Search NASA⌕ Search

SEARCH · Search NASA

Results for “BETA DECAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. CUORE uses a cryogenic array of 988 TeO 2 calorimeters operated at ~10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. Further, we demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy-dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

47 OTHER INSTRUMENTATION↗

CUORE opens the door to tonne-scale cryogenics experiments

The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution – comparable to semiconductor detectors – and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. In this work, a brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffusion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the scintillation region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions

NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. Furthermore, the electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel application of neutrinos to evaluate U.S. nuclear weapons performance

There is a growing realization that neutrinos can be used as a diagnostic tool to better understand the inner workings of a nuclear weapon. Robust estimates demonstrate that an Inverse Beta Decay (IBD) neutrino scintillation detector built at the Nevada Test Site with a 1000-ton active target mass at a standoff distance of 500 m would detect thousands of antineutrino events per nuclear test. This would provide less than 4% statistical error on the measured antineutrino rate and 5% error on antineutrino energy. Extrapolating this to an error on the test device explosive yield requires knowledge from evaluated nuclear databases, non-equilibrium fission rates, and assumptions on internal neutron fluxes. Initial calculations demonstrate that the total number of neutrinos emitted per fission in the first 10 3 s after a short pulse of 239 Pu fission is about a factor of two less than that from Pu fissioning under steady state conditions. Furthermore, there are significant energy spectral differences as a function of time after the pulse that must be considered. These and other model dependencies will be discussed in the paper. In the absence of nuclear weapons testing, many of the technical and theoretical challenges of a full nuclear test could be mitigated with a low cost smaller scale 20 ton fiducial mass IBD demonstration detector placed near a pulsed reactor. Potential reactors include the Texas A&M University TRIGA 1 GW–10 ms pulsed facility or the Sandia Annular Core Research Reactor. The short duty cycle and repeatability of pulses would provide critical real environment testing and measurements, which would be valuable for planning a possible real test shot in the future. Furthermore, the antineutrino rate as a function of time data would provide unique constraints on fission databases and model assumptions. Finally, there are impactful science drivers such as sensitive searches for ∼1 eV 2 sterile neutrinos and ∼MeV scale axions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ion Manipulation from Liquid Xe to Vacuum: Ba-Tagging for a nEXO Upgrade and Future 0 νββ Experiments

Neutrinoless double beta decay (0𝜈𝛽𝛽) provides a way to probe physics beyond the Standard Model of particle physics. The upcoming nEXO experiment will search for 0𝜈𝛽𝛽 decay in 136 Xe with a projected half-life sensitivity exceeding 10 28 years at the 90% confidence level using a liquid xenon (LXe) Time Projection Chamber (TPC) filled with 5 tonnes of Xe enriched to ∼90% in the 𝛽𝛽-decaying isotope 136 Xe. In parallel, a potential future upgrade to nEXO is being investigated with the aim to further suppress radioactive backgrounds and to confirm 𝛽𝛽-decay events. This technique, known as Ba-tagging, comprises extracting and identifying the 𝛽𝛽-decay daughter 136 Ba ion. One tagging approach being pursued involves extracting a small volume of LXe in the vicinity of a potential 𝛽𝛽-decay using a capillary tube and facilitating a liquid-to-gas phase transition by heating the capillary exit. The Ba ion is then separated from the accompanying Xe gas using a radio-frequency (RF) carpet and RF funnel, conclusively identifying the ion as 136 Ba via laser-fluorescence spectroscopy and mass spectrometry. Simultaneously, an accelerator-driven Ba ion source is being developed to validate and optimize this technique. The motivation for the project, the development of the different aspects, along with the current status and results, are discussed here.

a-tagging↗

Tritiated Sulfur Hexafluoride Disposition Strategies

Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.

