Calibration of passive remote observing optical and microwave instrumentation; Proceedings of the Meeting, Orlando, FL, Apr. 3-5, 1991

Various papers on the calibration of passive remote observing optical and microwave instrumentation are presented. Individual topics addressed include: on-board calibration device for a wide field-of-view instrument, calibration for the medium-resolution imaging spectrometer, cryogenic radiometers and intensity-stabilized lasers for EOS radiometric calibrations, radiometric stability of the Shuttle-borne solar backscatter ultraviolet spectrometer, ratioing radiometer for use with a solar diffuser, requirements of a solar diffuser and measurements of some candidate materials, reflectance stability analysis of Spectralon diffuse calibration panels, stray light effects on calibrations using a solar diffuser, radiometric calibration of SPOT 23 HRVs, surface and aerosol models for use in radiative transfer codes. Also addressed are: calibrated intercepts for solar radiometers used in remote sensor calibration, radiometric calibration of an airborne multispectral scanner, in-flight calibration of a helicopter-mounted Daedalus multispectral scanner, technique for improving the calibration of large-area sphere sources, remote colorimetry and its applications, spatial sampling errors for a satellite-borne scanning radiometer, calibration of EOS multispectral imaging sensors and solar irradiance variability.

Guenther, Bruce W.↗

Towards Automating Spacecraft Attitude Sensor Calibration

With a view towards reducing cost and complexity for spacecraft early mission support at the NASA Goddard Space Flight Center (GSFC), efforts are being made to automate the attitude sensor calibration process. This paper addresses one of the major components needed by such a system. The beneficiaries of an improved calibration process are missions that demand moderate to high precision attitude knowledge or that need to perform accurate attitude slews. Improved slew accuracy reduces the time needed for re-acquisition of fine-pointing after each attitude maneuver, Rapid target acquisition can be very important for astronomical targeting or for off-nadir surface feature targeting by Earth-oriented spacecraft. The normal sequence of on-orbit calibration starts with alignment calibration of the star trackers and possibly the Sun sensor. Their relative alignment needs to be determined using a sufficiently large data set so their fields of view are adequately sampled. Next, the inertial reference unit (IRU) is calibrated for corrections to its alignment and scale factors. The IRU biases are estimated continuously by the onboard attitude control system, but the IRU alignment and scale factors are usually determined on the ground using a batch-processing method on a data set that includes several slews sufficient to give full observability of all the IRU calibration parameters. Finally, magnetometer biases, alignment, and its coupling to the magnetic torquers are determined in order io improve momentum management and occasionally for use in the attitude determination system. The detailed approach used for automating calibrations will depend on whether the automated system resides on the ground or on the spacecraft with an ultimate goal of autonomous calibration. Current efforts focus on a ground-based system driving subsystems that could run either on the ground or onboard. The distinction is that onboard calibration should process the data sequentially rather than in a single large batch since onboard computer data storage is limited. Very good batch- processing calibration utilities have been developed and used extensively at NASA/GSFC for mission support but no sequential calibration utilities are available. To meet this need, this paper presents the mathematical description of a sequential IRU calibration system. The system has been tested using flight data from the Rossi X-ray Timing Explorer (RXTE) during a series of attitude slews. The paper also discusses the current state of the overall automated system and describes plans for adding sequential alignment calibration and other additions that will reduce the amount of analyst time and input.

Sedlak, Joseph↗

Calibration of the 11x11-Foot Transonic Wind Tunnel at NASA Ames Research Center

A static pipe calibration characterizing the streamwise static pressure distribution was conducted at the 11-By 11-Foot Transonic Wind Tunnel at NASA Ames Research Center. This data is used to determine the local Mach number within the test section and evaluate buoyancy corrections to axial force measurements. The 60 foot long, 6 inch diameter pipe contained 444 static pressure taps spanning the test section and nozzle regions of the tunnel. The forward end of the pipe extends into the settling chamber and is held by four cables mounting to the tunnel shell, and the aft end is fixed on the institutional model support system. A hydraulic cylinder at the aft end of the pipe provides tension on the system to reduce vibration and to keep the pipe as level as possible throughout the test section. The previous calibration was improved upon by using pressure scanners with greater accuracy, ensuring a uniform pressure tube length for each tap to control pneumatic lag, optically tracking any streamwise movement of the pipe, and more tightly controlling the tunnel condition set points. Typically this calibration is conducted with the pipe on tunnel centerline and 33 inches below centerline for sting-mounted models and semi-span (i.e. floor-mounted) models respectively, however schedule demands permitted only the centerline calibration. The semi-span calibration is planned to be completed in the summer of 2020. Immediately following the static pipe calibration, a shorter, 9 foot static pipe used as the calibration check standard was installed to obtain its first post-calibration pressure dataset. This short static pipe consists of 148 static pressure taps distributed along the pipe section and one total pressure tap at the end of an ogive nose. Performing the calibration test and its check standard back-to-back allows this dataset to establish a reliable baseline for future calibration check standard testing. Over time the use of a calibration check standard offers the ability to assess the stability of the calibration through statistical process control in an efficient and costeffective manner, thereby potentially increasing the time required between full tunnel calibrations.

