Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

A vibration technique his been developed to continuously maintain mode resonance and impedance much between a constant frequency magnetron source and resonant cavity. This method uses a vibrating metal rod to modulate the volume of the cavity in a manner equivalent to modulating an adjustable plunger. A similar vibrating metal rod attached to a stub tuner modulates the waveguide volume between the source and cavity. A phase sensitive detection scheme determines the optimum position of the adjustable plunger and stub turner during processing. The improved power transfer during the heating of a 99.8% pure alumina rod was demonstrated using this new technique. Temperature-time and reflected power-time heating curves are presented for the cases of no tracking, impedance tracker only, mode tracker only and simultaneous impedance and mode tracking. Controlled internal melting of an alumina rod near 2000 C using both tracking units was also demonstrated.

Barmatz, M.↗

Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

There has been a concerted effort to improve the microwave heating technique for processing materials at high temperature. Improved optimization of the energy transfer from a microwave source to the material being processed is required. A vibration technique is pre- sented to continuously maintain a mode resonance and impedance match between a constant frequency magnetron source and a resonant cavity.

microwave↗

Resonant flow in small cavities submerged in a boundary layer

Experiments were performed to determine the conditions under which a narrow-frequency-band flow excitement could be sustained in a row of small transverse square cavities while the boundary layer in which they were submerged was already turbulent. This is shown to happen when the depth of the Stokes layer generated by monochromatic freestream disturbances is nearly the same as the cavity depth. This indicates that viscous waves can exist in thin layers adjacent to the surface under a turbulent boundary layer.

Bandyopadhyay, P. R.↗

An experimental investigation of flow-induced oscillations of the Bruel and Kjaer in-flow microphone

One source contributing to wind tunnel background noise is microphone self-noise. An experiment was conducted to investigate the flow-induced acoustic oscillations of Bruel & Kjaer (B&K) in-flow microphones. The results strongly suggest the B&K microphone cavity behaves more like an open cavity. Their cavity acoustic oscillations are likely caused by strong interactions between the cavity shear layer and the cavity trailing edge. But the results also suggest that cavity shear layer oscillations could be coupled with cavity acoustic resonance to generate tones. Detailed flow velocity measurements over the cavity screen have shown inflection points in the mean velocity profiles and high disturbance and spectral intensities in the vicinity of the cavity trailing edge. These results are the evidence for strong interactions between cavity shear layer oscillations and the cavity trailing edge. They also suggest that beside acoustic signals, the microphone inside the cavity has likely recorded hydrodynamic pressure oscillations, too. The results also suggest that the forebody shape does not have a direct effect on cavity oscillations. For the FITE (Flow Induced Tone Eliminator) microphone, it is probably the forebody length and the resulting boundary layer turbulence that have made it work. Turbulence might have thickened the boundary layer at the separation point, weakened the shear layer vortices, or lifted them to miss impinging on the cavity trailing edge. In addition, the study shows that the cavity screen can modulate the oscillation frequency but not the cavity acoustic oscillation mechanisms.

Fields, Richard S., Jr.↗

Low-noise fan exit guide vanes

Low-noise fan exit guide vanes are disclosed. According to the present invention a fan exit guide vane has an outer shell substantially shaped as an airfoil and defining an interior cavity. A porous portion of the outer shell allows communication between the fluctuations in the air passing over the guide vane and the interior cavity. At least one acoustically resonant chamber is located within the interior cavity. The resonant chamber is in communication with the porous portion of the outer perimeter. The resonant chamber is configured to reduce the noise generated at a predetermined frequency. In various preferred embodiments, there is a plurality of acoustically resonant chambers located within the interior cavity. The resonant chambers can be separated by one or more partitions within the interior cavity. In these embodiments, the resonant chambers can be configured to reduce the noise generated over a range of predetermined frequencies.

Jones, Michael G.↗

Scaling studies of blackbody pumped lasers

The scaling of blackbody pumped lasers to large powers is being studied. The computational results show the possibility of high pressure transverse flow blackbody pumped lasers. A nonsteady technique with metal shims heated rapidly to 1500 K as the blackbody pumping source is being used to carry out the experiment. Fast temperature rise of the shims creates pressure waves inside the laser cavity which destroy the resonance of the cavity. A new design with rectangular quartz tubing inside the cavity to prevent the waves from reaching the lasing region is under construction.

