Subwavenumber charge-coupled device spectrometer calibration using molecular iodine laser-induced fluorescence

Spectrometers configured with charge-coupled devices (CCD) or other array-based detectors require calibration to convert from the pixel coordinate to a spectral coordinate. A CCD calibration method well suited for Raman spectroscopy has been developed based on the 514.5 nm Ar{sup +} laser-induced fluorescence (LIF) spectrum of room-temperature molecular iodine vapor. Over 360 primary and secondary I{sub 2} LIF calibration lines spanning 510-645 nm were identified as calibrant peaks using an instrumental resolution of 1 cm{sup -1}. Two instrument calibration functions were evaluated with these peaks: a second-order polynomial and a function derived from simple optomechanical considerations. The latter function provided better fitting characteristics. Calibration using I{sub 2} LIF was tested with measurements of both laser light scattering and Raman spectra. The I{sub 2} LIF reference spectra and the signal spectra were recorded simultaneously, with no cross talk, by separating the two signals spatially along the vertical axis of the CCD imager. In this way, every CCD image could be independently calibrated. An accuracy and a precision of {+-}0.05 cm{sup -1} were achieved with this calibration technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Piezoelectric Shaker Development for High Frequency Calibration of Accelerometers

Calibration of vibration transducers requires sinusoidal motion over a wide frequency range with low distortion and low cross-axial motion. Piezoelectric shakers are well suited to generate such motion and are suitable for use with laser interferometric methods at frequencies of 3 kHz and above. An advantage of piezoelectric shakers is the higher achievable accelerations and displacement amplitudes as compared to electro-dynamic (ED) shakers. Typical commercial ED calibration shakers produce maximum accelerations from 100 m/s{sup 2} to 500 m/s{sup 2}. Very large ED shakers may produce somewhat higher accelerations but require large amplifiers and expensive cooling systems to dissipate heat. Due to the limitations in maximum accelerations by ED shakers at frequencies above 5 kHz, the amplitudes of the generated sinusoidal displacement are frequently below the resolution of laser interferometers used in primary calibration methods. This limits the usefulness of ED shakers in interferometric based calibrations at higher frequencies.Small piezoelectric shakers provide much higher acceleration and displacement amplitudes for frequencies above 5 kHz, making these shakers very useful for accelerometer calibrations employing laser interferometric measurements, as will be shown in this paper. These piezoelectric shakers have been developed and used at NIST for many years for high frequency calibration of accelerometers. This paper documents the construction and performance of a new version of these shakers developed at NIST for the calibration of accelerometers over the range of 3 kHz to 30 kHz and possibly higher. Examples of typical calibration results are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dry calibration of electromagnetic flowmeters based on numerical models combining multiple physical phenomena (multiphysics)

This paper presents a method for dry calibration of an electromagnetic flowmeter (EMF). This method, which determines the voltage induced in the EMF as conductive liquid flows through a magnetic field, numerically solves a coupled set of multiphysical equations with measured boundary conditions for the magnetic, electric, and flow fields in the measuring pipe of the flowmeter. Specifically, this paper details the formulation of dry calibration and an efficient algorithm (that adaptively minimizes the number of measurements and requires only the normal component of the magnetic flux density as boundary conditions on the pipe surface to reconstruct the magnetic field involved) for computing the sensitivity of EMF. Along with an in-depth discussion on factors that could significantly affect the final precision of a dry calibrated EMF, the effects of flow disturbance on measuring errors have been experimentally studied by installing a baffle at the inflow port of the EMF. Results of the dry calibration on an actual EMF were compared against flow-rig calibration; excellent agreements (within 0.3%) between dry calibration and flow-rig tests verify the multiphysical computation of the fields and the robustness of the method. As requiring no actual flow, the dry calibration is particularly useful for calibrating large-diameter EMFs where conventional flow-rig methods are often costly and difficult to implement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards improved local hybrid functionals by calibration of exchange-energy densities

