Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atmospheric relative humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Analysis of Rapidly Developing Low Cloud Ceilings in a Stable Environment

This report describes the work done by the Applied Meteorology Unit (AMU) in developing a database of days that experienced rapid (< 90 minutes) low cloud formation in a stable atmosphere, resulting in ceilings at the Shuttle Landing Facility (TTS) that violated Space Shuttle Flight Rules (FR). The meteorological conditions favoring the rapid formation of low ceilings include the presence of any inversion below 8000 ft, high relative humidity beneath the inversion, and a clockwise turning of the winds from the surface to the middle troposphere (approx. 15000 ft). The AMU compared and contrasted the atmospheric and thermodynamic conditions between days with rapid low ceiling formation and days with low ceiling resulting from other mechanism. The AMU found that the vertical wind profile is the probable discerning factor between the rapidly-forming ceiling days and other low ceiling days at TTS. Most rapidly-developing low ceiling days had a clockwise turning of the winds with height, whereas other low ceiling days typically had a counter-clockwise turning of the winds with height or negligible vertical wind shear. Forecasters at the Space Meteorology Group (SMG) issue 30 to 90 minute forecasts for low cloud ceilings at TTS to support Space Shuttle landings. Mission verification statistics have shown ceilings to be the number one forecast challenge. More specifically, forecasters at SMG are concerned with any rapidly developing clouds ceilings below 8000 ft in a stable, capped thermodynamic environment, Therefore, the AMU was tasked to examine archived events of rapid stable cloud formation resulting in ceilings below 8000 ft, and document the atmospheric regimes favoring this type of cloud development. The AMU examined the cool season months of November to March during the years of 1993-2003 for days that had low-level inversions and rapid, stable low cloud formation that resulted in ceilings violating the Space Shuttle FR. The AMU wrote and modified existing code to identify inversions from the morning Cape Canaveral, FL rawinsonde (XMR) during the cool season and output pertinent sounding information. They parsed all days with cloud ceilings below 8000 ft at TTS, forming a database of possible rapidly-developing low ceiling events. Days with precipitation or noticeable fog bum-off situations were excluded from the database. Only the daytime hours were examined for possible ceiling development events since low clouds are easier to diagnose with visible satellite imagery. Follow-on work would expand the database to include nighttime cases, using a special enhancement of the infrared imagery for identifying areas of low clouds. The report presents two sample cases of rapidly-developing low cloud ceilings. These cases depict the representative meteorological and thermodynamic characteristics of such events. The cases also illustrate how quickly the cloud decks can develop, sometimes forming in 30 minutes or less. The report also summarizes the composite meteorological conditions for 20 event days with rapid low cloud ceiling formation and 48 non-events days consisting of advection or widespread low cloud ceilings. The meteorological conditions were quite similar for both the event and non-event days, since both types of days experienced low cloud ceilings. Both types of days had a relatively moist environment beneath the inversion based below 8000 ft. In the 20 events identified, de onset of low ceilings occurred between 1200-1800 UTC in every instance. The distinguishing factor between the event and non-event days appears to be the vertical wind profile in the XMR sounding. Eighty-five percent of the event days had a clockwise turning of the winds with height in the lower to middle troposphere whereas 83% of the non-events had a counter-clockwise turning of the winds with height or negligible vertical wind shear. A clockwise turning of the winds with height indicates a warm advection regime, which supports large-scale rising motn and possible cloud formation. Meanwhile, a counter-clockwise turning of the winds with height indicates cold advection or sinking motion in a post-cold frontal environment.

Wheeler, Mark M.↗

Tower Water-Vapor Mixing Ratio Value-Added Product Report

The purpose of the Tower Water-Vapor Mixing Ratio (TWRMR) value-added product (VAP) is to calculate water-vapor mixing ratios at the 25-meter and 60-meter levels of the meteorological tower and also report best-estimate temperature, relative humidity, and pressure measurements at the 2-meter, 25-meter, and 60-meter levels at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) Central Facility. Because there are no barometric pressure sensors at the 25-meter and 60-meter levels on the tower, the hypsometric equation is used along with surface pressure values from the surface meteorological instrumentation (MET), the surface meteorological observation system (SMOS), or the temperature, humidity, wind, and pressure system (THWAPS) to derive barometric pressures at those altitudes (Ritsche 2008, 2011a, 2011b). After this is done, water-vapor mixing ratio can be calculated directly.

