Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Battling Brittle Bones

The accuDEXA(R) Bone Mineral Density Assessment System, manufactured by Schick Technologies, Inc., utilizes "camera on a chip" sensor technology invented and developed by NASA's Jet Propulsion Laboratory. Schick's accuDEXA system offers several advantages over traditional osteoporosis tests, which assess bone density loss in the hip and spine, and require specialized personnel to conduct. With accuDEXA, physicians can test the entire body's bone density at a peripheral site, such as the finger, without applying gels or having patients remove garments. Results are achieved in 30 seconds and printed out in less than a minute, compared to the estimated exam time of 15 minutes for hip and spine density analyses. Schick has also applied the CMOS APS technology to a new software product that performs dental radiography using up to 90 percent less radiation exposure than conventional X-rays. Called Computed Dental Radiography(R), the new digital imaging product utilizes an electronic sensor in place of X-ray film to generate sharp and clear images that appear on a computer screen within 3 seconds, and can be enlarged and enhanced to identify problems.

Source record↗

Industrial Inspection System

Lixi, Inc. has built a thriving business on NASA-developed x-ray technology. The Low Intensity X-ray Imaging scope (LIXI) was designed to use less than one percent of radiation required by conventional x-ray devices. It is portable and can be used for a variety of industrial inspection systems as well as medical devices. A food processing plant uses the new LIXI Conveyor system to identify small bone fragments in chicken. The chicken packages on a conveyor belt enter an x-ray chamber and the image is displayed on a monitor. Defects measuring less than a millimeter can be detected. An important advantage of the system is its ability to inspect 100 percent of the product right on the production line.

Source record↗

Impact of Irradiation on Microstructure and Mechanical Properties of Materials Produced by Advanced Manufacturing

Advanced non-light water reactor designs, known as Generation IV (Gen IV) reactors, typically operate at higher temperatures and under more extreme radiation conditions than conventional light water reactors. A critical aspect of the successful deployment and advancement of Gen IV reactor designs is the selection of appropriate structural materials for specific applications, which necessitates the timely development of new materials and manufacturing processes. Advanced manufacturing (AM) offers numerous opportunities for innovative designs, enabling the production of high-performance components with potentially shorter development cycles compared to traditional manufacturing methods. However, a significant challenge in deploying AM technologies in the nuclear energy sector is the current lack of data on the irradiation performance of AM-produced components. This presentation will discuss neutron and ion irradiation results of AM materials, including stainless steel 316L, Grade 91, SA508, Inconel 718, and Inconel 625 materials. The materials were manufactured by AM, such as Powder Metallurgy Hot Isostatic Pressing (PM HIP), Laser Powder Bed Fusion (LPBF) and Directed Energy Deposition (DED). The effects of neutron irradiation on microstructure (e.g., dislocations, loops, and nanoclusters), tensile properties (e.g., strength and ductility), and ion irradiation on Irradiation-Assisted Stress Corrosion Cracking (IASCC) will be explored. Results are collected from several projects supported by the Nuclear Science User Facilities (NSUF) program.

36 - MATERIALS SCIENCE↗

Radiation damage in high-resistivity silicon solar cells

High-resistivity silicon solar cells exhibit reduced radiation damage when light is incident on the gridded back surface. Under back illumination, radiation damage decreases as cell resistivity increases; under front illumination, radiation damage increases as cell resistivity increases. Thin back-illuminated cells outperform conventional 10 omega cm 50 and 200 micron cells at low 1-MeV electron fluences. However, at higher fluences, the conventional cells exhibit superior radiation resistance. This is attributed to the low BOL diffusion lengths observed in the thin, sack-illuminated cell. These results are discussed in terms of injected charge distributions, electric fields in the cell base, and the effects of a dominant boron-oxygen defect.

