Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Disruption event characterization and forecasting in tokamaks

Disruption prediction and avoidance is a critical need for next-step tokamaks, such as ITER. Disruption Event Characterization and Forecasting (DECAF) research fully automates analysis of tokamak data to determine chains of events that lead to disruptions and to forecast their evolution allowing sufficient time for mitigation or complete avoidance of the disruption. Disruption event chains related to local rotating or global magnetohydrodynamic (MHD) modes and vertical instability are examined with warnings issued for many off-normal physics events, including density limits, plasma dynamics, confinement transitions, and profile variations. Along with Greenwald density limit evaluation, a local radiative island power balance theory is evaluated and compared to the observation of island growth. Automated decomposition and analysis of rotating tearing modes produce physical event chains leading to disruptions. A total MHD state warning model comprised of 15 separate criteria produces a disruption forecast about 180 ms before a standard locked mode detector warning. Single DECAF event analyses have begun on KSTAR, MAST, and NSTX/-U databases with thousands of shot seconds of device operation using from 0.5 to 1 × 10 6 tested sample times per device. An initial multi-device database comparison illustrates a highly important result that plasma disruptivity does not need to increase as βN increases. Global MHD instabilities, such as resistive wall modes (RWMs), can give the briefest time period of warning before disruption compared to other physics events. In an NSTX database with unstable RWMs, the mode onset, loss of boundary and current control, and disruption event warnings are found in all cases and vertical displacement events are found in 91% of cases. An initial time-dependent reduced physics model of kinetic RWM stabilization created to forecast the disruption chain predicts instability 84% of the time for experimentally unstable cases with a relatively low false positive rate. Instances of the disruption event chain analysis illustrate dynamics including H–L back transitions for rotating MHD and global RWM triggering events. Furthermore, disruption warnings are issued with sufficient time before the disruption (on transport timescales) to potentially allow active profile control for disruption avoidance, active mode control, or mitigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation

This paper develops a controller for a grid-forming (GFM) inverter that is capable of operating as either a GFM or grid-feeding source that can improve the operation of a microgrid during on-off grid transitions through use of a novel synchronization approach. Furthermore, this controller avoids use of a phase-locked loop (PLL) and the inverter is able to synchronize with the grid with self-generated voltage and frequency. This prevents the inverter from replicating any grid voltage disturbances in its output—a key disadvantage of many grid-connected inverters that use a PLL. To enable fast synchronization, active synchronization control is adopted both during inverter start-up and microgrid reconnection operation and a method of coordinating synchronization of the inverter with a microgrid controller and grid interconnection circuit breaker is presented. Simulation results for multiple microgrid transition operations and unplanned islanding events demonstrate that the developed non-PLL grid-connected GFM inverter controller and synchronization method are effective in synchronizing the inverter and microgrid to the grid, avoiding phase jump during microgrid transition operation, and improving microgrid islanding transients versus a traditional configuration.

27 ARPA - Advanced Research Projects Agency-Energy↗

Active Fault Current Limiting Control for Half-Bridge MMC in HVDC Systems

DC faults of MMC can result in a significantly large fault current due to the discharge of submodule capacitors. The fault current not only risks damaging the MMC but also demands a considerable breaking capacity from the dc circuit breaker (DCCBs). This paper introduces two novel active fault current limiting methods (AFCLs), namely virtual impedance-based and energy control-based AFCL. The first method utilizes circulating current feedforward, which introduces a virtual arm impedance to suppress the rate of rise of the fault current. Meanwhile, the second method relies on the control of the internally stored energy of the MMC to automatically minimize the number of submodules that discharge during a dc-side fault. Therefore, both the dc-side current and the MMC arm current can be effectively suppressed after the occurrence of the fault. The proposed methods do not require fault detection and their response is proportional to the rate of rise in the fault current. Simulation case studies are presented to demonstrate the proposed methods.

active current limiting control↗

Design of a 3.4-MW wind turbine with integrated plasma actuator-based load control

Historically, cost reduction in wind energy has been accomplished by increasing hub heights and rotor diameters to capture more energy per turbine. The growth in rotor and turbine costs with increasing turbine sizes is also driven by the additional structure that must be added to withstand unsteady aerodynamic loads caused by turbulence, gusts, wind shear, misaligned yaw, upwind wakes, and the tower shadow. In this paper, we present a holistic design solution to integrate active load control using a controllable Gurney flap based on plasma actuators. We illustrate the design solution for a land-based 3.4-MW wind turbine rotor. Comparisons to a baseline reference 3.4-MW wind turbine show significant load reduction (15–18% DEL reduction for flap-wise blade root moments), rotor mass reduction (5–8%), and LCOE reduction (1.16–3.11%). To achieve these results, a comprehensive sequential-iterative design procedure is introduced to integrate the controllable Gurney flap into the turbine design and to drive the design solution toward the best LCOE reduction solution. Results are presented for mapping fatigue load reductions into cost reductions. In addition, an evaluation of active load control extended from Region-III to also include Region-II showed a further 34% reduction in DEL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerosol‐Correlated Cloud Activation for Clean Conditions in the Tropical Atlantic Boundary Layer During LASIC