54 ENVIRONMENTAL SCIENCES↗

The atmosphere of Mars - Resources for the exploration and settlement of Mars

This paper describes methods of processing the Mars atmosphere to supply water, oxygen and buffer gas for a Mars base. Existing life support system technology is combined with innovative methods of water extraction, and buffer gas processing. The design may also be extended to incorporate an integrated greenhouse to supply food, oxygen and water recycling. It is found that the work required to supply one kilogram of an argon/nitrogen buffer gas is 9.4 kW-hr. To extract water from the dry Martian atmosphere can require up to 102.8 kW-hr per kilogram of water depending on the relative humidity of the air.

Meyer, T. R.↗

Tropospheric Ozone Over a Tropical Atlantic Station in the Northern Hemisphere: Paramaribo, Surinam (6 deg N, 55 deg W)

We present an analysis of 2.5 years of weekly ozone soundings conducted at a new monitoring station in Paramaribo, Surinam (6 deg N,55 deg W). This is currently one of only three ozone sounding stations in the northern hemisphere (NH) tropics, and the only one in the equatorial Atlantic region. Paramaribo is part of the Southern Hemisphere ADditional Ozone Sounding program (SHADOZ). Due to its position close to the equator, the Inter Tropical Convergence Zone (ITCZ) passes over Paramaribo twice per year, which results in a semi-annual seasonality of many parameters including relative humidity and ozone. The dataset from Paramaribo is used to: (1) evaluate ozone variability relative to precipitation, atmospheric circulation patterns and biomass burning; (2) contrast ozone at the NH equatorial Atlantic with that at nearby southern hemisphere (SH) stations Natal (6 deg S,35 deg W) and Ascension (8 deg S,14 deg W); (3) compare the seasonality of tropospheric ozone with a satellite-derived ozone product: Tropical Tropospheric Ozone Columns from the Modified Residual method (MR-TTOC). We find that Paramaribo is a distinctly Atlantic station. Despite its position north of the equator, it resembles nearby SH stations during most of the year. Transport patterns in the lower and middle troposphere during February and March differ from SH stations, which leads to a seasonality of ozone with two maxima. MR-TTOC over Paramaribo does not match the observed seasonality of ozone due to the use of a SH ozone sonde climatology in the MR method. The Paramaribo ozone record is used to suggest an improvement for northern hemisphere MR-TTOC retrievals. We conclude that station Paramaribo shows unique features in the region, and clearly adds new information to the existing SHADOZ record.

Peters, W.↗

Analysis of Upper Air, Ground and Remote Sensing Data for the Atlas Field Campaign in San Juan, Puerto Rico

The general climate of the island of Puerto Rico is dominated by the easterly trade winds from the Atlantic Ocean, and during synoptically calm days by the topographic and local land surface characteristics [1]. The urban canopy of the metropolitan area of San Juan, capital city of the Island, may introduce a new microclimate that changes the characteristics of the low atmosphere and interacts with the other microclimates already present in the island. The primitive land cover and land use (LCLU) of the metropolitan area of San Juan was composed by broadleaf trees, moist soils, and very dense vegetation in general. The urban LCLU changes the balance for the mass, momentum and energy between the bottom boundary and the lower atmosphere, creating different climate conditions over urban and rural regions. Some of these differences are low relative humidity and high temperatures observed in urban areas when compared to rural areas. These in turn produces a convective circulation over the urban areas, a phenomenon compared to the sea and land breezes, commonly known as heat islands (UHI). Factors that contribute to the formation of the UHI are anthropogenic heat sources, aerosols from pollutants, fast water canalization due to the presence of buildings and streets, among others. The comparison between urban and rural climates is the most common approach to analyze the UHI. These contrasts are larger in clear and calm conditions and tend to disappear in cloudy and windy weather. The UHI was recognized in the early 1950 s as closed isotherms that separates the city from the general temperature field [2]. The impact of the urban LCLU in San Juan, Puerto Rico, was quantified calculating the difference between historical data sets for the air temperature over an identified urban area and a rural area dT(U-R). The analysis of the climatological data revealed that a UHI exists in the metropolitan area of San Juan, Puerto Rico. The data reveals a permanent urban heat island effect present in the SJMA during the year, which is increasing at a rate of 0.41oC/decade. These findings encouraged the planning and execution of an intense field campaign in February 2004 referred as the ATLAS San Juan mission. The focus of the remaining of this report is the analysis of the data for this field campaign.

