Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Control C#”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Hypofractionated and Accelerated Radiotherapy With Subcutaneous Amifostine Cytoprotection as Short Adjuvant Regimen After Breast-Conserving Surgery: Interim Report

Purpose: Short radiotherapy schedules might be more convenient for patients and overloaded radiotherapy departments, provided late toxicity is not increased. We evaluated the efficacy and toxicity of a hypofractionated and highly accelerated radiotherapy regimen supported with cytoprotection provided by amifostine in breast cancer patients treated with breast-conserving surgery. Methods and Materials: A total of 92 patients received 12 consecutive fractions of radiotherapy (3.5 Gy/fraction for 10 fractions) to the breast and/or axillary/supraclavicular area and 4 Gy/fraction for 2 fractions to the tumor bed). Amifostine at a dose of 1,000 mg/d was administered subcutaneously. The follow-up of patients was 30-60 months (median, 39). Results: Using a dose individualization algorithm, 77.1% of patients received 1,000 mg and 16.3% received 750 mg of amifostine daily. Of the 92 patients, 13% interrupted amifostine because of fever/rash symptoms. Acute Grade 2 breast toxicity developed in 6.5% of patients receiving 1,000 mg of amifostine compared with 46.6% of the rest of the patients (p < .0001). The incidence of Grade 2 late sequelae was less frequent in the high amifostine dose group (3.2% vs. 6.6%; p = NS). Grade 1 lung fibrosis was infrequent (3.3%). The in-field relapse rate was 3.3%, and an additional 2.2% of patients developed a relapse in the nonirradiated supraclavicular area. c-erbB-2 overexpression was linked to local control failure (p = .01). Distant metastasis appeared in 13% of patients, and this was marginally related to more advanced T/N stage (p = .06). Conclusion: Within a minimal follow-up of 2.5 years after therapy, hypofractionated and accelerated radiotherapy with subcutaneous amifostine cytoprotection has proved a well-tolerated and effective regimen. Longer follow-up is required to assess the long-term late sequelae.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GN/C translation and rotation control parameters for AR/C (category 2)

Detailed analysis of the Automatic Rendezvous and Capture problem indicate a need for three different regions of mathematical description for the GN&C algorithms: (1) multi-vehicle orbital mechanics to the rendezvous interface point, i.e., within 100 n.; (2) relative motion solutions (such as Clohessy-Wiltshire type) from the far-field to the near-field interface, i.e., within 1 nm; and (3) close proximity motion, the nearfield motion where the relative differences in the gravitational and orbit inertial accelerations can be neglected from the equations of motion. This paper defines the reference coordinate frames and control parameters necessary to model the relative motion and attitude of spacecraft in the close proximity of another space system (Region 2 and 3) during the Automatic Rendezvous and Capture phase of an orbit operation.

Henderson, David M.↗

The National Ignition Facility Data Repository

NIF is the world's largest and most energetic laser experimental system, providing a scientific center to study inertial confinement fusion and matter at extreme energy densities and pressures. This presentation discusses the design, architecture, and implementation of the NIF Data Repository (NDR), which provides for the capture and long-term digital storage of peta-scale datasets produced by conducting experimental campaigns. The NDR is a federated database that provides for the capture of: experimental campaign plans, machine configuration & calibration data, raw experimental results and the processed results produced by scientific workflows. The NDR provides for metadata, pedigree, quality, effectivity, versioning and access control for each of the data categories. A critical capability of the NDR is its extensive data provisioning capabilities and protocols that enable scientists, local and remote alike, to review the results of analysis produced by the NDR's analysis pipeline or to download datasets for offline analysis. The NDR provides for the capture of these locally-produced analysis results to enable both peer review and follow-on automated analysis.