Weinberg, I.↗

Horizontal Radiative Fluxes in Clouds at Absorbing Wavelengths

We discuss the effect of horizontal fluxes on the accuracy of a conventional plane-parallel radiative transfer calculation for a single pixel, known as the Independent Pixel Approximation (IPA) at absorbing wavelengths. Vertically integrated horizontal fluxes can be represented as a sum of three components; each component is the IPA accuracy on a pixel-by-pixel basis for reflectance, transmittance and absorptance, respectively. We show that IPA accuracy for reflectance always improves with more absorption, while the IPA accuracy for transmittance is less sensitive to the changes in absorption: with respect to the non-absorbing case, it may first deteriorate for weak absorption and then improve again for strongly absorbing wavelengths. EPA accuracy for absorptance always deteriorates with more absorption. As a result, vertically integrated horizontal fluxes, as a sum of IPA accuracies for reflectance, transmittance and absorptance, increase with more absorption. Finally, the question of correlations between horizontal fluxes, IPA uncertainties and radiative smoothing is addressed using wavenumber spectra of radiation fields reflected from or transmitted through fractal clouds.

Marshak, A.↗

Effect of gamma-ray irradiation on the surface states of MOS tunnel junctions

Gamma-ray irradiation with doses up to 8 megarad produces no significant change on either the C(V) or the G(V) characteristics of MOS tunnel junctions with intermediate oxide thicknesses (40-60 A), whereas the expected flat-band shift toward negative electrode voltages occurs in control thick oxide capacitors. A simple tunneling model would explain the results if the radiation-generated hole traps are assumed to lie below the valence band of the silicon. The experiments also suggest that the observed radiation-generated interface states in conventional MOS devices are not due to the radiation damage of the silicon surface.

Ma, T. P.↗

A Population-Based Comparative Effectiveness Study of Radiation Therapy Techniques in Stage III Non-Small Cell Lung Cancer

Purpose: Concerns have been raised about the potential for worse treatment outcomes because of dosimetric inaccuracies related to tumor motion and increased toxicity caused by the spread of low-dose radiation to normal tissues in patients with locally advanced non-small cell lung cancer (NSCLC) treated with intensity modulated radiation therapy (IMRT). We therefore performed a population-based comparative effectiveness analysis of IMRT, conventional 3-dimensional conformal radiation therapy (3D-CRT), and 2-dimensional radiation therapy (2D-RT) in stage III NSCLC. Methods and Materials: We used the Surveillance, Epidemiology, and End Results (SEER)-Medicare database to identify a cohort of patients diagnosed with stage III NSCLC from 2002 to 2009 treated with IMRT, 3D-CRT, or 2D-RT. Using Cox regression and propensity score matching, we compared survival and toxicities of these treatments. Results: The proportion of patients treated with IMRT increased from 2% in 2002 to 25% in 2009, and the use of 2D-RT decreased from 32% to 3%. In univariate analysis, IMRT was associated with improved overall survival (OS) (hazard ratio [HR] 0.90, P=.02) and cancer-specific survival (CSS) (HR 0.89, P=.02). After controlling for confounders, IMRT was associated with similar OS (HR 0.94, P=.23) and CSS (HR 0.94, P=.28) compared with 3D-CRT. Both techniques had superior OS compared with 2D-RT. IMRT was associated with similar toxicity risks on multivariate analysis compared with 3D-CRT. Propensity score matched model results were similar to those from adjusted models. Conclusions: In this population-based analysis, IMRT for stage III NSCLC was associated with similar OS and CSS and maintained similar toxicity risks compared with 3D-CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An EOF Iteration Approach for Obtaining Homogeneous Radiative Fluxes from Satellites Observations

Conventional observations of climate parameters are sparse in space and/or in time and the representativeness of such information needs to be optimized. Observations from satellites provide improved spatial coverage than point observations however they pose new challenges for obtaining homogeneous coverage. Surface radiative fluxes, the forcing functions of the hydrologic cycle and biogeophysical processes, are now becoming available from global scale satellite observations. They are derived from independent satellite platforms and sensors that differ in temporal and spatial resolution and in the size of the footprint from which information is derived. Data gaps, degraded spatial resolution near boundaries of geostationary satellites, and different viewing geometries in areas of satellite overlap, could result in biased estimates of radiative fluxes. In this study, discussed will be issues related to the sources of inhomogeneity in surface radiative fluxes as derived from satellites; development of an approach to obtain homogeneous data sets; and application of the methodology to the widely used International Satellite Cloud Climatology Project (ISCCP) data that currently serve as a source of information for deriving estimates of surface and top of the atmosphere radiative fluxes. Introduced is an Empirical Orthogonal Function (EOF) iteration scheme for homogenizing the fluxes. The scheme is evaluated in several ways including comparison of the inferred radiative fluxes against ground observations, both before and after the EOF approach is applied. On the average, the latter reduces the rms error by about 2-3 W/m2.

