Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analytic functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Constructing monotones for quantum phase references in totally dephasing channels

Restrictions on quantum operations give rise to resource theories. Total lack of a shared reference frame for transformations associated with a group G between two parties is equivalent to having, in effect, an invariant channel between the parties and a corresponding superselection rule. The resource associated with the absence of the reference frame is known as ''frameness'' or ''asymmetry.'' We show that any entanglement monotone for pure bipartite states can be adapted as a pure-state frameness monotone for phase-invariant channels [equivalently U(1) superselection rules] and extended to the case of mixed states via the convex-roof extension. As an application, we construct a family of concurrence monotones for U(1) frameness for general finite-dimensional Hilbert spaces. Furthermore, we study ''frameness of formation'' for mixed states analogous to entanglement of formation. In the case of a qubit, we show that it can be expressed as an analytical function of the concurrence analogously to the Wootters formula for entanglement of formation. Our results highlight deep links between entanglement and frameness resource theories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superfluid-to-Mott-insulator transition in the one-dimensional Bose-Hubbard model for arbitrary integer filling factors

We study the quantum phase transition between the superfluid and the Mott insulator in the one-dimensional (1D) Bose-Hubbard model. Using the time-evolving block-decimation method, we numerically calculate the tunneling splitting of two macroscopically distinct states with different winding numbers. From the scaling of the tunneling splitting with respect to the system size, we determine the critical point of the superfluid-to-Mott-insulator transition for arbitrary integer filling factors. We find that the critical values versus the filling factor in 1D, 2D, and 3D are well approximated by a simple analytical function. We also discuss the condition for determining the transition point from a perspective of the instanton method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radial oscillations of color superconducting self-bound quark stars

We investigate the effect of the color-flavor locking pairing pattern on the adiabatic radial oscillations of pure self-bound quark stars using an equation of state in the framework of the MIT bag model. We integrate the equations of relativistic radial oscillations to determine the fundamental and the first excited oscillation modes for several parameterizations of the equation of state. For low mass stars we find that the period of the fundamental mode is typically {approx}0.1 ms and has a small dependence on the parameters of the equation of state. For large mass stars the effect of color-flavor locking is related to the rise of the maximum mass with increasing {Delta}. As for unpaired quark stars, the period of the fundamental mode becomes divergent at the maximum mass but now the divergence is shifted to large masses for large values of the pairing gap {Delta}. As a consequence, the oscillation period is strongly affected by color superconductivity for stars with M > or approx. 1.5 M{sub {center_dot}}. We fit the period of the fundamental mode with appropriate analytical functions of the gravitational redshift of the star and the pairing gap {Delta}. We further discuss the excitation and damping of the modes and their potential detectability during violent transient phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Eigenvector Continuation with Subspace Learning

A common challenge faced in quantum physics is finding the extremal eigenvalues and eigenvectors of a Hamiltonian matrix in a vector space so large that linear algebra operations on general vectors are not possible. There are numerous efficient methods developed for this task, but they generally fail when some control parameter in the Hamiltonian matrix exceeds some threshold value. In this Letter we present a new technique called eigenvector continuation that can extend the reach of these methods. The key insight is that while an eigenvector resides in a linear space with enormous dimensions, the eigenvector trajectory generated by smooth changes of the Hamiltonian matrix is well approximated by a very low-dimensional manifold. We prove this statement using analytic function theory and propose an algorithm to solve for the extremal eigenvectors. We benchmark the method using several examples from quantum many-body theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating the Environmental Impacts of Connected and Automated Vehicles: Potential Shortcomings of a Binned-Based Emissions Model

In addition to providing safety and mobility benefits, Connected and Automated Vehicles (CAVs) have the potential to reduce fuel consumption and emissions. As new CAV applications are developed, it is valuable to estimate these potential environmental benefits, typically using vehicle activity data and emissions models. To date, most researchers in the U.S. have used the MOVES vehicle emissions model, developed and maintained by the U.S. Environmental Protection Agency (EPA). However, because MOVES uses a binning approach, it is likely underestimating the true energy and emissions savings that occur when CAV applications smooth traffic flow. To illustrate this problem, we measure and model the fuel consumption and CO 2 emissions for a real-world CAV application: Eco-Approach and Departure (EAD) at signalized intersections. Real-world measurements are compared to a MOVES-based estimate, as well as to an estimate provided by the physical-based Comprehensive Modal Emissions Model (CMEM). Results show that MOVES consistently underestimates the energy and emissions benefits of the CAV application, primarily since the bin sizes in MOVES are too large to catch the nuances of traffic smoothing. On the other hand, CMEM provided a more accurate energy and emissions estimate, primarily since it uses analytical functions to model emissions and does not suffer from the same binning problem.

