Search NASA⌕ Search

SEARCH · Search NASA

Results for “CI testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The relationship between stress, anxiety and eating behavior among Chinese students: a cross-sectional study

Background The expansion of higher education and the growing number of college students have led to increased awareness of mental health issues such as stress, anxiety, and eating disorders. In China, the educational system and cultural expectations contribute to the stress experienced by college students. This study aims to clarify the role of anxiety as a mediator in the relationship between stress and eating behaviors among Chinese college students. Methods This study utilized data from the 2021 Psychology and Behavior Investigation of Chinese Residents, which included 1,672 college students under the age of 25. The analysis methods comprised descriptive statistics, t -tests, Pearson correlation analyses, and mediation effect analysis. Results The findings indicate that Chinese college students experience high levels of stress, with long-term stress slightly exceeding short-term stress. Both types of stress were positively correlated with increased anxiety and the adoption of unhealthy eating behaviors. Anxiety was identified as a significant mediator, accounting for 28.3% of the relationship between long-term stress and eating behavior (95% CI = 0.058–0.183). The mediation effect of short-term stress on eating behavior through anxiety was also significant, explaining 61.4% of the total effect (95% CI = 0.185–0.327). Conclusion The study underscores the importance of stress management and mental health services for college students. It recommends a comprehensive approach to reducing external pressures, managing anxiety, and promoting healthy eating behaviors among college students. Suggestions include expanding employment opportunities, providing career guidance, enhancing campus and societal support for holistic development, strengthening mental health services, leveraging artificial intelligence technologies, educating on healthy lifestyles, and implementing targeted health promotion programs.

Chai, Yulin↗

Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm{sup 3} and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histologic Subtype in Core Lung Biopsies of Early-Stage Lung Adenocarcinoma is a Prognostic Factor for Treatment Response and Failure Patterns After Stereotactic Body Radiation Therapy

Purpose: Stereotactic body radiation therapy (SBRT) has emerged as an effective treatment for early-stage lung cancer. The histologic subtype of surgically resected lung adenocarcinoma is recognized as a prognostic factor, with the presence of solid or micropapillary patterns predicting poor outcomes. We describe the outcomes after SBRT for early-stage lung adenocarcinoma stratified by histologic subtype. Methods and Materials: We identified 119 consecutive patients (124 lesions) with stage I to IIA lung adenocarcinoma who had undergone definitive SBRT at our institution from August 2008 to August 2015 and had undergone core biopsy. Histologic subtyping was performed according to the 2015 World Health Organization classification. Of the 124 tumors, 37 (30%) were a high-risk subtype, defined as containing a component of solid and/or micropapillary pattern. The cumulative incidences of local, nodal, regional, and distant failure were compared between the high-risk and non–high-risk adenocarcinoma subtypes using Gray's test, and multivariable-adjusted hazard ratios (HRs) were estimated from propensity score–weighted Cox regression models. Results: The median follow-up for the entire cohort was 17 months and for surviving patients was 21 months. The 1-year cumulative incidence of and adjusted HR for local, nodal, regional, and distant failure in high-risk versus non–high-risk lesions was 7.3% versus 2.7% (HR 16.8; 95% confidence interval [CI] 3.5-81.4), 14.8% versus 2.6% (HR 3.8; 95% CI 0.95-15.0), 4.0% versus 1.2% (HR 20.9; 95% CI 2.3-192.3), and 22.7% versus 3.6% (HR 6.9; 95% CI 2.2-21.1), respectively. No significant difference was seen with regard to overall survival. Conclusions: The outcomes after SBRT for early-stage adenocarcinoma of the lung correlate highly with histologic subtype, with micropapillary and solid tumors portending significantly higher rates of locoregional and metastatic progression. In this context, the histologic subtype determined from core biopsies is a prognostic factor and could have important implications for patient selection, adjuvant treatment, biopsy methods, and clinical trial design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Radiation Treatment Time on Survival in Patients With Head and Neck Cancer