07 ISOTOPE AND RADIATION SOURCES↗

Plasma instabilities dominate radioactive transients magnetic fields: the self-confinement of leptons in Type Ia and core-collapse supernovae, and kilonovae

The light curves of radioactive transients, such as supernovae and kilonovae, are powered by the decay of radioisotopes, which release high-energy leptons through $\beta ^+$ and $\beta ^-$ decays. These leptons deposit energy into the expanding ejecta. As the ejecta density decreases during expansion, the plasma becomes collisionless, with particle motion governed by electromagnetic forces. In such environments, strong or turbulent magnetic fields are thought to confine particles, though the origin of these fields and the confinement mechanism have remained unclear. Using fully kinetic particle-in-cell (PIC) simulations, we demonstrate that plasma instabilities can naturally confine high-energy leptons. These leptons generate magnetic fields through plasma streaming instabilities, even in the absence of pre-existing fields. The self-generated magnetic fields slow lepton diffusion, enabling confinement, and transferring energy to thermal electrons and ions. Our results naturally explain the positron trapping inferred from late-time observations of thermonuclear and core-collapse supernovae. Furthermore, they suggest potential implications for electron dynamics in the ejecta of kilonovae. We also estimate synchrotron radio luminosities from positrons for Type Ia supernovae and find that such emission could only be detectable with next-generation radio observatories from a Galactic or local-group supernova in an environment without any circumstellar material.

instabilities↗

Modern Muon Physics: Selected Issues

The muon was discovered almost hundred years ago, but still remains largely a mystery. For a long time, the only difference between a muon and an electron was the approximately 200 times greater mass of the muon. However, with the later discovery of the charm quantum number, the muon played a decisive role in the formulation of the Standard Model of elementary particles, determining together with muon neutrino and the strange s and the charm c quarks the second generation of particles of this model. The equality of the reaction constant of muon decay with the constant of the vector interaction of beta-decay played a decisive role in the formulation of the conservation of the vector current (CVC) of the weak interaction of elementary particles. Processes involving muons testified in favor of the partial conservation of the axial current of weak interaction (PCAC), that is, one pion exchange in the interaction of the lepton and hadron currents. It was the muon that gave a rise to hopes of creating an alternative energy source within the framework of Muon Catalyzed Fusion (μCF). The possible realization of this process in the future as the intensity of muon beams increases can revolutionired energy supply. Nuclear fission by muons and the study of heavy-nucleus mesoatoms introduced muon physics into several separate branches of physical research.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Lepton Number Violation in 136 Xe and 134 Xe Decay

The EXO-200/nEXO group at Stony Brook University led by Krishna Kumar searched for neutrinoless double beta decay of 134 Xe and 136 Xe via participation in the final phase of the EXO-200 experiment and calibration pre-R&D for the next generation nEXO concept. On EXO-200, we carried out an improved analysis in the search for 134 Xe using data from Phase-II running. On nEXO, we completed a paper on our first phase of measurements demonstrating the feasibility of using photoelectricity from a gold photocathode to produce controlled amounts of charged clusters in liquid xenon. This has set the stage to develop a new test stand to evaluate the stability of a gold photocathode in order to explore the sensitivity of this method to monitor long electron lifetimes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hybrid analysis of radiative corrections to neutron decay with current algebra and effective field theory

We introduce a useful framework for high-precision studies of the neutron beta decay by merging the current algebra description and the fixed-order effective field theory calculation of the electroweak radiative corrections to the neutron axial form factor. We discuss the advantages of this hybrid method and show that it only requires a minimal amount of lattice QCD inputs to achieve a 10 –4 theory accuracy for the Standard Model prediction of the neutron lifetime and the axial-to-vector coupling ratio λ, both important to the search for physics beyond the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved determination of the 𝛽−‾‾𝜈𝑒 angular correlation coefficient 𝑎 in free neutron decay with the 𝑎⁢SPECT spectrometer