42 ENGINEERING↗

Design and Analysis of Multifidelity Finite Element Simulations

Abstract The numerical accuracy of finite element analysis (FEA) depends on the number of finite elements used in the discretization of the space, which can be varied using the mesh size. The larger the number of elements, the more accurate the results are. However, the computational cost increases with the number of elements. In current practice, the experimenter chooses a mesh size that is expected to produce a reasonably accurate result, and for which the computer simulation can be completed in a reasonable amount of time. Improvements to this approach have been proposed using multifidelity modeling by choosing two or three mesh sizes. However, mesh size is a continuous parameter, and therefore, multifidelity simulations can be performed easily by choosing a different value for the mesh size for each of the simulations. In this article, we develop a method to optimally find the mesh sizes for each simulation and satisfy the same time constraints as a single or a double mesh size experiment. A range of different mesh sizes used in the proposed method allows one to fit multifidelity models more reliably and predict the outcome when meshes approach infinitesimally small, which is impossible to achieve in actual simulations. We illustrate our approach using an analytical function and a cantilever beam finite element analysis experiment.

Engineering↗

Dose rate profile surrounding a repository

The focus of this research was to analyze the dose rate profile around a waste repository using Monte Carlo techniques. Dose rates at various heights and distances were analyzed outside of the waste repository using MCNPX [1]. The heights measured extended the height of the building and the distances varied between 0 and 22 m away from the waste repository. The simulation data were fitted by smooth analytical functions for different height levels and distances, such that vertical and horizontal dose rates as functions of source-detector distance were achieved. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A novel method to evaluate gamma camera rotational uniformity and sensitivity variation

An alternative to the conventional method of performing the AAPM Report 52 rotational uniformity and sensitivity test has been developed. In contrast to the conventional method in which a Co-57 sheet source is fastened to the collimator, this new point-source method acquires the images intrinsically using a Tc-99m point source placed near the isocenter of gantry rotation. As with the conventional method, the point-source method acquires 5x10{sup 6} count flood images at four distinct gantry positions to calculate the maximum sensitivity variation (MSV)--a quantitative metric of rotational uniformity and sensitivity variation. The point-source method incorporates corrections for the decay of Tc-99m between acquisitions, the curvature in the image intensity due to variation in photon flux across the detector from a near-field source, and the source-to-detector distance variations between views. The raw point-source images were fitted with an analytic function in order to compute curvature- and distance-corrected images prior to analysis. Five independent MSV measurements were performed using both conventional and point-source methods on a single detector of a dual-headed SPECT system to estimate the precision of each method. The precision of the point-source method was further investigated by performing ten independent measurements of MSV on six different detectors. Correlation between the MSV calculated by the two methods was investigated by performing the test on nine different detectors using both methods. Different levels of sensitivity variations were also simulated on four detectors to generate 40 additional paired points for correlation analysis. The effect of the total image counts on the MSV estimated with the new method was evaluated by acquiring image sequences with 5x10{sup 6}, 10x10{sup 6}, and 20x10{sup 6} count images. The MSV calculated using the conventional and point-source methods exhibited a high degree of correlation and consistency with equivalence. The precision of the point-source method (0.145%) is lower than the conventional method (0.04%) but sufficient to test MSV. No statistically significant dependence of MSV with the point-source method on the total image counts over a range of (5-20)x10{sup 6} counts was observed. Curvature correction of the images prior to the generation of difference images renders images more conducive to qualitative inspection for structured, nonrandom patterns. The advantages of the new methodology are that multiple detectors of a gamma camera can be evaluated simultaneously which substantially reduces the time required for MSV testing and the reduced risk of accidental damage to the collimators and patient proximity detection system from having to mount a sheet source on each of the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration

Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilities of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions. Conclusion: LOOP can cooperate with any fitting routine functioning as a “robust fit”. In addition, it can be set as a benchmark for film-dose calibration fitting performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗

SU-F-T-129: Impact of Radial Fluctuations in RBE for Therapeutic Proton Beams

Purpose: To evaluate the off axis relative biological effectiveness (RBE) for actively scanned proton beams and determine if a constant radial RBE can be assumed. Methods: The PHITS Monte Carlo code paired with a microscopic analytical function was used to determine probability distribution functions of the lineal energy in 0.3µm diameter spheres throughout a water phantom. Twenty million primary protons were simulated for a 0.6cm diameter pencil beam. Beam energies corresponding to Bragg Peak depths of 50, 100, 150, 200, 250, and 300mm were used and evaluated transversely every millimeter and radially for annuli of 1.0, 2.0, 3.0, 3.2, 3.4, 3.6, 4.0, 5.0, 10.0, 15.0, 20.0 and 25.0mm outer radius. The acquired probability distributions were reduced to dose-mean lineal energies and applied to the modified microdosimetric kinetic model, for human submandibular gland (HSG) cells, to calculate relative biological effectiveness (RBE) compared to 60Co beams at the 10% survival threshold. Results: RBE was generally seen to increase as distance from the central axis (CAX) increased. However, this increase was only seen in low dose regions and its overall effects on the transverse biological dose remains low. In the entrance region of the phantom (10mm depth), minimum and maximum calculated RBEs varied between 15.22 and 18.88% for different energies. At the Bragg peak, this difference ranged from 3.15 to 26.77%. Despite these rather large variations the dose-weighted RBE and the CAX RBE varied by less than 0.14% at 10mm depth and less than 0.16% at the Bragg peak. Similarly small variations were found at all depths proximal of the Bragg peak. Conclusion: Although proton RBE does vary radially, its overall effect on biological dose is minimal and the use of a radially constant RBE in treatment planning for scanned proton beams would not produce large errors.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-02: Analytical Stopping Power and Range Parameterization for Therapeutic Energy Intervals

Purpose: To develop a simple, analytic parameterization of stopping power and range, which covers a wide energy interval and is applicable to many species of projectile ions and target materials, with less than 15% disagreement in linear stopping power and 1 mm in range. Methods: The new parameterization was required to be analytically integrable from stopping power to range, and continuous across the range interval of 1 µm to 50 cm. The model parameters were determined from stopping power and range data for hydrogen, carbon, iron, and uranium ions incident on water, carbon, aluminum, lead and copper. Stopping power and range data was taken from SRIM. A stochastic minimization algorithm was used to find model parameters, with 10 data points per energy decade. Additionally, fitting was performed with 2 and 26 data points per energy decade to test the model’s robustness to sparse Results: 6 free parameters were sufficient to cover the therapeutic energy range for each projectile ion species (e.g. 1 keV – 300 MeV for protons). The model agrees with stopping power and range data well, with less than 9% relative stopping power difference and 0.5 mm difference in range. As few as, 4 bins per decade were required to achieve comparable fitting results to the full data set. Conclusion: This study successfully demonstrated that a simple analytic function can be used to fit the entire energy interval of therapeutic ion beams of hydrogen and heavier elements. Advantages of this model were the small number (6) of free parameters, and that the model calculates both stopping power and range. Applications of this model include GPU-based dose calculation algorithms and Monte Carlo simulations, where available memory is limited. This work was supported in part by a research agreement between United States Naval Academy and Louisiana State University: Contract No N00189-13-P-0786. In addition, this work was accepted for presentation at the American Nuclear Society Annual Meeting 2016.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-H-BRA-09: Application of a Modified Microdosimetric-Kinetic Model to Analyze Relative Biological Effectiveness of Ions Relevant to Light Ion Therapy Using the Particle Heavy Ion Transport System