Purpose: To assess the impact of radiation treatment time (RTT) in head and neck cancers on overall survival (OS) in the era of chemoradiation. Methods and Materials: Patients with diagnoses of tongue, hypopharynx, larynx, oropharynx, or tonsil cancer were identified by use of the National Cancer Database. RTT was defined as date of first radiation treatment to date of last radiation treatment. In the definitive setting, prolonged RTT was defined as >56 days, accelerated RTT was defined as <47 days, and standard RTT was defined as 47 to 56 days. In the postoperative setting, prolonged RTT was defined as >49 days, accelerated RTT was defined as <40 days, and standard RTT was defined as 40 to 49 days. We used χ{sup 2} tests to identify predictors of RTT. The Kaplan-Meier method was used to compare OS among groups. Cox proportional hazards model was used for OS analysis in patients with known comorbidity status. Results: 19,531 patients were included; 12,987 (67%) had a standard RTT, 4,369 (34%) had an accelerated RTT, and 2,165 (11%) had a prolonged RTT. On multivariable analysis, accelerated RTT (hazard ratio [HR] 0.84; 95% confidence interval [CI] 0.73-0.97) was associated with an improved OS, and prolonged RTT (HR 1.25; 95% CI 1.14-1.37) was associated with a worse OS relative to standard RTT. When the 9,200 (47%) patients receiving definitive concurrent chemoradiation were examined, prolonged RTT (HR 1.29; 95% CI 1.11-1.50) was associated with a worse OS relative to standard RTT, whereas there was no significant association between accelerated RTT and OS (HR 0.76; 95% CI 0.57-1.01). Conclusion: Prolonged RTT is associated with worse OS in patients receiving radiation therapy for head and neck cancer, even in the setting of chemoradiation. Expeditious completion of radiation should continue to be a quality metric for the management of head and neck malignancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Spiral Bevel Gear Condition Indicator Validation via AC-29-2C Using Fielded Rotorcraft HUMS Data

This report presents the analysis of gear condition indicator data collected on a helicopter when damage occurred in spiral bevel gears. The purpose of the data analysis was to use existing in-service helicopter HUMS flight data from faulted spiral bevel gears as a Case Study, to better understand the differences between HUMS data response in a helicopter and a component test rig, the NASA Glenn Spiral Bevel Gear Fatigue Rig. The reason spiral bevel gear sets were chosen to demonstrate differences in response between both systems was the availability of the helicopter data and the availability of a test rig that was capable of testing spiral bevel gear sets to failure. The objective of the analysis presented in this paper was to re-process helicopter HUMS data with the same analysis techniques applied to the spiral bevel rig test data. The damage modes experienced in the field were mapped to the failure modes created in the test rig. A total of forty helicopters were evaluated. Twenty helicopters, or tails, experienced damage to the spiral bevel gears in the nose gearbox. Vibration based gear condition indicators data was available before and after replacement. The other twenty tails had no known anomalies in the nose gearbox within the time frame of the datasets. These twenty tails were considered the baseline dataset. The HUMS gear condition indicators evaluated included gear condition indicators (CI) Figure of Merit 4 (FM4), Root Mean Square (RMS) or Diagnostic Algorithm 1 (DA1) and +/- 3 Sideband Index (SI3). Three additional condition indicators, not currently calculated on-board, were calculated from the archived data. These three indicators were +/- 1 Sideband Index (SI1), the DA1 of the difference signal (DiffDA1) and the peak-to-peak of the difference signal (DP2P). Results found the CI DP2P, not currently available in the on-board HUMS, performed the best, responding to varying levels of damage on thirteen of the fourteen helicopters evaluated. Two additional CIs also not in the on-board system, DiffDA1and SI1, also performed well responding to twelve and ten of the fourteen helicopters evaluated respectively. Of the three CIs currently available in the MSPU, DA1, FM4 and SI3, SI3, responded to eight, DA1 responded to six and FM4 responded to four of the fourteen helicopters evaluated. FM4, the poorest performing CI, was not as responsive to damage as the other five CIs. Conversely, when compared to the other two, it was the only CI that responded to damage on two helicopters. CI response could not be correlated to specific failure modes due to limited pictures and subjective descriptions found within the TDA. Flight regime did affect CI response to some gear faults. Due to the range of operating conditions for each regime, more studies are required to determine their sensitivity to regimes.

rotorcraft↗

Analysis of implant loss risk factors after simultaneous guided bone regeneration: A retrospective study of 5404 dental implants