White, Bethany↗

SNPP VIIRS Reflective Solar Bands On-Orbit Calibration Using the Moon

The Visible Infrared Imaging Radiometer Suite (VIIRS) on board the Suomi National Polar-Orbiting Partnership (SNPP) satellite has been on orbit for more than eight years since its launch on October 28, 2011. The VIIRS has 22 spectral bands, among which 14 are reflective solar bands(RSBs) covering a spectral range from 0.41 to 2.25 m. The VIIRS RSBs are primarily calibrated on-orbit by an onboard solar diffuser (SD) panel and a solar diffuser stability monitor (SDSM). Besides the SD and SDSM calibration, the RSBs are scheduled to view the Moon approximately monthly through the instrument’s space view (SV). The lunar observations have also been used to calibrate the RSBs on-orbit since early mission. Due to the non uniformity of the SD’s degradation, the calibration coefficients that are derived from the SD/SDSM calibration have long-term biases, especially at short wavelengths. In addition, the SDSM has no capability to monitor the SD degradation beyond 0.935 m, resulting in long-term bias in the shortwave infrared bands, about 0.72% for band M8 (1.238 m). These biases induce significant errors and long-term drifts in the VIIRS sensor data records (SDR) and consequently in the environmental data records (EDR). Unlike the SD, the Moon is a known stable target and any temporal drifts observed while viewing the Moon can be attributed to the sensor’s degradation. Thus, the VIIRS lunar calibration is used to track the RSB on-orbit changes, especially to provide an accurate long-term baseline. Due to the non-uniformity of the lunar surface, the lunar irradiance, instead of the lunar radiance, is used to calibrate the RSBs. The lunar irradiance strongly depends on lunar view geometry and it is still a challenge to accurately characterize the geometric effects associated with the lunar measurements and any residual errors can induce seasonal oscillations in the derived calibration coefficients. The errors of the geometric dependence correction induce seasonal oscillations in the derived RSB lunar calibration coefficients. In this paper, the algorithms for the view geometric effect correction are significantly improved, resulting in a significant reduction in the seasonal oscillations observed in the calibration coefficient time-series. The lunar and SD/SDSM calibration results are properly incorporated to generate a set of hybrid calibration coefficients and implementation of these coefficients is shown to significantly improve the long-term stability of the VIIRS SDR. This is of fundamental importance in making accurate Earth observations from which reliable and high quality science products are generated. The consequent improvements in SNPP VIIRS RSB SDRs and EDRs are shown and discussed. The lunar calibration methodology can be directly applied to follow-on VIIRS instruments.

Junqiang Sun↗

Automated Detection of Spurious Signals in VLBI Phase Calibration Data

In this memorandum, a set of processing strategies for automatic masking of phase calibration tones is outlined as implemented in the software package PIMA in the task Generate Phase Calibration Mask, or GEPM. The task relies on a robust procedure of cleaning phase calibration data before employing several mathematical strategies designed to selectively identify spurious signals from phase calibration tones. These strategies were derived as more rigorous implementations of heuristics traditionally used by analysts in manually identifying problematic phase calibration data. The task is intended to automate the process of generating a phase calibration mask and in so doing increase the speed and regularity of VLBI analysis. At the outset of the project, a series of goals were identified to evaluate the success of this mask generation. This included the development of an algorithm to identify and mask short-term (defined as less than 10 seconds in length) spurious signals affecting phase calibration data, the development of an algorithm to identify and mask phase calibration tones affected by constant radio-frequency interference, the implementation of a detection scheme for identifying large jumps in phase calibration phase caused by clock breaks, and finally a method of reporting phase calibration health metrics to the user. Processing of over 10 experiments has demonstrated that the final form of the task GEPM as detailed in this technical memorandum satisfies each of these conditions and satisfactorily performs the task of automatic phase calibration data masking, although the wide variety in quality and characteristics of phase calibration data makes a single solution to the problem quite difficult. A series of user inputs have therefore been defined to assist analysts in tailoring automatic masking to specific stations and phase calibration generators. The vast majority of applicable code was written in FORTRAN to increase execution speed and ease of interfacing with the existing code base in PIMA, but a wrapper function in Python was also written to allow for a simpler method of interacting with GEPM and inputting relevant parameters. In addition to this report, thorough documentation was added to the already existing repositories associated with PIMA as a whole.