A new approach for the calibration of (semi-)local and exact exchange-energy densities in the context of local hybrid functionals is reported. The calibration functions are derived from only the electron density and its spatial derivatives, avoiding spatial derivatives of the exact-exchange energy density or other computationally unfavorable contributions. The calibration functions fulfill the seven more important out of nine known exact constraints. It is shown that calibration improves substantially the definition of a non-dynamical correlation energy term for generalized gradient approximation (GGA)-based local hybrids. Moreover, gauge artifacts in the potential-energy curves of noble-gas dimers may be corrected by calibration. The developed calibration functions are then evaluated for a large range of energy-related properties (atomization energies, reaction barriers, ionization potentials, electron affinities, and total atomic energies) of three sets of local hybrids, using a simple one-parameter local-mixing. The functionals are based on (a) local spin-density approximation (LSDA) or (b) Perdew-Burke-Ernzerhof (PBE) exchange and correlation, and on (c) Becke-88 (B88) exchange and Lee-Yang-Parr (LYP) correlation. While the uncalibrated GGA-based functionals usually provide very poor thermochemical data, calibration allows a dramatic improvement, accompanied by only a small deterioration of reaction barriers. In particular, an optimized BLYP-based local-hybrid functional has been found that is a substantial improvement over the underlying global hybrids, as well as over previously reported LSDA-based local hybrids. It is expected that the present calibration approach will pave the way towards new generations of more accurate hyper-GGA functionals based on a local mixing of exchange-energy densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of two-band infrared radiometer for irradiance calibration of target simulators

A detector-based spectral radiometer has been developed for the calibration of target simulator. Unlike the conventional spectral irradiance calibration method based on radiance and irradiance, the new radiometer is calibrated using image-space temperature based method. The image-space temperature based method improves the reproducibility in the calibration of radiometer and reduces the uncertainties existing in the conventional calibration methods. The calibrated radiometer is then used to establish the irradiance transfer standard for the target simulator. With the designed radiometer in this paper, a highly accurate irradiance calibration for target simulators of wavelength from 2.05 to 2.55 μm and from 3.7 to 4.8 μm can be performed with an expanded uncertainty (k = 2) of calibration of 2.18%. Last but not least, the infrared radiation of the target simulator was measured by the infrared radiometer, the effectiveness and capability of which are verified through measurement of temperature and irradiance and a comparison with the thermal imaging camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LONG-TERM CALIBRATION STABILITY OF A RADIO ASTRONOMICAL PHASED ARRAY FEED

There are many challenges associated with the implementation of a phased array feed for radio astronomy applications. Among these is the need to have an adequate set of calibration measurements so that reliable beamformers can be computed. Changes in the operating environment and temporal gain drift in the electronics contribute to calibration drift, which affects the beamformer performance. We will show that calibration measurements are relatively stable over a 5 day period and may remain so for up to 70 days or longer. We have incorporated the use of a calibration update system that has the potential to refresh a set of old calibrators, specifically correcting for electronic gain drift. However, the long-term variations that are present with fresh, current calibrators are greater than the degradation due to using an old calibration set, suggesting that, at this time, there is not a need for sophisticated calibration update systems or algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

IMPACT OF CHANDRA CALIBRATION UNCERTAINTIES ON GALAXY CLUSTER TEMPERATURES: APPLICATION TO THE HUBBLE CONSTANT

We perform a uniform, systematic X-ray spectroscopic analysis of a sample of 38 galaxy clusters with three different Chandra calibrations. The temperatures change systematically between calibrations. Cluster temperatures change on average by roughly {approx}6% for the smallest changes and roughly {approx}13% for the more extreme changes between calibrations. We explore the effects of the Chandra calibration on cluster spectral properties and the implications on Sunyaev-Zel'dovich effect (SZE) and X-ray determinations of the Hubble constant. The Hubble parameter changes by +10% and -13% between the current calibration and two previous Chandra calibrations, indicating that changes in the cluster temperature basically explain the entire change in H{sub 0}. Although this work focuses on the difference in spectral properties and resultant Hubble parameters between the calibrations, it is intriguing to note that the newer calibrations favor a lower value of the Hubble constant, H{sub 0} {approx} 60 km s{sup -1} Mpc{sup -1}, typical of results from SZE/X-ray distances. Both galaxy clusters themselves and the details of the instruments must be known precisely to enable reliable precision cosmology with clusters, which will be feasible with combined efforts from ongoing observations and planned missions and observatories covering a wide range of wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗

UNDERFLIGHT CALIBRATION OF SOHO/CDS AND HINODE/EIS WITH EUNIS-07

Flights of Goddard Space Flight Center's Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS) sounding rocket in 2006 and 2007 provided updated radiometric calibrations for Solar and Heliospheric Observatory/Coronal Diagnostic Spectrometer (SOHO/CDS) and Hinode/Extreme Ultraviolet Imaging Spectrometer (Hinode/EIS). EUNIS carried two independent imaging spectrographs covering wavebands of 300-370 A in first order and 170-205 A in second order. After each flight, end-to-end radiometric calibrations of the rocket payload were carried out in the same facility used for pre-launch calibrations of CDS and EIS. During the 2007 flight, EUNIS, SOHO/CDS, and Hinode/EIS observed the same solar locations, allowing the EUNIS calibrations to be directly applied to both CDS and EIS. The measured CDS NIS 1 line intensities calibrated with the standard (version 4) responsivities with the standard long-term corrections are found to be too low by a factor of 1.5 due to the decrease in responsivity. The EIS calibration update is performed in two ways. One uses the direct calibration transfer of the calibrated EUNIS-07 short wavelength (SW) channel. The other uses the insensitive line pairs, in which one member was observed by the EUNIS-07 long wavelength (LW) channel and the other by EIS in either the LW or SW waveband. Measurements from both methods are in good agreement, and confirm (within the measurement uncertainties) the EIS responsivity measured directly before the instrument's launch. The measurements also suggest that the EIS responsivity decreased by a factor of about 1.2 after the first year of operation (although the size of the measurement uncertainties is comparable to this decrease). The shape of the EIS SW response curve obtained by EUNIS-07 is consistent with the one measured in laboratory prior to launch. The absolute value of the quiet-Sun He II 304 A intensity measured by EUNIS-07 is consistent with the radiance measured by CDS NIS in quiet regions near the disk center and the solar minimum irradiance recently obtained by CDS NIS and the Solar Dynamics Observatory/Extreme Ultraviolet Variability Experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What we propose here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA made miniature fission chambers in Campbelling mode is studied. We use a theoretical model of the signal to calculate the calibration coefficient. Input parameters of the model come from statistical distribution of individual pulses. Supporting measurements have been made in the CEA Cadarache zero power reactor MINERVE and results are compared to an empirical Campbelling mode calibration. The tested fission chamber calibration coefficient is about 2 10{sup -26} A{sup 2}/Hz/(c/s). Both numerical and empirical methods give consistent results, however a deviation of about 15 % was observed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What is proposed here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA-made miniature fission chambers in Campbelling mode is studied. A theoretical model of the signal is used to calculate the calibration coefficient. The model's input parameters come from statistical distribution of individual pulses. Supporting measurements were made in the CEA Cadarache zero power reactor MINERVE and results are compared to an empirical Campbelling mode calibration. The tested fission chamber calibration coefficient is roughly 2*10{sup -26} A{sup 2}/Hz/(c/s). Both numerical and empirical methods give consistent results, however a deviation of about 15% was observed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calibration of the Gamma Knife using a new phantom following the AAPM TG51 and TG21 protocols

Purpose: To compare calibration of the Leksell Gamma Knife according to the American Association of Physicists in Medicine Task Groups 21 and 51 protocols. A new phantom was fabricated for this purpose. Its design, physical properties, and composition are described. Materials and methods: The Gamma Knife TG-51 calibration phantom is designed to be filled with water and support an ionization chamber positioned at its center. The phantom is thimble-shaped, with a 2 mm plastic wall to contain water. The phantom and chamber assembly was mounted in a LeksellTM stereotactic frame. The location of the chamber's sensitive volume was determined using computed tomography. The chamber-phantom assembly was attached to the 18 mm helmet in the Gamma Knife by the stereotactic frame. The phantom's geometry allowed radiation beams from each of the 201 Gamma Knife cobalt-60 sources to converge after an 8 cm path to the ionization chamber's sensitive volume. This is similar to the arrangement by which one calibrates the Gamma Knife using the manufacturer-supplied polystyrene phantom. Results: The phantom was attached to the Gamma Knife so that the ionization chamber was reproducibly positioned at the convergence of the radiation beams. Because of the phantom's design, the phantom could be affixed to either trunnions or the automatic patient positioning system, once mounted in the LeksellTM stereotectic frame. Comparisons using different phantoms and protocols resulted in the following calibration ratios for TG-21 in the polystyrene sphere phantom, TG-21 in the water phantom, and TG-51 in the water phantom, respectively: 1.000, 1.008, 0.986, when corrected for transmission through the plastic water reservoir wall and using the same ionization chamber. Transmission measurements using a 1 cm thickness of the same material in the Co-60 beam determined that the phantom's 2 mm plastic wall resulted in a reduction in the measured the output by 0.5%. Conclusions: Calibration of the Gamma Knife can be performed in liquid water using the AAPM TG-51 protocol and this new phantom, thereby eliminating uncertainties with respect to the composition of the manufacturer's phantom. Perturbation of calibration measurements by nonwater materials was characterized and could be corrected. Calibration values for the Gamma Knife that were obtained using the three methods for our phantoms agree to within 1.4%. TG21 and TG51 calibration of the Gamma Knife using the water phantom agreed to within 2.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Air kerma standard for calibration of well-type chambers in Brazil using {sup 192}Ir HDR sources and its traceability