Abstract Purpose The purpose was to analyze the risk factors for implant loss after simultaneous guided bone regeneration (GBR). Materials and Methods Patients who underwent implant placement with simultaneous GBR between January 2011 and December 2018 were screened for this study. The cumulative survival rate (CSR) was calculated using the life table method. Log‐rank test and Kaplan–Meier survival estimates were used to identify potential risk factors for implant loss. The association between the investigated variables and implant loss was determined using hazard ratios (HRs) obtained from a multivariate Cox regression analysis. Results A total of 3973 patients with 5404 implants were included in this study. The CSRs of the implants at 1, 5, and 10 years were 99.6%, 98.9%, and 98.7%, respectively. Male patient (HR = 2.94, 95% CI: 1.41–6.14), periodontitis (HR = 4.26, 95% CI: 2.05–9.86), tissue‐level implants (HR = 3.02, 95% CI: 1.30–6.98), narrow implants (HR = 2.71, 95% CI: 1.12–6.57), and implant length ≤10 mm (HR = 2.91, 95% CI: 1.41–6.02) significantly increased the risk of implant loss ( p < 0.05). The risk of implant loss was significantly higher in the maxillary posterior region (HR = 2.26, 95% CI: 1.04–4.90) than in the maxillary anterior region ( p < 0.05). Compared to Straumann, Nobel (HR = 4.07, 95% CI: 1.75–9.44) and other implant systems (HR = 14.23, 95% CI: 4.32–46.85) showed a significantly higher risk of implant loss ( p < 0.05). Conclusion Male patient, periodontitis, maxillary posterior region, Nobel implant system, other implant systems, tissue‐level implants, narrow implants, and implant length ≤10 mm were considered risk factors for implant loss after simultaneous GBR.

Shen, Xiaoting↗

The Interplay Between Strategic And Adaptive Control Mechanisms In Plastic Recalibration Of Locomotor Function

We have previously shown that viewing simulated rotary self-motion during treadmill locomotion causes immediate strategic modifications (Richards et al. 2004) as well as an after effect reflecting adaptive modification of the control of position and trajectory during over-ground locomotion (Mulavara et al. 2005). The process of sensorimotor adaptation is comprised of both strategic and adaptive control mechanisms. Strategic control involves cognitive, on-line corrections to limb movements once one is aware of a sensory discordance. Over an extended period of exposure to the sensory discordance, new strategic sensorimotor coordination patterns are reinforced until they become more automatic, and therefore adaptive, in nature. The objective of this study was to investigate how strategic changes in trunk control during exposure to simulated rotary self-motion during treadmill walking influences adaptive modification of locomotor heading direction during over-ground stepping. Subjects (n = 10) walked on a motorized linear treadmill while viewing a wide field-of-view virtual scene for 24 minutes. The scene was static for the first 4 minutes and then, for the last 20 minutes, depicted constant rate self-motion equivalent to walking in a counter-clockwise, circular path around the perimeter of a room. Subjects performed five stepping trials both before and after the exposure period to assess after effects. Results from our previous study showed a significant change in heading direction (HD) during post-exposure step tests that was opposite the direction in which the scene rotated during the adaptation period. For the present study, we quantified strategic modifications in trunk movement control during scene exposure using normalized root mean square (R(sub p)) variation of the subject's 3D trunk positions and normalized sum of standard deviations (R(sub o)) variation of 3D trunk orientations during scene rotation relative to that during static scene presentation. Associated 95% confidence intervals, CI(sub P) and CI(sub O), were calculated to investigate the variation of strategic modifications during scene exposure. Repeated measures ANOVA and individual subject regression analyses showed that R(sub P) and R(sub O) (i.e. strategic modifications) for trunk fore/aft (X) and yaw movements, respectively, decreased significantly over the exposure period. Furthermore, we found a significant correlation between the magnitude change in HD and the rate at which the variation of strategic modifications in trunk X decreased. We also found evidence of a correlation between HD and the rate at which strategic modifications in trunk yaw decreased (p = .06). We infer that adaptive recalibration of locomotor trajectory using optic flow stimuli depends on the rate at which strategic intervention is reduced.

Richards, J. T.↗

Self-healing SEI enables full-cell cycling of a silicon-majority anode with a coulombic efficiency exceeding 99.9%

