Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHEMILUMINESCENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Improved Optical Fiber Chemical Sensors

Calculations, based on exact theory of optical fiber, have shown how to increase optical efficiency sensitivity of active-core, step-index-profile optical-fiber fluorosensor. Calculations result of efforts to improve efficiency of optical-fiber chemical sensor of previous concept described in "Making Optical-Fiber Chemical Sensors More Sensitive" (LAR-14525). Optical fiber chemical detector of enhanced sensitivity made in several configurations. Portion of fluorescence or chemiluminescence generated in core, and launched directly into bound electromagnetic modes that propagate along core to photodetector.

Egalon, Claudio O.↗

Peroxy radical measurements with NCAR's chemical amplifier

The present NCAR instrument for HO2/RO2 measurements has been described previously. It is based on the reactions involving HO2, RO2, and HO radicals with CO and NO. Since (HO2) + (RO2) + (HO) is much greater than (HO) for most atmospheres, it is useful as a peroxy radical detector. Operation of the instrument depends on the creation of a chemical chain reaction which is initiated as HO2 and RO2 radicals in ambient air encounter added NO gas; this forms an NO2 molecule and an HO or RO radical: HO2(RO2) + NO yields HO(RO) + NO2. RO radicals react relatively efficiently with O2 to form an HO2 radical, and subsequently an HO-radical, by reaction with NO. CO gas added to the reaction chamber during part of the operating cycle, recycles the HO to HO2; HO + CO (+O2) yields HO2 + CO2. The reaction sequence may form several hundred NO2 molecules per HO2 (RO2) originally present, before chain termination occurs. The added CO is replaced by N2 addition periodically so that the chain reaction is suppressed, and a 'blank' signal resulting from NO2, O3 and possibly other NO2-forming species (non-chain processes) in ambient air is recorded. The difference between the signal with and without CO is proportional to the peroxy radical concentration. The NO2 produced is monitored using a sensitive luminol chemiluminescence detector system. In the NCAR instrument the length of the amplification chain is determined using a stable source of HO2 radicals (H2O2 thermal decomposition); the ratio of the signal seen with CO present to that with N2 present gives the sensitivity of the instrument to HO2 (molecules of NO2 formed/peroxy radical). The instrument is automated to carry out in hourly repeated cycles: (1) chain length determination; (2) NO2 calibration; and (3) linearity check on the response of signals. One minute averages of signals are normally recorded. The sensitivity of the instrument to detect peroxy radicals is in the pptv range. The present instrument has operated continuously (24 hr/day) in the field studies which extended over a period of several weeks. The major advantages of this instrument are as follows: (1) its relative simplicity; (2) low power requirements; and (3) its rapid response to all types of peroxy radicals--HO2, CH3O2 and the higher alkyl and acyl peroxy radicals; however not all RO2 species generate HO2 radicals with perfect efficiency and hence have somewhat lower response/molecule than HO2 radicals.

Cantrell, Christopher↗

Laboratory kinetic studies of OH and CO2 relevant to upper atmospheric radiation balance

During the first year of this program, we have made considerable progress toward the measurement of the dipole moments of vibrationally excited OH radicals. Our primary accomplishments have been 1) the modification of the original slit jet spectrometer for the study of radical species and 2) the observation of infrared chemiluminescence from the vibrationally excited OH radicals formed in the H + ozone reaction in the supersonic jet. We are optimistic that we will soon observe OH* laser induced fluorescence in the jet. Modulation of this fluorescence with microwave radiation in an applied electric field will be the final step required for the precise determination of the vibrational dependence of the OH dipole moment.

Nelson, David D.↗

New photolysis system for NO2 measurements in the lower stratosphere

A new system for NO2 detection has been developed for use on the NASA ER-2 aircraft. The system converts NO2 to NO using UV photolysis with the NO product subsequently detected with an on-board chemiluminescence detector. The new system is compact, light weight, has high time resolution (approximately 1 s), and is significantly more efficient then some previous designs. Details of the system design and airborne performance are discussed.

Gao, R. S.↗

Electronic transition moment for the B(2)II-X(2)II system of NO

The upsilon' = 0-3 and 7 vibrational levels of the NO B(2)II state have been selectively excited by laser radiation. The fluorescence spectra together with calculated Franck-Condon factors and r-centroids have been used to evaluate the electronic transition moment. The results for upsilon' = 0-3 are in very good agreement with recent chemiluminescence measurements and ab initio calculations. Furthermore, the data from upsilon' = 7 have been used to extend the empirically determined moment to limits 1.23 and 1.78 A, improving agreement with experimentally determined lifetimes.