42 ENGINEERING↗

Decoupling Li out-diffusion and surface diffusion in the lithiation-assisted epitaxial growth of lithium tungstate

Lithiation-assisted epitaxy offers a flexible and robust approach for synthesizing high-quality Li-containing materials and interfaces with precise control. Here, in this study, we use lithium tungstate (Li x WO 3+x/2 , where x = 0 to 2) as a model system to investigate the intertwined effects of Li out-diffusion-induced compositional changes and surface-diffusion-induced morphological changes. By systematically varying synthesis and processing conditions, we uncover their impact on lithium tungstate film formation. Comprehensive characterizations, including X-ray diffraction, atomic force microscopy, X-ray photoemission spectroscopy and time-of-flight secondary ion mass spectrometry, reveal that low-temperature growth (< 300 °C) followed by high-temperature annealing yields continuous lithium tungstate films with significantly reduced surface roughness. In contrast, high-temperature deposition (≥ 300 °C) accelerates surface diffusion and Li out-diffusion, leading to island formation. Furthermore, in situ scanning transmission electron microscopy demonstrates the beam sensitivity of Li 2 WO 4 and reveals a phase transition from Li 2 WO 4 to LiWO 3.5 under prolonged electron beam exposure. These findings deepen our understanding of how to control composition and morphology of Li-containing films, providing valuable insights for the design and integration of energy materials.

Shi, Jueli [Pacific Northwest National Laboratory ↗

Resonant Control for Fermilab's PXIE RFQ

The RFQ for Fermilab's PXIE test program is designed to accelerate a < 10 mA H⁻ CW beam to 2.1 MeV. The RFQ has a four-vane design, with four modules brazed together for a total of 4.45 m in length. The RF power required is < 130 kW at 162.5 MHz. A 3 kHz limit on the maximum allowable frequency error is imposed by the RF amplifiers. This frequency constraint must be managed entirely through differential cooling of the RFQ's vanes and outer body and associated material expansion. Simulations indicate that the body and vane coolant temperature should be controlled to within 0.1 degrees C. We present the design of the cooling network and the resonant control algorithm for this structure, as well as results from initial operation.

43 PARTICLE ACCELERATORS↗

Vacuum system of the cyclotrons in VECC, Kolkata

The vacuum system of the K=130 Room Temperature Cyclotron (RTC) (operational since 1978) has been recently modernized and the same of the K{sub bend}=520 Superconducting Cyclotron (SCC), currently under commissioning, is being deployed for remote monitoring and control. The vacuum system of RTC is designed to achieve and maintain vacuum level of 2 X 10{sup -6} mbar inside 23 m{sup 3} volume of Resonator tank and DEE tank. This has been upgraded by replacing several valves, Freon units, gauges and pumps. The relay based manual control system has been replaced by PLC based automated system. The SCC vacuum system also has an elaborate arrangement comprising of turbo molecular pumping modules with associated isolation valves and characteristic gauges. This paper describes essential elements, typically used to obtain high (1X10{sup -7} mbar) vacuum using rotary pumps, diffusion pumps and cold traps/turbo-molecular pumps and other system components such as valves, gauges and baffles. The supervisory control methodology/scheme of both the vacuum systems, developed in-house using EPICS (Experimental Physics and Industrial Control System), a standard open-source software tool for designing distributed control system, is also elaborated here. (author)

43 PARTICLE ACCELERATORS↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

Hydration of potassium citrate-activated BOF slag

Basic Oxygen Furnace (BOF) slag is currently utilized with low-grade applications or landfilled. Here, we investigate a novel route to upgrade BOF slag to a high-performance binder by chemical activation with tri-potassium citrate. The impact of tri-potassium citrate on hydration and phase assemblage of BOF slag is analyzed with a multi-technique approach. Results reveal that the addition of tri-potassium citrate considerably enhances the reactivity of brownmillerite and accelerates the hydration of belite at early ages. The majority of brownmillerite hydrates within 24 h, and the reaction kinetics is controlled by the activator dosage. The main products of BOF slag hydration are siliceous hydrogarnet and C-S-H gel. Acting as a strong water reducer, tri-potassium citrate enables the manufacture of slag pastes with high compressive strength (up to 75 MPa at 28 days) and low porosity. Leaching of heavy metals from the slag pastes fulfills the Dutch Soil Quality Decree limits.

