Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONCENTRATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Relationships between near-surface plankton concentrations, hydrography, and satellite-measured sea surface temperature

Sea surface temperatures (SSTs) mapped by IR satellite images and in situ hydrographic measurements off the west coast of British Columbia for early-winter and midsummer periods were correlated with in situ measurements of surface chlorophyll and zooplankton concentration. Correlations between winter log(e) transformed zooplankton concentrations and SSTs demonstrated that IR satellite imagery could explain 49 percent of the sampled zooplankton concentration variance. A least-squares-fit nonlinear equation showed that satellite-measured SST patterns explained 72 percent of the log(e) transformed chlorophyll variance. However, summer zooplankton concentrations were not consistently related to satellite temperature patterns.

Thomas, A. C.↗

KOH concentration effect on cycle life of nickel-hydrogen cells. III - Cycle life test

A cycle life test of Ni/H2 cells containing electrolytes of various KOH concentrations and a sintered type nickel electrode was carried out at 23 C using a 45 min accelerated low earth orbit (LEO) cycle regime at 80 percent depth of discharge. One of three cells containing 26 percent KOH has achieved over 28,000 cycles, and the other two 19,000 cycles, without a sign of failure. Two other cells containing 31 percent KOH electrolyte, which is the concentration presently used in aerospace cells, failed after 2,979 and 3,620 cycles. This result indicates that the cycle life of the present type of Ni/H2 cells may be extended by a factor of 5 to 10 simply by lowering the KOH concentration. Long cycle life of a Ni/H2 battery at high depth-of-discharge operation is desired, particularly for an LEO spacecraft application. Typically, battery life of about 30,000 cycles is required for a five year mission in an LEO. Such a cycle life with presently available cells can be assured only at a very low depth-of-discharge operation. Results of testing already show that the cycle life of an Ni/H2 cell is tremendously improved by simply using an electrolyte of low KOH concentration.

Lim, H. S.↗

Convective flows in enclosures with vertical temperature or concentration gradients

The transport process in the fluid phase during the growth of a crystal has a profound influence on the structure and quality of the solid phase. In vertical growth techniques the fluid phase is often subjected to vertical temperature and concentration gradients. The main objective is to obtain more experimental data on convective flows in enclosures with vertical temperature or concentration gradients. Among actual crystal systems the parameters vary widely. The parametric ranges studied for mass transfer are mainly dictated by the electrochemical system employed to impose concentration gradients. Temperature or concentration difference are maintained between two horizontal end walls. The other walls are kept insulated. Experimental measurements and observations were made of the heat transfer or mass transfer, flow patterns, and the mean and fluctuating temperature distribution. The method used to visualize the flow pattern in the thermal cases is an electrochemical pH-indicator method. Laser shadowgraphs are employed to visualize flow patterns in the solutal cases.

Wang, L. W.↗

Predicting minimum Al concentrations for protective scale fromation on Ni-base alloys. I - Isothermal oxidation. II - Cyclic oxidation

Criteria proposed to predict the minimum bulk Al concentration for the formation of protective Al2O3 scales on Ni-based alloys during isothermal oxidation (two criteria proposed by Wagner, 1952 and 1959) and cyclic oxidation (the criteria proposed by Wahl, 1983, and Whittle, 1972/Wahl, 1983) were applied to Ni-Al and Ni-Cr-Al(Zr) alloys, respectively. It is shown that the first Wagner (1952) criterion underpredicted, by a factor of 3, the experimentally observed minimum Al concentration for the formation of an external Al2O3 scale on Ni-Al alloys at 1200 C; the second Wagner criterion predicted a transition from internal oxidation to continuous Al2O3 formation in good agreement with experimentally observed concentrations. It was also found that the two criteria for an Al2O3 scale formation during cyclic oxidation of Ni-Cr-Al(Zr) alloys were inadequate to predict the minimum Al concentration necessary for repeated formation of an Al2O3 scale, regardless of the adherence of the scale.

Nesbitt, James A.↗

KOH concentration effect on the cycle life of nickel-hydrogen cells. Part 4: Results of failure analyses

KOH concentration effects on cycle life of a Ni/H2 cell have been studied by carrying out a cycle life test of ten Ni/H2 boiler plate cells which contain electrolytes of various KOH concentrations. Failure analyses of these cells were carried out after completion of the life test which accumulated up to 40,000 cycles at an 80 percent depth of discharge over a period of 3.7 years. These failure analyses included studies on changes of electrical characteristics of test cells and component analyses after disassembly of the cell. The component analyses included visual inspections, dimensional changes, capacity measurements of nickel electrodes, scanning electron microscopy, BET surface area measurements, and chemical analyses. Results have indicated that failure mode and change in the nickel electrode varied as the concentration was varied, especially, when the concentration was changed from 31 percent or higher to 26 percent or lower.

