPlus to perform physics-based building energy modeling simulations. The ASHRAE Epidemic Taskforce (ASHRAE-ETF) has released several COVID-19 mitigation strategies for commercial buildings. ComStock was used to analyze the impact of four strategies on the existing commercial building stock. These strategies are upgrading to MERV-13 filters, disabling demand control ventilation (DCV), increasing minimum outdoor air to 100%, and HVAC flushing mode operation. Results show the impact of each measure on energy consumption, electric consumption, gas consumption and peak electric.

30 DIRECT ENERGY CONVERSION↗

Model Energy Codes End-Use Opportunity Analysis

Model energy codes (ASHRAE Standard 90.1 and IECC) has significantly impacted programs and policies aimed at improving energy efficiency both in United States and across the globe. Standard 90.1, first published in 1975 (originally referred to as Standard 90) provides minimum energy efficiency guidelines for designing, constructing, operating, and maintaining new construction and renovated buildings. It is updated continuously, with new editions published every 3 years. Pacific Northwest National Laboratory (PNNL) conducts simulated energy and cost savings analysis of model energy codes to determine their expected impact and to track progress toward net-zero goals and efficiency targets. Additionally, the simulation outputs are examined to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles. This end-use opportunity analysis of model energy codes provides ASHRAE technical committees and other interested parties a better understanding of how the Standard affects various building systems and end uses, specifically, those in the Standard that most prominently influence energy efficiency. Additionally, findings provide industry stakeholders guidance in identifying building types and end-uses with the most potential for energy efficiency improvements through energy codes and those that may require beyond code measures to meet energy use reduction targets. This paper summarizes features and functionalities of a webtool created by PNNL to explore and visualize the End-Use opportunity analysis.

ASHRAE 90.1, Energy Codes, Tableau↗

U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies

The COVID-19 pandemic highlights the importance of improving building indoor air quality to reduce occupants' chances of contracting airborne illness. The ASHRAE Epidemic Task Force (ASHRAE-ETF) released several COVID-19 mitigation strategies at the onset of the pandemic. This study explores four of those recommendations for reducing transmission of COVID-19 inside buildings: (1) 100% outdoor air ventilation, (2) MERV-13 or better filters, (3) demand control ventilation removal, and (4) HVAC flushing mode. These recommendations were simulated and assessed using ComStock, a model of the U.S. commercial building stock. The study showed the 100% outdoor air ventilation recommendation had the largest impact on energy consumption, noncoincident peak demand, and thermostat violations. Removing demand control ventilation had the smallest national aggregate impact, installing MERV-13 filters led to slight increases in energy use and peak demand, and HVAC outdoor air flushing led to modest energy use and peak demand increases.

building energy modelling↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Efficacy of occupancy-based smart ventilation control strategies in energy-efficient homes in the United States

Proper ventilation of residences is essential for occupant health and comfort, and is responsible for a significant portion of energy consumption in homes. This study examines a method for providing adequate ventilation in homes while reducing energy consumption and peak demand: “smart” control of ventilation through sensing of occupancy and modulation of ventilation fans. We first conducted a detailed simulation study of advanced California homes with several occupancy-based ventilation control strategies. We then look at how general these results are nationally through a second simulation campaign in 15 ASHRAE climate zones. All simulations compared equivalent indoor air quality situations and assessed energy savings benefits. A key difference from previous demand-controlled ventilation strategies is that our study includes the effects of building related contaminants that are continuously emitted, irrespective of occupancy status, consistent with the requirements in ASHRAE Standard 62.2-2016. Under this new assumption, it is very difficult to extract substantial energy savings using only occupancy sensing. For the baseline strategy, savings were less than 10% of ventilation energy and sometimes negative in all cases analyzed other than leakier 2-story homes. Addition of a pre-occupancy flush period increases savings somewhat, but savings are still less than 15% other than in 2-story leakier homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Learning-based CO 2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation

There have been increasing concerns over the air quality inside buildings as high levels of bio-effluents can cause nausea, dizziness, headaches, and fatigue to the people working in those spaces. First published in 2004 as Standard 62.1, ASHRAE Standard 62.2-2019 requires highly occupied spaces to implement heating, ventilation, and air conditioning (HVAC) that can dilute contaminants produced by occupants. In this regard, occupant-centric ventilation control has been regarded as an effective practice to maintain a satisfactory indoor air quality (IAQ) when dealing with highly variable occupancy environments. However, few established models in current literature and practice consider dynamic occupancy behavior and adaptive IAQ control. To address this gap, a dynamic indoor CO2 model is constructed using machine learning algorithms to forecast CO2concentrations across a range of forecasting horizons. Herein, we tuned and compared six state-of-the-algorithms—including Support Vector Machine, Ada Boost, Random Forest, Gradient Boosting, Logistic Regression, and Multilayer Perceptron. The algorithms’ performances are validated using CO 2 and historical meteorological data collected from a campus classroom with a variable occupancy rate. Simulation results showed that Multilayer Perceptron can strongly predict the volatile CO 2 behavior and also outperforms other algorithms in terms of accuracy. Furthermore, a control strategy capable of modeling and detecting dynamic patterns of CO 2 level is utilized to modulate the ventilation rate in real-time and also reduce the energy consumption. The proposed controller reduced the HVAC fan’s energy consumption by 51.4% and provide ventilation as needed per the ASHRAE standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Angular selective window systems: Assessment of technical potential for energy savings