In Brazil there are over 100 high dose rate (HDR) brachytherapy facilities using well-type chambers for the determination of the air kerma rate of {sup 192}Ir sources. This paper presents the methodology developed and extensively tested by the Laboratorio de Ciencias Radiologicas (LCR) and presently in use to calibrate those types of chambers. The system was initially used to calibrate six well-type chambers of brachytherapy services, and the maximum deviation of only 1.0% was observed between the calibration coefficients obtained and the ones in the calibration certificate provided by the UWADCL. In addition to its traceability to the Brazilian National Standards, the whole system was taken to University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) for a direct comparison and the same formalism to calculate the air kerma was used. The comparison results between the two laboratories show an agreement of 0.9% for the calibration coefficients. Three Brazilian well-type chambers were calibrated at the UWADCL, and by LCR, in Brazil, using the developed system and a clinical HDR machine. The results of the calibration of three well chambers have shown an agreement better than 1.0%. Uncertainty analyses involving the measurements made both at the UWADCL and LCR laboratories are discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems

Purpose: To study the sensitivity of a geometric calibration method using projection matrices for digital tomosynthesis systems. Methods: A generic geometric calibration method for tomographic imaging systems has been presented in our previous work. The method involves a scan of a calibration phantom with multiple markers. Their locations in projection images are detected and are associated with their 3D coordinates to compute 3x4 projection matrices, which can be used in subsequent image reconstruction. The accuracy of geometric calibration may be affected by errors in the input data of marker positions. The effects of errors may depend on the number of markers and the volume surrounded by them in 3D space. This work analyzed the sensitivity of the calibration method to the above factors. A 6 cm CIRS breast research phantom and a prototype breast tomosynthesis system were used for our tests. A high contrast ring and two small speck groups were reconstructed in various testing cases for comparison. To achieve quantitative assessment, a 15x15 point detection mask was adopted for detecting signals and for computing changes between testing cases and the regular geometric calibration. Results: When 3D coordinates and 2D projections of markers were accurate, all tested numbers of markers, 6-44, provided similar high quality reconstructions of the ring and the two speck groups. Errors in marker positions resulted in image degradations and signal changes, which increased with fewer markers and smaller volume surrounded by markers in the 3D object space. Signal changes of small specks were more significant than those of the ring. Errors in marker projections produced drastic image degradations. Coplanar marker placement caused a failure in projection matrix computation. Conclusions: For practical geometric calibration phantom design, ample markers are desired. They need to have a large volumetric coverage in the 3D space and be far from being coplanar. Precise determination of marker projections on detector planes is crucial for accurate geometric calibration and for small object detection using the reconstructed images.

60 APPLIED LIFE SCIENCES↗

Automated intraoperative calibration for prostate cancer brachytherapy

Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 {+-} 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 {+-} 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 {+-} 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 {+-} 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Humidity effects on calibrations of radiation therapy electrometers

Purpose: To eliminate variation in electrometer calibration results caused by high humidity and suboptimal connectors on the standard capacitors and to implement hardware that prevents overloading of the input stage of electrometers during calibration. Methods: A humidity-controlled cabinet was installed to provide a low-humidity environment for the standard capacitors. All of the coaxial BNC connections were replaced with Triax (TRB) connectors with the exception of the output from the voltage source. A three-stage RC filter with cascaded RC low-pass sections was designed and tested. Results: The installation of the humidity cabinet resulted in a major improvement in the stability and reproducibility of the electrometer calibration system. For the three years since this upgrade, the Ionizing Radiation Standards (IRS) electrometer calibration results have been consistent regardless of the ambient relative humidity in the lab. The connector replacements improved grounding in the calibration circuit. The three-stage filter allows the voltage at the output to rise in an S-shaped waveform, resulting in a smooth rise of the current through the isolation resistor from zero and back again, with no abrupt transition. For the filter design chosen, 99.99% of the charge is delivered within 6 s. Conclusions: A three-way improvement to the calibration measurement system was successful in eliminating the observed variations, resulting in an electrometer calibration measurement system that is unaffected by humidity and allowing reliable year-round calibrations of any electrometer encountered since the implementation of these changes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water-equivalent path length calibration of a prototype proton CT scanner

