Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSION TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Advanced bearing materials for cryogenic aerospace engine turbopump requirements

The properties of eleven alloys were investigated to select an improved bearing material for the High Pressure Oxygen Turbo Pump which delivers liquid oxygen to the Space Shuttle Main Engine. The alloys, selected through detailed literature analysis, X 405, MRC-2001, T440V, 14-4/6V, D-5, V-M Pyromet 350, Stellite 3, FerroTic CS-40, Tribaloy 800, WD-65, and CBS-600. The alloys were tested in hardness, corrosion resistance, wear resistance, fatigue resistance, and fracture toughness tests, and their performance was compared with the baseline 440C test alloy. As a result, five alloys were eliminated, leaving the remaining six (X 405, MRC-2001, T440V, 14-4/6V, D-5, and WD-65 to be evaluated in the next phase of NASA tests which will include fracture toughness, rolling contact fatigue, wear resistance, and corrosion resistance. From these, three alloys will be selected, which will be made into ninety bearings for subsequent testing.

Friedman, G.↗

The Test and Evaluation of a Non-Chromate Finishing Agent

This research is focused on the design, development and implementation of an industry, military and commercial standard testing cell for surface coatings, which focuses on advanced non-chromate materials technology and their commercialization. Currently, within both private and commercial sectors, chromates are used in the corrosion prevention. processes. However, there is a great demand for chromate-free systems that are able to provide equal protection. At the end of this effort, it is intended that a patented alternative to chromate conversion coatings would be tested and processed for commercialization. Thus far, research studies have been concerned primarily with current corrosion knowledge and testing methods. Corrosion can be classified into five categories: The first type is uniform corrosion which is dominated by a uniform thinning due to an even and regular loss of metal. The second type is called localized corrosion in which most of the loss occurs in discrete areas. The third type, metallurgically influenced corrosion is a form of attack where metallurgy plays a significant role. The fourth type, titled mechanically assisted degradation is a form of attack where velocity, abrasion, and hydrodynamics control the corrosion process. The last type of corrosion is defined as environmentally induced cracking which occurs when cracks are produced under specific, premeditated stress. Oddly enough, with these varying classifications, there are not as many standardized corrosion testing sites. Two of the most common testing methods for corrosion are salt spray testing and filiform. Although neither has proven to be absolute, in terms of the resulting observations, our research aims to help provide data that may be used to support the standardization for corrosion testing. We would acquire and use a Singleton Cyclic Corrosion Testing Chamber. Singleton test chambers perform a wide range of commonly used catalytic corrosion tests. They are used throughout the industry, some of which are - automotive, aerospace, electronic and many more. In addition to this, Singleton test chambers are fully expandable to accommodate cyclic corrosion testing needs. Singleton chambers are also designed for complete compliance and conformity with ASTM (American Society for Testing and Materials), military and commercial standards.

Gulley, H.↗

An artifical corrosion protocol for lap-splices in aircraft skin

This paper reviews the progress to date to formulate an artificial corrosion protocol for the Tinker AFB C/KC-135 Corrosion Fatigue Round Robin Test Program. The project has provided new test methods to faithfully reproduce the corrosion damage within a lap-splice by accelerated means, the rationale for a new laboratory test environment, and a means for corrosion damage quantification. The approach is pragmatic and the resulting artificial corrosion protocol lays the foundation for future research in the assessment of aerospace alloys. The general means for quantification of corrosion damage has been presented in a form which can be directly applied to structural integrity calculations.

Shaw, Bevil J.↗

A preliminary mechanical property and stress corrosion evaluation of VIM-VAR work strengthened and direct aged Inconel 718 bar material

This report presents a preliminary mechanical property and stress corrosion evaluation of double melted (vacuum induction melted (VIM), and vacuum arc remelted (VAR)), solution treated, work strengthened and direct aged Inconel 718 alloy bar (5.50 in. (13.97 cm) diameter). Two sets of tensile specimens, one direct single aged and the other direct double aged, were tested at ambient temperature in both the longitudinal and transverse directions. Longitudinal tensile and yield strengths in excess of 200 ksi (1378.96 MPa) and 168 ksi (1158.33 MPa), respectively, were realized at ambient temperature, for the direct double aged specimen. No failures occurred in the single or double edged longitudinal and transverse tensile specimens stressed to 75 and 100 percent of their respective yield strengths and exposed to a salt fog environment for 180 days. Tensile tests performed after the stress corrosion test showed no mechanical property degradation.