Gonzalez-Cruz, Jorge E.↗

Improved Apparatus for Testing Monoball Bearings

A desk-sized apparatus for testing monoball bearings and their lubricants offers advantages, relative to prior such apparatuses, of (1) a greater degree of automation and (2) capability of operation under wider and more realistic ranges of test conditions. The ranges of attainable test conditions include load from 100 to greater h than 50,000 lb (445 to greater than 2.22 x 10(exp 5) N), resisting torque up to 30,000 lb-in. (approximately equal to 3,390 N-m), oscillating rotation through an angle as large as 280 degrees, and oscillation frequency from 0 to 6 Hz. With addition of some components and without major modification of the apparatus, it is also possible to perform tests under environmental conditions that include temperature from -320 to 1,000 F (-196 to +538 C), relative humidity from 0 to 100 percent, and either air at ambient pressure, high vacuum, or an atmosphere of monatomic oxygen. In the apparatus (see Figure 1), a monoball bearing specimen is driven in oscillating rotation by a hydraulic rotary actuator through a series of shafts, one of which incorporates a torque meter and one of which is a flexible coupling. The torque meter measures the resisting torque; the flexible coupling accommodates misalignment, wear, and compression of the specimen and ensures equal loading on opposite sides of the monoball. Not shown in the figure is an angular-position sensor that is used for measuring the angle of rotation of the shafts.

Hall, Phillip B.↗

The atmosphere of Uranus - Results of radio occultation measurements with Voyager 2

The Uranian atmosphere is investigated on the basis of S-band and X-band occultation observations (including measurements of Doppler frequency perturbations) obtained during the Voyager 2 encounter with Uranus in January 1986. The data are presented in extensive tables and graphs and characterized in detail. The atmosphere is assumed to have an H2/He abundance ratio of about 85/15, but also to contain small amounts of CH4 at above-cloud relative humidity 30 percent, cloud-base relative humidity 78 percent, and below-cloud mixing ratio 2.3 percent by number density. Other parameters estimated include magnetic-field rotation period 17.24 h, 1-bar equatorial radius 25,559 + or - 4 km, polar radius 24,973 + or - 20 km, equatorial acceleration of gravity 8.69 + or - 0.01 m/sec sq, and atmospheric temperature 76 + or - 2 K (assuming 85 + or - 3 percent H2).

Lindal, G. F.↗

A-Train Data Depot: Integrating and Visualizing Atmospheric Measurements Along the A-Train Tracks

