Search NASA⌕ Search

SEARCH · Search NASA

Results for “CLINICAL MEDICINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Potentiating Antitumor Efficacy Through Radiation and Sustained Intratumoral Delivery of Anti-CD40 and Anti-PDL1

Mounting evidence demonstrates that combining radiation therapy (RT) with immunotherapy can reduce tumor burden in a subset of patients. However, conventional systemic delivery of immunotherapeutics is often associated with significant adverse effects, which force treatment cessation. The aim of this study was to investigate a minimally invasive therapeutics delivery approach to improve clinical response while attenuating toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Radiation Therapy for Pediatric Craniopharyngioma

Radiation therapy (RT) is used for pediatric craniopharyngioma in the definitive, adjuvant, or salvage settings. Proton RT may be useful owing to tumor proximity to eloquent anatomy. We report clinical outcomes for a large cohort treated with proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Controlled breaks as a fatigue countermeasure on the flight deck

BACKGROUND: A major challenge for flight crews is the need to maintain vigilance during long, highly automated nighttime flights. No system currently exists to assist in managing alertness, and countermeasure options are limited. Surveys reveal many pilots use breaks as an in-flight countermeasure, but there have been no controlled studies of their effectiveness. HYPOTHESIS: We hypothesized that brief, regular breaks could improve alertness and performance during an overnight flight. METHOD: A 6-h, uneventful, nighttime flight in a Boeing 747-400 flight simulator was flown by fourteen two-man crews. The 14 subjects in the treatment group received 5 short breaks spaced hourly during cruise; the 14 subjects in the control group received 1 break in the middle of cruise. Continuous EEG/EOG, subjective sleepiness, and psychomotor vigilance performance data were collected. RESULTS: During the latter part of the night, the treatment group showed significant reductions for 15 min post-break in slow eye movements, theta-band activity, and unintended sleep episodes compared with the control group. The treatment group reported significantly greater subjective alertness for up to 25 min post-break, with strongest effects near the time of the circadian trough. There was no evidence of objective vigilance performance improvement at 15-25 min post-break, with expected performance deterioration occurring due to elevated sleep drive and circadian time. CONCLUSIONS: The physiological and subjective data indicate the breaks reduced nighttime sleepiness for at least 15 min post-break and may have masked sleepiness for up to 25 min, suggesting the potential usefulness of short-duration breaks as an in-flight fatigue countermeasure.

Non-NASA Center↗

An overview of the space medicine program and development of the Health Maintenance Facility for Space Station

Because the prolonged stay on board the Space Station will increase the risk of possible inflight medical problems from that on Skylab missions, the Health Maintenance Facility (HMF) planned for the Space Station is much more sophisticated than the small clinics of the Skylab missions. The development of the HMF is directed by the consideration of three primary factors: prevention, diagnosis, and treatment of injuries and illnesses that may occur in flight. The major components of the HMF include the clinical laboratory, pharmacy, imaging system, critical-care system, patient-restraint system, data-management system, exercise system, surgical system, electrophysiologic-monitoring system, introvenous-fluid system, dental system, and hyperbaric-treatment-support system.

Pool, Sam Lee↗

Consistent performance of large language models in rare disease diagnosis across ten languages and 4917 cases