Luque, Jorge↗

Sensing strategies for toxic vapor detection

This work was motivated by the recommendations of the American Conference of Governmental Industrial Hygienists (ACGIH) that threshold limits for hydrazine, H2N-NH2 in air be lowered from 100 to 10 parts-per-billion (ppb) concentration levels. Hydrazine is one of the high-energy propellants used in large volumes in Space Shuttle, Titan, payloads, and other aerospace operations. Since analytical methods presently available for hydrazine detection and/or determination do not satisfy such low levels of detection, the ultimate goal of this research is the development and characterization of a portable and compact chemical sensor ideally capable to detect (in real time) 1 ppb of hydrazine, continuously and reversibly. The laboratory prototype developed as part of this project is comprised of: (1) a reactor part in which H2N-NH2 reacts, generating chemiluminescence emission, with tris(2,2'-bipyridine)ruthenium(III), which is immobilized on an ion-exchange polymeric materials of a perfluorinated hydrocarbon containing sulfonate groups as exchange centers (Nafion); (2) an electrochemical three-electrode cell posed at a potential at which the immobilized ruthenium complex could be reoxidized to the 3-oxidation state (as to provide reversible and continuous detection); and (3) a low power consumption photomultiplier tube to collect and quantitatively integrate the emitted photons with the help of auxiliary electronics and readout device.

Mottola, Horacio A.↗

Imaging of Combustion Species in a Radially-Staged Gas Turbine Combustor

Planar laser-induced fluorescence (PLIF) is used to characterize the complex flowfield of a unique fuel-lean, radially-staged, high pressure gas turbine combustor. PLIF images of OH are presented for two fuel injector configurations. PLIF images of NO, the first acquired at these conditions, are presented and compared with gas sample extraction probe measurements. Flow field imaging of nascent C2 chemiluminescence is also investigated. An examination is made of the interaction between adjoining lean premixed prevaporized (LPP) injectors. Fluorescence interferences at conditions approaching 2000 K and 15 atm are observed and attributed to polycyclic aromatic hydrocarbon (PAH) emissions. All images are acquired at a position immediately downstream of the fuel injectors with the combustor burning JP-5 fuel.

Locke, Randy J.↗

Imaging of Combustion Species in a Radially-Staged Gas Turbine Combustor

Plannar laser-induced fluorescence (PLIF) is used to characterize the complex flowfield of a unique fuel-lean, radially-staged high pressure gas turbine combustor. PLIF images of OH are presented for two fuel injector configurations. PLIF images of NO, the first acquired at these conditions, are presented and compared with gas sample extraction probe measurements. Flow field imaging of nascent C2 chemiluminescence is also investigated. An examination is made of the interaction between adjoining lean premixed prevaporized (LPP) injectors. Fluorescence interferences at conditions approaching 2000 K and 15 atm are observed and attributed to polycyclic aromatic hydrocarbon (PAH) emissions. All images are acquired at a position immediately downstream of the fuel injectors with combustor burning JP-5 fuel.

Locke, Randy J.↗

Quantitative PLIF Imaging in High-Pressure Combustion

This is the final report for a research project aimed at developing planar laser-induced fluorescence (PLIF) techniques for quantitative 2-D species imaging in fuel-lean, high-pressure combustion gases, relevant to modem aircraft gas turbine combustors. The program involved both theory and experiment. The theoretical activity led to spectroscopic models that allow calculation of the laser-induced fluorescence produced in OH, NO and 02 for arbitrary excitation wavelength, pressure, temperature, gas mixture and laser linewidth. These spectroscopic models incorporate new information on line- broadening, energy transfer and electronic quench rates. Extensive calculations have been made with these models in order to identify optimum excitation strategies, particularly for detecting low levels (ppm) of NO in the presence of large 02 mole fractions (10% is typical for the fuel-lean combustion of interest). A promising new measurement concept has emerged from these calculations, namely that excitation at specific wavelengths, together with detection of fluorescence in multiple spectral bands, promises to enable simultaneous detection of both NO (at ppm levels) and 02 or possibly NO, 02 and temperature. Calculations have been made to evaluate the expected performance of such a diagnostic for a variety of conditions and choices of excitation and detection wavelengths. The experimental effort began with assembly of a new high-pressure combustor to provide controlled high-temperature and high-pressure combustion products. The non-premixed burner enables access to postflame gases at high temperatures (to 2000 K) and high pressures (to 13 atm), and a range of fuel-air equivalence ratios. The chamber also allowed use of a sampling probe, for chemiluminescent detection of NO/NO2, and thermocouples for measurement of gas temperature. Experiments were conducted to confirm the spectroscopic models for OH, NO and 02.