Montano, J. W.↗

A mechanical property and stress corrosion evaluation of 431 stainless steel alloy

The mechanical properties of type 431 stainless steel in two conditions: annealed bar and hardened and tempered bar are presented. Test specimens, manufactured from approximately 1.0 inch (2.54 cm) diameter bar stock, were tested at temperatures of 80 F (+26.7 C), 0 F (-17.8 C), -100 F (-73 C), and -200 F (-129 C). The test data indicated excellent tensile strength, notched/unnotched tensile ratio, ductility, shear, and impact properties at all testing temperatures. Results of the alternate immersion stress corrosion tests on stressed and unstressed longitudinal tensile specimens 0.1250 inch (0.3175 cm) diameter and transverse C-ring specimens, machined from 1.0 inch (2.54 cm) diameter bar stock, indicated that the material is not susceptible to stress corrosion cracking when tested in a 3.5 percent NaCl solution for 180 days.

Montano, J. W.↗

A mechanical property and stress corrosion evaluation of VIM-ESR-VAR work strengthened and direct double aged Inconel 718 bar material

Presented are the mechanical properties and the stress corrosion resistance of triple melted vacuum induction melted (VIM), electro-slag remelted (ESR), and vacuum arc remelted (VAR), solution treated, work strengthened and direct double aged Inconel 718 alloy bars 4.00 in. (10.16) and 5.75 in. (14.60 cm) diameter. Tensile, charpy v-notched impact, and compact tension specimens were tested at ambient temperature in both the longitudinal and transverse directions. Longitudinal tensile and yield strengths in excess of 220 ksi (1516.85 MPa) and 200 ksi (1378.00 MPa) respectively, were realized at ambient temperature. Additional charpy impact and compact tension tests were performed at -100 F (-73 C). Longitudinal charpy impact strength equalled or exceeded 12.0 ft-lbs (16.3 Joules) at ambient and at -100 F(-73 C) while longitudinal compact (LC) tension fracture toughness strength remained above 79 ksi (86.80 MPa) at ambient and at -100 F(-73 C) temperatures. No failures occurred in the longitudinal or transverse tensile specimens stressed to 75 and 100 percent of their respective yield strengths and exposed to a salt fog environment for 180 days. Tensile tests performed after the stress corrosion test indicated no mechanical property degradation.

Montano, J. W.↗

Simulation of Fatigue Crack Initiation at Corrosion Pits With EDM Notches

Uniaxial fatigue tests were conducted to compare the fatigue life of laboratory produced corrosion pits, similar to those observed in the shuttle main landing gear wheel bolt-hole, and an electro-discharged-machined (EDM) flaw. EDM Jaws are used to simulate corrosion pits during shuttle wheel (dynamometer) testing. The aluminum alloy, (AA 7050) laboratory fatigue tests were conducted to simulate the local stress level contained in the wheel bolt-hole. Under this high local stress condition, the EDM notch produced a fatigue life similar to test specimens containing corrosion pits of similar size. Based on the laboratory fatigue test results, the EDM Jaw (semi-circular disc shaped) produces a local stress state similar to corrosion pits and can be used to simulate a corrosion pit during the shuttle wheel dynamometer tests.

Smith, Stephen W.↗

Terahertz NDE Application for Corrosion Detection and Evaluation under Shuttle Tiles

Pulsed Terahertz NDE is being examined as a method to inspect for possible corrosion under Space Shuttle Tiles. Other methods such as ultrasonics, infrared, eddy current and microwave technologies have demonstrable shortcomings for tile NDE. This work applies Terahertz NDE, in the frequency range between 50 GHz and 1 THz, for the inspection of manufactured corrosion samples. The samples consist of induced corrosion spots that range in diameter (2.54 to 15.2 mm) and depth (0.036 to 0.787 mm) in an aluminum substrate material covered with tiles. Results of these measurements are presented for known corrosion flaws both covered and uncovered and for blind tests with unknown corrosion flaws covered with attached tiles. The Terahertz NDE system is shown to detect all artificially manufactured corrosion regions under a Shuttle tile with a depth greater than 0.13 mm.

Anastasi, Robert F.↗

Electrochemical Apparatus Simulates Corrosion In Crevices

Method of testing metal specimens for susceptibility to galvanic corrosion in crevices involves use of relatively simple electrochemical apparatus. By following method, one quantifies rates of corrosion of dissimilar-metal couples exposed to various etchants or other corrosive solutions.

Khoshbin, S. Rachel↗

Utilizing various test methods to study the stress corrosion behavior of Al-Li-Cu alloys

Recently, much attention has been given to aluminum-lithium alloys because of rather substantial specific-strength and specific-stiffness advantages offered over commercial 2000and 7000-series aluminum alloys. An obstacle to Al-Li alloy development has been inherent limited ductility. In order to obtain a more refined microstructure, powder metallurgy (P/M) has been employed in alloy development programs. As stress corrosion (SC) of high-strength aluminum alloys has been a major problem in the aircraft industry, the possibility of an employment of Al-Li alloys has been considered, taking into account a use of Al-Li-Cu alloys. Attention is given to a research program concerned with the evaluation of the relative SC resistance of two P/M processed Al-Li-Cu alloys. The behavior of the alloys, with and without an addition of magnesium, was studied with the aid of three test methods. The susceptibility to SC was found to depend on the microstructure of the alloys.

