Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibrating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

MODIS On-Orbit Calibration and Lessons Learned

The Moderate Resolution Imaging Spectroradiometer (MODIS) is a key instrument for NASA's Earth Observing System (EOS) Terra and Aqua missions. Since launch, Terra and Aqua MODIS have successfully operated for more than 12 and 10 years, respectively, and generated an unprecedented amount of data products for the science and user community over a wide range of applications. MODIS was developed with improved design and stringent calibration requirements over its heritage sensors in order . to extend and enhance their long-term data records. Its follow-on instrument, the Visible/Infrared Imager Radiometer Suite (VIIRS), was launched on-board the Suomi National Polar-orbiting Partnership (NPP) spacecraft October 28, 2011. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.S!Jlll, and at 250m, SOOm, and lkm spatial resolutions (nadir). MODIS on-orbit calibration is provided by a set of onboard calibrators (OBC), including a solar diffuser (SO), a solar diffuser stability monitor (SDSM), a blackbody (BB), and a spectroradiometric calibration assembly (SRCA). In addition to the onboard calibrators, regular lunar observations are made by both Terra and Aqua MODIS to track their calibration stability in the reflective solar region. This tutorial session provides an overview of MODIS on-orbit calibration and characterization methodologies. It discusses challenging issues and lessons learned from sensor design, operation, calibration, and inter-comparisons. Examples of instrument on-orbit performance are illustrated with a focus on the improvements made based on various lessons learned. It is expected that MODIS experience and lessons will continue to provide valuable information for future earth observing missions/sensors.

Xiong, Jack↗

A Full-Envelope Air Data Calibration and Three-Dimensional Wind Estimation Method Using Global Output-Error Optimization and Flight-Test Techniques

A novel, efficient air data calibration method is proposed for aircraft with limited envelopes. This method uses output-error optimization on three-dimensional inertial velocities to estimate calibration and wind parameters. Calibration parameters are based on assumed calibration models for static pressure, angle of attack, and flank angle. Estimated wind parameters are the north, east, and down components. The only assumptions needed for this method are that the inertial velocities and Euler angles are accurate, the calibration models are correct, and that the steady-state component of wind is constant throughout the maneuver. A two-minute maneuver was designed to excite the aircraft over the range of air data calibration parameters and de-correlate the angle-of-attack bias from the vertical component of wind. Simulation of the X-48B (The Boeing Company, Chicago, Illinois) aircraft was used to validate the method, ultimately using data derived from wind-tunnel testing to simulate the un-calibrated air data measurements. Results from the simulation were accurate and robust to turbulence levels comparable to those observed in flight. Future experiments are planned to evaluate the proposed air data calibration in a flight environment.

Taylor, Brian R.↗

Calibration and Sequence Development Status for the Sample Analysis at Mars Investigation on the Mars Science Laboratory

The measurement goals of the Sample Analysis at Mars (SAM) instrument suite on the "Curiosity" Rover of the Mars Science Laboratory (MSL) include chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples [1,2]. SAM directly supports the ambitious goals of the MSL mission to provide a quantitative assessment of habitability and preservation in Gale crater by means of a range of chemical and geological measurements [3]. The SAM FM combined calibration and environmental testing took place primarily in 2010 with a limited set of tests implemented after integration into the rover in January 2011. The scope of SAM FM testing was limited both to preserve SAM consumables such as life time of its electromechanical elements and to minimize the level of terrestrial contamination in the SAM instrument. A more comprehensive calibration of a SAM-like suite of instruments will be implemented in 2012 with calibration runs planned for the SAM testbed. The SAM Testbed is nearly identical to the SAM FM and operates in a ambient pressure chamber. The SAM Instrument Suite: SAM's instruments are a Quadrupole Mass Spectrometer (QMS), a 6-column Gas Chromatograph (GC), and a 2-channel Tunable Laser Spectrometer (TLS). Gas Chromatography Mass Spectrometry is designed for identification of even trace organic compounds. The TLS [5] secures the C, H, and O isotopic composition in carbon dioxide, water, and methane. Sieved materials are delivered from the MSL sample acquisition and processing system to one of68 cups of the Sample Manipulation System (SMS). 59 of these cups are fabricated from inert quartz. After sample delivery, a cup is inserted into one of 2 ovens for evolved gas analysis (EGA ambient to >9500C) by the QMS and TLS. A portion of the gas released can be trapped and subsequently analyzed by GCMS. Nine sealed cups contain liquid solvents and chemical derivatization or thermochemolysis agents to extract and transform polar molecules such as amino acids, nucleobases, and carboxylic acids into compounds that are sufficiently volatile to transmit through the GC columns. The remaining 6 cups contain calibrants. SAM FM Calibration Overview: The SAM FM calibration in the Mars chamber employed a variety of pure gases, gas mixtures, and solid materials. Isotope calibration runs for the TLS utilized 13C enriched C02 standards and 0 enriched CH4. A variety of fluorocarbon compounds that spanned the entire mass range of the QMS as well as C3-C6 hydrocarbons were utilized for calibration of the GCMS. Solid samples consisting of a mixture of calcite, melanterite, and inert silica glass either doped or not with fluorocarbons were introduced into the SAM FM cups through the SAM inlet funnel/tube system.