Geodesy↗

Radon-222 Charcoal Canister Steady State Model Calibrations Performed in a Highly Controlled Environmental Chamber and a Natural Indoor Environment

Charcoal canisters are a common method of 222 Rn screening. The calibrations of different batches of activated charcoal used in different canister designs are typically performed in large volume controlled environmental chambers with known and controlled radon concentration, temperature, and humidity. Radon screening could be facilitated in locations without ready access to environmental chambers if canisters could be accurately calibrated and undergo quality control in less controlled environments. This study compares charcoal canister calibrations from a highly controlled radon chamber with calibrations from a basement storage area experiencing temporally varying radon. In addition, the impacts of exposure time and spectral region of interest selection on calibration accuracy are investigated by comparing calibrations calculated using three different choices. Approximately 30 mo after calibrations were completed, groups of canisters were exposed for different durations of time to investigate measurement accuracy and calibration validity over an extended time. A digital simulation of charcoal canister kinetics was also performed to establish limits on how stable radon must be in a space for equilibrium-based calibration to be performed there. Overall, the accuracy of measurements using calibrations from each space differed by less than 10% after 2 d exposure time, showing that carefully controlled conditions are not necessary for the accurate calibration of charcoal canisters. Furthermore, measurement accuracy differed by less than 2% for different spectral region selections. Accuracy improved slightly with canister exposure duration. Simulations suggest that radon instability is most tolerable near the beginning of canister calibration exposures, but this merits further experimental study.

07 ISOTOPE AND RADIATION SOURCES↗

MODIS Aqua Reflective Solar Bands Calibration for NASA's R2018 Ocean Color Products

Remote sensing ocean color products have stringent requirements on radiometric calibration stability. To address a calibration deficiency in MODIS Aqua in recent years, the NASA Ocean Biological Processing Group (OBPG) developed a new calibration for the reflective solar bands. Prior to the reprocessing of NASA's ocean color products for 2018 (R2018), the OBPG MODIS products had been based on calibration provided by the MODIS Calibration Support Team (MCST). Several modifications were made to the MCST calibration approach to improve the calibration accuracy for ocean color products. These include: 1) apply 936nm detector normalization to solar diffuser stability monitor (SDSM) data to reduce coherent noise; 2) modeling solar diffuser (SD) degradation wavelength dependency to determine SD degradation in near-infrared and shortwave infrared wavelength; 3) detector gains are computed using SD screen-closed data to better match ocean radiance levels in all bands; 4) a simple atmospheric correction is performed to reduce bidirectional reflectance distribution function (BRDF) effects in desert trends; 5) modulated relative spectral response (RSR) impact on ocean data is estimated and used to adjust the calibration coefficients. 6) smoothing is used to characterize the temporal change in calibration, and response versus scan angle (RVS) changes are characterized using 2nd order polynomials to improve spatial/temporal calibration stability. Relative to the previous R2014 ocean color products, the R2018 calibration removed the suspect late-mission global trends in blue-band water-leaving reflectance, and some anomalously large short-term variability (spikes) in the temporal trend of chlorophyll concentration. This paper will describe the OBPG calibration with a focus on the differences between the MCST and OBPG approaches.

calibration↗

Balance Calibration – A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance.