Pizzo, P. P.↗

Effect of a chromium-containing fuel additive on hot corrosion

Four superalloys were tested at 900 C in high velocity combustion gases containing synthetic sea salt and, in some cases, a chromium containing fuel additive. While the additive reduced hot corrosion of the alloys over the 100 hour test period, the attack was not eliminated nor was the mode of attack changed. Reduction of the number of thermal cycles had as large a beneficial effect as the Cr additive. Intermittent washing during testing had either small beneficial or adverse effects depending on the alloy.

Lowell, C. E.↗

The 737 graphite composite flight spoiler flight service evaluation

The flight service experience of 108 graphite-epoxy spoilers on 737 transport aircraft, and related ground-based environmental exposure of graphite-epoxy material specimens were evaluated. Four spoilers were installed on each of 27 aircraft for a 5-year study. As of February 28, 1975, a total of 294,280 spoiler flight-hours and 460,686 spoiler landings were accumulated. Based on visual, ultrasonic, and destructive testing, no moisture migration into the honeycomb core and no core corrosion has occurred. Tests of removed spoilers and of ground-based exposure specimens after the first year of service indicate no significant changes in composite strength.

Stoecklin, R. L.↗

Study program for encapsulation materials interface for low cost silicon solar array

An atmospheric corrosion model was developed and verified by five months of corrosion rate and climatology data acquired at the Mead, Nebraska LSA test site. Atmospheric corrosion rate monitors (ACM) show that moisture condensation probability and ionic conduction at the corroding surface or interface are controlling factors in corrosion rate. Protection of the corroding surface by encapsulant was shown by the ACM recordings to be maintained, independent of climatology, over the five months outdoor exposure period. The macroscopic corrosion processes which occur at Mead are shown to be reproduced in the climatology simulator. Controlled experiments with identical moisture and temperature aging cycles show that UV radiation causes corrosion while UV shielding inhibits LSA corrosion.

Kaelble, D. H.↗

Gas-turbine critical research and advanced technology support project

A technology data base for utility gas turbine systems capable of burning coal derived fuels was developed. The following areas are investigated: combustion; materials; and system studies. A two stage test rig is designed to study the conversion of fuel bound nitrogen to NOx. The feasibility of using heavy fuels in catalytic combustors is evaluated. A statistically designed series of hot corrosion burner rig tests was conducted to measure the corrosion rates of typical gas turbine alloys with several fuel contaminants. Fuel additives and several advanced thermal barrier coatings are tested. Thermal barrier coatings used in conjunction with low critical alloys and those used in a combined cycle system in which the stack temperature was maintained above the acid corrosion temperature are also studied.

Clark, J. S.↗

Evaluation Of Corrosion-Resistant Alloys for Use in Acidic and Marine Launch Environments at NASA Kennedy Space Center: 20-Year Study

After the completion of an initial three-year study to qualify corrosion-resistant stainless steel tubing for use in NASA Kennedy Space Center’s acidic and marine launch environment, test specimens remained exposed at the KSC Beachside Atmospheric Corrosion Test Site for long-term exposure. NASA KSC’s lifetime requirement for most ground support equipment is twenty years. After twenty-one years of marine exposure, NASA KSC took the unique opportunity to reevaluate the tubing after long-term exposure to better understand the corrosion resistance of these alloys as they reached their expected lifetime requirement. Metallurgical and corrosion analysis was performed on the CRES tubing components and the alloys were rated on performance. A summary of CRES alloy tubing corrosion-related performance after 20 years of exposure in a marine launch environment is presented in this work.

NASA KSC↗

Dissimilar metals joint evaluation

Dissimilar metals tubular joints between 2219-T851 aluminum alloy and 304L stainless steel were fabricated and tested to evaluate bonding processes. Joints were fabricated by four processes: (1) inertia (friction) weldings, where the metals are spun and forced together to create the weld; (2) explosive welding, where the metals are impacted together at high velocity; (3) co-extrusion, where the metals are extruded in contact at high temperature to promote diffusion; and (4) swaging, where residual stresses in the metals after a stretching operation maintain forced contact in mutual shear areas. Fifteen joints of each type were prepared and evaluated in a 6.35 cm (2.50 in.) O.D. size, with 0.32 cm (0.13 in.) wall thickness, and 7.6 cm (3.0 in) total length. The joints were tested to evaluate their ability to withstand pressure cycle, thermal cycle, galvanic corrosion and burst tests. Leakage tests and other non-destructive test techniques were used to evaluate the behavior of the joints, and the microstructure of the bond areas was analyzed.

Wakefield, M. E.↗