Search NASA⌕ Search

SEARCH · Search NASA

Results for “CFD modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Calculation of Friction Factors in Heat Pipes Using CFD in Support of the Sockeye Code

A heat pipe is two-phase heat transfer device which relies on surface tension and capillary pressure to provide a very efficient heat transfer mechanism. Currently, there is interest in designing micro nuclear power reactors using high temperature heat pipes to provide totally passive cooling. To support this, Sockeye is being developed as a heat pipe simulation capability. To support the development of Sockeye, individual phenomena must be tested. This work focuses on applying a CFD model to evaluate friction factors for use in Sockeye. A CFD model has been developed in Nek5000 which simulates each component fluid, i.e. sodium liquid and vapor, independently and captures the effects of the wick on friction factor. The model tests the effect of the wick permeability and the thickness of the wick occupied by each fluid component. The thickness of the wick occupied by each component can be directly related to the local vapor volume fraction from the Sockeye heat pipe model. Results from the CFD model indicate that friction factor in the liquid flow decreases with increasing wick permeability, while the friction factor in the vapor flow increases with increasing wick permeability. In the liquid, this is likely a direct result of the increased cross sectional area available for the flow. For the vapor, this is explained as the wick acting like a rough wall, while the increased area has only a negligible impact. Results for the tests of the thickness of the wick occupied by each fluid showed a thresholding behavior for both liquid and vapor. When the thickness of the wick occupied by each fluid was increased, it increased the effect of the wick, but only up to a certain point. Once a certain thickness was reached, the friction factors remained constant. When the fluid occupied only a very small fraction of the wick, friction factors returned to nominal values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Model Reduction for Steady Hypersonic Aerodynamics via Conservative Manifold Least-Squares Petrov–Galerkin Projection

High-speed aerospace engineering applications rely heavily on computational fluid dynamics (CFD) models for design and analysis. This reliance on CFD models necessitates performing accurate and reliable uncertainty quantification (UQ) of the CFD models, which can be very expensive for hypersonic flows. Additionally, UQ approaches are many-query problems requiring many runs with a wide range of input parameters. One way to enable computationally expensive models to be used in such many-query problems is to employ projection-based reduced-order models (ROMs) in lieu of the (high-fidelity) full-order model (FOM). In particular, the least-squares Petrov–Galerkin (LSPG) ROM (equipped with hyper-reduction) has demonstrated the ability to significantly reduce simulation costs while retaining high levels of accuracy on a range of problems, including subsonic CFD applications. This allows LSPG ROM simulations to replace the FOM simulations in UQ studies, making UQ tractable even for large-scale CFD models. This work presents the first application of LSPG to a hypersonic CFD application, the Hypersonic International Flight Research Experimentation 1 (HIFiRE-1) in a three-dimensional, turbulent Mach 7.1 flow. This paper shows the ability of the ROM to significantly reduce computational costs while maintaining high levels of accuracy in computed quantities of interest.

42 ENGINEERING↗

Investigation of Iso-octane Ignition and Validation of a Multizone Modeling Method in an Ignition Quality Tester