Despite active developments, full-cell cycling of Li-battery anodes with >50 wt% Si (a Si-majority anode, SiMA) is rare. The main challenge lies in the solid electrolyte interphase (SEI), which when formed naturally (nSEI), is fragile and cannot tolerate the large volume changes of Si during lithiation/delithiation. An artificial SEI (aSEI) with a specific set of mechanical characteristics is henceforth designed; we enclose Si within a TiO 2 shell thinner than 15 nm, which may or may not be completely hermetic at the beginning. In situ TEM experiments show that the TiO 2 shell exhibits 5× greater strength than an amorphous carbon shell. Void-padded compartmentalization of Si can survive the huge volume changes and electrolyte ingression, with a self-healing aSEI + nSEI. The half-cell capacity exceeds 990 mA h g -1 after 1500 cycles. To improve the volumetric capacity, we further compress SiMA 3-fold from its tap density (0.4 g cm -3 ) to 1.4 g cm -3 , and then run the full-cell battery tests against a 3 mA h cm -2 LiCoO 2 cathode. Despite some TiO 2 enclosures being inevitably broken, 2× the volumetric capacity (1100 mA h cm -3 ) and 2× the gravimetric capacity (762 mA h g -1 ) of commercial graphite anode is achieved in stable full-cell battery cycling, with a stabilized areal capacity of 1.6 mA h cm -2 at the 100th cycle. The initial lithium loss, characterized by the coulombic inefficiency (CI), is carefully tallied on a logarithmic scale and compared with the actual full-cell capacity loss. In conclusion, it is shown that a strong, non-adherent aSEI, even if partially cracked, facilitates an adaptive self-repair mechanism that enables full-cell cycling of a SiMA, leading to a stabilized coulombic efficiency exceeding 99.9%.

25 ENERGY STORAGE↗

Younger facial looks are associate with a lower likelihood of several age-related morbidities in the middle-aged to elderly

Abstract Background Looking older for one’s chronological age is associated with a higher mortality rate. Yet it remains unclear how perceived facial age relates to morbidity and the degree to which facial ageing reflects systemic ageing of the human body. Objectives To investigate the association between ΔPA and age-related morbidities of different organ systems, where ΔPA represents the difference between perceived age (PA) and chronological age. Methods We performed a cross-sectional analysis on data from the Rotterdam Study, a population-based cohort study in the Netherlands. High-resolution facial photographs of 2679 men and women aged 51.5–87.8 years of European descent were used to assess PA. PA was estimated and scored in 5-year categories using these photographs by a panel of men and women who were blinded for chronological age and medical history. A linear mixed model was used to generate the mean PAs. The difference between the mean PA and chronological age was calculated (ΔPA), where a higher (positive) ΔPA means that the person looks younger for their age and a lower (negative) ΔPA that the person looks older. ΔPA was tested as a continuous variable for association with ageing-related morbidities including cardiovascular, pulmonary, ophthalmological, neurocognitive, renal, skeletal and auditory morbidities in separate regression analyses, adjusted for age and sex (model 1) and additionally for body mass index, smoking and sun exposure (model 2). Results We observed 5-year higher ΔPA (i.e. looking younger by 5 years for one’s age) to be associated with less osteoporosis [odds ratio (OR) 0.76, 95% confidence interval (CI) 0.62–0.93], less chronic obstructive pulmonary disease (OR 0.85, 95% CI 0.77–0.95), less age-related hearing loss (model 2; B = −0.76, 95% CI −1.35 to −0.17) and fewer cataracts (OR 0.84, 95% CI 0.73–0.97), but with better global cognitive functioning (g-factor; model 2; B = 0.07, 95% CI 0.04–0.10). Conclusions PA is associated with multiple morbidities and better cognitive function, suggesting that systemic ageing and cognitive ageing are, to an extent, externally visible in the human face.

Mekić, Selma↗

Aircraft in-situ measurements from SOCRATES constrain the anthropogenic perturbations of cloud droplet number

Aerosol-cloud interactions (ACI) in warm clouds alter reflected shortwave radiation by influencing cloud microphysical and macrophysical properties. The variable of state controlling ACI is the cloud droplet number concentration (N d ). Here, we examine the perturbations in N d due to anthropogenic aerosols (ΔN d, PD-PI ) using a perturbed parameter ensemble (PPE) hosted in the sixth Community Atmosphere Model (CAM6). Surrogate models are created for the CAM6 PPE outputs and are used to generate 1 million model variants of CAM6 by sampling 45 sources of parameter uncertainty. The range of uncertain physical parameters related to ACI are constrained with observations of aerosol and cloud properties from SOCRATES. The likely range of uncertain parameters and the associated range of ΔN d, PD-PI are more strongly constrained with observations of N d relative to observations of cloud condensation nuclei. We conduct sensitivity tests of how constraints on ΔN d, PD-PI are affected by systematic uncertainties in observations and our limitations in our surrogate models created for CAM6 PPE outputs. Based on this, we provide guidance on the impact of reducing systematic uncertainty in airborne microphysical observations and in surrogate models.