Mahaffy, Paul R.↗

Calibration Variable Selection and Natural Zero Determination for Semispan and Canard Balances

Independent calibration variables for the characterization of semispan and canard wind tunnel balances are discussed. It is shown that the variable selection for a semispan balance is determined by the location of the resultant normal and axial forces that act on the balance. These two forces are the first and second calibration variable. The pitching moment becomes the third calibration variable after the normal and axial forces are shifted to the pitch axis of the balance. Two geometric distances, i.e., the rolling and yawing moment arms, are the fourth and fifth calibration variable. They are traditionally substituted by corresponding moments to simplify the use of calibration data during a wind tunnel test. A canard balance is related to a semispan balance. It also only measures loads on one half of a lifting surface. However, the axial force and yawing moment are of no interest to users of a canard balance. Therefore, its calibration variable set is reduced to the normal force, pitching moment, and rolling moment. The combined load diagrams of the rolling and yawing moment for a semispan balance are discussed. They may be used to illustrate connections between the wind tunnel model geometry, the test section size, and the calibration load schedule. Then, methods are reviewed that may be used to obtain the natural zeros of a semispan or canard balance. In addition, characteristics of three semispan balance calibration rigs are discussed. Finally, basic requirements for a full characterization of a semispan balance are reviewed.

Ulbrich, Norbert M.↗

Calibration of the DSCOVR EPIC Visible and NIR Channels using MODIS Terra and Aqua Data and EPIC Lunar Observations

The unique position of the Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) at the Lagrange 1 point makes an important addition to the data from currently operating low Earth orbit observing instruments. EPIC instrument does not have an onboard calibration facility. One approach to its calibration is to compare EPIC observations to the measurements from polar-orbiting radiometers. Moderate Resolution Imaging Spectroradiometer (MODIS) is a natural choice for such comparison due to its well-established calibration record and wide use in remote sensing. We use MODIS Aqua and Terra L1B 1km reflectances to infer calibration coefficients for four EPIC visible and NIR channels: 443, 551, 680 and 780 nm. MODIS and EPIC measurements made between June 2015 and 2016 are employed for comparison. We first identify favorable MODIS pixels with scattering angle matching temporarily collocated EPIC observations. Each EPIC pixel is then spatially collocated to a subset of the favorable MODIS pixels within 25 km radius. Standard deviation of the selected MODIS pixels as well as of the adjacent EPIC pixels is used to find the most homogeneous scenes. These scenes are then used to determine calibration coefficients using a linear regression between EPIC counts/sec and reflectances in the close MODIS spectral channels. We present thus inferred EPIC calibration coefficients and discuss sources of uncertainties. The lunar EPIC observations are used to calibrate EPIC O2 absorbing channels (688 and 764 nm), assuming that there is a small difference between moon reflectances separated by approx.10 nm in wavelength provided the calibration factors of the red (680 nm) and near-IR (780 nm) are known from comparison between EPIC and MODIS.

