Search NASA⌕ Search

SEARCH · Search NASA

Results for “Base heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Report on High-Fidelity Dynamic Modeling of a Coal-Fired Steam Power Plant

As a result of the growth of renewables including solar and wind energy with fluctuating production, fossil fuel power plants are being required to cycle between high and low power production. This cycling is both at a greater frequency and over a wider range than in the past. In many cases, power plants are not designed for this type of cycling operation but can nonetheless endure these challenging operation requirements under the right conditions. In this project, optimal solution for enhanced flexible operations are being investigated using model based estimation and control techniques. To support the development of model-based estimator and model-based controls at GE Global Research, GE Steam Power configured a dynamic model using a reference steam plant design including the boiler, turbine, and water/steam conditioning systems as well as the controls needed for plant cycling with stability and reliability. The dynamic model was built using the APROS® software from VTT, and then calibrated to multiple load conditions from full load (100%TMCR) to partial loads (75%TMCR, 50%TMCR and 25%TMCR) based on internally developed steady state heat balance models at the unit level. These internal heat balance models are based on first principles and extensive engineering experiences from GE Steam Power as an OEM and a services provider. This topical report presents the structure of the unit level dynamic model, the tuning process, and representative simulation results from typical load cycling simulations using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aging of Limestones and Silane–Siloxane-Based Protective Hydrophobics: The Impact of Heating–Cooling and Freeze–Thaw Cycles

Stones are traditionally used in construction and architectural applications as building elements due to their aesthetic and technical/structural performance. Like other environmental factors (rain, humidity, moisture, salt presence, biological activity, etc.), heating–cooling and freeze–thaw cycles significantly threaten the longevity of stone materials. Hence, considering the socio-economic and cultural value of stones, preventive actions such as hydrophobic coatings are applied to prevent or mitigate damage. The scope of this study is the performance assessment of limestones with different characteristics and the efficiency of various commercial silane/siloxane-based hydrophobic coatings when exposed to thermal variation and freeze–thaw. For that purpose, the standards EN 14066:2013 (determination of resistance to aging by thermal shock) and EN 12371:2010 (determination of frost resistance) were followed. Open porosity and static contact angles were estimated to assess the stone durability and water protection capabilities of the hydrophobics. Additionally, sound speed propagation velocity, quality of building material index, elastic modulus and flexural strength were measured to evaluate the variation of mechanical properties. Static contact angle revealed that the coatings maintained an efficient level of hydrophobicity even after thermal-shock and freeze–thaw weathering tests. The study also revealed a critical interaction between freeze–thaw cycles, hydrophobic coatings and structural integrity of the stones, mostly on more porous ones. When they are subjected to harsh environmental conditions, untreated porous limestones keep structural cohesion, allowing for the natural absorption and release of water during freezing and thawing. On the contrary, when limestones are treated, the hydrophobic coatings can moderately obstruct the water release due to the partial saturation of the porous framework by the products. It also probably resulted from the different mechanical behavior between the inner matrix and layer of stone coated, resulting in a premature breakout and mechanical damage of the stone.

Lisci, Carla (ORCID:000000032179130X)↗

Simulation-Based Design and Optimization of Waste Heat Recovery Systems

This fact sheet features an R&D project that will develop a modeling platform that can quantify the value of a district energy system and its potential for waste heat recovery. The new software analysis platform will evaluate and optimize district energy systems to better utilize low-temperature waste heat from nearby commercial and industrial buildings. The platform will help project developers and engineers easily quantify the potential value and cost savings of community energy systems for both producers and consumers of waste heat.

Combined heat and power, CHP, District energy, Was↗

Tabulated Database of Closed-Loop Geothermal Systems Performance for Cloud-Based Technical and Economic Modeling of Heat Production and Electricity Generation: Preprint

To better understand the heat production, electricity generation performance and economic viability of closed loop geothermal systems in hot-dry-rock, the Closed Loop Geothermal Group, a consortium of several national labs and academic institutions has tabulated time-dependent numerical solutions and levelized cost results of two popular closed loop heat exchanger designs (u-tube and co-axial). The heat exchanger designs were evaluated for two working fluids (water and super-critical CO2) while varying seven continuous independent parameters of interest (i.e., mass flow rate, vertical depth, horizontal extent, borehole diameter, formation gradient, formation conductivity, and injection temperature). The corresponding numerical solutions (approximately 1.2 million per heat exchanger design) are stored as multi-dimensional HDF5 datasets and can be queried at off-grid points using multi-dimensional linear interpolation. A Python script was developed to query this database and estimate time-dependent electricity generation using an Organic Rankine cycle (for water) or direct turbine expansion cycle (for CO2) and perform a cost assessment. This document aims to give an overview of the HDF5 database file and highlights how to read, visualize, and query quantities of interest (e.g., levelized cost of electricity, levelized cost of heat) using the accompanying python scripts. Details regarding the capital, operation, and maintenance and levelized cost calculation using the TEA (techno-economic analysis) script are provided.

co-axial↗

Sockeye Theory Manual

Sockeye is an application that models heat pipe performance, based on the MOOSE framework. Its primary focus is on liquid-metal heat pipes with annular screen or porous wick structures, with the intended application being the simulation of heat pipes in microreactors. The purpose of this capability is to evaluate and understand heat pipe performance under different conditions. Furthermore, this heat pipe performance is intended to be coupled to multiphysics applications for modeling microreactors, so that the effects of heat pipe performance on the larger reactor system can be simulated.