Paper Title: Balance Calibration – A method for assigning a direct-reading uncertainty to an electronic balance. Intended Audience: Those who calibrate or use electronic balances. Abstract: As a calibration facility, we provide on-site (at the customer’s location) calibrations of electronic balances for customers within our company. In our experience, most of our customers are not using their balance as a comparator, but simply putting an unknown quantity on the balance and reading the displayed mass value. Manufacturer’s specifications for balances typically include specifications such as readability, repeatability, linearity, and sensitivity temperature drift, but what does this all mean when the balance user simply reads the displayed mass value and accepts the reading as the true value? This paper discusses a method for assigning a direct-reading uncertainty to a balance based upon the observed calibration data and the environment where the balance is being used. The method requires input from the customer regarding the environment where the balance is used and encourages discussion with the customer regarding sources of uncertainty and possible means for improvement; the calibration process becomes an educational opportunity for the balance user as well as calibration personnel. This paper will cover the uncertainty analysis applied to the calibration weights used for the field calibration of balances; the uncertainty is calculated over the range of environmental conditions typically encountered in the field and the resulting range of air density. The temperature stability in the area of the balance is discussed with the customer and the temperature range over which the balance calibration is valid is decided upon; the decision is based upon the uncertainty needs of the customer and the desired rigor in monitoring by the customer. Once the environmental limitations are decided, the calibration is performed and the measurement data is entered into a custom spreadsheet. The spreadsheet uses measurement results, along with the manufacturer’s specifications, to assign a direct-read measurement uncertainty to the balance. The fact that the assigned uncertainty is a best-case uncertainty is discussed with the customer; the assigned uncertainty contains no allowance for contributions associated with the unknown weighing sample, such as density, static charges, magnetism, etc. The attendee will learn uncertainty considerations associated with balance calibrations along with one method for assigning an uncertainty to a balance used for non-comparison measurements.

47 OTHER INSTRUMENTATION↗

Automated Internal Energy Calibration by OnTheFly for AGR-5/6/7

The software program, OnTheFly, was developed at Idaho National Laboratory (INL) to keep high-purity germanium (HPGe) detectors energy calibrated during very long experiments. Over time, spectra produced from a HPGe detector will slowly stretch or contract, causing the energy calibration to change. If the energy calibration changes too much, it will cause energy lines to be misidentified. The higher the energy line the more affected they are by this change. OnTheFly tracks and adjusts the slowly changing energy calibrations so the energy lines will not be misidentified. OnTheFly was used with the Fission Product Monitoring System (FPMS) during the AGR-5/6/7 irradiation experiment performed at INL’s Advanced Test Reactor (ATR). Five HPGe detectors were used to monitor the five capsules in AGR-5/6/7. There were also two extra HPGe detectors that were maintained as spares. Before each ATR cycle of the experiment, the HPGe detectors were energy calibrated with a thorium radioactive source. During each ATR cycle, each detector would acquire data for 8 hours and then reset and acquire data for another 8 hours. After each 8-hour run, the spectra would be saved and analyzed autonomously. The results were then read by OnTheFly and used to produce a new energy calibration for each detector. The new energy calibrations were compared to the current energy calibrations and, if certain criteria were met, the new energy calibration would replace the current energy calibration. The new energy calibration would be used for future spectra. OnTheFly was run at least every couple of days but could be run as much as after each 8-hour run. OnTheFly kept the spectra energy calibrated during the ATR cycles over the 2 years and 5 months that the AGR-5/6/7 experiment ran.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mercury Continuous Emmission Monitor Calibration

Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry (ID/ICP/MS) performed by NIST in Gaithersburg, MD. The outputs of mercury calibrators are compared to one another using a nesting procedure which allows direct comparison of one calibrator with another at specific concentrations and eliminates analyzer variability effects. The qualification portion of the EPA interim traceability protocol requires the vendors to define calibrator performance as affected by variables such as pressure, temperature, line voltage, and shipping. In 2007 WRI developed and conducted a series of simplified qualification experiments to determine actual calibrator performance related to the variables defined in the qualification portion of the interim protocol.