An ignition quality tester was used to characterize the autoignition delay times of iso-octane. The experimental data were characterized between temperatures of 653 and 996 K, pressures of 1.0 and 1.5 MPa, and global equivalence ratios of 0.7 and 1.05. A clear negative temperature coefficient behavior was seen at both pressures in the experimental data. These data were used to characterize the effectiveness of three modeling methods: a single-zone homogeneous batch reactor, a multizone engine model, and a three-dimensional computational fluid dynamics (CFD) model. A detailed 874 species iso-octane ignition mechanism (Mehl, M.; Curran, H. J.; Pitz, W. J.; Westbrook, C. K.Chemical kinetic modeling of component mixtures relevant to gasoline. Proceedings of the European Combustion Meeting; Vienna, Austria, April 14-17, 2009) was reduced to 89 species for use in these models, and the predictions of the reduced mechanism were consistent with ignition delay times predicted by the detailed chemical mechanism across a broad range of temperatures, pressures, and equivalence ratios. The CFD model was also run without chemistry to characterize the extent of mixing of fuel and air in the chamber. The calculations predicted that the main part of the combustion chamber was fairly well-mixed at longer times (> ~30 ms), suggesting that the simpler models might be applicable in this quasi-homogeneous region. The multizone predictions, where the combustion chamber was divided into 20 zones of temperature and equivalence ratio, were quite close to the coupled CFD-kinetics results, but the calculation time was ~11 times faster than the coupled CFD-kinetics model. Although the coupled CFD-kinetics model captured the observed negative temperature coefficient behavior and pressure dependence, discrepancies remain between the predictions and the observed ignition time delays, suggesting improvements are still needed in the kinetic mechanism and/or the CFD model. This approach suggests a combined modeling approach, wherein the CFD calculations (without chemistry) can be used to examine the sensitivity of various model inputs to in-cylinder temperature and equivalence ratios. In conclusion, these values can be used as inputs to the multizone model to examine the impact on ignition delay. Additionally, the speed of the multizone model also makes it feasible to quickly test more detailed kinetic mechanisms for comparison to experimental data and sensitivity analysis.

33 ADVANCED PROPULSION SYSTEMS↗

Computational fluid dynamic modeling of fluidized-bed polymerization reactors

Polyethylene is one of the most widely used plastics, and over 60 million tons are produced worldwide every year. Polyethylene is obtained by the catalytic polymerization of ethylene in gas and liquid phase reactors. The gas phase processes are more advantageous, and use fluidized-bed reactors for production of polyethylene. Since they operate so close to the melting point of the polymer, agglomeration is an operational concern in all slurry and gas polymerization processes. Electrostatics and hot spot formation are the main factors that contribute to agglomeration in gas-phase processes. Electrostatic charges in gas phase polymerization fluidized bed reactors are known to influence the bed hydrodynamics, particle elutriation, bubble size, bubble shape etc. Accumulation of electrostatic charges in the fluidized-bed can lead to operational issues. In this work a first-principles electrostatic model is developed and coupled with a multi-fluid computational fluid dynamic (CFD) model to understand the effect of electrostatics on the dynamics of a fluidized-bed. The multi-fluid CFD model for gas-particle flow is based on the kinetic theory of granular flows closures. The electrostatic model is developed based on a fixed, size-dependent charge for each type of particle (catalyst, polymer, polymer fines) phase. The combined CFD model is first verified using simple test cases, validated with experiments and applied to a pilot-scale polymerization fluidized-bed reactor. The CFD model reproduced qualitative trends in particle segregation and entrainment due to electrostatic charges observed in experiments. For the scale up of fluidized bed reactor, filtered models are developed and implemented on pilot scale reactor.

42 ENGINEERING↗

Reduced order model based on principal component analysis for process simulation and optimization

It is well-known that distributed parameter computational fluid dynamics (CFD) models provide more accurate results than conventional, lumped-parameter unit operation models used in process simulation. Consequently, the use of CFD models in process/equipment co-simulation offers the potential to optimize overall plant performance with respect to complex thermal and fluid flow phenomena. Because solving CFD models is time-consuming compared to the overall process simulation, we consider the development of fast reduced order models (ROMs) based on CFD results to closely approximate the high-fidelity equipment models in the co-simulation. By considering process equipment items with complicated geometries and detailed thermodynamic property models, this study proposes a strategy to develop ROMs based on principal component analysis (PCA). Taking advantage of commercial process simulation and CFD software (for example, Aspen Plus and FLUENT), we are able to develop systematic CFD-based ROMs for equipment models in an efficient manner. In particular, we show that the validity of the ROM is more robust within well-sampled input domain and the CPU time is significantly reduced. Typically, it takes at most several CPU seconds to evaluate the ROM compared to several CPU hours or more to solve the CFD model. Two case studies, involving two power plant equipment examples, are described and demonstrate the benefits of using our proposed ROM methodology for process simulation and optimization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CFD-Chemical Model of One-Third Scale Demonstration of DOE Sealed Canister with ATR Fuel