Background Large language models (LLMs) are increasingly used medicine for diverse applications including differential diagnostic support. The training data used to create LLMs such as the Generative Pretrained Transformer (GPT) predominantly consist of English-language texts, but LLMs could be used across the globe to support diagnostics if language barriers could be overcome. Initial pilot studies on the utility of LLMs for differential diagnosis in languages other than English have shown promise, but a large-scale assessment on the relative performance of these models in a variety of European and non-European languages on a comprehensive corpus of challenging rare-disease cases is lacking. Methods We created 4917 clinical vignettes using structured data captured with Human Phenotype Ontology (HPO) terms with the Global Alliance for Genomics and Health (GA4GH) Phenopacket Schema. These clinical vignettes span a total of 360 distinct genetic diseases with 2525 associated phenotypic features. We used translations of the Human Phenotype Ontology together with language-specific templates to generate prompts in English, Chinese, Czech, Dutch, French, German, Italian, Japanese, Spanish, and Turkish. We applied GPT-4o, version gpt-4o-2024-08-06, and the medically fine-tuned Meditron3-70B to the task of delivering a ranked differential diagnosis using a zero-shot prompt. An ontology-based approach with the Mondo disease ontology was used to map synonyms and to map disease subtypes to clinical diagnoses in order to automate evaluation of LLM responses. Findings For English, GPT-4o placed the correct diagnosis at the first rank 19.9% and within the top-3 ranks 27.0% of the time. In comparison, for the nine non-English languages tested here the correct diagnosis was placed at rank 1 between 16.9% and 20.6%, within top-3 between 25.4% and 28.6% of cases. The Meditron3 model placed the correct diagnosis within the first 3 ranks for 20.9% of cases in English and between 19.9% and 24.0% for the other nine languages. Interpretation The differential diagnostic performance of LLMs across a comprehensive corpus of rare-disease cases was largely consistent across the ten languages tested. This suggests that the utility of LLMs in clinical settings may extend to non-English clinical settings.

Artificial intelligence↗

The Visible Human Project of the National Library of Medicine: Remote access and distribution of a multi-gigabyte data set

As part of the 1986 Long-Range Plan for the National Library of Medicine (NLM), the Planning Panel on Medical Education wrote that NLM should '...thoroughly and systematically investigate the technical requirements for and feasibility of instituting a biomedical images library.' The panel noted the increasing use of images in clinical practice and biomedical research. An image library would complement NLM's existing bibliographic and factual database services and would ideally be available through the same computer networks as are these current NLM services. Early in 1989, NLM's Board of Regents convened an ad hoc planning panel to explore possible roles for the NLM in the area of electronic image libraries. In its report to the Board of Regents, the NLM Planning Panel on Electronic Image Libraries recommended that 'NLM should undertake a first project building a digital image library of volumetric data representing a complete, normal adult male and female. This Visible Human Project will include digitized photographic images for cryosectioning, digital images derived from computerized tomography, and digital magnetic resonance images of cadavers.' The technologies needed to support digital high resolution image libraries, including rapid development; and that NLM encourage investigator-initiated research into methods for representing and linking spatial and textual information, structural informatics. The first part of the Visible Human Project is the acquisition of cross-sectional CT and MRI digital images and cross-sectional cryosectional photographic images of a representative male and female cadaver at an average of one millimeter intervals. The corresponding cross-sections in each of the three modalities are to be registerable with one another.

Ackerman, Michael J.↗

Interdisciplinary Clinical Target Volume Generation for Cardiac Radioablation: Multicenter Benchmarking for the RAdiosurgery for VENtricular TAchycardia (RAVENTA) Trial

Cardiac radioablation is a novel treatment option for therapy-refractory ventricular tachycardia (VT) ineligible for catheter ablation. Three-dimensional clinical target volume (CTV) definition is a key step, and this complex interdisciplinary procedure includes VT-substrate identification based on electroanatomical mapping (EAM) and its transfer to the planning computed tomography (PCT). Benchmarking of this process is necessary for multicenter clinical studies such as the RAVENTA trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees

