Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Low-noise spectrophone

Spectrophone, using continuous laser beam, operates at lower noise levels and thus detects trace amounts of gases with greater sensitivity.

Kavaya, M. J.↗

Interferometer Measures Broardband Surface Acoustic Waves

Dual differential interferometer uses two pairs of orthogonallypolarized optical beams to measure amplitude and orientation of broadband ultrasonic surface acoustic waves. Instrument modular, and sensitivity limited only by optical detector used.

Claus, R. O.↗

Rectangular Relief Diffraction Gratings for Coherent Lidar Beam Deflection

LIDAR systems require a light transmitting system for sending a laser light pulse into space and a receiving system for collecting the retro-scattered light, separating it from the outgoing beam and analyzing the received signal for calculating wind velocities. Currently, a shuttle manifested coherent LIDAR experiment called SPARCLE (SPAce Readiness Coherent Lidar Experiment) includes a silicon wedge (or prism) in its design in order to deflect the outgoing beam 30 degrees relative to the incident direction. The intent of this paper is to present two optical design approaches that may enable the replacement of the optical wedge component (in future, larger aperture, post-SPARCLE missions) with a surface relief transmission diffraction grating. Such a grating could be etched into a lightweight, flat, fused quartz substrate. The potential advantages of a diffractive beam deflector include reduced weight, reduced power requirements for the driving scanning motor, reduced optical sensitivity to thermal gradients, and increased dynamic stability.

Cole, H. J.↗

An Illumination Modeling System for Human Factors Analyses

Seeing is critical to human performance. Lighting is critical for seeing. Therefore, lighting is critical to human performance. This is common sense, and here on earth, it is easily taken for granted. However, on orbit, because the sun will rise or set every 45 minutes on average, humans working in space must cope with extremely dynamic lighting conditions. Contrast conditions of harsh shadowing and glare is also severe. The prediction of lighting conditions for critical operations is essential. Crew training can factor lighting into the lesson plans when necessary. Mission planners can determine whether low-light video cameras are required or whether additional luminaires need to be flown. The optimization of the quantity and quality of light is needed because of the effects on crew safety, on electrical power and on equipment maintainability. To address all of these issues, an illumination modeling system has been developed by the Graphics Research and Analyses Facility (GRAF) and Lighting Environment Test Facility (LETF) in the Space Human Factors Laboratory at NASA Johnson Space Center. The system uses physically based ray tracing software (Radiance) developed at Lawrence Berkeley Laboratories, a human factors oriented geometric modeling system (PLAID) and an extensive database of humans and environments. Material reflectivity properties of major surfaces and critical surfaces are measured using a gonio-reflectometer. Luminaires (lights) are measured for beam spread distribution, color and intensity. Video camera performances are measured for color and light sensitivity. 3D geometric models of humans and the environment are combined with the material and light models to form a system capable of predicting lighting conditions and visibility conditions in space.

Huynh, Thong↗

Microchannel spatial light modulator

The Microchannel Spatial Light Modulator (MSLM), a versatile, highly sensitive, and optically addressed device being developed for real time optical information processing is discussed. The MSLM operates by converting an input optical image into a charge distribution at the surface of an electro-optic crystal. The charge distribution generates an electric field which modulates the refractive index of the crystal and thereby the phase or intensity of an image readout beam. Prototype devices employing 250 micron thick crystals exhibited a spatial resolution of 5 cycles/mm at 50% contrast, an exposure sensitivity of 2.2 nJ/cu cm and framing rates of 40 Hz with full modulation depth. The image processing operations that have been achieved using the internal processing mode of the MSLM include contrast reversal, contrast enhancement, edge enhancement, image addition and subtraction, analog and digital intensity thresholding, and binary level logic operations such as AND, OR, EXCLUSIVE OR, and NOR.

Warde, C.↗

Ultrasonic signal enhancement by resonator techniques

Ultrasonic resonators increase experimental sensitivity to acoustic dispersion and changes in attenuation. Experimental sensitivity enhancement line shapes are presented which were obtained by modulating the acoustic properties of a CdS resonator with a light beam. Small changes in light level are made to produce almost pure absorptive or dispersive changes in the resonator signal. This effect is due to the coupling of the ultrasonic wave to the CdS conductivity which is proportional to incident light intensity. The resonator conductivity is adjusted in this manner to obtain both dispersive and absorptive sensitivity enhancement line shapes. The data presented verify previous thoretical calculations based on a propagating wave model.

Heyman, J. S.↗

A method for detecting structural deterioration in bridges

The problem of detecting deterioration in bridge structures is studied with the use of Randomdec analysis. Randomdec signatures, derived from the ambient bridge vibrations in the acoustic range, were obtained for a girder bridge over a period of a year to show the insensitivity of the signatures to environmental changes. A laboratory study was also conducted to show the sensitivity of signatures to fatigue cracks on the order of a centimeter in length in steel beams.

