Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Annual Report on Improved Accuracy of Pu Assay of Spent Fuel Project

The objective of this work is to improve the accuracy of plutonium assay for nuclear fuel reprocessing. This work addresses such questions as: 1) How much Pu has been recovered in a reprocessing facility?; 2) Is a reprocessing operation consistent with safeguards?; and 3) How much Pu is unaccounted for in a safeguarded facility? This improved Pu accuracy will be achieved by direct measurement of Pu using monochromatic excitation and detection. These elemental measurements will not only provide direct concentration measurements of plutonium in spent fuel dissolver solution. The increased accuracy of the Pu assay addresses the heart of safeguards by providing greater accuracy and less error in the Pu measurements of these facilities. This is further achieved by using the high energy Ka line of Pu at 103.65 keV. This allows for the direct measurement of Pu through container walls such as Zircaloy tubing which is used for the cladding of nuclear fuel rods. While ultrahigh energy X-ray fluorescence (UHEXRF) has been done at synchrotron facilities, X-ray optic technology has advanced to make possible, laboratory based instrumentation to enable such high energy measurements to be done on the bench top. Such instrumentation can change the plutonium assay measurement paradigm by offering safer, more rapid and more accurate Pu measurements through container walls nondestructively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Accuracy Transistor Compact Model Calibrations

Typically, transistors are modeled by the application of calibrated nominal and range models. These models consists of differing parameter values that describe the location and the upper and lower limits of a distribution of some transistor characteristic such as current capacity. Correspondingly, when using this approach, high degrees of accuracy of the transistor models are not expected since the set of models is a surrogate for a statistical description of the devices. The use of these types of models describes expected performances considering the extremes of process or transistor deviations. In contrast, circuits that have very stringent accuracy requirements require modeling techniques with higher accuracy. Since these accurate models have low error in transistor descriptions, these models can be used to describe part to part variations as well as an accurate description of a single circuit instance. Thus, models that meet these stipulations also enable the calculation of quantification of margins with respect to a functional threshold and uncertainties in these margins. Given this need, new model high accuracy calibration techniques for bipolar junction transistors have been developed and are described in this report.

42 ENGINEERING↗

Numerical Stability and Accuracy of Temporally Coupled Multi-Physics Modules in Wind-Turbine CAE Tools

In this paper we examine the stability and accuracy of numerical algorithms for coupling time-dependent multi-physics modules relevant to computer-aided engineering (CAE) of wind turbines. This work is motivated by an in-progress major revision of FAST, the National Renewable Energy Laboratory's (NREL's) premier aero-elastic CAE simulation tool. We employ two simple examples as test systems, while algorithm descriptions are kept general. Coupled-system governing equations are framed in monolithic and partitioned representations as differential-algebraic equations. Explicit and implicit loose partition coupling is examined. In explicit coupling, partitions are advanced in time from known information. In implicit coupling, there is dependence on other-partition data at the next time step; coupling is accomplished through a predictor-corrector (PC) approach. Numerical time integration of coupled ordinary-differential equations (ODEs) is accomplished with one of three, fourth-order fixed-time-increment methods: Runge-Kutta (RK), Adams-Bashforth (AB), and Adams-Bashforth-Moulton (ABM). Through numerical experiments it is shown that explicit coupling can be dramatically less stable and less accurate than simulations performed with the monolithic system. However, PC implicit coupling restored stability and fourth-order accuracy for ABM; only second-order accuracy was achieved with RK integration. For systems without constraints, explicit time integration with AB and explicit loose coupling exhibited desired accuracy and stability.

17 WIND ENERGY↗

Image-Guided Intraoperative Assessment of Surgical Margins in Oral Cavity Squamous Cell Cancer: A Diagnostic Test Accuracy Review