Hanson, R. K.↗

Western Blot of Stained Proteins from Dried Polyacrylamide Gels

Western blotting of proteins is customarily performed following their separation on polyacrylamide gels, either prior to staining (1) or, as recently reported, following staining (2). We describe here Western blotting with stained gels, which had been dried and some of which had been stored for years. This procedure permits immunological analysis of proteins, to which antisera may have become available only later, or where the application of newly developed sensitive detection methods is desired. Once rehydration of the gels is achieved, proteins can be-transferred to blotting membranes by any appropriate protocol. Proteins stained with Coomassie Blue have to be detected with a non-chromogenic method, such as the film-based enhanced chemiluminescence (ECL)2) procedure (3). Silver stained proteins, which transfer in the colorless form, may be visualized by any detection method, although, because of the usually very low amounts of proteins, detection by ECL is preferable. Blotting of stained proteins from rehydrated gels is as rapid and as quantitative as from freshly prepared gels, in contrast to blotting from wet stained gels, which requires extensive washing and results in low transfer efficiency (2). Together with a photographic record of the gel pattern, unambiguous identification of immunoreactive proteins from complex mixtures is possible. Some further applications of this work are discussed.

Gruber, Claudia↗

The Effects of Buoyancy and Dilution on the Structure and Lift-off of Coflow Laminar Diffusion Flames

The ability to predict the coupled effects of complex transport phenomena with detailed chemical kinetics in diffusion flames is critical in the modeling of turbulent reacting flows and in understanding the processes by which soot formation and radiative transfer take place. In addition, an understanding of the factors that affect flame extinction in diffusion flames is critical in the suppression of fires and in improving engine efficiency. The goal of our characterizations of coflow laminar diffusion flames is to bring to microgravity the multidimensional diagnostic tools available in normal gravity, and in so doing provide a broader understanding of the successes and limitations of current combustion models. This will lead to a more detailed understanding of the interaction of convection, diffusion and chemistry in both buoyant and nonbuoyant environments. As a sensitive marker of changes in the flame shape, the number densities of excited-state CH (A(exp 2)delta, denoted CH*), and excited-state OH (A(exp 2)Sigma, denoted OH*) are measured in mu-g and normal gravity. Two-dimensional CH* and OH* number densities are deconvoluted from line-of-sight chemiluminescence measurements made on the NASA KC-135 reduced-gravity aircraft. Measured signal levels are calibrated, post-flight, with Rayleigh scattering. Although CH* and OH* kinetics are not well understood, the CH*, OH*, and ground-state CH distributions are spatially coincident in the flame anchoring region. Therefore, the ground-state CH distribution, which is easily computed, and the readily measured CH*/OH* distributions can be used to provide a consistent and convenient way of measuring lift-off height and flame shape in the diffusion flame under investigation. Given that the fuel composition affects flame chemistry and that buoyancy influences the velocity profile of the flow, we have the opportunity to computationally and experimentally study the roles of fluids and chemistry. In performing this microgravity study, improvements to the computational model have been made and new calculations performed for a range of gravity and flow conditions. Furthermore, modifications to the experimental approach were required as a consequence of the constraints imposed by existing microgravity facilities. Results from the computations and experiments are presented in the following sections.

Walsh, Kevin T.↗

The Effects of Buoyancy and Dilution on the Structure and Lift-Off of Coflow Laminar Diffusion Flames

The ability to predict the coupled effects of complex transport phenomena with detailed chemical kinetics in diffusion flames is critical in the modeling of turbulent reacting flows and in understanding the processes by which soot formation and radiative transfer take place. In addition, an understanding of those factors that affect flame extinction in diffusion flames is critical in the suppression of fires and in improving engine efficiency. A goal of this work is to bring to microgravity flame studies the detailed experimental and numerical tools that have been used to study ground-based systems. This will lead to a more detailed understanding of the interaction of convection, diffusion and chemistry in a nonbuoyant environment. To better understand these phenomena, experimental and computational studies of a coflow laminar diffusion flame have been carried out. To date, these studies have focused on a single set of flow conditions, in which a nitrogen-diluted methane fuel stream (65% methane by volume) was surrounded by an air coflow, with exit velocities matched at 35 cm/s. Of particular interest is the change in flame shape due to the absence of buoyant forces, as well as the amount of diluent in the fuel stream and the coflow velocity. As a sensitive marker of changes in the flame shape, the number densities of excited-state CH (A(exp 2 delta) denoted CH*), and excited-state OH (A(exp 2 sigma, denoted OH*) are measured. CH* and OH* number densities are deconvoluted from line-of-sight chemiluminescence measurements made on the NASA KC135 reduced-gravity aircraft. Measured signal levels are calibrated, post-flight, with Rayleigh scattering. In extending the study to microgravity conditions, improvements to the computational model have been made and new calculations performed for a range of gravity conditions. In addition, modifications to the experimental approach were required as a consequence of the constraints imposed by existing microgravity facilities. Results from the computations and experiments are presented.