Zhang, Banglin↗

Evolutionary recovery from radiation induced faults and reconfigurable devices

Radiation hardening technologies for electronics are the conventional approach for survivability in high radiation environments. This paper presents a novel approach based on evolvable hardware. The key idea is to reconfigure a programmable device, in-situ, to compensate, or bypass its degraded or damaged compoenents.

Daud, Taher↗

High Resolution X-Ray Microangiography of 4T1 Tumor in Mouse Using Synchrotron Radiation

Angiogenesis is very important in tumor growth and metastasis. But in clinic, only vessels lager than 200 {mu}m in diameter, can be observed using conventional medical imaging. Synchrotron radiation (SR) phase contrast imaging, whose spatial resolution can reach as high as 1 {mu}m, has great advantages in imaging soft tissue structures, such as blood vessels and tumor tissues. In this paper, the morphology of newly formed micro-vessels in the mouse 4T1 tumor samples was firstly studied with contrast agent. Then, the angiogenesis in nude mice tumor window model was observed without contrast agent using the SR phase contrast imaging at the beamline for X-ray imaging and biomedical applications, Shanghai Synchrotron Radiation Facility (SSRF). The images of tumors showed dense, irregular and tortuous tumor micro-vessels with the smallest size of 20-30 {mu}m in diameter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster - 11: Radiation barrier thickness calculations for the GammaPod

A consortium of radiotherapy centers in North America is in the process of evaluating a novel new {sup 60}Co teletherapy device, called the GammaPod™ (Xcision Medical Systems, Columbia Maryland), designed specifically for breast SBRT. The GammaPod consists of 36 collimated {sup 60}Co sources with a total activity of 4320 Ci. The sources are housed in a hemispherical source carrier that rotates during treatment to produce a cylindrically symmetric cone of primary beam spanning 16° – 54° degrees from the horizontal. This unique beam geometry presents challenges when designing or evaluating room shielding for the purposes of meeting regulatory requirements, and for ensuring the safety of staff and the public in surrounding areas. Conventional methods for calculating radiation barrier thicknesses have been adapted so that barrier transmission factors for the GammaPod can be determined from a few relevant distances and characteristics of the primary beam. Simple formalisms have been determined for estimating shielding requirements for primary radiation (with a rotating and non-rotating source carrier), patient-scattered radiation, and leakage radiation. When making worst case assumptions, it was found that conventional barrier thicknesses associated with linac treatment suites are sufficient for shielding all sources of radiation from the GammaPod.

60 APPLIED LIFE SCIENCES↗

Exact and fast calculation of the X-ray pair distribution function

A fast and exact algorithm to calculate the powder pair distribution function (PDF) for the case of periodic structures is presented. The new algorithm calculates the PDF by a detour via reciprocal space. The calculated normalized total powder diffraction pattern is transferred into the PDF via the sine Fourier transform. The calculation of the PDF via the powder pattern avoids the conventional simplification of X-ray and electron atomic form factors. It is thus exact for these types of radiation, as is the conventional calculation for the case of neutron diffraction. The new algorithm further improves the calculation speed. Additional advantages are the improved detection of errors in the primary data, the handling of preferred orientation, the ease of treatment of magnetic scattering and a large improvement to accommodate more complex instrumental resolution functions.