Abstract Aerosol measurements during the DOE ARM Layered Atlantic Smoke Interactions with Clouds (LASIC) campaign were used to quantify the differences between clean and smoky cloud condensation nuclei (CCN) budgets. Accumulation‐mode particles accounted for ∼70% of CCN at supersaturations <0.3% in clean and smoky conditions. Aitken‐mode particles contributed <20% and sea‐spray‐mode particles <10% at supersaturations <0.3%, but at supersaturations >0.3% Aitken particles contributions increased to 30%–40% of clean CCN. For clean conditions, the Hoppel minimum diameter was correlated to the accumulation‐mode number concentration, indicating aerosol‐correlated cloud activation was controlling the lower diameter cutoff for which particles serve as CCN. For smoky conditions, the contributions of Aitken particles increase and the correlation of cloud activation to accumulation‐mode particles is masked by the lower‐hygroscopicity smoke. These results provide the first multi‐month in situ quantitative constraints on the role of aerosol number size distributions in controlling cloud activation in the tropical Atlantic boundary layer.

54 ENVIRONMENTAL SCIENCES↗

Olefin metathesis over supported MoO x catalysts: influence of the oxide support

Here, a series of supported MoO x catalysts on different oxide supports (Al2O3, TiO2, ZrO2, SiO2) were synthesized and investigated for propylene metathesis, characterized with in situ spectroscopies (DRIFTS, Raman, UV-vis) and chemically probed with propylene-TPSR-MS, propylene-TPSR-IR, and ethylene/2-butene titration. Under dehydrated conditions at monolayer coverage or maximum surface dispersion, the surface MoO x sites are present as a mixture of isolated di-oxo (O=) 2 Mo(–O–Al) 2 and oligomeric mono-oxo O=Mo(–O–Al) 4/5 sites on Al 2 O 3 , primarily oligomeric mono-oxo O=Mo(–O–Ti) 4/5 on TiO 2 , isolated di-oxo (O=) 2 Mo(–O–Zr) 2 and oligomeric mono-oxo O=Mo(–O–Zr) 4/5 on ZrO 2 , and isolated di-oxo (O=) 2 Mo(–O–Si) 2 on SiO 2 . The bridged (S 2 -OH) and tri-coordinated (S 3 -OH) anchoring surface hydroxyls of the oxide supports with strong support cation electronegativity control the activation and number of active surface MoO x sites at low temperatures (<100 °C). The isolated anchoring surface hydroxyls (S-OH) of the oxide supports with strong support cation electronegativity control the activation and number of active surface MoO x sites at high temperatures (>350 °C). Olefin metathesis by the more redox active supported MoO x /TiO 2 and MoO x /ZrO 2 catalysts is retarded by the formation of stable surface acetone and acetate species that block olefin adsorption. The oxide supports are potent ligands that tune the activation and surface chemistry of the surface MoOx sites for olefin metathesis. This is the first time that the influence of oxide supports on the activation and surface chemistry of supported MoO x sites has been systematically examined.

02 PETROLEUM↗

Nanoporous Iridium Nanosheets for Polymer Electrolyte Membrane Electrolysis

The growth of the hydrogen economy is predicated on advancements in electrochemical energy technologies, with water electrolysis as a key component to the technological portfolio. Much of the focus on anode catalyst development for polymer electrolyte membrane water electrolyzers (PEMWE) is centered on activity as controlled by compositional and morphological impacts on reactant/intermediate/product adsorption. However, the effectiveness of this strategy is found to be limited upon integration of these materials into PEMWE membrane electrode assemblies (MEA). Regardless of catalyst activity, the combination of electrode inhomogeneity, ionomer integration, and high density of oxide-oxide interfaces yields significant performance losses associated with poor catalytic electrode conductivity. Here many of these limitations are addressed through the development of a unique catalyst morphology composed of nanoporous Ir nanosheets (npIr(x)-NS) that exhibit high catalytic activity for the anodic oxygen evolution reaction and superior electrode electronic conductivity in comparison to a commercial IrO2 nanoparticle catalyst. The utility of the npIr(x)-NS is demonstrated through incorporation into PEMWE MEAs where their performance exceeds that of commercial catalyst coated membranes at loadings as low as 0.06 mg(Ir) cm(-2) while exhibiting a negligible loss in performance following 50 000 accelerated stress test cycles.