We report on a precise measurement of the electron-antineutrino angular correlation (𝑎 coefficient) in free neutron beta decay from the 𝑎⁢SPECT experiment. The 𝑎 coefficient is inferred from the recoil energy spectrum of the protons which are detected in 4⁢𝜋 by the 𝑎⁢SPECT spectrometer using magnetic adiabatic collimation with an electrostatic filter. Data are presented from a 100-day run at the Institut Laue Langevin in 2013. The sources of systematic errors are considered and included in the final result. We obtain 𝑎=−0.10430⁢(84) which is the most precise measurement of the neutron 𝑎 coefficient to date. From this, the ratio of axial vector to vector coupling constants is derived giving |𝜆|=1.2677⁢(28).

Beck, Marcus↗

Absorption of fermionic dark matter by nuclear targets

Absorption of fermionic dark matter leads to a range of distinct and novel signatures at dark matter direct detection and neutrino experiments. We study the possible signals from fermionic absorption by nuclear targets, which we divide into two classes of four Fermi operators: neutral and charged current. In the neutral current signal, dark matter is absorbed by a target nucleus and a neutrino is emitted. This results in a characteristically different nuclear recoil energy spectrum from that of elastic scattering. The charged current channel leads to induced $\beta$ decays in isotopes which are stable in vacuum as well as shifts of the kinematic endpoint of $ \beta$ spectra in unstable isotopes. To confirm the possibility of observing these signals in light of other constraints, we introduce UV completions of example higher dimensional operators that lead to fermionic absorption signals and study their phenomenology. Most prominently, dark matter which exhibits fermionic absorption signals is necessarily unstable leading to stringent bounds from indirect detection searches. Nevertheless, we find a large viable parameter space in which dark matter is sufficiently long lived and detectable in current and future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for neutrinoless β-plus-EC decay of 120 Te with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale cryogenic experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than 130 Te. In this work we describe a search for neutrinoless positron-emitting electron capture (β + EC ) decay in 120 Te with a total TeO 2 exposure of 355.7 kg yr, corresponding to 0.2405 kg yr of 120 Te. Albeit 0νββ with two final-state electrons represents the most promising channel, the emission of a positron and two 511-keV γ 's make 0νβ + EC decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of 3.4 × 10 22 yr at 90% credibility interval (C.I.). After unblinding we find no evidence of 0νβ + EC signal and set a 90% C.I. Bayesian lower limit of 2.9 × 10 22 yr on 120 Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative study of He 6 β -decay based on different similarity-renormalization-group evolved chiral interactions

We report on a study of the Gamow-Teller matrix element contributing to ${}^6$He $\beta$-decay with similarity renormalization group (SRG) versions of momentum- and configuration-space two-nucleon interactions. These interactions are derived from two different formulations of chiral effective field theory ($\chi$EFT) -- without and with the explicit inclusion of $\Delta$-isobars. We consider evolution parameters $\Lambda_{\rm SRG}$ in the range between 1.2 and 2.0 fm$^{-1}$ and, for the $\Delta$-less case, also the unevolved (bare) interaction. The axial current contains one- and two-body terms, consistently derived at tree level (no loops) in the two distinct $\chi$EFT formulations we have adopted here. The ${}^6$He and ${}^6$Li ground-state wave functions are obtained from hyperspherical-harmonics (HH) solutions of the nuclear many-body problem. In $A\,$=$\,6$ systems, the HH method is limited at present to treat only two-body interactions and non-SRG evolved currents. Our results exhibit a significant dependence on $\Lambda_{\text{SRG}}$ of the contributions associated with two-body currents, suggesting that a consistent SRG-evolution of these is needed in order to obtain reliable estimates. We also show that the contributions from one-pion-exchange currents depend strongly on the model (chiral) interactions and on the momentum- or configuration-space cutoffs used to regularize them. These results might prove helpful in clarifying the origin of the sign difference recently found in No-Core-Shell-Model and Quantum Monte Carlo calculations of the ${}^6$He Gamow-Teller matrix element.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rare multinucleon decays with the full data sets of the M AJORANA D EMONSTRATOR