36 MATERIALS SCIENCE↗

Analysis of Thermoradiative Thermal Energy Conversion

The thermoradiative cell is a new method for converting heat energy to electrical power, first detailed by Strandberg in 2015. The cell is a p-n junction semiconductor device, similar to a photovoltaic cell but thermodynamically operating in the reverse direction, converting the thermal dark current into electrical power while radiating waste heat to space. The power and efficiency can be calculated as a function of bandgap in the Shockley-Queisser detailed-balance limit, in which the thermal emissivity of the cell is due to the recombination of electron-hole pairs, and all other recombination losses are ignored. The current produced is directly proportional to the recombination radiation. The fundamental loss mechanism for the thermoradiative cell is the energy carried by the infrared radiation into space from band-to-band recombination of carriers injected across the junction. In an ideal cell, to maximize the efficiency, the emission energy of these photons would precisely equal the bandgap. This can be achieved, for example, using dielectric filters or meta-material filters to recycle emission at other wavelengths back into the cell. The voltage is proportional to the external bias. These two constraints allow optimization of the optimum bias point for maximum power. Unlike photovoltaic cells, the maximum power operating point is not the same as the maximum efficiency point, and higher efficiency can be achieved at a higher (negative) bias in the ideal case. Incorporating non-ideal losses, however, shifts the maximum efficiency point toward lower bias. Unlike in photovoltaic cells, non-radiative recombination (e.g., Auger losses) will reduce the output current, but will not reduce the conversion efficiency, since the recombination energy is retained in the cell in the form of heat. Since a thermoradiative cell operates by radiating directly to space, the current produced by themoradiative cells will increase as Stefan-Boltzmann radiation; roughly the fourth power of the temperature. Thus, the power produced is highest at high operating temperatures, and, unlike conventional thermal conversion, increasing radiator temperature increases, the efficiency. Thus, the choice of technology will be toward semiconductors resistant to degradation at high temperature.

Thermoradiative↗

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional counters, 2) Boron-lined proportional counters, 3) Lithium-loaded glass fibers, and 4) Coated non-scintillating plastic fibers. In addition, a few other companies have detector technologies that might be competitive in the near term as an alternative technology. Reported here are the results of tests of a boron-lined, multichamber proportional counter manufactured by LND, Inc. Also reported are results obtained with an earlier design of conventional, boron-lined, proportional counters from LND. This testing measured the required performance for neutron detection efficiency and gamma-ray rejection capabilities of the detectors.

3He↗

Detection of alpha particles using DNA/Al Schottky junctions

Deoxyribonucleic acid or DNA can be utilized in an organic-metallic rectifying structure to detect radiation, especially alpha particles. This has become much more important in recent years due to crucial environmental detection needs in both peace and war. In this work, we fabricated an aluminum (Al)/DNA/Al structure and generated current–voltage characteristics upon exposure to alpha radiation. Two models were utilized to investigate these current profiles; the standard conventional thermionic emission model and Cheung and Cheung's method. Using these models, the barrier height, Richardson constant, ideality factor and series resistance of the metal-DNA-metal structure were analyzed in real time. The barrier height, Φ value calculated using the conventional method for non-radiated structure was 0.7149 eV, increasing to 0.7367 eV after 4 min of radiation. Barrier height values were observed to increase after 20, 30 and 40 min of radiation, except for 6, 8, and 10 min, which registered a decrease of about 0.67 eV. This was in comparison using Cheung and Cheung's method, which registered 0.6983 eV and 0.7528 eV for the non-radiated and 2 min of radiation, respectively. The barrier height values, meanwhile, were observed to decrease after 4 (0.61 eV) to 40 min (0.6945 eV). The study shows that conventional thermionic emission model could be practically utilized for estimating the diode parameters including the effect of series resistance. These changes in the electronic properties of the Al/DNA/Al junctions could therefore be utilized in the manufacture of sensitive alpha particle sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting Radiation-Induced Injury Using Rapid 3D Variogram Analysis of CT Images of Rat Lungs

A new heterogeneity analysis approach to discern radiation-induced lung damage was tested on CT images of irradiated rats. The method, combining octree decomposition with variogram analysis, demonstrated a significant correlation with radiation exposure levels, whereas conventional measurements and pulmonary function tests did not. The results suggest the new approach may be highly sensitive for assessing even subtle radiation-induced changes

Jacob, Rick E.↗