Polymer Electrolyte Membrane Electrolysis↗

ACTIVE

The Automated Control Testbed for Integration, Verification, and Emulation (ACTIVE) framework is a software platform designed to support the optimized operation and management of a wide range of building types. It enables the development, testing, and validation of diverse control strategies, including AI-based, rule-based, and model-based approaches. The platform facilitates a seamless transition from simulation-based evaluation of control strategies to real-world field validation and deployment. ACTIVE supports the full building management lifecycle, encompassing data acquisition and management, system monitoring, optimized control, adaptive learning services, device dispatch and coordination, as well as advanced analytics and visualization. Together, these capabilities provide an integrated environment for improving building performance, operational efficiency, reducing energy cost, and reliability.

Smith, Robert [Oak Ridge National Laboratory (ORNL↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Temperature Evolution of the Activation Barriers Leads to Meyer−Neldel Rules for Structural Relaxation and Transport in Polymers

Understanding activation barriers controlling structural relaxation in glass-forming liquids, molecular transport, and ionic conductivity in amorphous polymers is a grand challenge of fundamental scientific and materials engineering interest across disciplines. Over decades, intriguing but puzzling empirical correlations between the elementary time scale of activated barrier crossing and the apparent Arrhenius activation energy, the so-called Meyer−Neldel (MN) rules, have been discovered in diverse liquids and glasses. Here, in this study, we formulate and successfully apply a new experimental analysis and an explicitly dynamical theoretical framework which provides an understanding of the origin, validity, and failure of such correlations, that bridge and unify the three fields of structural relaxation, molecular transport, and ionic conductivity in liquids and quenched glasses. Distinct quasi-universal laws are predicted in equilibrated liquids and nonequilibrium glasses, consistent with experiments. Our analysis reveals that even if the relaxation appears Arrhenius over a limited temperature range, the physical activation barrier is generally temperature-dependent in polymeric systems even below glass transition temperature. In addition, we show that the approximate validity of classical MN rules hinges on a linear temperature dependence of this barrier and the temperature range probed in experiments. Our findings are relevant for controlling the activation barrier in functional soft polymeric materials relevant to molecular separations, barrier coatings, and charge transport, and also provide new constraints on the theoretical understanding of the mechanism underlying slow activated dynamics in glass-forming condensed matter.

Meyer-Neldel rules↗

Cell-Free Systems Biology: Characterizing Central Metabolism of Clostridium thermocellum with a Three-Enzyme Cascade Reaction

Genetic approaches have been traditionally used to understand microbial metabolism, but this process can be slow in nonmodel organisms due to limited genetic tools. An alternative approach is to study metabolism directly in the cell lysate. This avoids the need for genetic tools and is routinely used to study individual enzymatic reactions but is not generally used to study systems-level properties of metabolism. Here we demonstrate a new approach that we call “cell-free systems biology”, where we use well-characterized enzymes and multienzyme cascades to serve as sources or sinks of intermediate metabolites. This allows us to isolate subnetworks within metabolism and study their systems-level properties. To demonstrate this, we worked with a threeenzyme cascade reaction that converts pyruvate to 2,3-butanediol. Although it has been previously used in cell-free systems, its pH dependence was not well characterized, limiting its utility as a sink for pyruvate. We showed that improved proton accounting allowed better prediction of pH changes and that active pH control allowed 2,3-butanediol titers of up to 2.1 M (189 g/L) from acetoin and 1.6 M (144 g/L) from pyruvate. The improved proton accounting provided a crucial insight that preventing the escape of CO 2 from the system largely eliminated the need for active pH control, dramatically simplifying our experimental setup. We then used this cascade reaction to understand limits to product formation in Clostridium thermocellum, an organism with potential applications for cellulosic biofuel production. We showed that the fate of pyruvate is largely controlled by electron availability and that reactions upstream of pyruvate limit overall product formation.