Purpose: The authors present a calibration method for a prototype proton computed tomography (pCT) scanner. The accuracy of these measurements depends upon careful calibration of the energy detector used to measure the residual energy of the protons that passed through the object. Methods: A prototype pCT scanner with a cesium iodide (CsI(Tl)) crystal calorimeter was calibrated by measuring the calorimeter response for protons of 200 and 100 MeV initial energies undergoing degradation in polystyrene plates of known thickness and relative stopping power (RSP) with respect to water. Calibration curves for the two proton energies were obtained by fitting a second-degree polynomial to the water-equivalent path length versus calorimeter response data. Using the 100 MeV calibration curve, the RSP values for a variety of tissue-equivalent materials were measured and compared to values obtained from a standard depth-dose range shift measurement using a water-tank. A cylindrical water phantom was scanned with 200 MeV protons and its RSP distribution was reconstructed using the 200 MeV calibration. Results: It is shown that this calibration method produces measured RSP values of various tissue-equivalent materials that agree to within 0.5% of values obtained using an established water-tank method. The mean RSP value of the water phantom reconstruction was found to be 0.995 {+-} 0.006. Conclusions: The method presented provides a simple and reliable procedure for calibration of a pCT scanner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-470: Importance of HU-Mass Density Calibration Technique in Proton Pencil Beam Dose Calculation

Purpose: Stoichiometric calibration of Hounsfield Units (HUs) for conversion to proton relative stopping powers (RStPs) is vital for accurate dose calculation in proton therapy. However proton dose distributions are not only dependent on RStP, but also on relative scattering power (RScP) of patient tissues. RScP is approximated from material density but a stoichiometric calibration of HU-density tables is commonly neglected. The purpose of this work was to quantify the difference in calculated dose of a commercial TPS when using HU-density tables based on tissue substitute materials and stoichiometric calibrated ICRU tissues. Methods: Two HU-density calibration tables were generated based on scans of the CIRS electron density phantom. The first table was based directly on measured HU and manufacturer quoted density of tissue substitute materials. The second was based on the same CT scan of the CIRS phantom followed by a stoichiometric calibration of ICRU44 tissue materials. The research version of Pinnacle{sup 3} proton therapy was used to compute dose in a patient CT data set utilizing both HU-density tables. Results: The two HU-density tables showed significant differences for bone tissues; the difference increasing with increasing HU. Differences in density calibration table translated to a difference in calculated RScP of −2.5% for ICRU skeletal muscle and 9.2% for ICRU femur. Dose-volume histogram analysis of a parallel opposed proton therapy prostate plan showed that the difference in calculated dose was negligible when using the two different HU-density calibration tables. Conclusion: The impact of HU-density calibration technique on proton therapy dose calculation was assessed. While differences were found in the calculated RScP of bony tissues, the difference in dose distribution for realistic treatment scenarios was found to be insignificant.

60 APPLIED LIFE SCIENCES↗

A new form of the calibration curve in radiochromic dosimetry. Properties and results

Purpose: This work describes a new form of the calibration curve for radiochromic dosimetry that depends on one fit parameter. Some results are reported to show that the new curve performs as well as those previously used and, more importantly, significantly reduces the dependence on the lot of films, the film orientation on the scanner, and the time after exposure. Methods: The form of the response curve makes use of the net optical densities ratio against the dose and has been studied by means of the Beer–Lambert law and a simple modeling of the film. The new calibration curve has been applied to EBT3 films exposed at 6 and 15 MV energy beams of linear accelerators and read-out in transmission mode by means of a flatbed color scanner. Its performance has been compared to that of two established forms of the calibration curve, which use the optical density and the net optical density against the dose. Four series of measurements with four lots of EBT3 films were used to evaluate the precision, accuracy, and dependence on the time after exposure, orientation on the scanner and lot of films. Results: The new calibration curve is roughly subject to the same dose uncertainty, about 2% (1 standard deviation), and has the same accuracy, about 1.5% (dose values between 50 and 450 cGy), as the other calibration curves when films of the same lot are used. Moreover, the new calibration curve, albeit obtained from only one lot of film, shows a good agreement with experimental data from all other lots of EBT3 films used, with an accuracy of about 2% and a relative dose precision of 2.4% (1 standard deviation). The agreement also holds for changes of the film orientation and of the time after exposure. Conclusions: The dose accuracy of this new form of the calibration curve is always equal to or better than those obtained from the two types of curves previously used. The use of the net optical densities ratio considerably reduces the dependence on the lot of films, the landscape/portrait orientation, and the time after exposure. This form of the calibration curve could become even more useful with new optical digital devices using monochromatic light.

60 APPLIED LIFE SCIENCES↗