Definitive, nonsurgical management of gynecologic malignancies involves external beam radiation therapy (EBRT) and/or brachytherapy (BT). Summation of the cumulative dose is critical to assess the total biologic effective dose to targets and organs at risk. Cumulative dose calculation from EBRT and BT can be performed with or without image registration (IR) and biologic dose summation. Among these dose summation strategies, linear addition of dose-volume histogram (DVH) parameters without IR is the global standard for composite dose reporting. This approach stems from an era without image guidance and simple external beam and brachytherapy treatment approaches. With technological advances, EBRT and high-dose-rate BT have evolved to allow for volume-based treatment planning and delivery. Modern conformal therapeutic radiation involves volumetric or intensity modulated EBRT, capable of simultaneously treating multiple targets at different specified dose levels. Therefore, given the complexity of modern radiation treatment, the linear addition of DVH parameters from EBRT and high-dose-rate BT is challenging to represent the combined dose distribution. Deformable image registration (DIR) between EBRT and image guided brachytherapy (IGBT) data sets may provide a more nuanced calculation of multimodal dose accumulation. However, DIR is still nascent in this regard, and needs further development for accuracy and efficiency for clinical use. Biologic dose summation can combine physical dose maps from EBRT and each IGBT fraction, thereby generating a composite DVH from the biologic effective dose. However, accurate radiobiologic parameters are tissue-dependent and not well characterized. A combination of voxel-based DIR and biologic weighted dose maps may be the best approximation of dose accumulation but remains invalidated. The purpose of this report is to review dose summation strategies for EBRT and BT, including conventional equivalent dose in 2-Gy fractions dose summation without image registration, physical dose summation using 3-dimensional rigid IR and DIR, and biologic dose summation. We also provide general clinical workflows for IGBT with a focus on cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid Access Palliative Radiation Therapy Clinics: The Evidence Is There, but Where Are the Clinics? An Australian and New Zealand Perspective

First developed in Canada in the 1990s, Rapid Access Palliative Radiation Therapy (RAPRT) clinics have subsequently spread internationally to expedite treatment for near end-of-life patients, sparing them the need for multiple visits to the department. A “classical” RAPRT clinic is herein defined as “a dedicated clinic specifically established to enable (ideally) same day consultation, planning for, and delivery of palliative radiation treatment.” The aim of this work was to determine the current status of these clinics in Australia and New Zealand (ANZ).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FLASH radiotherapy: ultra-high dose rates to spare healthy tissue

A recent addition to the treatment options in external beam therapy, so-called FLASH radiotherapy, shows remarkable healthy-tissue-sparing properties in a number of pre-clinical studies without impacting the overall treatment efficacy. Its potential in clinical applications is attracting a great deal of interest in the medical community. The use of ultra-high dose rates at extremely short irradiation times has been shown to significantly enhance the differential effects between normal and tumor tissue. This makes it possible to increase treatment doses without further harming the surrounding healthy tissue. While most studies to date have focused on the use of electron beams, X-ray and proton FLASH radiotherapy have also shown beneficial effects, although for these latter two the results still need to be independently confirmed. Additionally, the mechanisms underlying the biological effects remain to be elucidated. Very recently, the FLASH effect has been demonstrated in the first human patient, with promising results, supporting further clinical studies. In this work, we present an overview of the investigations into FLASH radiotherapy to date.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Mini Beam Ready for Human Trials? Results of Randomized Study of Treating De-Novo Brain Tumors in Canines Using Linear Accelerator Generated Mini Beams

The main challenge in treating malignant brain neoplasms lies in eradicating the tumor while minimizing treatmentrelated damage. Conventional radiation treatments are associated with considerable side effects. Synchrotron generated micro-beam radiation (SMBRT) has shown to preserve brain architecture while killing tumor cells, however physical characteristics and limited facility access restrict its use. We have created a new clinical device which produces mini beams on a linear accelerator, to provide a new type of treatment called mini-beam radiation therapy (MBRT). The objective of this study is to compare the treatment outcomes of linear accelerator based MBRT versus standard radiation treatment (SRT), to evaluate the tumor response and the treatment-related changes in the normal brain with respect to each treatment type. Pet dogs with de-novo brain tumors were accrued for treatment. Dogs were randomized between standard fractionated stereotactic (9 Gy in 3 fractions) radiation treatment vs. a single fraction of MBRT (26 Gy mean dose). Dogs were monitored after treatment for clinical assessment and imaging. When the dogs were euthanized, a veterinary pathologist assessed the radiation changes and tumor response. We accrued 16 dogs, 8 dogs in each treatment arm. In the MBRT arm, 71% dogs achieved complete pathological remission. The radiation-related changes were all confined to the target region. Structural damage was not observed in the beam path outside of the target region. In contrast, none of the dogs in control group achieved remission and the treatment related damage was more extensive. Therapeutic superiority was observed with MBRT, including both tumor control and the normal structural preservation. The MBRT findings are suggestive of an immune related mechanism which is absent in standard treatment. These findings together with the widespread availability of clinical linear accelerators make MBRT a promising research topic to explore further treatment and clinical trial opportunities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Goal-Directed Ultrasound for the Diagnosis of Long-Bone Fractures by Crew Medical Officer Analogs