Geogdzhayev, Igor V.↗

A Consistent EPIC Visible Channel Calibration using VIIRS and MODIS as a Reference

The Earth Polychromatic Imaging Camera (EPIC) aboard the Deep Space Climate Observatory (DSCOVR) satellite constantly images the sunlit disk of Earth from the Lagrange-1 (L1) point in 10 spectral channels spanning the UV, VIS, and NIR spectrums. Recently, the DSCOVR EPIC team has publicly released version 2 dataset, which has implemented improved navigation, stray-light correction, and flat-fielding of the CCD array. The EPIC 2-year data record must be well-calibrated for consistent cloud, aerosol, trace gas, land use and other retrievals. Because EPIC lacks onboard calibrators, the observations made by EPIC channels must be calibrated vicariously using the coincident measurements from radiometrically stable instruments that have onboard calibration systems. MODIS and VIIRS are best-suited instruments for this task as they contain similar spectral bands that are well-calibrated onboard using solar diffusers and lunar tracking. We have previously calibrated the EPIC version 1 dataset by using EPIC and VIIRS angularly matched radiance pairs over both all-sky ocean and deep convective clouds (DCC). We noted that the EPIC image required navigations adjustments, and that the EPIC stray-light correction provided an offset term closer to zero based on the linear regression of the EPIC and VIIRS ray-matched radiance pairs. We will evaluate the EPIC version 2 navigation and stray-light improvements using the same techniques. In addition, we will monitor the EPIC channel calibration over the two years for any temporal degradation or anomalous behavior. These two calibration methods will be further validated using desert and DCC invariant Earth targets. The radiometric characterization of the selected invariant targets is performed using multiple years of MODIS and VIIRS measurements. Results of these studies will be shown at the conference.

Haney, C. O.↗

Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Calibration System

As a continuing effort to increase the calibration accuracy of the AVIRIS data a number of recent improvements have been implemented and are in the process of being tested during the 1994 flight season. These include the following innovations: A direct observation of a laboratory radiance standard is now used to double check the wide field-of-view calibration via an integrating sphere source. Launch site field calibration of the AVIRIS sensor is now being planned to augment the laboratory and inflight calibration. Modification to a dry air conditioning unit has been made to enable ground calibration at flight operating temperatures. One hundred lines of dark imagery has been added to the end of each flight line to assist in the analysis and removal of residual coherent noise. The intensity of the onboard calibration lamp has been modified to improve response in the blue end of the spectrum. Novel spectral filters have been installed in the onboard calibration source.

Airborne Visible/Infrared Imaging Spectrometer Cal↗

MODIS and VIIRS Calibration History and Future Outlook

The MODIS is a key instrument for NASA’s EOS program, currently operated onboard the Terra and Aqua spacecraft launched in 1999 and 2002, respectively. The VIIRS is a MODIS follow-on instrument for the JPSS program. Adding to the ones operated onboard the S-NPP and NOAA-20 satellites launched in 2011 and 2017, respectively, three nearly identical VIIRS instruments will also be launched. This will enable the data records from MODIS and VIIRS to be extended beyond 2040. In addition to various applications and scientific studies of the Earth’s system, long-term data records from MODIS and VIIRS observations will greatly benefit the space-based climate observing system. This is attributed to the high-quality measurements and extensive calibration efforts, from pre-launch to post-launch. This paper provides an overview of MODIS and VIIRS calibration history and approaches applied to establish and maintain sensor calibration traceability and accuracy. It illustrates calibration and performance issues through different phases of the mission using examples derived from ground testing equipment, on-board calibrators, and other calibration targets. Moreover, discussed in this paper are outstanding challenges and future efforts to maintain and improve sensor calibration stability and long-term data quality, and to better support the space-based climate observing system.