Lim, H. S.↗

28 percent efficient GaAs concentrator solar cells

AlGaAs/GaAs heteroface solar concentrator cells which exhibit efficiencies in excess of 27 percent at high solar concentrations (over 400 suns, AM1.5D, 100 mW/sq cm) have been fabricated with both n/p and p/n configurations. The best n/p cell achieved an efficiency of 28.1 percent around 400 suns, and the best p/n cell achieved an efficiency of 27.5 percent around 1000 suns. The high performance of these GaAs concentrator cells compared to earlier high-efficiency cells was due to improved control of the metal-organic chemical vapor deposition growth conditions and improved cell fabrication procedures (gridline definition and edge passivation). The design parameters of the solar cell structures and optimized grid pattern were determined with a realistic computer modeling program. An evaluation of the device characteristics and a discussion of future GaAs concentrator cell development are presented.

Macmillan, H. F.↗

Concentrations and size distributions of Antarctic stratospheric aerosols

Particle Measuring Systems laser particle spectrometer (ASAS-X and FSSP) probes were used to measure aerosol particle concentrations and size distributions during 11 ER-2 flights between Punta Arenas (53 deg S) and Antarctica (up to 72 deg S) from August 17 to September 22, 1987. The time resolution was 10 s, corresponding to a spatial resolution of 2 km. The data were divided into two size classes (0.05-0.25 and 0.53-5.5 micron radius) to separate the small particle from the coarse particle populations. Results show that the small-particle concentrations are typical for a background aerosol during volcanic quiescence. This concentration is generally constant along a flight track; in only one instance a depletion of small particles during a polar stratospheric cloud (PSC) encounter was measured, suggesting a nucleation of type I PSC particles on background aerosols. Temporary increases of the coarse particle concentrations indicated the presence of tenuous polar stratospheric clouds that were encountered most frequently at the southernmost portion of a flight track and when the aircraft descended to lower altitudes. During 'particle events', particle modes were found at 0.6-micron radius, corresponding to type I PSCs, and occasionally, at 2.0-micron radius corresponding to type II PSCs.

Ferry, G. V.↗

Cobalt and nickel concentrations in the 'komatiite component' of Apollo 16 polymict samples

Some estimates for the concentrations of Co and Ni in the primitive mafic component of Apollo 16 breccias and soils are large, comparable to concentrations in terrestrial komatiites. These estimates may be erroneously high because the contribution from meteoritic contamination of the samples has been underestimated. However, even if the correction for meteoritic Co and Ni is valid and the calculated residual Ni is not of meteoritic origin, the Ni is presently carried by Fe-Ni metal while the Fe and Mg are carried by mafic silicates. If any large-scale separation of metal and silicate phases has occurred, the concentration ratio of Ni to Fe + Mg in the mafic silicates of the ancient crust in the vicinity of the Apollo 16 site has not been preserved by Apollo 16 rocks. Apollo 16 polymict breccias and soils contain much higher concentrations of siderophile elements and Fe-Ni metal than other nonmare samples from the Moon. Thus, it is likely that the Ni/(Mg + Fe) ratio estimated for the komatiite component from Apollo 16 samples is high compared to the actual ratio for the lunar crust.

Korotev, Randy L.↗

KOH concentration effect on the cycle life of nickel-hydrogen cells. IV - Results of failure analysis

Potassium hydroxide concentration effects on the cycle life of a Ni/H2 cell have been studied by carrying out a cycle life test on ten Ni/H2 boiler plate cells which contain electrolytes of various KOH concentrations. Failure analyses of these cells were carried out after completion of the life test, which accumulated up to 40,000 cycles at an 80-percent depth of discharge over a period of 3.7 years. These failure analyses included studies on changes of electrical characteristics of test cells, and component analyses after disassembly of the cell. The component analyses included visual inspections, dimensional changes, capacity measurements of nickel electrodes, scanning electron microscopy, surface area measurements, and chemical analyses. Results have indicated that failure mode and change in the nickel electrode varied as the concentration was varied, especially when the concentration was changed from 31 percent or higher to 26 percent or lower.

Lim, H. S.↗

The mini-dome lens space concentrator array - Recent component test results and current array development status

The development of a high-performance, lightweight space photovoltaic concentrator array is described. The array is the first space photovoltaic concentrator system to use a refractive optical concentrator in the form of a dome-shaped, point-focus, Fresnel lens. In addition, it is the first such concentrator system to utilize prismatic cell covers to eliminate gridline obscuration losses. By combining these array features with state-of-the-art gallium arsenide cell technology, array areal power values (in watts per square meter) well in excess of present space power system levels are anticipated. In addition, the array has the potential for extremely high specific power values (in watts per kilogram).

O'Neill, M. J.↗

An advanced concentrator for solar dynamic power systems in space

Solar concentrators based on rigidized stretched-membrane technology, which have been shown to be a possible alternative to rigid segmented concentrators for solar dynamic power applications in space, are discussed. Membrane concentrators offer an advantage in weight, efficiency of structure use, deployability, and cost. Predeployment packaging and subsequent deployment of a prototype membrane concentrator has been demonstrated. Attractive membrane fabrication techniques have been identified and demonstrated. The concept is described, and materials selection and membrane fabrication are examined.