Current construction activities on-board the International space Station (ISS) may increase fracture incidence in space, and ultrasound (US) is the only tm-board diagnostic imaging capability. The clinical utility of US in identifying long-bone fractures is un1aowe, particularly using non-radiologist operators. We sought to determine the accuracy of US in identifying fractures of the humerus and femur, as performed by emergency medicine physicians and surgeons with minimal experience in ultrasound image acquisition and interpretation, after a standardized taming session.

Marshburn, Thomas H.↗

Construction of extracellular matrix-based 3D hydrogel and its effects on cardiomyocytes

Highlights: • SOD and Triton X-100 could efficiently decellularize cells to get cardiac ECM. • Main proteins of cECM were fibronectin, collagen, elastin, fibrillin, laminin, etc. • 75% cECM-containing 3D hydrogel promoted cell proliferation and anti-apoptosis. • cECM3DH facilitated the differentiation of ESCs into CMs. • APcECM3DH was more conducive to NCM and ESC-derived CM maturation. Some discoveries resulted from 2-dimensional (2D) cultured cardiac cells have been disqualified in animal testing and later clinical trials. Extracellular matrix (ECM) plays a vital role in cardiac homeostasis, cardiac ECM (cECM)-based 3D cell cultures can mimics the physiological and pathological conditions in vivo closely, it is hopeful of addressing this challenge. Construction of cECM-based 3-dimensional (3D) hydrogel (cECM3DH) and its effects on cell behaviors were studied here. The results indicated that cellular compartments could be efficiently removed from heart tissue via sodium dodecyl sulfonate (SDS)- and Triton X-100-mediated decellularization, remaining the natural fibrous network structure and major proteins. 3D hydrogel consisted of 1 × 10{sup 7} cells/mL cells and 75% cECM could promote the proliferation and anti-apoptosis ability of human embryonic kidney (HEK)-293T cells. 0.25% trypsin or 0.20% collagenase was suitable to retrieve these cells from 3D hydrogel for further researches. Compared with 2D culture system, cECM3DH could significantly increase the proportion of GATA 4{sup +} cardiomyocytes (CMs) derived from heart tissue of neonatal mouse or induced differentiation of embryonic stem cells (ESCs) (P < 0.05) The expression levels of mature genes including cTnT, JCN, CaV1.2, MYL2, CASQ2, NCX1, and Cx43 of these CMs in adult pig cECM-based 3D hydrogel (APcECM3DH) were significantly higher than that in 2D culture system and in newborn piglet cECM-based 3D hydrogel (NPcECM3DH), respectively (P < 0.05). Therefore, cECM3DH supports the generation of primary CMs and ESC-derived CMs, APcECM3DH was more conducive to promoting CM maturation, which contributes to building 3D model for pathogenesis exploration, drug screening, and regenerative medicine of heart diseases.

60 APPLIED LIFE SCIENCES↗

Medicine in long duration space exploration: the role of virtual reality and broad bandwidth telecommunications networks

Safety of astronauts during long-term space exploration is a priority for NASA. This paper describes efforts to produce Earth-based models for providing expert medical advice when unforeseen medical emergencies occur on spacecraft. These models are Virtual Collaborative Clinics that reach into remote sites using telecommunications and emerging stereo-imaging and sensor technologies. c 2001. Elsevier Science Ltd. All rights reserved.

Non-NASA Center↗