01 COAL, LIGNITE, AND PEAT↗

Improved Detection System Description and New Method for Accurate Calibration of Micro-Channel Plate Based Instruments and Its Use in the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The Fast Plasma Investigation (FPI) on NASAs Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30 ms for electrons; 150 ms for ions) and spatially differentiated measurements of the full 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity, the reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions of magnetically reconnecting plasmas. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated using the plateau curve technique. In this, a fixed detection threshold is set. The detection system count rate is then measured as a function of MCP voltage to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection system discrimination threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully describe the behavior of the detection system and individually characterize each of its fundamental parameters. To improve this situation, we have developed a detailed phenomenological description of the detection system, its behavior and its signal, crosstalk and noise sources. Based on this, we have devised a new detection system calibration method that enables accurate and repeatable measurement and calibration of MCP gain, MCP efficiency, signal loss due to variation in gain and efficiency, crosstalk from effects both above and below the MCP, noise margin, and stability margin in one single measurement. More precise calibration is highly desirable as the instruments will produce higher quality raw data that will require less post-acquisition data correction using results from in-flight pitch angle distribution measurements and ground calibration measurements. The detection system description and the fundamental concepts of this new calibration method, named threshold scan, will be presented. It will be shown how to derive all the individual detection system parameters and how to choose the optimum detection system operating point. This new method has been successfully applied to achieve a highly accurate calibration of the DESs and DISs of the MMS mission. The practical application of the method will be presented together with the achieved calibration results and their significance. Finally, it will be shown that, with further detailed modeling, this method can be extended for use in flight to achieve and maintain a highly accurate detection system calibration across a large number of instruments during the mission.

detection system↗

The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint

Accurate solar radiation data sets are critical to reducing the expenses associated with mitigating performance risk for solar energy conversion systems, and they help utility planners and grid system operators understand the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of calibration methodologies and the resulting calibration responsivities provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these radiometers are calibrated indoors, and some are calibrated outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The reference radiometer calibrations are traceable to the World Radiometric Reference. These different methods of calibration demonstrated 1% to 2% differences in solar irradiance measurement. Analyzing these values will ultimately assist in determining the uncertainties of the radiometer data and will assist in developing consensus on a standard for calibration.

14 SOLAR ENERGY↗

Special report, cross calibration of JHU test equipment with GSFC vacuum optical bench

Tests were conducted to confirm the validity of the absolute calibrations which have been performed with the Apollo 17 ultraviolet spectrometer (UVS) in the calibration test equipment (CTE) which were constructed for that purpose. To accomplish this the prototype UV spectrometer SN/01 was retrofitted to be substantially identical to the qualification unit and to the two flight units. It was renamed the cross calibration unit (CCU). The instrument was first calibrated in the JHU calibration test equipment (CTE), then installed in the vacuum optical bench (VOB) at Goddard Space Flight Center and calibrated. The following day a second CTE calibration was conducted which provided substantially the same calibration values as were obtained on the first CTE calibration, and showed remarkably close agreement with the VOB calibration values at two of the wavelengths which were studied. The VOB results at the third wavelength (1216 A) indicate the CTE calibration at 1216 A is 15% too low. This apparent discrepancy is discussed and presents a very important result of the cross calibration effort.

Fastie, W. G.↗

AVIRIS Inflight Calibration Experiments, Analysis, and Results in 2000

The NASA Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measures spectra from 370 to 2500 nm with nominally 10-nm sampling and resolution. The spectra are acquired as images with an 11 km width and up to 800 km length from the ER-2 platform or 2.1 km width and 160 km length from the Twin Otter platform. AVIRIS measurements are used for a range of Earth science research and application objectives. The molecular absorption and particle scattering properties expressed in the calibrated AVIRIS measurements are used. For both science research and application objectives, calibration of the AVIRIS spectra is required to produce useful results. Each year prior to the flight season AVIRIS is calibrated in the laboratory. However, the temperature, pressure, vibration, and observational geometry, as well as mechanical, electrical, and operational interfaces of the laboratory are different than the environment on board the airborne platform. To validate the calibration of AVIRIS in the flight environment, an inflight calibration experiment is orchestrated at the beginning of each flight season. In most years additional inflight calibration experiments occur towards the middle and end of the flight season as well. For an inflight calibration experiment, AVIRIS acquires airborne data over a designated calibration target. In concert with the airborne data acquisition, surface and atmospheric properties at the calibration target are measured in situ. These in situ measurements are used to constrain a radiative transfer code and predict the radiance incident at the AVIRIS instrument from the calibration target. This prediction is compared with the AVIRIS-measured radiance to validate the calibration of AVIRIS in the flight environment. Additional properties (such as the AVIRIS inflight measurement precision) are determined as well. This paper presents measurements, analyses, and results from the inflight calibration experiment held on the dry lake bed surface of Rogers Dry Lake, California, on June 5, 2000.