36 MATERIALS SCIENCE↗

Long Term Degradation of LSM Based SOFC Cathodes: Use of a Proven Accelerated Test Regimen

The overall goals of the program were: • To understand the microstructural basis of long-term performance loss in solid oxide fuel cells (SOFCs) with cathodes based on lanthanum strontium manganite (LSM, (La 1–x Sr x ) 1–yM nO 3±z ); • To develop strategies for optimizing LSM–based cathodes that achieve improved long-term performance, while exhibiting microstructural and chemical stability, for commercial fuel cell systems. The research project carried out accelerated testing of SOFCs with LSM-based cathodes of selected compositions. After intervals of accelerated testing (and control tests using non-accelerated conditions), the cells underwent extensive microstructural characterization to determine the physical and chemical changes in the cells. By analysis of a) the results of the testing, b) the observed microstructural changes, and c) the differences in these correlations between different cathode compositions and test durations, the research: • Identified a correlation between microstructural change and performance loss: specifically, between decrease of three-phase boundary (TPB) density and increase of area specific re-sistance (ASR) during operation; • Identified a cathode composition parameter — Mn excess, defined as 1/(1–y) in (La 1–x Sr x ) 1–y MnO 3±z ) — and how it affects TPB density, ASR and change of cell performance over time.

08 HYDROGEN↗

RHIC 12x150A current lead temperature controller: design and implementation

There are 60 12 x 150A current leads distributed in six RHIC service buildings; each lead delivers power supply current from room temperature to cryogenic temperature in RHIC. Due to the humid environment, condensation occurs frequently and ice forms quickly during operation, especially during an extensive storage period. These conditions generate warnings and alarms to which personnel must respond and establish temporary solutions to keep the machine operating. In here, we designed a temperature control system to avoid such situations. This paper discusses its design, implementation, and some results. There are six service buildings in the RHIC complex; each building has two valve boxes that transfer room-temperature current cables from the power supplies into superconducting leads, and then transport them into the RHIC tunnel. In there, the transition between the room-temperature lead into superconducting lead is critical and essential; smooth running during the physics store is crucial for the machine's continuing operation. One of the problems that often occurred previously was the icing of these current leads that could result in a potential leakage current onto ground, thereby preventing a continuous supply of physics store. Fig. 1 illustrates a typical example on a power lead. Among the modifications of the design of the valve box, we list below the new requirements for designing the temperature controller to prevent icing occurring: (1) Remotely control, monitor, and record each current lead's temperature in real time. Prevent icing or overheating of a power lead. (2) Include a temperature alarm for the high/low level threshold. In this paper we discuss the design, implementation, upgrades to, and operation of this new system.

43 PARTICLE ACCELERATORS↗

Vibration isolation technology - An executive summary of systems development and demonstration

A program was organized to develop the enabling technologies needed for the use of Space Station Freedom as a viable microgravity experimental platform. One of these development programs was the Vibration Isolation Technology (VIT). This technology development program grew because of increased awareness that the acceleration disturbances present on the Space Transportation System (STS) orbiter can and are detrimental to many microgravity experiments proposed for STS, and in the future, Space Station Freedom (SSF). Overall technological organization are covered of the VIT program. Emphasis is given to the results from development and demonstration of enabling technologies to achieve the acceleration requirements perceived as those most likely needed for a variety of microgravity science experiments. In so doing, a brief summary of general theoretical approaches to controlling the acceleration environment of an isolated space based payload and the design and/or performance of two prototype six degree of freedom active magnetic isolation systems is presented.

Grodsinsky, C. M.↗

Observation of Hypervelocity Dust in Dense Supersonic Plasma Flows: Physics and Applications

Synthetic diamond and graphite dust powders with a wide range of sizes, from a few to several tens of microns in diameter were accelerated to velocities up to 4 km/s in vacuum by plasma jet produced in a coaxial gun. Some of the key features of the plasma flow are high density, of the order of 10{sup 22} m{sup -3}, low ion and electron temperatures, of only a few eV, and good collimation over a distance of {approx_equal}2 m due to confinement by the self-generated magnetic field. The main features of this plasma-drag acceleration technique are presented and discussed. From basic science point of view hypervelocity dust is useful for studying the physics of dust interaction with energetic plasma flows at microscopic level. In physical applications, it has been proposed to use hypervelocity dust for diagnostic or control of magnetically confined fusion plasmas. In engineering, hypervelocity dusty plasmas are extensively employed in industrial processes involved in the processing of surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Medipix3 array high performance read-out board for synchrotron research