Cole, H. A., Jr.↗

Magnetic state selection in atomic frequency and time standards

Atomic standards such as those based upon cesium and hydrogen rely upon magnetic state selection to obtain population inversion in the hyperfine transition levels. Use of new design approaches and improved magnetic materials has made it possible to fabricate improved state selectors of small size, and thus the efficiency of utilization of beam flux is greatly improved and the size and weight of the standard is reduced. The sensitivity to magnetic perturbations is also decreased, so that the accuracy and stability of the standard is improved. Several new state selector designs are illustrated and the application to standards utilizing different atomic species is analyzed.

Peters, H. E.↗

Dynamic testing of a two-dimensional box truss beam

Testing to determine the effects of joint freeplay and pretensioning of diagonal members on the dynamic characteristics of a two-dimensional box truss beam was conducted. The test article was ten bays of planar truss suspended by long wires at each joint. Each bay measured 2 meters per side. Pins of varying size were used to simulate various joint freeplay conditions. Single-point random excitation was the primary method of test. The rational fraction polynomial method was used to extract modal characteristics from test data. A finite element model of the test article was generated from which modal characteristics were predicted. These were compared with those obtained from tests. With the exception of the fundamental mode, correlation of theoretical and experimental results was poor, caused by the resonant coupling of local truss member bending modes with global truss beam modes. This coupling introduced many modes in the frequency range of interest whose frequencies were sensitive to joint boundary conditions. It was concluded that local/global coupling must be avoided in the frequency range where accurate modal characteristics are required.

White, Charles W.↗

Spacecraft charging in the auroral plasma: Progress toward understanding the physical effects involved

The work is presented in four parts. First, main differences between the plasma environments in geostationary orbit and low polar orbit with regard to high-voltage charging situations are reviewed. Next, results are presented from a calculation of secondary-electron escape currents from negatively-charged spacecraft surfaces having various orientations relative to the local magnetic-field direction. It is shown that for finite ranges of combinations of electric and magnetic field directions, secondary-electron escape is completely suppressed and therefore cannot help to discharge the spacecraft. In such circumstances, secondary electrons may travel distances many times their gyroradii before reimpacting, and this may produce greatly increased secondary-electron surface currents. Thirdly, a simple rough estimate of the required conditions for high-voltage auroral-zone charging is developed. The results suggest that for any given spacecraft, surface potentials are likely to depend more strongly on the ratio of ambient flux of high-energy electrons to that of all ions, than on any other environmental parameter. Finally, preliminary results are presented of numerical simulation work directed toward testing this hypothesis. Numerical instabilities encountered in doing this simulation work probably are closely related to physical sensitivities inherent in the physics of the ion wake behind the spacecraft, and especially to beam-like constituents of the ion population in the wake.

Laframboise, J. G.↗

Electric fields in the solar atmosphere - A review

A review is presented of remote sensing techniques which measure the electric field component transverse to the line of sight and achieve a sensitivity range of 5-10 V/cm. Three models are shown to predict quasistatic, macroscopic values of E(parallel), the electric field component parallel to the magnetic vector, beyond the sensitivity range considered. These processes are: the discharge model of flares; the models of return currents related to flare particle beams; and the models of neutral sheets related to two-ribbon flares and postflare loops. Time dependent electric fields related to MHD and plasma waves, and to plasma disturbance, may allow the detection of both E components (parallel and perpendicular). The uncertainty relating to the emission measures, time scales, volumes, and plasma conditions of these flares and electrified plasma volumes is emphasized. It is pointed out, however, that important information can be obtained by observing electric fields at existing sensitivity levels. By measuring these E-fields, the understanding of flares and related dynamic events can be improved.

Foukal, P.↗

Measuring Hydrogen Plumes With Raman Lidar

Prototype Raman lidar system measures concentration of hydrogen gas in atmosphere as function of position, with range resolution of 3 ft over 3,000 ft. Sensitive to concentrations smaller than 0.5 percent, 10 times below minimum flammable concentration. Pulsed ultraviolet laser beam excites Raman emissions from molecules to be detected. Backscattered light collected by telescope, filtered at appropriate wavelengths, and sent to photodetectors. Developed for use as safety monitor, and to study dispersion of hydrogen gas leaking into atmosphere.

Caputo, Bernard↗

Scientific applications of frequency-stabilized laser technology in space

A synoptic investigation of the uses of frequency-stabilized lasers for scientific applications in space is presented. It begins by summarizing properties of lasers, characterizing their frequency stability, and describing limitations and techniques to achieve certain levels of frequency stability. Limits to precision set by laser frequency stability for various kinds of measurements are investigated and compared with other sources of error. These other sources include photon-counting statistics, scattered laser light, fluctuations in laser power, and intensity distribution across the beam, propagation effects, mechanical and thermal noise, and radiation pressure. Methods are explored to improve the sensitivity of laser-based interferometric and range-rate measurements. Several specific types of science experiments that rely on highly precise measurements made with lasers are analyzed, and anticipated errors and overall performance are discussed. Qualitative descriptions are given of a number of other possible science applications involving frequency-stabilized lasers and related laser technology in space. These applications will warrant more careful analysis as technology develops.