The assessment of resection margins during surgery of oral cavity squamous cell cancer (OCSCC) dramatically impacts the prognosis of the patient as well as the need for adjuvant treatment in the future. Currently there is an unmet need to improve OCSCC surgical margins which appear to be involved in around 45% cases. Intraoperative imaging techniques, magnetic resonance imaging (MRI) and intraoral ultrasound (ioUS), have emerged as promising tools in guiding surgical resection, although the number of studies available on this subject is still low. The aim of this diagnostic test accuracy (DTA) review is to investigate the accuracy of intraoperative imaging in the assessment of OCSCC margins. By using the Cochrane-supported platform Review Manager version 5.4, a systematic search was performed on the online databases MEDLINE-EMBASE-CENTRAL using the keywords “oral cavity cancer, squamous cell carcinoma, tongue cancer, surgical margins, magnetic resonance imaging, intraoperative, intra-oral ultrasound”. Ten papers were identified for full-text analysis. The negative predictive value (cutoff < 5 mm) for ioUS ranged from 0.55 to 0.91, that of MRI ranged from 0.5 to 0.91; accuracy analysis performed on four selected studies showed a sensitivity ranging from 0.07 to 0.75 and specificity ranging from 0.81 to 1. Image guidance allowed for a mean improvement in free margin resection of 35%. IoUS shows comparable accuracy to that of ex vivo MRI for the assessment of close and involved surgical margins, and should be preferred as the more affordable and reproducible technique. Both techniques showed higher diagnostic yield if applied to early OCSCC (T1–T2 stages), and when histology is favorable.

60 APPLIED LIFE SCIENCES↗

An Accuracy-Maximization Approach for Claims Classifiers in Document Content Analytics for Cybersecurity

This paper presents our research approach and findings towards maximizing the accuracy of our classifier of feature claims for cybersecurity literature analytics, and introduces the resulting model ClaimsBERT. Its architecture, after extensive evaluations of different approaches, introduces a feature map concatenated with a Bidirectional Encoder Representation from Transformers (BERT) model. We discuss deployment of this new concept and the research insights that resulted in the selection of Convolution Neural Networks for its feature mapping aspects. We also present our results showing ClaimsBERT to outperform all other evaluated approaches. This new claims classifier represents an essential processing stage within our vetting framework aiming to improve the cybersecurity of industrial control systems (ICS). Furthermore, in order to maximize the accuracy of our new ClaimsBERT classifier, we propose an approach for optimal architecture selection and determination of optimized hyperparameters, in particular the best learning rate, number of convolutions, filter sizes, activation function, the number of dense layers, as well as the number of neurons and the drop-out rate for each layer. Fine-tuning these hyperparameters within our model led to an increase in classification accuracy from 76% obtained with BertForSequenceClassification’s original model to a 97% accuracy obtained with ClaimsBERT.

Ameri, Kimia (ORCID:0000000328791871)↗

A NanoSIMS 50 L Investigation into Improving the Precision and Accuracy of the 235U/238U Ratio Determination by Using the Molecular 235U16O and 238U16O Secondary Ions

A NanoSIMS 50 L was used to study the relationship between the 235U/238U atomic and 235U16O/238U16O molecular uranium isotope ratios determined from a variety of uranium compounds (UO2, UO2F2, UO3, UO2(NO3)2·6(H2O), and UF4) and silicates (NIST-610 glass and the Plesovice zircon reference materials, both containing µg/g uranium). Because there is typically a greater abundance of 235U16O+ and 238U16O+ molecular secondary ions than 235U+ and 238U+ atomic ions when uranium-bearing materials are sputtered with an oxygen primary ion beam, the goal was to understand whether use of 235U16O/238U16O has the potential for improved accuracy and precision when compared to the 235U/238U ratio. The UO2 and silicate reference materials showed the greatest potential for improved accuracy and precision through use of the 235U16O/238U16O ratio as compared to the 235U/238U ratio. For the UO2, which was investigated at a variety of primary beam currents, and the silicate reference materials, which were only investigated using a single primary beam current, this improvement was especially pronounced at low 235U+ count rates. In contrast, comparison of the 235U16O/238U16O ratio versus the 235U/238U ratio from the other uranium compounds clearly indicates that the 235U16O/238U16O ratio results in worse precision and accuracy. This behavior is based on the observation that the atomic (235U+ and 238U+) to molecular (235U16O+ and 238U16O+) secondary ion production rates remain internally consistent within the UO2 and silicate reference materials, whereas it is highly variable in the other uranium compounds. Efforts to understand the origin of this behavior suggest that irregular sample surface topography, and/or molecular interferences arising from the manner in which the UO2F2, UO3, UO2(NO3)2·6(H2O), and UF4 were prepared, may be a major contributing factor to the inconsistent relationship between the observed atomic and molecular secondary ion yields. Overall, the results suggest that for certain bulk compositions, use of the 235U16O/238U16O may be a viable approach to improving the precision and accuracy in situations where a relatively low 235U+ count rate is expected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

On the Accuracy of the ALMA Flux Calibration in the Time Domain and across Spectral Windows