Walsh, Kevin T.↗

THz Spectroscopy of the Atmosphere

THz spectroscopy of the atmosphere has been driven by the need to make remote sensing measurements of OH. While the THz region can be used for sensitive detection on many atmospheric molecules, the THz region is the best region for measuring the diurnal behavior of stratospheric OH by remote sensing. The infrared region near 3 microns suffers from chemiluminescence and from spectral contamination due to water. The ultraviolet region near 300 nm requires solar illumination. The three techniques for OH emission measurements in the THz region include Fourier Transform interferometry, Fabry-Perot interferometry, and heterodyne radiometry. The first two use cryogenic direct detectors while the last technique uses a local oscillator and a mixer to down convert the THz signal to GHz frequencies. All techniques have been used to measure stratospheric OH from balloon platforms. OH results from the Fabry-Perot based FILOS instrument will be given. Heterodyne measurement of OH at 2.5 THz has been selected to be a component of the Microwave Limb Sounder on the Earth Observing System CHEM-1 polar satellite. The design of this instrument will be described. A balloon-based prototype heterodyne 2.5 THz radiometer had its first flight on, 24 May 1998. Results form this flight will be presented.

Pickett, Herbert M.↗

Airborne Measurements of Nitric Oxide, Nitrogen Dioxide, Ozone, and Total Reactive Nitrogen During the NASA Global Tropospheric Experiment

Fabrication of the University of Michigan Multichannel Chemiluminescence Instrument (UMMCI) was completed in early 1996 and the instrument participated in test flights on the NASA P3B at Wallops Island prior to integration and deployment for the PEM- Tropics A Mission. The UMMCI consists of 4 channels for simultaneous measurements of ozone and NO with the option for measurements of NO2 and NOy (total reactive nitrogen) when converters are placed upstream of the NO channels. Each NO channel consists of a zeroing volume and reaction vessel, while the ozone channel consists of an ozone catalyst (or scrubber) trap that is not in line with the reaction vessel. The detectors in all for channels are Hamamatsu photomultiplier tubes, which are followed by pulse amplifier discriminators on the NO channels and an electrometer on the ozone channel. Schematics of the Detector Module and NOx/03 Probe Insert and Diagrams of the Control and Data System, the Power and Ground System, the Gas Flow System, and the Calibration System Flow are attached. Intercomparisons were conducted with G. Gregory, NASA/Langley, during the test flights (following prior calibration of the ozone generator/calibrators at the Wallops Long-Path Absorption facility). Initial test results appeared to be reasonable, and instrument characterization studies proceeded for the ozone channel and the 3 NO channels until deployment for integration for the PEM-Tropics Mission. Ozone data was obtained for Flights #4, and 6-2 1, and finalized data was submitted to the PEM-Tropics Data Archive and to the Science Team during the April 1997 Data Workshop. Although it initially appeared that the instrument sensitivity varied, subsequent tests showed that this was the fault of a leak in the ozone calibrator. In fact; the instrument sensitivity has not been observed to vary in a large number of tests over the years since the PEM-Tropics mission. We have, therefore, a very high degree of confidence in the O3 data that we submitted. NO data was obtained for all flights except the mission out of Christmas Island and the subsequent return to Hawaii, during which time the NO channels were contaminated with back-flushing pure NO from the O3 channel. The NO channels were found to suffer from a varying artifact (7 - 22 pptv) which made the instrument's results unreliable for the marine boundary layer portions of the missions (where conditions were extremely clean with NO typically < 2 pptv and O3 only 8 ppbv). Nonetheless, the NO values were an upper limit and were quite useful in identifying pollution layers and outflow from the Latin American Continent. NO data was submitted to the archive for all flights during which data was obtained. Ozone data from the P3B was among the results presented in several peer-reviewed publications. Notably, the ozone data supported the first published finding of evidence for the occurrence of aerosol nucleation in the marine boundary layer. As well, the ozone data was utilized in a treatment of the wavenumber spectra of winds, temperature and trace gases and to demonstrate the occurrence of layering as observed by the P3B during PEM-Tropics A . O3 and NO data were used in an assessment of the impact of southern hemispheric biomass burning, and in the role of NOx and O3 in HOx photochemistry during the PEM Tropics A mission. These data, along with other species measured during PEM-Tropics A, have also been employed in the generation of climatologies for tropospheric ozone and its precursors by the PI's research group.