42 ENGINEERING↗

Sustainable Energy Solutions for Thermal Load in Buildings—Role of Heat Pumps, Solar Thermal, and Hydrogen-Based Cogeneration Systems

Economic and population growth is leading to increased energy demand across all sectors—buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Potential technological solutions to address growing energy demand while simultaneously lowering the carbon footprint and enhancing the grid flexibility are presented in this study. Performance assessment of heat pumps, solar thermal collectors, nonfossil fuel-based cogeneration systems, and their hybrid configurations is reported in this study. The impact of design configuration, coefficient of performance (COP), electric grid’s primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail. In conclusion, heat pumps and hydrogen-fueled solid oxide fuel cells (SOFCs) are highly effective building energy resources compared to traditional approaches; however, the carbon intensity of electrical energy and hydrogen production are keys to the overall environmental benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver

High-temperature particle receivers are being pursued to enable next-generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 °C) to enable more efficient power cycles, lower overall system costs, and emerging CSP-based process-heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera- based imaging methods were developed and applied to both laboratory-scale and larger 1 MW t on-sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle-sampling methods using volumetric particle-air samplers were applied to the on-sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3-D printed tipping buckets and tethered balloons were also developed and applied to the on-sun particle-receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera-based imaging methods correlated well with measured values during the on-sun tests.

14 SOLAR ENERGY↗

Oscillating heat pipe integrated thermal management system for power electronics

Disclosed is a thermal management system for removing heat from a power electronic heat source, the system comprising: a base plate having a plurality of fluid passages there through and extending between and inlet side of the base plate and an outlet side of the base plate; and a plurality of heat transfer pipe segments respectively attached to one or more of the plurality of fluid passages at the inlet side of the base plate and the outlet side of the base plate, the plurality of heat transfer pipe segments arranged adjacent one another, the plurality of heat transfer pipe segments containing a two-phase working fluid, and the plurality of heat transfer pipe segments forming a continuous flow path through and back into the base plate for the two-phase working fluid.

Wang, Jim↗

A review of computing-based automated fault detection and diagnosis of heating, ventilation and air conditioning systems

We report faults in Heating, Ventilation, and Air Conditioning (HVAC) systems of buildings result in significant energy waste in building operation. With fast-growing sensing data availability and advancement in computing, computational modeling has demonstrated strong capability to detect and diagnose HVAC system faults, hence, ensuring efficient building operation. This paper comprehensively reviews the state-of-the-art computing-based fault detection and diagnosis (FDD) for HVAC systems. Overall, the reviewed computing-based FDD methods are classified as two major approaches: knowledge-based and data-driven approaches. We then identify multiple important topics, including data availability, training data size, data quality, approach generality, capability, interpretability, and required modeling efforts, along with corresponding metrics to summarize the most updated FDD development. Generally, the knowledge-based approaches are further divided as physics-based modeling, Diagnostic Bayesian Network, and performance indicator-based methods while data-driven approaches include supervised learning, unsupervised learning, and regression and statistics-based methods. State-of-the-art FDD development, remaining challenges, and future research directions are further discussed to push forward FDD in practice. Availability of fault data, capability of existing methods to deal with complex fault situations (such as simultaneous faults), modeling interpretability for data-driven methods, and required engineering efforts for physics-based methods are identified as remaining challenges in FDD development. Improving modeling fidelity and reducing modeling efforts are essential for applying physics-based methods in real buildings. Meanwhile, addressing fault data availability, increasing algorithm adaptability, and handling multiple faults are essential to further enhance the applicability of data-driven FDD approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Fourier Analysis-Based Evolutionary Multi-Objective Multiphysics Optimization of Liquid-Cooled Heat Sinks

Optimal heat dissipation in power modules can significantly increase their power density. Removing the generated heat is critical for capturing the benefits of advanced semiconductor materials and improving the reliability of the device operation. This article proposes a design optimization method for liquid-cooled heat sinks that use a Fourier analysis-based tool and an evolutionary optimization algorithm to optimize the heat sink geometry for specified objectives. The optimized heat sink geometry is then compared with state-of-the-art solutions in literature based on finite element analysis of different designs. The proposed methodology can develop complex geometries that outperform the conventional heat sink geometries.

Sahu, Raj↗

On the effect of elemental partitioning to secondary phases after solution and aging heat treatments in a Co-Ni-based superalloy

Here, this paper presents the phase stability and elemental partitioning in a Co-40Ni-10Al-7.5W-10Cr-3Nb-0.06B-0.6C (at.%) superalloy (referred to as 3Nb) after a two-step heat treatment. The resulting microstructure consisted of γ, γ', MC carbides and µ-Co 7 W 6 phase decorating the regions near and at the grain boundaries. Nb preferentially partitioned to the γ'-phase and other elements such as Ni, Cr and W were responsible for the μ-phase formation.

36 MATERIALS SCIENCE↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