The succession of US and international satellites that follow each other, seconds to minutes apart, across the local afternoon equator crossing is called the ATrain. The A-Train consists of the following satellites, in order of equator crossing: OCO, EOS Aqua, CloudSat, CALIPSO, PARASOL, and EOS Aura. Flying in such formation increases the number of observations, validates observations, and enables coordination between science observations, resulting in a more complete virtual science platform (Kelly, 2000) The goal of this project is to create the first ever A-Train virtual data portal/center, the A-Train Data Depot, to process, archive, access, visualize, analyze and correlate distributed atmosphere measurements from various A-Train instruments along A-Train tracks. The A-Train Data Depot (ATDD) will enable the free movement of remotely located A-Train data so that they are combined to create a consolidated vertical view of the Earth s Atmosphere along the A-Train tracks. Once the infrastructure of the ATDD is in place, it will be easily evolved to serve data from all A-Train data measurements: one stop shopping. The innovative approach of analyzing and visualizing atmospheric profiles along the platforms track (i.e., time) will be accommodated by reusing the GSFC Atmospheric Composition Data and Information Services Center (ACDISC) visualization and analysis tool, GIOVANNI, existing data reduction tools, on-line archwing for fast data access, and Cooperative Institute for Research in the Atmosphere (CRA) data co-registration tools. Initial measurements utilized include CALIPSO lidar backscatter, CloudSat radar reflectivity, clear air relative humidity, water vapor and temperature from AIRS, and cloud properties and aerosols from both MODIS. This will be followed by associated measurements from MLS, OMI, HIRDLS, and TES. Given the independent nature of instrument/platform development, the ATDD project has been met with many interesting challenges that, once resolved, will provide a much greater understanding of the relative flight dynamics and data co-registration of the suite of A-Train instruments, thus greatly increasing the accuracy of A-Train data analysis. Some of these challenges will be discussed. The project s resulting visualizations and analysis illustrate the importance of managing data so that measurements from various missions can be combined to enhance the understanding of the atmosphere. A-Train data management coordination, as performed here, is extremely significant in facilitating the A-Train science of clouds, precipitation, aerosol and chemistry.

Kempler, Steven↗

Multiscale Interactions between Local Short- and Long-Term Spatio-Temporal Mechanisms and Their Impact on California Wildfire Dynamics

California has experienced a surge in wildfires, prompting research into contributing factors, including weather and climate conditions. This study investigates the complex, multiscale interactions between large-scale climate patterns, such as the Boreal Summer Intraseasonal Oscillation (BSISO), El Niño Southern Oscillation (ENSO), and the Pacific Decadal Oscillation (PDO) and their influence on moisture and temperature fluctuations, and wildfire dynamics in California. The combined impacts of PDO and BSISO on intraseasonal fire weather changes; the interplay between fire weather index (FWI), relative humidity, vapor pressure deficit (VPD), and temperature in assessing wildfire risks; and geographical variations in the relationship between the FWI and climatic factors within California are examined. The study employs a multi-pronged approach, analyzing wildfire frequency and burned areas alongside climate patterns and atmospheric conditions. The findings reveal significant variability in wildfire activity across different climate conditions, with heightened risks during specific BSISO phases, La-Niña, and cool PDO. The influence of BSISO varies depending on its interaction with PDO. Temperature, relative humidity, and VPD show strong predictive significance for wildfire risks, with significant relationships between FWI and temperature in elevated regions (correlation, r > 0.7, p ≤ 0.05) and FWI and relative humidity along the Sierra Nevada Mountains (r ≤ -0.7, p ≤ 0.05).

54 ENVIRONMENTAL SCIENCES↗

Dynamics of Liquid–Liquid Phase Separation in Submicrometer Aerosol

Nanoscale materials, when compared to their bulk components, possess unique properties. In particular, shifts in phase transitions can occur for submicron particles. For instance, small particles do not undergo the process of liquid-liquid phase separation (LLPS). LLPS has applications in emulsions such as Janus particles, controllable morphology to create drug-rich phases during drug delivery, and is often observed in atmospheric aqueous aerosol particles. In atmospheric particles, LLPS is tracked as a function of particle water activity, which is equivalent to the relative humidity (RH) at equilibrium. We probed three organic/inorganic aerosol systems in the range of RH over which phase separation occurs (SRH). Our findings indicate that SRH for submicron aerosol particles is lower than for micron-sized droplets. These findings show that it may be necessary to update the representation of phase transitions in aerosol particles in climate models. The vast majority of organic/inorganic aerosol particles have submicron diameters, and a decrease in SRH for submicron particles indicates that the current estimation of phase separated aerosols may be overestimated. Furthermore, understanding the properties of LLPS at the nanoscale can provide key parameters to describe these systems and may lead to better control of phase separation in submicron particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GreenSight WxHive Unmanned Aerial System (UAS) Atmospheric Profiling at the SGP Central Facility