The Medipix3 ASIC is one of the most advanced chip that is presently available to build photon counting area detectors. The capabilities of the chip include adjacent pixels charge summing circuitry to sort out the distortion due to charge sharing, simultaneous counting and read-out that enables frames to be acquired without dead time, the colour mode of operation that enables up to eight energy bands to be acquired. In order to fully exploit the capabilities of the Medipix3 chip in synchrotron research, a high performance electronic board capable of driving large arrays of chips is necessary. We propose a parallel read-out board of Medipix3 chip arrays with a scalable architecture that allows driving the Medipix3 chip in all of its modes of operation. The board functions include the control of the chip arrays, data formatting and data compression, the management of the communications with the data storage devices, and operation in various trigger modes. In addition to this the board will have some 'intelligence' embedded. This will add some very important features to the final detector such as pattern recognition, capability of variable frame duration as a function of the photon flux, feedback to other equipment and real time calculations of data relevant to experiments such as the autocorrelation function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemically induced crystallization of amorphous materials in molten MgCl2: boron nitride and hard carbon

A novel and versatile strategy for the amorphous-to-crystalline transformation of boron nitride (BN) with the capability to control the degree of crystallization was developed through an electrochemical pathway using MgCl 2 at low temperature (750 °C). This procedure can be extended to the transformation of amorphous carbon to graphite, which significantly reduces the energy and cost, accelerates the synthesis process and could potentially replace industrial graphite synthesis globally. Therefore, the synthesized graphite exhibits much enhanced electrochemical performance at high charge–discharge rates (5C) compared to commercial synthetic graphite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exercise Increases the Cardiovascular Stimulus Provided by Artificial Gravity

We investigated fluid shifts and regulatory responses to variations of posture, exercise, Gz level and radius of rotation in subjects riding NASA Ames 20G centrifuge. Results are from 4 protocols that address radius and exercise effects only. Protocol A: After 10 min supine control, 12 healthy men (35 plus or minus 9 yr, 82.8 plus or minus 7.9 kg) were exposed to rotational 1 Gz (2.5 m radius) for 2 min followed by 20 min alternating between 1 and 1.25 Gz. Blood samples were taken pre and post spin. Protocol B: Same as A, but lower limb exercise (70% V02max) preceded ramps to 1.25 Gz. Protocol C: Same as A but radius of rotation 8.3 m. Protocol D: Same as B but at 8.3 m. The 8 subjects who completed all protocols, increased heart rate (HR) from control, on average, by: A: 5, B: 39, C: 11, D: 44 bpm. For thoracic fluid volume, (bioimpedance), the 8 subjects changed from control, on average: A: -394, B: -548, C: -537, D: -708 mL. For thigh fluid volume, changes from control, on average, were: A: -137, B: 129, C: -75, D: 159 mL. Hematocrit changes from control were: A: 2.3, B: 3.5, C: 2.3, D: 4.3 %. Radius effects were mild and included greater loss of fluid from the thorax, less fluid loss from the thigh and increased heart rate at the longer radius. Pre-acceleration exercise effects were more dramatic and included additional loss of fluid from the chest, increased fluid volume of the thigh, increased hematocrit and greater heart rate increases. We propose that short bouts of intense exercise can be used to magnify the cardiovascular stress delivered by artificial gravity (AG) training and the combination of AG with exercise training can be fine-tuned to preserve orthostatic tolerance of astronauts during spaceflight.

Howarth, M. S.↗

A Cryogenic Test Stand for Large Superconducting Solenoid Magnets

A new test stand for testing large superconducting solenoid magnets at the Fermilab Central Helium Liquifier (CHL) has been designed, and operated. This test stand has been used to test a coupling coil for the Muon Ionization Cooling Experiment (MICE), and future uses include solenoids for the Fermilab mu2e experiment. This paper describes the test stand design and operation including controlled cool-down and warm-up. Overviews of the process controls system and the quench management system are also included.

43 PARTICLE ACCELERATORS↗