A diverse array of science goals requires accurate flux calibration of observations with the Atacama Large Millimeter/submillimeter array (ALMA); however, this goal remains challenging due to the stochastic time-variability of the “grid” quasars ALMA uses for calibration. In this work, we use 343.5 GHz (Band 7) ALMA Atacama Compact Array observations of four bright and stable young stellar objects over seven epochs to independently assess the accuracy of the ALMA flux calibration and to refine the relative calibration across epochs. The use of these four extra calibrators allows us to achieve an unprecedented relative ALMA calibration accuracy of ~3%. On the other hand, when the observatory calibrator catalog is not up to date, the Band 7 data calibrated by the ALMA pipeline may have a flux calibration poorer than the nominal 10%, which can be exacerbated by weather-related phase decorrelation when self-calibration of the science target is either not possible or not attempted. We also uncover a relative flux calibration uncertainty between spectral windows of 0.8%, implying that measuring spectral indices within a single ALMA band is likely highly uncertain. We thus recommend various methods for science goals requiring high flux accuracy and robust calibration, in particular, the observation of additional calibrators combined with a relative calibration strategy, and observation of solar system objects for high absolute accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

STRAP IV - High accuracy, low drift attitude control system.

The STRAP IV attitude control system was designed, tested, and successfully launched to provide stable high accuracy pointing at nontrackable X-ray sources. On its initial flight (May 19, 1972), the STRAP IV control system updated its high accuracy, rate integrating gyros on two successive stellar targets and then maneuvered the rocket body to point the experimental payload at two separate X-ray sources and an X-ray-free background location. The third axis, which remained under the control of a coarse free gyro, was updated by a technique of successive star-target coordinate transformation to ensure the correct fine-axis azimuth alignment for the high accuracy inertial maneuvers. Pointing accuracies of 4 arc min with limit cycle stability of less than 20 arc sec peak to peak were obtained on all targets.

Shrewsberry, D. J.↗

The accuracy of far-field noise obtained by the mathematical extrapolation of near-field noise data

Results are described of an analytical study of the accuracy and limitations of a technique that permits the mathematical extrapolation of near-field noise data to far-field conditions. The effects of the following variables on predictive accuracy of the far-field pressure were examined: (1) number of near-field microphones; (2) length of source distribution; (3) complexity of near-field and far-field distributions; (4) source-to-microphone distance; and (5) uncertainties in microphone data and imprecision in the location of the near-field microphones. It is shown that the most important parameters describing predictive accuracy are the number of microphones, the ratio of source length to acoustic wavelength, (L/wavelength), and the error in location of near-field microphones. If microphone measurement and location errors are not included, then far-field pressures can be accurately predicted up to L/wavelength values of 15 using approximately 50 microphones. For maximum microphone location errors of + or - 1 cm, only an accuracy of + or - 2-1/2 db can be attained with approximately 40 microphones for the highest L/wavelength of 10.

Ahtye, W. F.↗

A study of orbit determination accuracies for future earth observatory missions

It is anticipated that global orbital accuracies of 10 meters will be required for future earth observatory missions. Results are presented of a study of the LANDSAT-1 orbit to determine position accuracies obtainable today so as to assess what future advancements are necessary to meet a 10-meter goal. Accuracies of 50 meters were determined to be achievable now from two-day tracking arcs. One-half-day arcs yield accuracies of about 30 meters. The dominant error source was found to be geopotential model uncertainty. All other systematic errors produced less than 10 meters total position error.

Bryant, W. C., Jr.↗

The accuracy of far-field noise obtained by the mathematical extrapolation of near-field noise data

Results are presented for an analytical study of the accuracy and limitations of a technique that permits the mathematical extrapolation of near-field noise data to far-field conditions. The effects of the following variables on predictive accuracy of the far-field pressure were examined: (1) number of near-field microphones; (2) length of source distribution; (3) complexity of near-field and far-field distributions; (4) source-to-microphone distance; and (5) uncertainties in microphone data and imprecision in the location of the near-field microphones. It is shown that the most important parameters describing predictive accuracy are the number of microphones, the ratio of source length to acoustic wavelength (L/lambda), and the error in location of near-field microphones. For maximum microphone location errors of plus or minus 1 cm, only an accuracy of plus or minus 2.5 dB can be attained with approximately 40 microphones for the highest L/lambda of 10.

Ahtye, W. F.↗

Future timing accuracy requirements and procedures for data processing

Timing accuracy requirements for satellite experiment data are discussed. Although time accuracies of 100 milliseconds were sufficient when OSO-3, 4, 5 were launched in the mid-60s, time accuracies of 100 microseconds are necessary for OSO-8, HEAO-A, and Seasat, and it is thought likely that accuracies of 10 microseconds will become routine in the 1980s. An approach to the problem of identifying the sources of spacecraft timing errors - from the onboard counters to the final tagging of data - is considered.