Road-ready and final disposition packaging configurations for the advanced test reactor (ATR) fuel currently specifies storage within helium backfilled DOE sealed standard canisters. The aluminum cladding of the ATR fuel contains an oxyhydroxide layer of boehmite/bayerite that generates hydrogen when subjected to irradiation. Understanding the effect of this hydrogen buildup over time to important for long term storage considerations. Previous modeling efforts have built a coupled CFD-chemical model to simulate the temperature gas phase concentrations within the DOE sealed standard canisters. A demonstration case for these DOE sealed canisters will be eventually performed with a one-third scale mockup that has been instrumented with thermocouples and gas concentration probes. This study seeks to model the planned canister for validation of the previously developed model, such that confidence in its long-term prediction can be increased. The deployment of the instrumented lid for online monitoring in intended for a period of 10+ years based on previous monitoring of commercial fuel storage; however, the model is still run for the previously used 50-year storage periods. This case is modeled with a G-value using a bi-linear function such that it decreases at higher dose rates to be consistent with experiments. Validation efforts of the model would likely revolve around the results for the 1st year, so the results of this timeframe are also highlighted. For dried fuel of the nominal decay heat (18W), the predicted hydrogen concentration is 0.19% after 1 year, 0.91% after 10 years, and 2.8% after 50 years, with a maximum pressure of 1.26 atm. Consistent with previous modeling, the decay heat of the fuel is the main factor that influences the results. For undried fuel in pure helium, the hydrogen concentration ranges from 0.23 to 1.2% after 1 year, 1.25-6.2% after 10 years and 8.8 to 18.84% after 50 years. For dried fuel in pure helium the hydrogen concentration ranges from 0.06% to 0.34% after 1 year, 0.35-2.11% after 10 years and 0.95 to 6.6% after 50 years. While long-term results in the presence of residual air are mostly the same, early reactions with O 2 can delay significant production of H 2 until it is consumed to form more water vapor, lowering the range to 0.14 to 1.0% after 1 year. The maximum absolute pressure that is reached across any scenario is 2.06 atm. In the event of residual air, the presence of nitric acid is possible in the range of 18-131 ppm after 1 year, 174-1180 ppm after 10 years, and 586-3500 ppm after 50 years. As long as the fuel is sufficiently dried, or of nominal decay heat, a 4% lower flammability limit of hydrogen will not be reached within a 10-year monitoring period.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical Analysis of Water Harvesting from Saturated Vapor with the Electrospray Water Droplet Injection in The Solar-Driven Desalination Applications

Solar-driven seawater desalination systems provide freshwater through environmentally friendly and carbon-neutral processes. Air humidification and dehumidification desalination (HDD) systems extract water directly from moist air. This paper focuses on a new solar-driven seawater desalination system that shares some common traits with HDD systems but in which the air is eliminated from the process. Seawater is vaporized by solar thermal radiation in high-performance solar panels. Water vapor flows to a new electro-condensation chamber and passes through a series of electrosprays, which inject small nuclei of freshwater droplets into the vapor clouds. Here, due to dielectrophoresis and electrohydrodynamic flows, the vapor molecules are captured by the charged droplets, and vapor is condensed at the droplet surface. The water vapor condensation was modeled by using the multiphase flow numerical model. The CFD model, which was also experimentally validated, used SprayFoam solver modules available in the Open FOAM® CFD open-source software. In preliminary results, 802 grams/(hr-m2) (grams per hour per unit area) of water was harvested directly from moist air at 24C and 90% relative humidity. The simulation results indicated that freshwater productivity could increase up to 4,000 grams/(hr-m2) for fully saturated air conditions. This represents about 5 times the water productivity rate of current conventional HDD systems today. In addition, energy consumption could be reduced by 80 percent compared to conventional HDD systems.