Chang, Jim↗

Features Of Cavity Flow And Acoustics Of Stratospheric Observatory For Infrared Astronomy

The stratospheric observatory for infrared astronomy (SOFIA) is a 2.5 meter aperture Cassegrain telescope with a Nasmyth focus that will be housed in an open cavity in the Boeing 747-SP aircraft and operated at altitudes around 41,000 feet for infrared (IR) viewing of celestial events of astronomical nature. At these altitudes the IR viewing capability of SOFIA far exceeds that of any ground based system. To minimize IR transmission losses, SOFIA will operate with an open cavity. Such an open cavity during flight creates several challenging aerodynamic and aeroacoustic design problems. Foremost of these are: the shear layer over the cavity may cause unwanted resonance if the cavity is untreated; this might give rise to excessive sound pressure levels (SPL) in the cavity and thus affect the unsteady loads on the telescope; the unsteady flow within the cavity produces large dynamic loads and moments that will impact the pointing accuracy of the telescope; the open cavity and the shear layer control devices produce additional drag that will affect directly the time of flight of the mission; the aft location of the cavity down stream of port wing will affect the the flow on the aircraft control surfaces and thus the stability of the aircraft. Also, the highly turbulent shear layer over the cavity and the temperature gradients and 'hot spots' within the cavity can produce a wave front error of the image when it reaches the focal plane of the recorder.

Srinivasan, G. R.↗

A numerical study of active structural acoustic control in a stiffened, double wall cylinder

It is demonstrated that active structural acoustic control of complex structural/acoustic coupling can be numerically modeled using finite element and boundary element techniques in conjunction with an optimization procedure to calculate control force amplitudes. Appreciable noise reduction is obtained when the structure is excited at a structural resonance of the outer shell or an acoustic resonance of the inner cavity. Adding ring stiffeners as a connection between the inner and outer shells provides an additional structural transmission path to the interior cavity and coupled the modal behavior of the inner and outer shells. For the case of excitation at the structural resonance of the unstiffened outer shell, adding the stiffeners raises the structural resonance frequencies. The effectiveness of the control forces is reduced due to the off resonance structural response. For excitation at an acoustic cavity resonance, the controller effectiveness is enhanced.

Grosveld, Ferdinand W.↗

Highly Stable Microwave Resonator

Superconducting walls on sapphire-filled cavity make low-loss device. Improved microwave resonant cavity consists of sapphire cylinder coated with thin film of superconducting lead. Operated well below superconducting transition temperature at 1.5K, cavity demonstrated superior frequency stability and quality factor. Cavity frequency highly stable and therefore suitable for use in standard frequency generators and filters.

Strayer, Donald M.↗

Spatial electron density and electric field strength measurements in microwave cavity experiments

Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub 3 calculated from measured plasma conductivity. Additional measurements of n sub 3 as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

Peters, M.↗

Spatial electron density and electric field strength measurements in microwave cavity experiments

Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub e calculated from measured plasma conductivity. Additional measurements of n sub e as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

Peters, M.↗

Cavity-Modulation Autotuner For Hydrogen Maser

Cavity-modulation tuning system maintains resonance of hydrogen-maser cavity automatically, stabilizing maser frequency, without introducing undesirable frequency modulation. System tunes maser cavity rapidly by modulating one of physical characteristics of cavity affecting resonant frequency. Frequency-controlling components of tuning system placed at maser cavity, within maser vacuum. Thermal environment well controlled, and device insensitive to driving signal. Features contribute to stability of maser frequency.

Dick, G. J.↗

More About Graded-Reflectance Optics For Coherent Lidar

Report presents theoretical study of energy-extraction and power-transmission efficiency of unstable-resonator laser cavity, output mirror of which has graded reflectance. Super-gaussian reflectance profile may optimize performance. Similar study reported in "Comparative Study of Resonator Optics for Lidar Applications" (NPO-17776).

Tratt, David M.↗