MODIS↗

Terra MODIS: 20 years of on-orbit calibration and performance

For nearly 20 years, Terra MODIS observations have generated a broad range of data products, enabling the remote sensing community and users worldwide for their studies of many key geophysical parameters of the Earth’s system. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.4 μm, that are calibrated by a set of on-board calibrators (OBC). Also contributed to sensor on-orbit calibration and characterization are near monthly-scheduled lunar observations and long-term trends of sensor responses over select ground targets. The quality of MODIS data products relies strongly on the dedicated efforts to the operate instrument, derive and update calibration parameters, and improve calibration strategies and algorithms in order to address on-orbit changes of sensor characteristics and its OBC functions. This paper provides an overview of Terra MODIS on-orbit operation and calibration activities over the last 20 years, including changes made to extend and preserve instrument and OBC functions and their implementation strategies. It illustrates sensor on-orbit performance using data from its OBC, lunar observations, and select ground targets and discusses major changes in sensor characteristics and corrections applied to the L1B algorithms or updates of calibration look-up tables (LUTs). Also described in this paper are lessons learned from Terra MODIS and future efforts to further extend its long-term data records.

Terra↗

A Synthesis of VIIRS Solar and Lunar Calibrations

The NASA VIIRS Ocean Science Team (VOST) has developed two independent calibrations of the SNPP VIIRS moderate resolution reflective solar bands using solar diffuser and lunar observations through June 2013. Fits to the solar calibration time series show mean residuals per band of 0.078-0.10%. There are apparent residual lunar libration correlations in the lunar calibration time series that are not accounted for by the ROLO photometric model of the Moon. Fits to the lunar time series that account for residual librations show mean residuals per band of 0.071-0.17%. Comparison of the solar and lunar time series shows that the relative differences in the two calibrations are 0.12-0.31%. Relative uncertainties in the VIIRS solar and lunar calibration time series are comparable to those achieved for SeaWiFS, Aqua MODIS, and Terra MODIS. Intercomparison of the VIIRS lunar time series with those from SeaWiFS, Aqua MODIS, and Terra MODIS shows that the scatter in the VIIRS lunar observations is consistent with that observed for the heritage instruments. Based on these analyses, the VOST has derived a calibration lookup table for VIIRS ocean color data based on fits to the solar calibration time series.

Calibrations↗

Assessment of New Load Schedules for the Machine Calibration of a Force Balance

New load schedules for the machine calibration of a six-component force balance are currently being developed and evaluated at the NASA Ames Balance Calibration Laboratory. One of the proposed load schedules is discussed in the paper. It has a total of 2082 points that are distributed across 16 load series. Several criteria were applied to define the load schedule. It was decided, for example, to specify the calibration load set in force balance format as this approach greatly simplifies the definition of the lower and upper bounds of the load schedule. In addition, all loads are assumed to be applied in a calibration machine by using the one-factor-at-a-time approach. At first, all single-component loads are applied in six load series. Then, three two-component load series are applied. They consist of the load pairs (N1, N2), (S1, S2), and (RM, AF). Afterwards, four three-component load series are applied. They consist of the combinations (N1, N2, AF), (S1, S2, AF), (N1, N2, RM), and (S1, S2, RM). In the next step, one four-component load series is applied. It is the load combination (N1, N2, S1, S2). Finally, two five-component load series are applied. They are the load combination (N1, N2, S1, S2, AF) and (N1, N2, S1, S2, RM). The maximum difference between loads of two subsequent data points of the load schedule is limited to 33 % of capacity. This constraint helps avoid unwanted load "jumps" in the load schedule that can have a negative impact on the performance of a calibration machine. Only loadings of the single- and two-component load series are loaded to 100 % of capacity. This approach was selected because it keeps the total number of calibration points to a reasonable limit while still allowing for the application of some of the more complex load combinations. Data from two of NASA's force balances is used to illustrate important characteristics of the proposed 2082-point calibration load schedule.