Electrospray, electro-condensation, solar, droplet↗

Numerical Investigation of Enhanced Dehumidification Processes By Using Dielectrophoresis Principles in Moist Airflows

Dispersed particle-laden flows are encountered in many building and industrial applications, such as flow in a fluidized bed, hydrocarbon transportation in pipelines, and the fouling of air-cooled heat exchangers (Kuruneru et al., 2016; Ray et al., 2019; Wang et al., 2019). Computational fluid dynamic (CFD) models have been developed in recent years to depict particle-fluid and particle-particle interactions in laminar or turbulent flows with increasing accuracy and stability. One particular particle-laden system of interest for moisture control is electrically-enhanced condensation in air and water droplet flows. Electrically-enhanced condensation consists of the use of highly charged water droplets injected in the moist air. The droplets become electric seeds that attract polar water vapor molecules to their surfaces and promote condensation. The nucleation and growth of the charged droplets deplete the vapor phase near a droplet, which is compensated for by the dielectrophoresis flow and diffusion. Dielectrophoresis flow involves surrounding vapor at a distance of about 10 to 100 nm for droplets charged by an electrospray compared to ~2 nm for a single electron charge in a droplet. As the vapor molecules collapse on the surface of the droplets, their initial electrical charge decreases with time due to the neutralization of the ions. While the physics of this phenomena is well known, engineering models for predicting the condensation rates are not available. This work computationally investigates dehumidification of moist airflow in a converging rectangular duct. The objective is to develop an engineering model that predicts water vapor condensation by employing dielectrophoresis principles. We construct a Computational Fluid Dynamics (CFD) model of the duct with electrically-enhanced condensation. The model is implemented in the open-source software OpenFOAM. We utilize the Multi-Phase Particle-In-Cell (MP-PIC) method coupled with a Population Balance Equation (PBE) approach to simulate the particle-laden system. This methodology is an Eulerian-Lagrangian approach used to simulate the droplets' behavior in the humid air. The MP-PIC approach (Andrews and O'Rourke, 1996) mitigates the computational cost by parceling several fundamental particles with similar properties (such as types, sizes, and temperature) into one computational particle. Thus, the billions of particles can be substituted by millions of computational particles without significant loss of information. The PBE was considered with the Lagrangian frame to combine the particle distribution function used in MP-PIC (Kim et al., 2020). This approach preserves mass and energy conservation between the phases in the Eulerian and Lagrangian structures. The PBE in this procedure was directly linked to the discrete parcels, making the simulation of the particle distribution computationally efficient and robust. The MP-PIC-PBE approach used in the present work was applied to the dehumidification of air. Water droplets were injected in the air stream and forced to grow according to experimentally derived correlation. The experiments were conducted on a converging duct with the same geometry and boundary conditions used to build the CFD model. This approach enabled us to approximate the effect of dielectrophoresis phenomena on the droplet and air interface. This presentation will discuss the details of the new CFD model built for the duct, the implementation of the model in OpenFOAM CFD programming language, and the experimental validation of the newly developed model. The results revealed a moderate yet measurable increase in droplet diameter due to water vapor condensation at the vapor-liquid interface of the electrically charged droplets' surface. The seed water droplet particles grew in size by capturing the water vapor in the surrounding air. The OpenFOAM model predicted reductions of humidity in the air from 5 to 10 percent.

Yel Mahi, Maliha↗

Modeling Heat Pipes with Non-Condensable Gases

The report showcases advancements in modeling heat pipes, considering both scenarios with and without non-condensable gases. To achieve this, two distinct modeling approaches are juxtaposed. Firstly, the effective conduction model, implemented in the MOOSE-based code Sockeye, is employed. Secondly, a first-of-a-kind two-phase Euler-Euler Computational Fluid Dynamics (CFD) model is developed using the STAR-CCM+ code. Both models undergo validation against experimental data, acknowledging the inherent uncertainties associated with each modeling assumption. Interestingly, the non-tuned CFD model surpasses the performance of the calibrated conduction model for heat pipes operating under both conditions: with and without non-condensable gases. It's worth noting, however, that the CFD models entail significantly longer runtimes compared to the conduction models. Nevertheless, the insights garnered from the CFD model shed invaluable light on the intricate operational dynamics of heat pipes. Future work involves broadening the validation scope of these models and continuing their development to enhance their utility as robust tools for heat pipe design and operational support.