Green, Robert O.↗

An Overview of Inter-comparison Methodologies for Terra and Aqua MODIS Calibration

With increasing efforts on data fusion and long-term climate data records (CDR) using observations made by multiple sensors, on the same or different platforms, their cross-calibration and validation work has become more and more important. The uncertainties of the climate models and data records depend not only on the calibration quality of individual sensors but also on their calibration consistency. This paper provides an overview of methodologies used by the MODIS Characterization Support Team (MCST) at NASA GSFC for the inter-comparison studies of Terra and Aqua MODIS on-orbit calibration. Each MODIS was built with a set of onboard calibrators (OBC) that include a blackbody (BB), a solar diffuser (SD), and a solar diffuser stability monitor (SDSM). The BB is primarily used for the thermal emissive bands (TEB) calibration and the SD/SDSM system for the reflective solar bands (RSB) calibration. Although the-instrument design and calibration approach are nearly identical for both Terra and Aqua MODIS and they all went through an extensive and similar pre-launch calibration and characterization process, still their on-orbit calibration consistency needs to be carefully examined and validated as many science products have been generated from observations made by both instruments. Methodologies discussed in this paper include inter-comparison studies using the Moon, a third sensor, and ground targets. Our results show that Terra and Aqua reflective solar bands and thermal emissive bands have been calibrated consistently with excellent long-term stabilities. For the 11 and 12 micrometers sea surface temperature (SST) bands, the calibration difference of Terra and Aqua MODIS is less than 0.2K.

Xiong, X.↗

MIRO Continuum Calibration for Asteroid Mode

MIRO (Microwave Instrument for the Rosetta Orbiter) is a lightweight, uncooled, dual-frequency heterodyne radiometer. The MIRO encountered asteroid Steins in 2008, and during the flyby, MIRO used the Asteroid Mode to measure the emission spectrum of Steins. The Asteroid Mode is one of the seven modes of the MIRO operation, and is designed to increase the length of time that a spectral line is in the MIRO pass-band during a flyby of an object. This software is used to calibrate the continuum measurement of Steins emission power during the asteroid flyby. The MIRO raw measurement data need to be calibrated in order to obtain physically meaningful data. This software calibrates the MIRO raw measurements in digital units to the brightness temperature in Kelvin. The software uses two calibration sequences that are included in the Asteroid Mode. One sequence is at the beginning of the mode, and the other at the end. The first six frames contain the measurement of a cold calibration target, while the last six frames measure a warm calibration target. The targets have known temperatures and are used to provide reference power and gain, which can be used to convert MIRO measurements into brightness temperature. The software was developed to calibrate MIRO continuum measurements from Asteroid Mode. The software determines the relationship between the raw digital unit measured by MIRO and the equivalent brightness temperature by analyzing data from calibration frames. The found relationship is applied to non-calibration frames, which are the measurements of an object of interest such as asteroids and other planetary objects that MIRO encounters during its operation. This software characterizes the gain fluctuations statistically and determines which method to estimate gain between calibration frames. For example, if the fluctuation is lower than a statistically significant level, the averaging method is used to estimate the gain between the calibration frames. If the fluctuation is found to be statistically significant, a linear interpolation of gain and reference power is used to estimate the gain between the calibration frames.

Lee, Seungwon↗

MODIS On-orbit Calibration Uncertainty Assessment

MODIS has 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration uncertainty requirements. As a result, MODIS was designed and built with a set of on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and an in-depth analysis of its on-orbit calibration uncertainties. Also discussed in this paper are uncertainty contributions from individual components and differences due to Terra and Aqua MODIS instrument characteristics and on-orbit performance.

Chiang, Vincent↗

MODIS Radiometric Calibration and Uncertainty Assessment

Since launch, Terra and Aqua MODIS have collected more than II and 9 years of datasets for comprehensive studies of the Earth's land, ocean, and atmospheric properties. MODIS observations are made in 36 spectral bands: 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration and uncertainty requirements. As a result, MODIS was designed and built with a set of state of the art on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated if necessary. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and discusses details of its on-orbit calibration uncertainties. It assesses uncertainty contributions from individual components and differences between Terra and Aqua MODIS due to their design characteristics and on-orbit periormance. Also discussed in this paper is the use of MODIS LIB uncertainty index CUI) product.

Xiong, Xiaoxiong↗