Song, Ci [Univ. of Wyoming, Laramie, WY (United St↗

Effects of Wind Energy Development on Nesting Ecology of Greater Prairie-Chickens in Fragmented Grasslands: Wind Power and Prairie-Chickens

Wind energy is targeted to meet 20% of U.S. energy needs by 2030, but new sites for development of renewable energy may overlap with important habitats of declining populations of grassland birds. Greater Prairie-Chickens (Tympanuchus cupido) are an obligate grassland bird species predicted to respond negatively to energy development. We used a modified before–after control–impact design to test for impacts of a wind energy development on the reproductive ecology of prairie-chickens in a 5-year study. We located 59 and 185 nests before and after development, respectively, of a 201 MW wind energy facility in Greater Prairie-Chicken nesting habitat and assessed nest site selection and nest survival relative to proximity to wind energy infrastructure and habitat conditions. Proximity to turbines did not negatively affect nest site selection (β = 0.03, 95% CI = -1.2–1.3) or nest survival (β = -0.3, 95% CI = -0.1). Instead, nest site selection and survival were strongly related to vegetative cover and other local conditions determined by management for cattle production. Integration of our project results with previous reports of behavioral avoidance of oil and gas facilities by other species of prairie grouse suggests new avenues for research to mitigate impacts of energy development.

54 ENVIRONMENTAL SCIENCES↗

xMDFF: molecular dynamics flexible fitting of low-resolution X-ray structures

A new real-space refinement method for low-resolution X-ray crystallography is presented. The method is based on the molecular dynamics flexible fitting protocol targeted at addressing large-scale deformations of the search model to achieve refinement with minimal manual intervention. An explanation of the method is provided, augmented by results from the refinement of both synthetic and experimental low-resolution data, including an independent electrophysiological verification of the xMDFF-refined crystal structure of a voltage-sensor protein. X-ray crystallography remains the most dominant method for solving atomic structures. However, for relatively large systems, the availability of only medium-to-low-resolution diffraction data often limits the determination of all-atom details. A new molecular dynamics flexible fitting (MDFF)-based approach, xMDFF, for determining structures from such low-resolution crystallographic data is reported. xMDFF employs a real-space refinement scheme that flexibly fits atomic models into an iteratively updating electron-density map. It addresses significant large-scale deformations of the initial model to fit the low-resolution density, as tested with synthetic low-resolution maps of d-ribose-binding protein. xMDFF has been successfully applied to re-refine six low-resolution protein structures of varying sizes that had already been submitted to the Protein Data Bank. Finally, via systematic refinement of a series of data from 3.6 to 7 Å resolution, xMDFF refinements together with electrophysiology experiments were used to validate the first all-atom structure of the voltage-sensing protein Ci-VSP.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

National Cancer Database Analysis of Proton Versus Photon Radiation Therapy in Non-Small Cell Lung Cancer

Purpose: To analyze outcomes and predictors associated with proton radiation therapy for non-small cell lung cancer (NSCLC) in the National Cancer Database. Methods and Materials: The National Cancer Database was queried to capture patients with stage I-IV NSCLC treated with thoracic radiation from 2004 to 2012. A logistic regression model was used to determine the predictors for utilization of proton radiation therapy. The univariate and multivariable association with overall survival were assessed by Cox proportional hazards models along with log–rank tests. A propensity score matching method was implemented to balance baseline covariates and eliminate selection bias. Results: A total of 243,822 patients (photon radiation therapy: 243,474; proton radiation therapy: 348) were included in the analysis. Patients in a ZIP code with a median income of <$46,000 per year were less likely to receive proton treatment, with the income cohort of $30,000 to $35,999 least likely to receive proton therapy (odds ratio 0.63 [95% confidence interval (CI) 0.44-0.90]; P=.011). On multivariate analysis of all patients, non-proton therapy was associated with significantly worse survival compared with proton therapy (hazard ratio 1.21 [95% CI 1.06-1.39]; P<.01). On propensity matched analysis, proton radiation therapy (n=309) was associated with better 5-year overall survival compared with non-proton radiation therapy (n=1549), 22% versus 16% (P=.025). For stage II and III patients, non-proton radiation therapy was associated with worse survival compared with proton radiation therapy (hazard ratio 1.35 [95% CI 1.10-1.64], P<.01). Conclusions: Thoracic radiation with protons is associated with better survival in this retrospective analysis; further validation in the randomized setting is needed to account for any imbalances in patient characteristics, including positron emission tomography–computed tomography staging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive time steps in trajectory surface hopping simulations