The M AJORANA D EMONSTRATOR was an ultra-low-background experiment designed for neutrinoless double-beta decay (0⁢𝜈⁢𝛽⁢𝛽) investigation in 76 Ge . Located at the Sanford Underground Research Facility in Lead, South Dakota, the D EMONSTRATOR utilized modular high-purity Ge detector arrays within shielded vacuum cryostats, operating deep underground. The arrays, with a capacity of up to 40.4 kg (27.2 kg enriched to ∼88% in 76 Ge ), have accumulated the full data set, totaling 64.5 kg yr of enriched active exposure and 27.4 kg yr of exposure for natural detectors. Here, our updated search improves previously explored three-nucleon decay modes in Ge isotopes, setting new partial lifetime limits of 1.83 × 10 26 yr (90% confidence level) for 76 Ge (𝑝⁢𝑝⁢𝑝) → 73 Cu 𝑒 + ⁢𝜋 + ⁢𝜋 + and 76 Ge (𝑝⁢𝑝⁢𝑛) → 73 Zn 𝑒 + ⁢𝜋 + . The partial lifetime limit for the fully inclusive triproton decay mode of 76 Ge is found to be 2.1×10 25 yr. Furthermore, we have updated limits for corresponding multinucleon decays.

baryon & lepton number symmetries↗

Weak Transitions in Light Nuclei

Nuclei are used for high-precision tests of the Standard Model and for studies of physics beyond the Standard Model. Without a thorough understanding of nuclei, we will not be able to meaningfully interpret the growing body of experimental data nor will we be able to disentangle new physics signals from underlying nuclear effects. This calls for accurate calculations of nuclear structure and reactions. In this work, we focus on electroweak decays in nuclei with mass number A ≤ 10 and report on ab initio Quantum Monte Carlo calculations of reduced matrix elements entering beta decays and electron captures in nuclei with mass number A ≤ 10. The many-body wave functions are calculated using selected Norfolk two- and three-nucleon potential models and associated one- and two-body axial currents at tree-level obtained from a chiral effective field theory with pions, nucleons, and Δ. The agreement with the experimental data is satisfactory except for transitions in A = 8 nuclei. In this specific case, the theory significantly underpredicts the experimental data, which indicates the need of further improvements in the corresponding nuclear wave functions. In this study, emphasis is placed on the contributions of two-body axial currents that are carefully analyzed using two-body transition densities. This allow us to study the spatial distribution and short-range behavior of two-body dynamics. In particular, the transition densities when scaled to peak at 1.0 exhibit universal short-range behavior across the considered nuclei, while they differ in the long-range tails.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flow-dependent tagging of 214 Pb decays in the LZ dark matter detector

The LUX-ZEPLIN (LZ) experiment is searching for dark matter interactions in a liquid xenon time projection chamber (LXe-TPC). This article demonstrates how control of the flow state in the LXe-TPC enables the identification of pairs of sequential alpha-decays, which are used to map fluid flow and ion drift in the liquid target. The resulting transport model is used to tag 214 Pb~ beta-decays, a leading background to dark matter signals in LZ. Temporally evolving volume selections, at a cost of 9.0% of exposure, target the decay of each 214 Pb~ atom up to 81 minutes after production, resulting in (63±6 (s⁢t⁢a⁢t) ±7 (s⁢y⁢s) )% identification of 214 Pb~decays to ground state. We also demonstrate how flow-based tagging techniques enable a novel calibration side band that is concurrent with science data. Lastly we report updated estimates of radon-chain charge branching fractions in liquid xenon, finding branching to 218 Po + at 0.49±0.01, 214 Pb + at 0.48±0.12, and 214 Bi + at 0.74±0.05, with a mean charged ion lifetime in the LZ TPC of 49±4 min.

Lorenzon, Wolfgang [University of Michigan, Ann Ar↗