Purpose: To evaluate the dose and biological effectiveness of various ions that could potentially be used for actively scanned particle therapy. Methods: The PHITS Monte Carlo code paired with a microscopic analytical function was used to determine probability distribution functions of the lineal energy in 0.3µm diameter spheres throughout a water phantom. Twenty million primary particles for 1H beams and ten million particles for 4He, 7Li, 10B, 12C, 14N, 16O, and 20Ne were simulated for 0.6cm diameter pencil beams. Beam energies corresponding to Bragg peak depths of 50, 100, 150, 200, 250, and 300mm were used and evaluated transversely every millimeter and radially in annuli with outer radius of 1.0, 2.0, 3.0, 3.2, 3.4, 3.6, 4.0, 5.0, 10.0, 15.0, 20.0 and 25.0mm. The acquired probability distributions were reduced to dose-mean lineal energies and applied to the modified microdosimetric kinetic model for five different cell types to calculate relative biological effectiveness (RBE) compared to 60Co beams at the 10% survival threshold. The product of the calculated RBEs and the simulated physical dose was taken to create biological dose and comparisons were then made between the various ions. Results: Transversely, the 10B beam was seen to minimize relative biological dose in both the constant and accelerated dose change regions, proximal to the Bragg Peak, for all beams traveling greater than 50mm. For the 50mm beam, 7Li was seen to provide the most optimal biological dose profile. Radially small fluctuations (<4.2%) were seen in RBE while physical dose was greater than 1% for all beams. Conclusion: Even with the growing usage of 12C, it may not be the most optimal ion in all clinical situations. Boron was calculated to have slightly enhanced RBE characteristics, leading to lower relative biological doses.

60 APPLIED LIFE SCIENCES↗

On bouncing solutions in non-local gravity

A non-local modified gravity model with an analytical function of the d’Alembert operator, is considered. This model has been recently proposed as a possible way of resolving the singularities problem in cosmology. We present exact bouncing solution, which is simpler compared to the already known one in this model, in the sense it does not require an additional matter to satisfy all gravitational equations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Risk-Averse Control of Fractional Diffusion with Uncertain Exponent

In this paper, we introduce and analyze a new class of optimal control problems constrained by elliptic equations with uncertain fractional exponents. We utilize risk measures to formulate the resulting optimization problem. We develop a functional analytic framework, study the existence of solution and rigorously derive the first-order optimality conditions. Additionally, we employ a sample-based approximation for the uncertain exponent and the finite element method to discretize in space. Further, we prove the rate of convergence for the optimal risk neutral controls when using quadrature approximation for the uncertain exponent and conclude with illustrative examples.

finite element method↗

Enhancing the hunt for new phenomena in dijet final states using anomaly detection filters at the high-luminosity large Hadron Collider

In the realm of dijet searches in high-energy physics, a significant challenge has emerged: with experiments producing more and more data, the traditional methods of using analytic functions to describe dijet mass spectra start to fail. Here, to address this, we suggest the application of an anomaly detection approach to eliminate less interesting background events based on event final states. This method not only bypasses the limitations of conventional background models but also significantly enhances our ability to detect potential signals of new physics. Through simulations that mimic the conditions of the upcoming high-luminosity large Hadron collider, we demonstrate the strength and efficiency of this approach in dealing with large data volumes. The integration of unsupervised machine learning into our experimental framework paves the way for a promising avenue to unveil hidden physics discoveries within the overwhelming influx of data.

47 OTHER INSTRUMENTATION↗

Scalable Reasoning System (SRS)

SRS is a web-based and mobile toolkit for information visualization and collaboration. It includes server-side components in the form of web services that provide analytical functions such as data clustering and temporal analysis. The SRS client is accessed via a web browser and uses asynchronous javascript and XML (AJAX) to interact with and visualize the results of these web services. Users of SRS can query data sources that are connected to the SRS backend, and query results are presented in the form of coordinated visual displays in a web browser that depict temporal, topical, and spatial relationships in the results. SRS also includes an early stage graphical reasoning diagram interface that helps analysts express and test hypotheses. This software was developed with funding from the Science and Technology Directorate of the U.S. Department of Homeland Security.

Pike, William↗