Trajectory surface hopping (TSH) simulations are often performed in combination with active-space multi-reference configuration interaction (MRCI) treatments. Technical problems may arise in such simulations if active and inactive orbitals strongly mix and switch in some particular regions. We propose to use adaptive time steps when such regions are encountered in TSH simulations. For this purpose, we present a computational protocol that is easy to implement and increases the computational effort only in the critical regions. We test this procedure through TSH simulations of a GFP chromophore model (OHBI) and a light-driven rotary molecular motor (F-NAIBP) on semiempirical MRCI potential energy surfaces, by comparing the results from simulations with adaptive time steps to analogous ones with constant time steps. For both test molecules, the number of successful trajectories without technical failures rises significantly, from 53% to 95% for OHBI and from 25% to 96% for F-NAIBP. The computed excited-state lifetime remains essentially the same for OHBI and increases somewhat for F-NAIBP, and there is almost no change in the computed quantum efficiency for internal rotation in F-NAIBP. We recommend the general use of adaptive time steps in TSH simulations with active-space CI methods because this will help to avoid technical problems, increase the overall efficiency and robustness of the simulations, and allow for a more complete sampling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-C-9A-04: Alternative Analytic Solution to the Paralyzable Detector Model to Calculate Deadtime and Deadtime Loss

Purpose: Some common methods to solve for deadtime are (1) dual-source method, which assumes two equal activities; (2) model fitting, which requires multiple acquisitions as source decays; and (3) lossless model, which assumes no deadtime loss at low count rates. We propose a new analytic alternative solution to calculate deadtime for paralyzable gamma camera. Methods: Deadtime T can be calculated analytically from two distinct observed count rates M1 and M2 when the ratio of the true count rates alpha=N2/N1 is known. Alpha can be measured as a ratio of two measured activities using dose calibrators or via radioactive decay. Knowledge of alpha creates a system with 2 equations and 2 unknowns, i.e., T and N1. To verify the validity of the proposed method, projections of a non-uniform phantom (4GBq 99mTc) were acquired in using Siemens SymbiaS multiple times over 48 hours. Each projection has >100kcts. The deadtime for each projection was calculated by fitting the data to a paralyzable model and also by using the proposed 2-acquisition method. The two estimates of deadtime were compared using the Bland-Altmann method. In addition, the dependency of uncertainty in T on uncertainty in alpha was investigated for several imaging conditions. Results: The results strongly suggest that the 2-acquisition method is equivalent to the fitting method. The Bland-Altman analysis yielded mean difference in deadtime estimate of ∼0.076us (95%CI: -0.049us, 0.103us) between the 2-acquisition and model fitting methods. The 95% limits of agreement were calculated to be -0.104 to 0.256us. The uncertainty in deadtime calculated using the proposed method is highly dependent on the uncertainty in the ratio alpha. Conclusion: The 2-acquisition method was found to be equivalent to the parameter fitting method. The proposed method offers a simpler and more practical way to analytically solve for a paralyzable detector deadtime, especially during physics testing.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-510: Single Isocenter Radiosurgery for the Simultaneous Treatment of Multiple Brain Metastases: Volumetric Modulated Arc Therapy Or Dynamic Conformal Arc?

Purpose: This study evaluates a novel algorithm that can be used with any treatment planning system for simple and rapid generation of stereotactic radiosurgery (SRS) plans for treating multiple brain metastases using a single isocenter dynamic conformal arc (DCA) approach. This technique is compared with a single isocenter volumetric modulated arc therapy (VMAT) technique in terms of delivery time, conformity, low dose spread and delivery accuracy. Methods: Five patients, with a total of 37 (5 – 11) targets were planned using a previously published method for generating optimal VMAT plans and using the proposed DCA algorithm. All planning target volumes (PTVs) were planned to 20 Gy, meeting a minimum 99% coverage and maximum 135 % hot spot for both techniques. Quality assurance was performed using radiochromic film, with films placed in the high dose regions of each PTV. Normal tissue volumes receiving 12 Gy and 6 Gy (V12 and V6) were computed for each plan. Conformity index (CI) and gamma evaluations (95% of points passing 4%/0.5mm) were computed for each PTV. Results: Delivery times, including beam on and table rotation times, were comparable: 17 – 22 minutes for all deliveries. V12s for DCA plans were (18.5±15.2 cc) vs. VMAT (19.7±14.4 cc). V6s were significantly lower for DCA (69.0±52.0 cc) compared with VMAT (154.0±91.0 cc) (p <<0.05). CIs for VMAT targets were (1.38±0.50) vs. DCA (1.61±0.41). 36 of 37 DCA planned targets passed gamma tests, while 29 of 37 VMAT planned targets passed. Conclusion: Single isocenter DCA plans were easily achieved. The evaluation suggests that DCA may represent a favorable technique compared with VMAT for multiple target SRS by reducing dose to normal tissue and more accurately depicting deliverable dose.