Static angular selective shading systems block direct sunlight and admit daylight within a specific range of incident solar angles. The objective of this study is to quantify their potential to reduce energy use and peak demand in commercial buildings using state-of-the art whole-building computer simulation software that allows accurate modeling of the behavior of optically-complex fenestration systems such as angular selective systems. Three commercial systems were evaluated: a micro-perforated screen, a tubular shading structure, and an expanded metal mesh. This evaluation was performed through computer simulation for multiple climates (Chicago, Illinois and Houston, Texas), window-to-wall ratios (0.15-0.60), building codes (ASHRAE 90.1-2004 and 2010) and lighting control configurations (with and without). The modeling of the optical complexity of the systems took advantage of the development of state-of-the-art versions of the EnergyPlus, Radiance and Window simulation tools. Results show significant reductions in perimeter zone energy use; the best system reached 28% and 47% savings, respectively without and with daylighting controls (ASHRAE 90.1-2004, south facade, Chicago,WWR=0.45). As a result, angular selectivity and thermal conductance of the angle-selective layer, as well as spectral selectivity of low-emissivity coatings, were identified as factors with significant impact on performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monthly average clear-sky broadband irradiance database for worldwide solar heat gain and building cooling load calculations

This paper establishes the formulation of a new clear-sky solar radiation model appropriate for algorithms calculating cooling loads in buildings. The aim is to replace the ASHRAE clear-sky model of 1967, whose limitations are well known and are reviewed. The new model is derived in two steps. The first step consists of obtaining a reference irradiance dataset from the REST2 model, which uses a high-performance, validated, two-band clear-sky algorithm. REST2 requires detailed inputs about atmospheric conditions such as aerosols, water vapor, ozone, and ground albedo. The development of global atmospheric datasets used as inputs to REST2 is reviewed. For the most part, these datasets are derived from space observations to guarantee universality and accuracy. In the case of aerosols, point-source terrestrial measurements were also used as ground truthing of the satellite data. The second step of the model consists of fits derived from a REST2-based reference irradiance dataset. These fits enable the derivation of compact, but relatively accurate expressions, for beam and diffuse clear-sky irradiance. The fitted expressions require the tabulation of only two pseudo-optical depths for each month of the year. The resulting model, and its tabulated data, are expected to be incorporated in the 2009 edition of the ASHRAE Handbook of Fundamentals. (author)

14 SOLAR ENERGY↗

An open-source framework for simulation-based testing of buildings control strategies

Here this paper presents a simulation framework for evaluating building control strategies (BCSs), developed with VOLTTRON, an opensource platform that integrates data, devices, and systems for sensing and control applications, and is based on co-simulation interfaces. It realizes an integrated environment for both testing and deploying BCSs, thereby eliminating the need for having a dedicated implementation of BCS for testing. For the first time, this framework provides critical functionalities, including scalable communication management and time-drive simulation advance, i.e., advancing the simulation based on clock time. We applied this framework to evaluating two BCSs from ASHRAE Guideline 36-2008 and ASHRAE Standard 90.1-2019. The evaluation results show that those BCSs primarily benefit the heating operation by reducing gas usage but yield insignificant savings in electricity consumption. The results also emphasize the importance of tuning the parameters of the BCSs to achieve better performances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating internal moisture generation rates in recently constructed, occupied homes in the southeastern United States

Internal moisture generation (IMG), or moisture generated by building occupants via activities such as respiration, cooking, bathing, and cleaning, is a critical input required for design, analysis, and simulation of building enclosure and heating, ventilation, and air conditioning (HVAC) systems. Based on previously published values, ASHRAE Standard 160-2021 provides guidance for estimating IMG rates for moisture control design analysis, which is based on occupied home datasets collected in the 1980s and 1990s. Residential energy use simulation software also utilizes estimates for IMG for energy rating, energy analysis, and code compliance calculations, as specified in ANSI/RESNET/ICC Standard 301. Data quantifying IMG rates in newer homes is useful in determining the continued relevance of current design and simulation guidance, and whether the guidance represents conditions found in new housing stock. ASHRAE Research Project 1844, conducted by the Florida Solar Energy Center (FSEC), a research institute of the University of Central Florida, estimated IMG rates in newer occupied homes built since 2013 in the southeastern US using a moisture balance model approach. Furthermore, the project obtained occupied home data in cooperation with a US Department of Energy Building America research project to characterize indoor air quality (IAQ) in newer US homes, along with presence, functionality, and occupant use of control measures. Full-scale laboratory homes operating with known IMG rates were used to validate a moisture balance model and quantify the accuracy of estimates obtained when the model is applied to data from occupied homes with unknown IMG rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Impact of Radiative Cooling Paints in Warehouses Under Various United States Climates