wind tunnel testing↗

SIM-Lite Mission Spectral Calibration Sensitivities and Refinements

SIM-Lite missions will perform astrometry at microarcsecond accuracy using star light interferometry. For typical baselines that are shorter than 10 meters, this requires to measure optical path difference (OPD) accurate to tens of picometers calling for highly accurate calibration. A major challenge is to calibrate the star spectral dependency in fringe measurements -- the spectral calibration. Previously, we have developed a spectral calibration and estimation scheme achieving picometer level accuracy. In this paper, we present the improvements regarding the application of this scheme from sensitivity studies. Data from the SIM Spectral Calibration Development Unit (SCDU) test facility shows that the fringe OPD is very sensitive to pointings of both beams from the two arms of the interferometer. This sensitivity coupled with a systematic pointing error provides a mechanism to explain the bias changes in 2007. Improving system alignment can effectively reduce this sensitivity and thus errors due to pointing errors. Modeling this sensitivity can lead to further improvement in data processing. We then investigate the sensitivity to a model parameter, the bandwidth used in the fringe model, which presents an interesting trade between systematic and random errors. Finally we show the mitigation of calibration errors due to system drifts by interpolating instrument calibrations. These improvements enable us to use SCDU data to demonstrate that SIM-Lite missions can meet the 1pm noise floor requirement for detecting earth-like exoplanets.

wave front aberration↗

Laser Calibration of an Impact Disdrometer

A practical approach to developing an operational low-cost disdrometer hinges on implementing an effective in situ adaptive calibration strategy. This calibration strategy lowers the cost of the device and provides a method to guarantee continued automatic calibration. In previous work, a collocated tipping bucket rain gauge was utilized to provide a calibration signal to the disdrometer's digital signal processing software. Rainfall rate is proportional to the 11/3 moment of the drop size distribution (a 7/2 moment can also be assumed, depending on the choice of terminal velocity relationship). In the previous case, the disdrometer calibration was characterized and weighted to the 11/3 moment of the drop size distribution (DSD). Optical extinction by rainfall is proportional to the 2nd moment of the DSD. Using visible laser light as a means to focus and generate an auxiliary calibration signal, the adaptive calibration processing is significantly improved.

calibration↗

Soil Moisture Active/Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration Upgrade

Current performance and existing problems in SMAP radiometer L1B_TB version 3 data product are described. The post-launch calibration algorithm has been updated by calibrating the three calibration parameters (the equivalent noise temperature of the noise diode, the offset of the reference load, and the antenna gain) jointly by using the global ocean and CS with both 110o and 180o pitch maneuvers after the reflector emissivity is calibrated. The results show that both calibration drift during eclipse season and bias over CS are removed. The RMSDs of the calibration drift over both the global ocean and CS are less than 0.1 K, and the goals of the calibration algorithm upgrade are achieved for coming L1B_TB version 4 data release.

Validation↗

The Inter-Calibration of the DSCOVR EPIC Imager 2 with Aqua-MODIS and NPP-VIIRS

The Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) continuously observes the illuminated disk from the Lagrange-1 point. The EPIC sensor was designed to monitor the diurnal variation of ozone, clouds, aerosols, and vegetation, especially those features that benefit from observation near-backscatter conditions. The EPIC sensor does not contain any onboard calibration systems. This study describes the inter-calibration of EPIC channels 5 (0.44 μm), 6 (0.55 μm), 7 (0.68 μm), and 10 (0.78 μm) with respect to Aqua-MODIS and NPP-VIIRS. The calibration is transferred using coincident ray-matched reflectance pairs over all-sky tropical ocean (ATO) and deep convective cloud (DCC) targets. A robust and automated image-alignment technique based on feature matching was formulated to improve the navigation quality of the EPIC images. The EPIC V02 dataset exhibits improved navigation over V01. Because the visible channels display similar spatial features, a single visible channel can be used to co-register the remaining visible bands. The VIIRS-referenced EPIC ATO and DCC ray-matched calibration coefficients are within 0.3%. The EPIC four-year calibration trends based on VIIRS are within 0.15%/year. The MODIS-based EPIC calibration coefficients were compared against the Geogdzhayev and Marshak 2018 published calibration coefficients and are found to be within 1.6%.