09 BIOMASS FUELS↗

Regional Real-Time PV Spinning Reserve Estimator

Curtailed photovoltaic (PV) generation is a zero-marginal-cost spinning reserve that can be used for a number of active power control services. Unlike traditional spinning reserve providers, however, i.e., fossil-fueled generators, which have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate knowledge of the PV PHL is essential. It ensures that enough headroom is reserved by the PV plants to deliver the award services in real time and informs feasible dispatch decisions made by the market operator. To tackle this challenge, a novel reference-control grouping-based PV plant reserve estimation method has been proposed by the National Renewable Energy Laboratory under past projects funded by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office. The estimation method separates inverters within a plant into two groups: a control group and a reference group. While the reference group is reserved to operate at its PHL, the control group can be curtailed to provide the grid services. Real-time outputs from the reference inverters are used to estimate the PHL for the whole plant based on the ratio between capacities of the reference group and of the plant. This work further enhances the methodology by (1) improving the model accuracy through machine learning; (2) automating the reference inverter selection through correlation analysis; (3) considering estimation look-ahead windows; and (4) applying to regional spinning reserve estimation. Significant performance improvement has been observed based on real-world data collected by CAISO, Southern Company, and Terabase Energy. Compared with the original scaling method, the newly proposed machine learning-based approach reduces the estimation errors by 30% and 13% at the plant level and region level, respectively. Results obtained from this project are intended to be used by grid operators, market operators, balancing authorities, and PV plant owners and operators to facilitate PV participation in ancillary service markets. Regulators, policymakers, and system planners can also consider the results of this work in their decision-making processes. In addition to the performance improvement on the existing reference-control based grouping method, we also investigated how the variability of PV generation from a single PV inverter can be used to represent the variability of PV generation at the plant level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active Divertor Heat Flux Control using Impurity Powder Dropper

Divertor plasma-facing components (PFCs) in a tokamak are typically designed to withstand average steady-state heat loads of about 5–10 MW/m 2 , a limit that applies to both solid and liquid lithium (LL) PFCs. Exceeding these design values can result in surface damage to tungsten PFCs or excessive lithium (Li) evaporation in liquid lithium divertor (LLD) PFCs. Since exceeding the divertor heat load limits has serious consequences, it is therefore prudent to develop a tool to reduce the divertor heat load and bring the heat load to within the design limit without affecting the plasma performance. Active low Z impurity injection such as Li has been suggested as a potential solution to mitigate excess heat flux as suggested previously, given that non-coronal radiation can be quite large ~ 20–30 MJ per mole of injected Li. Li is considered desirable for reducing the edge neutral recycling helping to improve plasma energy confinement. In this paper, we model the Impurity Power Dropper (IPD) to investigate its potential of divertor heat flux control. The IPD is typically located at the top of the tokamak device and uses a vertical drift tube of a few meters. In the 2 m drift tube case, the IPD powder is accelerated to ~ 6 m/sec before reaching the plasma with the upper divertor configuration, matching the condition for the in-board side pellet injection case. By modeling the IPD geometry we determined the IPD powder deposition profile, and thus the non-coronal radiation and ionization profiles in time as well. From the enhanced radiation power loss, it is therefore possible to reduce the divertor heat load using the divertor simulation code. In conclusion, the IPD divertor heat flux control can be tested in the facilities with IPD including ST-40, DIII-D, EAST, WEST and NSTX-U.

Active lithium injection↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 99% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows: Preprint

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 1.6% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Decentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration: Preprint

This paper introduces a fully decentralized control strategy that allows for individualized active and reactive power control of H-bridge inverters connected in series. After formulating a model of the system power flows, we outline a communications-free approach where each inverter can act on independent commands. Inverter-level feedback is accomplished locally via a measurement of current flowing through the stack. A key feature is the lack of any centralized control routines or phase-locked loop. In this framework, the reactive power control loops achieve voltage synchronization among the converters and the grid, and the active power control loops modulate the terminal voltage amplitudes that influence power delivery. Furthermore, pole placement via state feedback is used to ensure stability of voltage synchronization while also enabling tracking of bidirectional power commands. Simulations are presented to validate the proposed approach.

communication-free modular converter control↗

Carbon flowers as electrocatalysts for the reduction of oxygen to hydrogen peroxide

Small-scale and decentralized production of H 2 O 2 via electrochemical reduction of oxygen is of great benefit, especially for sanitization, air and water purification, as well as for a variety of chemical processes. The development of low-cost and high-performance catalysts for this reaction remains a key challenge. Carbon-based materials have drawn substantial research efforts in recent years due to their advantageous properties, such as high chemical stability and high tunability in active sites and morphology. Deeper understanding of structure–activity relationships can guide the design of improved catalysts. We hypothesize that mass transport to active sites is of great importance, and herein we use carbon materials with unique flower-like superstructures to achieve high activity and selectivity for O 2 reduction to H 2 O 2 . The abundance of nitrogen active sites controlled by pyrolysis temperature resulted in high catalytic activity and selectivity for oxygen reduction reaction (ORR). The flower superstructure showed higher performance than the spherical nanoparticles due to greater accessibility to the active sites. Chemical activation improves the catalysts’ performances further, driving the production of H 2 O 2 to a record-setting rate of 816 mmol·g cat -1 ·h -1 using a bulk electrolysis setup. In conclusion, this work demonstrates the development of a highly active catalyst for the sustainable production of H 2 O 2 through rational design and synthetic control. The understanding from this work provides further insight into the design of future carbon-based electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