Although radiative cooling research is widely found in the literature, no comprehensive study has yet been conducted on the impact of novel radiant cooling (>0.91 reflectance) on the energy efficiency of warehouses. Here, in this work, we develop three building models based on a Department of Energy prototype warehouse model using trnsys, representing a typical warehouse with a black roof, a typical warehouse with a white roof, and a warehouse with novel radiative cooling (RC) paint on its roof. These models are run for 15 different cities, each representative of a different ASHRAE climate zone, to better understand the impact of RC in many different climates. It was found that an RC-coated roof in a warehouse could reduce the building's annual heating, ventilation, and air conditioning (HVAC) loads by up to 14.11 kWh/m 2 of the roof area compared to a black roof, resulting in a maximum reduction in energy costs of 0.55 $\$$/m 2 or $\$$2646/year for a large 4835 m 2 warehouse. Similarly, replacing the typical white roof coating with an RC coating could reduce the warehouse's energy consumption by up to 8.17 kWh/ m 2 of roof area, thus reducing energy costs by as much as 0.29 $\$$/m 2 or $\$$1386/year for a 4835 m 2 warehouse. In addition, applying RC paint to an unconditioned warehouse could reduce the building's ASHRAE Standard 55 indoor temperature exceedance by up to 1330 h/year compared to a black roof and up to 532 h/year compared to a white roof.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

Development of a Supermarket Prototype Building Model

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry reviews, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. However, the current set of commercial prototype building models does not include a supermarket building type, which is one of major building types defined in the Energy Information Administration’s Commercial Building Energy Consumption Survey. As part of an ongoing effort to expand the current Commercial Building Prototype Model suite, this paper presents the procedure used to develop the prototype supermarket building model based on multiple studies as well as a previously developed reference building model. The final set of prototype models includes 68 models for different vintages of ASHRAE Standard 90.1 (i.e., 2004, 2007, 2010, and 2013) and for 17 ASHRAE climate zones.

Im, Piljae↗

ANSI/ASHRAE/IES Standard 90.1-2010 Final Qualitative Determination

A final qualitative analysis of all addenda to American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2007 (Standard 90.1-2007 or 2007 edition) that were included in ANSI/ASHRAE/IESNA Standard 90.1-2010 (Standard 90.1-2010 or 2010 edition) was conducted. All 109 addenda processed by ASHRAE in the creation of Standard 90.1-2010 from Standard 90.1-2007 were evaluated by DOE for their impact on energy efficiency. DOE determined whether each addendum would have a positive, neutral, or negative impact on overall building efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IESNA Standard 90.1-2007 Preliminary Qualitative Determination

A preliminary qualitative analysis of all addenda to American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2004 that were included in ANSI/ASHRAE/IESNA Standard 90.1-2007 was conducted. All 44 addenda processed by ASHRAE in the creation of Standard 90.1-2007 from Standard 90.1-2004 were evaluated by the U.S. Department of Energy (DOE) for their impact on energy efficiency. DOE preliminarily determined whether that addenda would have a positive, neutral, or negative impact on overall building efficiency. Table S.1 shows the number of positive and negative changes for each section of Standard 90.1. The results of the textual analysis indicate that the majority of changes (30 of the total of 44 listed) were neutral. These include editorial changes, changes to reference standards, changes to alternative compliance paths, and other changes to the text of the standard that may improve the usability of the standard, but do not generally improve or degrade the energy efficiency of building. There were 11 changes that were evaluated as having a positive impact on energy efficiency and 2 changes that were evaluated as having a negative impact on energy efficiency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Typical hot water draw patterns based on field data

There is significant variation in hot water use and draw patterns among households. This report describes typical hot water use patterns in single-family residences in North America. We found that daily hot water use is highly variable both among residences and within the same residence. We compared the results of our analysis of the field data to the conditions and draw patterns established in the current U.S. Department of Energy (DOE) test procedure for residential water heaters. The results show a higher number of smaller draws at lower flow rates than used in the test procedure. The data from which the draw patterns were developed were obtained from 12 separate field studies. This report describes the ways in which we managed, cleaned, and analyzed the data and the results of our data analysis. After preparing the data, we used the complete data set to analyze inlet and outlet water temperatures. Then we divided the data into three clusters reflecting house configurations that demonstrated small, medium, or large median daily hot water use. We developed the three clusters partly to reflect efforts of the ASHRAE standard project committee (SPC) 118.2 to revise the test procedure for residential water heaters to incorporate a range of draw patterns. ASHRAE SPC 118.2 has identified the need to separately evaluate at least three, and perhaps as many as five, different water heater capacities. We analyzed the daily hot water use data within each cluster in terms of volume and number of hot water draws. The daily draw patterns in each cluster were characterized using distributions for volume of draws, duration of draws, time since previous draw, and flow rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