Schumaker, Bonny L.↗

In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.

Sarrazin, P.↗

Effect of Alignment on Transport Properties of Carbon Nanotube/Metallic Junctions

Ballistic and spin coherent transport in single walled carbon nanotubes (SWCNT) are predicted to enable high sensitivity single-nanotube devices for strain and magnetic field sensing. Based upon these phenomena, electron beam lithography procedures have been developed to study the transport properties of purified HiPCO single walled carbon nanotubes for development into sensory materials for nondestructive evaluation. Purified nanotubes are dispersed in solvent suspension and then deposited on the device substrate before metallic contacts are defined and deposited through electron beam lithography. This procedure produces randomly dispersed ropes, typically 2 - 20 nm in diameter, of single walled carbon nanotubes. Transport and scanning probe microscopy studies have shown a good correlation between the junction resistance and tube density, alignment, and contact quality. In order to improve transport properties of the junctions a technique has been developed to align and concentrate nanotubes at specific locations on the substrate surface. Lithographic techniques are used to define local areas where high frequency electric fields are to be concentrated. Application of the fields while the substrate is exposed to nanotube-containing solution results in nanotube arrays aligned with the electric field lines. A second electron beam lithography layer is then used to deposit metallic contacts across the aligned tubes. Experimental measurements are presented showing the increased tube alignment and improvement in the transport properties of the junctions.

Wincheski, Buzz↗

The Ice, Cloud, and Land Elevation Satellite-2 Mission: A Global Geolocated Photon Product Derived from the Advanced Topographic Laser Altimeter System

The Ice, Cloud, and land Elevation Satellite – 2 (ICESat-2) observatory was launched on 15 September 2018 to measure ice sheet and glacier elevation change, sea ice freeboard, and enable the determination of the heights of Earth’s forests. ICESat-2’s laser altimeter, the Advanced Topographic Laser Altimeter System (ATLAS) uses green (532 nm) laser light and single-photon sensitive detection to measure time of flight and subsequently surface height along each of its six beams. In this paper, we describe the major components of ATLAS, including the transmitter, the receiver and the components of the timing system. We present the major components of the ICESat-2 observatory, including the Global Positioning System, star trackers and inertial measurement unit. The ICESat-2 Level 1B data product (ATL02) provides the precise photon round-trip time of flight, among other data. The ICESat-2 Level 2A data product (ATL03) combines the photon times of flight with the observatory position and attitude to determine the geodetic location (i.e. the latitude, longitude and height) of the ground bounce point of photons detected by ATLAS. The ATL03 data product is used by higher-level (Level 3A) surface-specific data products to determine glacier and ice sheet height, sea ice freeboard, vegetation canopy height, ocean surface topography, and inland water body height.

ICESat-2↗

CODEX Optical Design and Alignment

The COronal Diagnostic EXperiment (CODEX) is a Heliophysics mission to measure the density, temperature, and velocity of the electrons in the solar corona with the primary goal of improving our understanding of the physical conditions of the solar wind in the acceleration region. The temperature and velocity measurement requires much higher signal-to-noise ratio than the density measurements. In solar coronagraphs, the diffraction of the solar disk light due to the occulting element is the dominant source of noise. Therefore, to further suppress the diffracted sun light with respect to the existing coronagraphs is a critical element of the CODEX design. To minimize the stray light due to diffraction, the selected optical design is a two-stage standard coronagraph with an external occulter, an internal occulter, and a Lyot stop. What is unique for this design is that a focal mask was inserted at the telescope focal plane. It works together with the field lens suppressing the stray light down by ~ another order of magnitude as compared to a traditional three-stage approach. During the optical design, a Fourier Transform based beam propagation software, i.e., GLAD, was used to model the beam path through the full coronagraph, from the external occulter to the detector array. All diffraction sensitive elements: external occulter, internal occulter, focal mask, and Lyot stop were carefully modeled and optimized. As a result, the requirement of achieving a stray light level which is one order of magnitude lower than F-corona was satisfied. On the other hand, to achieve the final suppression, a precision optical alignment is another must. This paper also presents our creative alignment procedure: using the combination of metrology, precision alignment equipment, and real time diffraction ring monitoring to minimize the diffraction. The final test results show that the suppression ratio (B/B 0 ) reaches 10 -11 level, which is equivalent to one order of magnitude lower than F-corona.

CODEX optical design and alignment↗