Carroll, Mary Anne↗

The Dynamical Evolution of A Tubular Leonid Persistent Train

The dynamical evolution of the persistent train of a bright Leonid meteor was examined for evidence of the source of the luminosity and the physical conditions in the meteor path. The train consisted of two parallel somewhat diffuse luminous tracks, interpreted as the walls of a tube. A general lack of wind shear along the trail allowed these structures to remain intact for nearly 200 s, from which it was possible to determine that the tubular structure expanded at a near constant 10.5 m/s, independent of altitude between 86 and 97 km. An initial fast decrease of train intensity below 90 km was followed by an increase in intensity and then a gradual decrease at longer times, whereas at high attitudes the integrated intensity was nearly constant with time. These results are compared to a model that describes the dynamical evolution of the train by diffusion, following an initial rapid expansion of the hot gaseous trail behind the meteoroid. The train luminosity is produced by O ((sup 1)S) emission at 557 nm, driven by elevated atomic O levels produced by the meteor impact, as well as chemiluminescent reactions of the ablated metals Na and Fe with O3. Ozone is rapidly removed within the train, both by thermal decomposition and catalytic destruction by the metallic species. Hence, the brightest emission occurs at the edge of the train between outwardly diffusing metallic species and inwardly diffusing O3. Although the model is able to account plausibly for a number of characteristic features of the train evolution, significant discrepancies remain that cannot easily be resolved.

Jenniskens, Peter↗

Theoretical Dipole Moment for the X211 State of NO

The dipole moment function for the X(sup 2)II state of NO is studied as a function of the completeness in both the one- and n-particle spaces. Einstein coefficients are presented that are significantly more accurate than previous tabulations for the higher vibrational levels. The theoretical values give considerable insight into the limitations of recently published ratios of Einstein coefficients measured by spectrally resolved infrared chemiluminescence.

Langhoff, Stephen R.↗

A Treatment of Measurements of Heptane Droplet Combustion Aboard MSL-1

Results of measurements on the burning of free n-heptane droplets (that is, droplets without fiber supports) performed in Spacelab during the flights of the first Microgravity Science Laboratory (MSL-1) are presented. The droplet combustion occurred in oxidizing atmospheres which were at an ambient temperature within a few degrees of 300 K. A total of 34 droplets were burned in helium-oxygen atmospheres having oxygen mole fractions ranging from 20 to 50 percent, at pressures from 0.25 to 1.00 bar. In addition, four droplets were burned in air at 1.00 bar, bringing the total number of droplets for which combustion data were secured to 38; two of these four air tests were fiber-supported to facilitate comparisons with other fiber-support experiments, results of which also are given here. Initial diameters of free droplets ranged from about 1 to 4 mm. The primary data obtained were histories of droplet diameters, recorded in backlight on 35 mm film at 80 frames per second, and histories of flame diameters, inferred from emissions through a narrow-band interference filter centered at the 310 micron OH chemiluminescent ultraviolet band, recorded at 30 frames per second by a intensified-array camera. These data are reported here both in raw form and in a smoothed form with estimated error bars. In addition, summaries are presented of measured burning-rate constants, final droplet diameters, and final flame diameters. Both diffusive and radiative extinctions were exhibited under different conditions. Although some interpretations are reported and conclusions drawn concerning the combustion mechanisms, the principal intent of this report is to provide a complete, documented data set for future analysis.

Ackerman, M. D.↗

Experiments And Model Development For The Investigation Of Sooting And Radiation Effects In Microgravity Droplet Combustion

This study involves flight experiments (for droplets between 1.5 to 5 mm) and supportive ground-based experiments, with concurrent numerical model development and validation. The experiments involve two fuels: n-heptane, and ethanol. The diagnostic measurements include light extinction for soot volume fraction, two-wavelength pyrometry and thin-filament pyrometry for temperature, spectral detection for OH chemiluminescence, broadband radiometry for flame emission, and thermophoretic sampling with subsequent transmission electron microscopy for soot aerosol property calculations.

Yozgatligil, Ahmet↗