The GreenSight WxHive is capable of flying multiple nanodrones simultaneously to provide spatiotemporal atmospheric sampling. During the WH2yMSIE campaign, the WxHive would fly up to 5 nanodrones at once, performing profiling within the planetary boundary layer over the ARM SGP Central Facility site. The measurements provided by the WxHive include latitude, longitude, altitude, pressure, temperature, humidity, and wind speed and direction. See the attached WeatherHive User Guide for more details about the instrument and measurements.

Air pressure↗

Scattering and absorption from poly-dispersed aerosols

Results from numerical computations of the diffuse sky radiances and degree of polarization are given. These results were obtained by solving the equation of radiative transfer in the formulation of Eschelbach. In these computations, multiple scattering and absorption by aerosol particles were considered. In addition, results from experimental measurements of the complex refractive index of aerosol samples at different relative humidities are presented. From the radiation flux divergences which were computed based on the determined properties of atmospheric aerosol particles, atmospheric heating rates were derived which were found to be comparable to the heating rates by water vapor.

Bullrich, K.↗

Assessing the Convective Environment over Irrigated and Non-Irrigated Land Use with Land-Atmosphere Coupling Metrics: Results from GRAINEX

Land use land cover change affects weather and climate. This paper quantifies land-atmosphere interactions over irrigated and non-irrigated land uses during the Great Plains Irrigation Experiment (GRAINEX). Three coupling metrics were used to quantify some land-atmosphere interactions as it relates to convection. They include: the Convective Triggering Potential (CTP) and Low-Level Humidity Index (HI low ), and the Lifting Condensation Level (LCL) Deficit. These metrics were calculated from the rawinsonde data obtained from the Integrated Sounding Systems (ISS) for Rogers Farm and York Airport along with soundings launched from the Doppler on Wheels (DOW) sites. Each metric was categorized by Intensive Observation Period (IOP), cloud cover, and time of day.

Daniel Whitesel↗

Phase Transitions in Organic and Organic/Inorganic Aerosol Particles

The phase state of aerosol particles can impact numerous atmospheric processes, including new particle growth, heterogeneous chemistry, cloud condensation nucleus formation, and ice nucleation. In this article, the phase transitions of inorganic, organic, and organic/inorganic aerosol particles are discussed, with particular focus on liquid-liquid phase separation (LLPS). The physical chemistry that determines whether LLPS occurs, at what relative humidity it occurs, and the resultant particle morphology is explained using both theoretical and experimental methods. The known impacts of LLPS on aerosol processes in the atmosphere are discussed. Finally, potential evidence for LLPS from field and chamber studies is presented. By understanding the physical chemistry of the phase transitions of aerosol particles, we will acquire a better understanding of aerosol processes, which in turn impact human health and climate.

Chemistry↗

Some analyses of the variability of atmospheric parameters at low altitudes significant for aircraft flyover noise measurements.

A number of special radiosondes were examined to study the statistical variabilities of atmospheric parameters on a time and space scale commensurate with aircraft flyover noise measurements. Particular emphasis is placed on those aspects of the data which relate to the temporal variabilities of the temperature and humidity profiles. It is found that during the late morning hours, continuous surface measurements and measurements of airport tower levels are sufficient to monitor the layer of the atmosphere in which the largest variabilities occur.