42 ENGINEERING↗

Design and Experimental Demonastration of a High Pressure Oxy-Methane Combustor

Motivated by the advantages of pressured oxy-combustion, the primary purpose of this experimental study is to design and test a methane-oxygen burner and combustor. The combustor is designed to operate at a firing input of 500 kW and 20 bar chamber pressure. Multiple components of the system are first modeled in CFD to predict performance and design for safety. These components include the methane-oxygen burner, ignition system, and combustor pressurization systems. The simulation is conducted using a 2D domain. Using the expected performance parameters, the experimental system was built and tested. In this particular paper, the test data are presented for 160 kW power inputs and 7 bar chamber pressure. Afterwards, a qualitative and quantitative comparison is performed. For example, in order to pressurize the combustor, the exit area was restricted. The CFD model shows that to achieve a pressure of 7 bar in the chamber an exit diameter of 6.4mm is needed. However, during actual testing a 3.175mm exit diameter orifice is used. This discrepancy between the test results and CFD results is due to the leaking of gases in the combustor. Future testing includes the effect of convective CO2 cooling at the combustor wall and water based cooling at the combustor end cap

03 NATURAL GAS↗

Modeling Self-Pressurization and Spray Bar Pressure Control of A Cryogenic Storage Tank in Normal Gravity

This paper presents computational fluid dynamics (CFD) models for simulating self-pressurization and spray-bar pressure control processes in a large-scale liquid hydrogen storage tank under normal gravity conditions. For self-pressurization, the model employs the kinetics-based Schrage equation alongside the volume-of-fluid (VOF) method to account for interfacial mass transfer. The CFD predictions of pressure and temperature are compared with experimental data from the Multipurpose Hydrogen Test Bed (MHTB) experiment, and the predicted interfacial mass transfer rates are also presented. A CFD model simulating pressure control using a spray bar has also been developed. An Eulerian-Lagrangian approach models the interactions between discrete droplets and the continuous ullage (vapor) phase. The spray model is coupled with the VOF method by tracking droplets in the ullage and removing them when they reach the liquid interface. The T-sat model calculates droplet-ullage heat and mass transfer, where droplets warm up to the saturation temperature corresponding to the ullage vapor pressure before evaporating while remaining at the saturation temperature. The evolution of tank pressure, vapor temperature, and liquid temperature predicted by the CFD model is validated against data from the MHTB spray-bar mixing experiment. Overall, the CFD models agree with experimental data, demonstrating their capability to simulate self-pressurization and pressure control processes in large-scale cryogenic storage tanks. These models can be valuable tools for designing and optimizing cryogenic fluid management systems in future applications.

Computational Fluid Dynamics↗

Modeling Self-Pressurization and Spray Bar Pressure Control of A Cryogenic Storage Tank in Normal Gravity

This paper presents computational fluid dynamics (CFD) models for simulating self-pressurization and spray-bar pressure control processes in a large-scale liquid hydrogen storage tank under normal gravity conditions. For self-pressurization, the model employs the kinetics-based Schrage equation alongside the volume-of-fluid (VOF) method to account for interfacial mass transfer. The CFD predictions of pressure and temperature are compared with experimental data from the Multipurpose Hydrogen Test Bed (MHTB) experiment, and the predicted interfacial mass transfer rates are also presented. A CFD model simulating pressure control using a spray bar has also been developed. An Eulerian-Lagrangian approach models the interactions between discrete droplets and the continuous ullage (vapor) phase. The spray model is coupled with the VOF method by tracking droplets in the ullage and removing them when they reach the liquid interface. The T-sat model calculates droplet-ullage heat and mass transfer, wherein droplets warm up to the saturation temperature corresponding to the ullage vapor pressure before evaporating while remaining at the saturation temperature. The evolution of tank pressure, vapor temperature, and liquid temperature predicted by the CFD model is validated against data from the MHTB spray-bar mixing experiment. Overall, the CFD models agree with experimental data, demonstrating their capability to simulate self-pressurization and pressure control processes in large-scale cryogenic storage tanks. These models can be valuable tools for designing and optimizing cryogenic fluid management systems in future applications.