Beninga, Kelly↗

Seasonal and interannual variability of pigment concentrations across a California Current frontal zone

The seasonal and interannual variability of the latitudinal position of the California Current frontal zone was investigated by examining satellite images of phytoplankton pigment from the coastal-zone color scanner for the periods 1979-1983 and 1986. The pigment concentrations associated with the zonal front were also determined. A general seasonal cycle of pigment concentrations is was established. It was found that variations in the frontal structure are controlled primarily by changes in pigment concentration north of the front. Seasonal variations were found to be minimal south of the front, where pigment concentrations remain low throughout the spring, summer, and fall.

Thomas, A. C.↗

High altitude AM0 testing of PV concentrator lens elements

Recently, the NASA Lewis Research Center modified its Lear High Altitude Test Facility to fly two prototype ENTECH minidome Fresnel lens photovoltaic concentrator elements. The tests were highly successful, and the results verified the ability of the Lear High Altitude Facility to measure the optical performance of individual concentrator lens elements and concentrator/cell combinations at near AM0 insolation conditions. The two concentrator lenses flown achieved optical efficiencies, based on a gallium arsenide concentrator cell response, of 89.8 percent and 90.0 percent. The flights demonstrated the ability of the aircraft to maintain the pointing accuracy required to obtain useful data. With proper alignment of the collimating tube and the pilot's sunsight, this facility could easily maintain a pointing accuracy of + or - 0.5 deg for a sufficiently long time to obtain accurate, reproducible results.

Piszczor, M. F.↗

Stress concentrations for straight-shank and countersunk holes in plates subjected to tension, bending, and pin loading

A three dimensional stress concentration analysis was conducted on straight shank and countersunk (rivet) holes in a large plate subjected to various loading conditions. Three dimensional finite element analysis were performed with 20 node isoparametric elements. The plate material was assumed to be linear elastic and isotropic, with a Poisson ratio of 0.3. Stress concentration along the bore of the hole were computed for several ratios of hole radius to plate thickness (0.1 to 2.5) and ratios of countersink depth to plate thickness (0.25 to 1). The countersink angles were varied from 80 to 100 degrees in some typical cases, but the angle was held constant at 100 degrees for most cases. For straight shank holes, three types of loading were considered: remote tension, remote bending, and wedge loading in the hole. Results for remote tension and wedge loading were used to estimate stress concentration for simulated rivet in pin loading. For countersunk holes only remote tension and bending were considered. Based on the finite element results, stress concentration equations were developed. Whenever possible, the present results were compared with other numerical solutions and experimental results from the literature.

Shivakumar, K. N.↗

Criticality of Be-7 concentration in LDEF

Heretofore, a number of papers reported the detection of high Be-7 concentration in the LDEF. It sounded alarming for space flight in the LDEF orbit, since Be-7 has a half life of 54 days and emits gamma rays of 0.48 MeV which is ionizing radiation. Two concerns are raised: the high concentration of harmful rays to spacecraft crews; and the concentration damage to spacecraft electronic components. A need was established to estimate the dosage of this concentration and compare the value of the allowed limits. As a result, the dosage was calculated of 0.03 rad. When this is compared with the human limit of 25 rads and the susceptibility requirement of 800 rads, the Be-7 amount should not be considered critical. The calculation of Be-7 dosage is detailed.

Young, Poh Shien↗

NASA, Navy, and AES/York sea ice concentration comparison of SSM/I algorithms with SAR derived values

Previous research studies have focused on producing algorithms for extracting geophysical information from passive microwave data regarding ice floe size, sea ice concentration, open water lead locations, and sea ice extent. These studies have resulted in four separate algorithms for extracting these geophysical parameters. Sea ice concentration estimates generated from each of these algorithms (i.e., NASA/Team, NASA/Comiso, AES/York, and Navy) are compared to ice concentration estimates produced from coincident high-resolution synthetic aperture radar (SAR) data. The SAR concentration estimates are produced from data collected in both the Beaufort Sea and the Greenland Sea in March 1988 and March 1989, respectively. The SAR data are coincident to the passive microwave data generated by the Special Sensor Microwave/Imager (SSM/I).

Jentz, R. R.↗

Series integration of the diaphragm cell transport equation when the diffusion coefficient is a function of concentration

An integral of the form, t = B0 + BL ln(Delta-c) + B1(Delta-c) + B2(Delta-c)-squared + ..., where t is the time and Delta-c is the concentration difference across the frit, is derived in the case of the diaphragm cell transport equation where the interdiffusion coefficient is a function of concentration. The coefficient, B0, is a constant of the integration, while the coefficients, BL, B1, B2,..., depend in general upon the constant, the compartment volumes, and the interdiffusion coefficient and various of its concentration derivatives evaluated at the mean concentration for the cell. Explicit formulas for BL, B1, B2,... are given.

Cain, Judith B.↗

Microsheet Glass In Solar Concentrators

Microsheet glass used as highly protective covering material for developmental concentrating reflectors for solar power systems. Together with other materials, possible to fabricate lightweight, highly reflective, accurate, and long-lived concentrators. Desirable properties include durability and smoothness. Glass not affected by ultraviolet radiation, and not degraded by atomic oxygen, found in low orbits around Earth. Though concentrators intended for use in outer space, noteworthy that terrestrial concentrator fabricated with glass sheet 0.7 mm thick.

Richter, Scott W.↗