Chang, D. T.↗

Independent temperature and humidity control of a precooled desiccant air cooling system with proportional and fuzzy logic + proportional based controllers

Providing room comfort quickly by using less energy in cooling systems is important both in terms of efficiency and environment. In this study, independent temperature/humidity control strategies are designed for precooled desiccant based evaporative cooling system to provide room comfort quickly with less energy. Therefore, the speed controls of the system's actuators become important depending on the room, cooler and atmosphere conditions. The mathematical models are obtained to determine the relation between voltages of actuators and the variations in the room's temperature and humidity. After that, new control strategies are developed based on Proportional and Fuzzy+Proportional techniques and the control performance is increased by adding extra modes to the operation of the actuators. The effects of the control techniques on the cooling performance and energy consumption were investigated for different cases. It has been observed that the room temperature and relative humidity reach the set values in a short time for both techniques and are successfully kept at these values under the disturbances. By using Fuzzy+Proportional controller, the robustness of the cooler increases due to more precisely adjustment of controller's parameter depending the system conditions. Finally, both control strategies provide more than 20% energy savings compared to the traditional ON/OFF control.

42 ENGINEERING↗

Entrainment, Detrainment, and Dilution of Dry and Moist Atmospheric Thermals

Here this study examines the entrainment, detrainment, and dilution of dry and moist (cloud) atmospheric thermals in large-eddy simulations. In a neutrally stable environment (with respect to dry dynamics), moist thermals have an increase in radius R with thermal height z t (α ≡ dR/dz t ) about 4 times smaller compared to dry thermals when density stratification is considered and ~2.4 times smaller without density stratification (i.e., applying the Boussinesq approximation). An analytic expression relating α to several dimensionless parameters is derived from the thermal impulse–circulation relation to clarify the factors impacting α. This expression shows that the difference in buoyancy structure between moist and dry thermals, with buoyancy concentrated in the central cores of moist thermals owing to latent heating, explains their smaller spreading rates. Individual contributions of entrainment and detrainment are analyzed using a direct parcel-based approach in the simulations. Moist thermals have similar fractional detrainment but much smaller fractional entrainment rates compared to dry thermals, consistent with the differences in α. Despite having smaller α, moist thermals are similarly dilute (quantified by a passive tracer) as dry thermals because of their greater mixing efficiency with the environment. Thus, moist thermals are substantially dilute but expand much less in size/volume as they rise compared to dry thermals. The α values for moist thermals in (dry) neutral and statically stable environments are similar, but fractional entrainment and especially detrainment rates are greater in the stable environment. Large detrainment rates are associated with a breakdown of the broader thermal vortex ring structure, especially with low environmental relative humidity, attributed in part to evaporation and buoyancy reversal.

54 ENVIRONMENTAL SCIENCES↗

Updraft Width Modulates Ambient Atmospheric Controls on Convective Cloud Depth

Abstract The depth of convective clouds affects vertical transport of atmospheric constituents, influencing downstream weather and climate. Atmospheric controls on the maximum depth reached by moist convection are investigated with radar‐tracked convective cells tagged with sounding‐derived atmospheric parameters from a field campaign in central Argentina. Regression analyses show that narrow (<12‐km diameter) and wide (>16‐km diameter) cell depths respond to disparate factors, where cell areas are defined using composite reflectivity signatures. Undiluted lifted parcel indices including convective available potential energy (CAPE) and level of neutral buoyancy (LNB) are top predictors of wide cell maximum depth while mid‐tropospheric relative humidity is the top predictor of narrow cell maximum depth. Because narrow cells are more numerous than wide cells, the overall outcome of the full cell population does not strongly correlate with CAPE and LNB conditions. Tracked cells and atmospheric conditions in a simulation with 3‐km grid spacing covering the field campaign produce similar results to those observed. Narrow cells that are relatively deep have a cooler and moister mid‐troposphere with weaker free tropospheric subsidence, while relatively deep wide cells have much warmer and moister lower tropospheric conditions. These atmospheric differences are present 1 hr before cell initiation at both a fixed observing site and variable cell initiation locations. Simulated narrow cell maximum equivalent potential temperature decreases with height at a rate similar to the ambient vertical gradient, causing these cells to fall short of their LNB and supporting the view that entrainment‐driven dilution is a dominant control on their depth.

54 ENVIRONMENTAL SCIENCES↗