Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Diamond X-ray Beam Position Monitors

Modern Synchrotrons are capable of significant per-pulse x-ray flux, and time resolved pulse-probe experiments have become feasible. These experiments provide unique demands on x-ray monitors, as the beam position, flux and arrival time all potentially need to be recorded for each x-ray pulse. Further, monitoring of white x-ray beam position and flux upstream of beamline optics is desirable as a diagnostic of the electron source and insertion device alignment. We report on diamond quadrant monitors which provide beam diagnostics for a variety of applications, for both white and monochromatic beams. These devices have a position resolution of 25 nm for a stable beam, are linear in flux over at least 11 orders of magnitude, and can resolve beam motion shot-by-shot at repetition rates up to 6.5 MHz.

43 PARTICLE ACCELERATORS↗

High Efficiency Visible Photocathode Development

The alkali antimonides are of significant interest to the accelerator community, as they have a high quantum efficiency (QE) under illumination by green light. These cathodes are attractive for high-average-current photoinjector applications and understanding their fundamental properties are critical to the production of long lived, reliable cathodes. We report on ongoing work to characterize cathode formation during growth. In-situ X-ray Diffraction (XRD) has been used to compare grain size and texture in antimony layers, and X-ray Photoelectron Spectroscopy (XPS) has been used to investigate the solid-state chemistry of cathode formation.

36 MATERIALS SCIENCE↗

Detector positioning for the initial subcriticality level determination in accelerator-driven systems

Within the GUINEVERE project (Generation of Uninterrupted Intense Neutrons at the lead Venus Reactor) carried out at SCK-CEN in Mol, the continuous deuteron accelerator GENEPI-3C was coupled to the VENUS-F fast simulated lead-cooled reactor. Today the FREYA project (Fast Reactor Experiments for hYbrid Applications) is ongoing to study the neutronic behavior of this Accelerator Driven System (ADS) during different phases of operation. In particular the set-up of a monitoring system for the subcriticality of an ADS is envisaged to guarantee safe operation of the installation. The methodology for subcriticality monitoring in ADS takes into account the determination of the initial subcriticality level, the monitoring of reactivity variations, and interim cross-checking. At start-up, the Pulsed Neutron Source (PNS) technique is envisaged to determine the initial subcriticality level. Thanks to its reference critical state, the PNS technique can be validated on the VENUS-F core. A detector positioning methodology for the PNS technique is set up in this paper for the subcritical VENUS-F core, based on the reduction of higher harmonics in a static evaluation of the Sjoestrand area method. A first case study is provided on the VENUS-F core. This method can be generalised in order to create general rules for detector positions and types for full-scale ADS. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Recovery of Neptunium-236g from Photon and Proton-Irradiated Actinide Targets

Neptunium-236g is a rare radionuclide used as a tracer for neptunium-237 analyses. The availability of 236gNp is limited and the viable production routes are costly, time consuming, and only produce trace quantities of the desired product. For this work, two known production methods were tested to determine product recovery, purity, and viability for use as a tracer. The first method utilizes a photon-irradiated 237Np target to produce 236gNp by the 237Np(?,n)?236Np reaction. The second method utilizes the 238U(d,4n) ?236Np reaction. These production routes were evaluated previously, and the former was considered ineffective without isotope separation and the latter was not well-characterized for the 236mNp/236gNp production ratio. Recent resurgence of electromagnetic isotope separation technology has enabled at least partial recovery of 236gNp from part-per-million abundance feeds produced by the photonuclear reaction. To address the lack of production data for the second method, a deuteron-irradiated depleted uranium target was chemically processed to recover and purify the Np for abundance and ratio analyses. The status and current analytical results for each production method are presented.

07 ISOTOPE AND RADIATION SOURCES↗

MUSETT and the Spectroscopy of Heavy Elements at GANIL

The new MUSETT silicon-wall has been built to study and obtain detailed spectroscopic information on the transfermium and transactinide elements. MUSETT is located at GANIL at the detection plane of VAMOS, the latter coupled with the EXOGAM germanium array. Results from the in-beam commissioning are reported and an overview of our future experimental program will be given.