Self-Pressurization↗

Comparison of High Pressure Transient PVT Measurements and Model Predictions – Part I

A series of experiments consisting of vessel-to-vessel transfers of pressurized gas using Transient PVT methodology have been conducted to provide a data set for optimizing heat transfer correlations in high pressure flow systems. In rapid expansions such as these, the heat transfer conditions are neither adiabatic nor isothermal. Compressible flow tools exist, such as NETFLOW that can accurately calculate the pressure and other dynamical mechanical properties of such a system as a function of time. However to properly evaluate the mass that has transferred as a function of time these computational tools rely on heat transfer correlations that must be confirmed experimentally. In this work new data sets using helium gas are used to evaluate the accuracy of these correlations for receiver vessel sizes ranging from 0.090 L to 13 L and initial supply pressures ranging from 2 MPa to 40 MPa. The comparisons show that the correlations developed in the 1980s from sparse data sets perform well for the supply vessels but are not accurate for the receivers, particularly at early time during the transfers. This report focuses on the experiments used to obtain high quality data sets that can be used to validate computational models. Part II of this report discusses how these data were used to gain insight into the physics of gas transfer and to improve vessel heat transfer correlations. Network flow modeling and CFD modeling is also discussed.

99 GENERAL AND MISCELLANEOUS↗

The Zero Boil-Off Tank Experiment Contributions to the Development of Cryogenic Fluid Management

The Zero Boil-Off Technology (ZBOT) Experiment involves performing a small scale ISS experiment to study tank pressurization and pressure control in microgravity. The ZBOT experiment consists of a vacuum jacketed test tank filled with an inert fluorocarbon simulant liquid. Heaters and thermo-electric coolers are used in conjunction with an axial jet mixer flow loop to study a range of thermal conditions within the tank. The objective is to provide a high quality database of low gravity fluid motions and thermal transients which will be used to validate Computational Fluid Dynamic (CFD) modeling. This CFD can then be used in turn to predict behavior in larger systems with cryogens. This paper will discuss the current status of the ZBOT experiment as it approaches its flight to installation on the International Space Station, how its findings can be scaled to larger and more ambitious cryogenic fluid management experiments, as well as ideas for follow-on investigations using ZBOT like hardware to study other aspects of cryogenic fluid management.

Fluid management↗

The Zero Boil-Off Tank Experiment Ground Testing and Verification of Fluid and Thermal Performance

The Zero Boil-Off Technology (ZBOT) Experiment involves performing a small scale International Space Station (ISS) experiment to study tank pressurization and pressure control in microgravity. The ZBOT experiment consists of a vacuum jacketed test tank filled with an inert fluorocarbon simulant liquid. Heaters and thermo-electric coolers are used in conjunction with an axial jet mixer flow loop to study a range of thermal conditions within the tank. The objective is to provide a high quality database of low gravity fluid motions and thermal transients which will be used to validate Computational Fluid Dynamic (CFD) modeling. This CFD can then be used in turn to predict behavior in larger systems with cryogens. This paper will discuss the work that has been done to demonstrate that the ZBOT experiment is capable of performing the functions required to produce a meaningful and accurate results, prior to its launch to the International Space Station. Main systems discussed are expected to include the thermal control system, the optical imaging system, and the tank filling system.This work is sponsored by NASAs Human Exploration Mission Directorates Physical Sciences Research program.