60 APPLIED LIFE SCIENCES↗

Quantitative Assessment of Detection Frequency for the INL Ambient Air Monitoring Network

A quantitative assessment of the Idaho National Laboratory (INL) air monitoring network was performed using frequency of detection as the performance metric. The INL air monitoring network consists of 37 low-volume air samplers in 31 different locations. Twenty of the samplers are located on INL (onsite) and 17 are located off INL (offsite). Detection frequencies were calculated using both BEA and ESER laboratory minimum detectable activity (MDA) levels. The CALPUFF Lagrangian puff dispersion model, coupled with 1 year of meteorological data, was used to calculate time-integrated concentrations at sampler locations for a 1-hour release of unit activity (1 Ci) for every hour of the year. The unit-activity time-integrated concentration (TICu) values were calculated at all samplers for releases from eight INL facilities. The TICu values were then scaled and integrated for a given release quantity and release duration. All facilities modeled a ground-level release emanating either from the center of the facility or at a point where significant emissions are possible. In addition to ground-level releases, three existing stacks at the Advanced Test Reactor Complex, Idaho Nuclear Technology and Engineering Center, and Material and Fuels Complex were also modeled. Meteorological data from the 35 stations comprising the INL Mesonet network, data from the Idaho Falls Regional airport, upper air data from the Boise airport, and three-dimensional gridded data from the weather research forecasting model were used for modeling. Three representative radionuclides identified as key radionuclides in INL’s annual National Emission Standards for Hazardous Air Pollutants evaluations were considered for the frequency of detection analysis: Cs-137 (beta-gamma emitter), Pu-239 (alpha emitter), and Sr-90 (beta emitter). Source-specific release quantities were calculated for each radionuclide, such that the maximum inhalation dose at any publicly accessible sampler or the National Emission Standards for Hazardous Air Pollutants maximum exposed individual location (i.e., Frenchman’s Cabin) was no more than 0.1 mrem yr–1 (i.e., 1% of the 10 mrem yr–1 standard). Detection frequencies were calculated separately for the onsite and offsite monitoring network. As expected, detection frequencies were generally less for the offsite sampling network compared to the onsite network. Overall, the monitoring network is very effective at detecting the potential releases of Cs-137 or Sr-90 from all sources/facilities using either the ESER or BEA MDAs. The network was less effective at detecting releases of Pu-239. Maximum detection frequencies for Pu-239 using ESER MDAs ranged from 27.4 to 100% for onsite samplers and 3 to 80% for offsite samplers. Using BEA MDAs, the maximum detection frequencies for Pu-239 ranged from 2.1 to 100% for onsite samplers and 0 to 5.9% for offsite samplers. The only release that was not detected by any of the samplers under any conditions was a release of Pu-239 from the Idaho Nuclear Technology and Engineering Center main stack (CPP-708). The methodology described in this report could be used to improve sampler placement and detection frequency, provided clear performance objectives are defined.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Dynamic Assimilation Technique measures photosynthetic CO2 response curves with similar fidelity as steady-state approaches in half the time

The net CO2 assimilation (A) response to intercellular CO2 concentration (Ci) is a fundamental measurement in photosynthesis and plant physiology research. The conventional A/Ci protocols rely on steady-state measurements and take 15-40 minute per measurement, limiting data resolution or biological replication. Additionally, there are several CO2 protocols employed across the literature, without clear consensus as to the optimal protocol or systematic biases in their estimations. We compared the non-steady state Dynamic Assimilation Technique (DAT) protocol and the three most used CO2 protocols in steady-state measurements, and tested whether different CO2 protocols lead to systematic differences in estimations of the biochemical limitations to photosynthesis.

A/Ci response↗