43 PARTICLE ACCELERATORS↗

High gradient research and facilities at Los Alamos National Laboratory [Slides]

A particle accelerator is a scientific instrument that produces a directional stream of electrically charged particles, usually electrons or protons. The accelerator propels particles to high speeds, close to the speed of light. Historically, accelerators play a crucial role in scientific discovery. Nowadays, accelerators produce particle beams for biomedical and material research, manufacturing, energy technology, and Homeland security.

43 PARTICLE ACCELERATORS↗

A 6 kV arbitrary waveform generator for the Tevatron Electron Lens

This paper reports on a 6 kV modulator built and installed at Fermilab to drive the electron gun anode for the Tevatron Electron Lens (TEL). The TEL was built with the intention of shifting the individual (anti)proton bunch tunes to even out the tune spread among all 36 bunches with the desire of improving Tevatron integrated luminosity. This modulator is essentially a 6 kV arbitrary waveform generator that enables the TEL to define the electron beam intensity on a bunch-by-bunch basis. A voltage waveform is constructed having a 7 μs duration that corresponds to the tune shift requirements of a 12-bunch (anti)proton beam pulse train. This waveform is played out for any one or all three bunch trains in the Tevatron. The programmed waveform voltages transition to different levels at time intervals corresponding to the 395 ns bunch spacing. In addition, complex voltage waveforms can be played out at a sustained rate of 143 kHz over the full 6 kV output range. This paper describes the novel design of the inductive adder topology employing five transformers. It describes the design aspects that minimize switching losses for this multi-kilovolt, high repetition rate and high duty factor application.

43 PARTICLE ACCELERATORS↗

A Dual-Sided Coded-Aperture Radiation Detection System , Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment

We report the development of a large-area, mobile, coded-aperture radiation imaging system for localizing compact radioactive sources in three dimensions while rejecting distributed background. The 3D Stand-Off Radiation Detection System (SORDS-3D) has been tested at speeds up to 95 km/h and has detected and located sources in the millicurie range at distances of over 100 m. Radiation data are imaged to a geospatially mapped world grid with a nominal 1.25- to 2.5-m pixel pitch at distances out to 120 m on either side of the platform. Source elevation is also extracted. Imaged radiation alarms are superimposed on a side-facing video log that can be played back for direct localization of sources in buildings in urban environments. The system utilizes a 37-element array of 5 x 5 x 50 cm{sup 3} cesium-iodide (sodium) detectors. Scintillation light is collected by a pair of photomultiplier tubes placed at either end of each detector, with the detectors achieving an energy resolution of 6.15% FWHM (662 keV) and a position resolution along their length of 5 cm FWHM. The imaging system generates a dual-sided two-dimensional image allowing users to efficiently survey a large area. Imaged radiation data and raw spectra are forwarded to the RadioNuclide Analysis Kit (RNAK), developed by our collaborators, for isotope ID. An intuitive real-time display aids users in performing searches. Detector calibration is dynamically maintained by monitoring the potassium-40 peak and digitally adjusting individual detector gains. We have recently realized improvements, both in isotope identification and in distinguishing compact sources from background, through the installation of optimal-filter reconstruction kernels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the ESS cryogenic system

The European Spallation Source (ESS) is a neutron science facility funded by a collaboration of 17 European countries currently under design and construction in Lund, Sweden. The centerpiece of ESS is a 2.5 GeV proton linac utilizing superconducting RF cavities operating at 2 K. In addition to cooling the SRF cavities, cryogenics is also used at ESS in the liquid hydrogen moderators surrounding the target. ESS also uses both liquid helium and liquid nitrogen in a number of the planned neutron instruments. There is also a significant cryogenic installation associated with the site acceptance testing of the ESS cryomodules. The ESS cryogenic system consists of 3 separate helium refrigeration/liquefaction plants supplying the accelerator, target moderators and instruments. An extensive cryogenic distribution system connects the accelerator cryoplant with the cryomodules. This paper describes the preliminary design of the ESS cryogenic system including the expected heat loads. Challenges associated with the required high reliability and turn-down capability will also be discussed. A unique feature of ESS is its commitment to sustainability and energy recovery. A conceptual design for recovering waste heat from the helium compressors for use in the Lund district heating system will also be described.