Fluid management↗

Flow Boiling and Condensation Experiment (FBCE): Summary of Findings for Flow Boiling based on Completed ISS Experiments

Since 2011, researchers from Purdue University and NASA Glenn Research Center (GRC) have been collaborating to investigate the effects of gravity on several aspects of flow boiling and flow condensation. This massive research endeavor, termed the Flow Boiling and Condensation Experiment (FBCE), has culminated in development of NASA’s largest and most complex facility for investigation of two-phase fluid physics onboard the ISS. FBCE consists of two separate studies: flow boiling, using the Flow Boiling Module (FBM), and flow condensation, using the Condensation Module for Heat Transfer Measurements (CM-HT); this presentation concerns the FBM portion of FBCE. Fitted with FBM, FBCE was launched to the ISS in August 2021 and experiments were successfully performed starting in February 2022 to amass a large microgravity-flow-boiling database supported by extensive visualization of interfacial behavior using high-speed video. Based on FBCE experiments performed previously in Earth gravity and parabolic flight, along with the new ISS data, several empirical correlations, theoretical models, and CFD models have been developed, enabling the prediction of crucial flow boiling parameters, including heat transfer coefficient and critical heat flux (CHF). These predictive tools, which will be summarized in this presentation, are expected to serve as foundation for design of future space systems involving flow boiling.

Two-phase flow and phase transition↗

CFD Validation and Scaling of a Condenser Used in an ISRU Propellant Production System

This work develops a Computational Fluid Dynamics (CFD) model of a Commercial-Off-The-Shelf (COTS) condenser used for ground-based testing of an In-Situ Resource Utilization (ISRU) propellant production system. STAR-CCM+ was used to simulate water condensing through the condenser downstream of a methanation reactor. The computational data of the digital model is validated with test cases using nitrogen and water in ambient conditions. After validation with the test data, the digital model can be used to predict scale at higher production targets. The StarCCM+ simulation of the digital model shows good agreement with the test data provided. From the simulation, the condensation rate calculated was 18.3 g/hr and the process gas mass flow rate was 709.2 g/hr. The test data measured an average 16.9 g/hr condensation rate and 693.6 g/hr process gas mass flow rate. The simulation shows a 7.3% error in the water condensation and 2.2% error in the process gas at the outlet.

Condenser↗

THERMAL MODELING OF HANFORD CESIUM AND STRONTIUM CANISTERS DURING SIMULATED LOADING

A computational fluid dynamics (CFD) model was built to simulate planned testing of heater assemblies within a canister and overpack for the Hanford Lead Canister (HLC) project. The HLC is a canister storage system that will contain heaters to simulate the decay heat of nuclear material and provide the canister storage system with environmental conditions equivalent to the operating conditions on a dry storage pad. The HLC will be equipped with long-term data collection and monitoring systems to provide an early warning of corrosion, pitting, cracking, or other signs of canister degradation that might threaten the integrity of the containment boundary over the potentially long term of dry storage. An important part of the HLC development is to make pretest numerical predictions for the behavior of the heated canister during the simulated radiolytic decay heat testing, which simulates the dry storage system during loading operations. The simulated radiolytic decay heat test is planned for mid-2024 in a configuration that includes the heater assembly, overpack, and canister, but with the lids removed to allow loading cesium and strontium capsules into the canister. One of the goals of the test is to evaluate the thermal behavior of the canister and overpack assembly in the ambient air of the test facility, which will provide data critical to validating the thermal models and understanding how the HLC will perform as a system once deployed. To best approximate real-world conditions, the CFD model includes the full air volume of the mock-up truck bay the heated canister test will be performed in, enabling detailed investigation of how the heated canister affects airflow around it. Rigorous pre-deployment testing of the complete HLC cask and canister system is intended to be completed before the HLC is deployed in the 2028 timeframe. This study presents the pre-test temperature predictions of the simulated radiolytic decay heat test. A description of the heater assembly, canister, and overpack system is presented. The model was developed with the commercial CFD software STAR-CCM+. An uncertainty analysis was run with the CFD model to determine the uncertainty in the temperature predictions and provide a range over which the predicted temperatures are expected to vary. The uncertainty analysis was preformed by coupling STAR-CCM+ with the software Dakota, which provides advanced parametric analyses, including quantification of margins and uncertainty with computational models. This work is expected to provide insight into SNF canister behavior.

Carpenter-Graffy, Dina E.↗