Smith, G. A.↗

Single-axis attitude determination accuracy

This paper extends the analysis of attitude determination accuracy introduced at the 1975 American Astronautical Society/American Institute of Aeronautics and Astronautics (AAS/AIAA) Astrodynamics Conference. It contains more generalized expressions, new geometrical relations, and additional applications. A complete set of attitude accuracy equations for both arc-length (portion of a great circle) and rotation-angle (dihedral angle) measurements are presented. These expressions can then be applied to determine the geometrical conditions under which a specified accuracy can be achieved by using either the attitude or a selected reference-vector direction as the independent variable. Representative applications to attitude determination accuracy studies and launch window analyses are discussed. The clear physical interpretation and straightforward graphical procedures greatly simplify mission analysis, maneuver planning, hardware configuration studies, and interpretation of results.

Chen, L. C.↗

Navigation accuracy analyses for two comet rendezvous missions using ion drive

Two cometary missions, making use of the solar electric propulsion system, have recently been considered for launches in the mid to late 1980's. This paper presents navigation accuracy analysis results for the rendezvous portions of these missions, the target bodies being Comet Tempel 2 and Comet Tuttle-Giacobini-Kresak. Orbit determination and guidance accuracies are presented for the baseline navigation strategies, along with the results of a number of sensitivity studies involving parameters such as data frequencies, data accuracies, ion drive thrust vector errors, comet emphemeris uncertainties, time lags associated with data processing and command sequence generation, and certain guidance law parameters. The accuracies obtained are, in some respects, significantly better than the results of previous solar electric propulsion comet rendezvous studies.

Wood, L. J.↗

Preliminary study of GPS orbit determination accuracy achievable from worldwide tracking data

The improvement in the orbit accuracy if high accuracy tracking data from a substantially larger number of ground stations is available was investigated. Observations from 20 ground stations indicate that 20 cm or better accuracy can be achieved for the horizontal coordinates of the GPS satellites. With this accuracy, the contribution to the error budget for determining 1000 km baselines by GPS geodetic receivers would be only about 1 cm.

Larden, D. R.↗

Development and evaluation of a Kalman-filter algorithm for terminal area navigation using sensors of moderate accuracy

Translational state estimation in terminal area operations, using a set of commonly available position, air data, and acceleration sensors, is described. Kalman filtering is applied to obtain maximum estimation accuracy from the sensors but feasibility in real-time computations requires a variety of approximations and devices aimed at minimizing the required computation time with only negligible loss of accuracy. Accuracy behavior throughout the terminal area, its relation to sensor accuracy, its effect on trajectory tracking errors and control activity in an automatic flight control system, and its adequacy in terms of existing criteria for various terminal area operations are examined. The principal investigative tool is a simulation of the system.

Kanning, G.↗

Preliminary study of GPS orbit determination accuracy achievable from worldwide tracking data

The improvement in the orbit accuracy if high accuracy tracking data from a substantially larger number of ground stations is available was investigated. Observations from 20 ground stations indicate that 20 cm or better accuracy can be achieved for the horizontal coordinates of the GPS satellites. With this accuracy, the contribution to the error budget for determining 1000 km baselines by GPS geodetic receivers would be only about 1 cm. Previously announced in STAR as N83-14605

Larden, D. R.↗

Comparative accuracies of AVHRR and MSS data used for Level I land cover classifications

The capabilities of the Advanced Very High Resolution Radiometer (AVHRR) for land cover mapping were investigated by comparing the accuracy of land cover information for the Washington, DC area derived from NOAA-7 AVHRR data with that from Landsat Multispectral Scanner (MSS) data. Unsupervised Level I land cover classifications were performed for MSS and AVHRR data sets collected on July 11, 1981. A detailed accuracy assessment was conducted based on ground truth delineated on six USGS 7.5 minute series topographic maps. Preliminary results produced overall land cover classification accuracies of 75.6 percent and 76.1 percent for AVHRR and MSS, respectively. While the accuracies for predominant categories such as agriculture, forest, and urban were similar for both sensors, discrimination of the less commonly occurring categories such as barren, wetland, and water was improved with the MSS data set. The AVHRR, however, performed as well as or better than the MSS in classifying large homogeneous areas. The application of AVHRR data with its lower processing cost and more frequent worldwide coverage appears promising for global land cover mapping.

Gervin, J. C.↗