43 PARTICLE ACCELERATORS↗

Simulations of Two-Bunch Plasma Wakefield Accelerator Experiments at FACET

Simulation results of possible upcoming Plasma Wakefield Accelerator (PWFA) experiments at FACET are presented. In a two-bunch scenario, the second (accelerated) electron bunch can have multi-GeV energy gain and a small energy spread after less than 1 meter of propagation in a Cs plasma column.

43 PARTICLE ACCELERATORS↗

Metrology, applications and methods with high energy CT systems

The increase of Computed Tomography (CT) as an applicable metrology and Non Destructive Testing (NDT) method raises interest on developing the application fields to larger objects, which were rarely used in the past due to their requirements on the imaging system. Especially the classical X-ray generation techniques based on standard equipment restricted the applications of CT to typical material penetration lengths of only a few cm of steel. Even with accelerator technology that offers a suitable way to overcome these restrictions just the 2D radioscopy technique found a widespread application. Beside the production and detection of photons in the MeV range itself, the achievable image quality is limited using standard detectors due to the dominating absorption effect of Compton Scattering at high energies. Especially for CT reconstruction purposes these effects have to be considered on the development path from 2D to 3D imaging. Most High Energy CT applications are therefore based on line detectors shielding scattered radiation to a maximum with an increase in imaging quality but with time consuming large volume scan capabilities. In this contribution we present the High-Energy X-ray Imaging project at the Fraunhofer Development Centre for X-ray Technology with the characterization and the potential of the CT-system according to metrological and other application capabilities.

43 PARTICLE ACCELERATORS↗

Simulations of future particle accelerators: issues and mitigations

The ever increasing demands placed upon machine performance have resulted in the need for more comprehensive particle accelerator modeling. Computer simulations are key to the success of particle accelerators. Many aspects of particle accelerators rely on computer modeling at some point, sometimes requiring complex simulation tools and massively parallel supercomputing. Examples include the modeling of beams at extreme intensities and densities (toward the quantum degeneracy limit), and with ultra-fine control (down to the level of individual particles). In the future, adaptively tuned models might also be relied upon to provide beam measurements beyond the resolution of existing diagnostics. Much time and effort has been put into creating accelerator software tools, some of which are highly successful. However, there are also shortcomings such as the general inability of existing software to be easily modified to meet changing simulation needs. In this paper possible mitigating strategies are discussed for issues faced by the accelerator community as it endeavors to produce better and more comprehensive modeling tools. This includes lack of coordination between code developers, lack of standards to make codes portable and/or reusable, lack of documentation, among others.

43 PARTICLE ACCELERATORS↗

High efficiency, low cost, RF sources for accelerators and colliders

Accelerators for High Energy Physics (HEP) are large users of energy, much of it in the form of radiofrequency (RF) power to accelerate particles to very high energies. Proposed HEP projects will require even larger amounts of RF energy. Increasing concerns of the cost and availability of energy will require the HEP community to use energy as efficiently as possible. Successful transfer of HEP technology to the public and private sectors will be most effective if it is highly efficient. Historically, the HEP community has utilized available RF power sources, mainly in the form of vacuum tube technology, much of which was developed during the cold war or is otherwised used in the private sector. The private sector is moving to solid-state RF sources which do not exhibit the electrical efficiency that is needed for future HEP projects. Here we summarize the state of the development of a number of RF sources that promise efficiencies of 80% and above. We also outline future efforts that are needed to fully realize the potential of these sources.

43 PARTICLE ACCELERATORS↗

Modeling of Diamond Based Devices for Beam Diagnostics

Beamlines at new light sources, such as the National Synchrotron Light Source II will operate at flux levels beyond the saturation level of existing diagnostics, necessitating the development of new devices. Currently, there is no detector which can span the entire flux range that is possible even in a second generation light source and will become crucial for next generation light sources. One new approach is a diamond-based detector that will be able to monitor beam position, flux and timing to much better resolution. Furthermore, this detector also has linear response to flux over 11 orders of magnitude. However, the successful development of the detector requires thorough understanding and optimization of the physical processes involved. We will discuss the new modeling capabilities we have been implementing in the VORPAL 3D code to investigate the effects of charge generation due to absorption of x-ray photons, transport, and charge trapping. We will report results from VORPAL simulations on charge collection and how it depends on applied field, charge trapping, and the energy of absorbed photons.

43 PARTICLE ACCELERATORS↗