DSCOVR↗

Response Versus Scan-Angle Assessment of MODIS Reflective Solar Bands in Collection 6.1 Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard the Aqua and Terra satellites have been operated for nearly two decades, producing high-quality earth observation data sets suitable for a broad range of scientific studies regarding the earth’s land, ocean, and atmospheric processes. The high radiometric accuracy of MODIS reflective solar band (RSB) calibration has also served as benchmark measurements for on-orbit cross-calibration studies. As the two MODIS instruments have operated well beyond their design lifespan of six years, the measurements from the onboard calibrators alone become inadequate to characterize the sensor’s response at all scan angles, as evinced by long-term drifts observed at certain scan positions of the Aqua-MODIS 0.64- and 0.86-μm bands in Collection 6 (C6) data set. The latest MODIS Level 1B C6.1 data set incorporates earth-view response trending from invariant desert sites as supplemental inputs to characterize the scan-angle calibration dependencies for all RSB. This article presents a deep convective cloud (DCC)-based calibration approach for an independent evaluation of the MODIS RSB response versus scan-angle (RVS) performance in C6.1. The long-term calibration stability and RVS differences in C6.1 have been significantly improved for Aqua-MODIS RSB. The observed RVS differences of more than 2% in Aqua-MODIS C6 bands 1 and 2 have been reduced to within 1% in C6.1. Some RSBs of Terra-MODIS have suffered temporal drifts up to ~2% and calibration shifts up to 3%, particularly around 2016 when the Terra satellite entered into safe mode. The DCC approach has been found very effective in tracking the on-orbit RVS changes over time.

Clouds and the Earth’s Radiant Energy System (CERE↗

NOAA-20 VIIRS Reflective Solar bands on-Orbit Calibration Using a Hybrid Approach

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) has been in orbit for more than two and a half years. VIIRS has 22 bands, among which 14 are reflective solar bands (RSBs) covering a spectral range from 0.41 to 2.25 μm. The RSBs are calibrated on-orbit using an onboard solar diffuser (SD), on-orbit degradation of which is tracked by an onboard SD stability monitor (SDSM). NOAA-20 VIIRS is also scheduled to view the Moon approximately monthly and the lunar observations are used to track the RSB on-orbit changes as well. Both SD and lunar calibration results for the RSBs are shown and it is demonstrated that the two sets of the calibration coefficients diverge with time, especially at short wavelengths. The divergence is due to the non-uniformity of the SD degradation, which results in a long-term bias in the calibration coefficients derived from the SD calibration. A hybrid method, which properly combines the SD and lunar calibration results, is applied to generate the RSB calibration coefficients as has been done for SNPP VIIRS RSBs. The hybrid results have both the accuracy and frequency and ensure the high quality of the VIIRS sensor data records (SDR).

Calibration↗

SNPP VIIRS Day Night Band: Ten Years of On-Orbit Calibration and Performance

Aboard the polar-orbiting SNPP satellite, the VIIRS instrument has been in operation since launch in October 2011. It is a visible and infrared radiometer with a unique panchromatic channel capability designated as a day-night band (DNB). This channel covers wavelengths from 0.5 to 0.9 µm and is designed with a near-constant spatial resolution for Earth observations 24 h a day. The DNB operates at 3 gain stages (low, middle, and high) to cover a large dynamic range. An onboard solar diffuser (SD) is used for calibration in the low gain stage, and to enable the derivation of gain ratios between the different stages. In this paper, we present the SNPP VIIRS DNB calibration performed by the NASA VIIRS characterization support team (VCST). The DNB calibration algorithms are described to generate the calibration coefficient look up tables (LUTs) for the latest NASA Level 1B Collection 2 products. We provide an evaluation of DNB on-orbit calibration performance. This activity supports the NASA Earth science community by delivering consistent VIIRS sensor data products via the Land Science Investigator-led Processing Systems, including the SD degradation applied for DNB calibrations in detector gain and gain ratio trending. The DNB stray light contamination and its correction are highlighted. Performance validations are presented using comparisons to the calibration methods employed by NOAA’s operational Interface Data Processing Segment. Further work on stray light corrections is also discussed.

VIIRS↗