Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coherent diffraction imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Electric field driven domain wall dynamics in BaTiO 3 nanoparticles

We report a detailed investigation into the response of single BaTiO 3 (BTO) nanocrystals under applied electric fields (E-field) using Bragg coherent diffraction imaging. Our study reveals pronounced domain wall migration and expansion of a sample measure under applied electric field. The changes are most prominent at the surface of the nanocrystal, where the lack of external strain allows greater domain wall mobility. The observed domain shifts are correlated to the strength and orientation of the applied E-field, following a side-by-side domain model from Suzana []. Notably, we identified a critical electric field strength of 3 MV/m, which leads to irreversible structural changes, suggesting plastic deformation. The findings highlight how surface effects and intrinsic defects contribute to the enhanced dielectric properties of BTO at the nanoscale, in contrast to bulk materials, where strain limits domain mobility. These findings deepen our understanding of nanoscale dielectric behavior and inform the design of advanced nanoelectronic devices. Published by the American Physical Society 2025

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shapes of rotating superfluid helium nanodroplets

Rotating superfluid He droplets of approximately 1 μm in diameter were obtained in a free nozzle beam expansion of liquid He in vacuum and were studied by single-shot coherent diffractive imaging using an x-ray free electron laser. The formation of strongly deformed droplets is evidenced by large anisotropies and intensity anomalies (streaks) in the obtained diffraction images. The analysis of the images shows that in addition to previously described axially symmetric oblate shapes, some droplets exhibit prolate shapes. Forward modeling of the diffraction images indicates that the shapes of rotating superfluid droplets are very similar to their classical counterparts, giving direct access to the droplet angular momenta and angular velocities. Here, the analyses of the radial intensity distribution and appearance statistics of the anisotropic images confirm the existence of oblate metastable superfluid droplets with large angular momenta beyond the classical bifurcation threshold.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Behavior of strain stripe networks in barium titanate nanocrystals on crossing its ferroelectric phase transition

Nanoscale strain networks are reported in BaTi O 3 (BTO) crystals of 300 nm size using Bragg coherent diffractive imaging. BTO nanocrystals with clear facets were chosen to identify the crystallographic directions, allowing the strain field direction and periodicity to be studied in detail. Stripes of strain were observed, which were both stable and preserved in tetragonal and cubic phases at elevated temperatures, above the tetragonal-to-cubic phase transition. A finite element analysis approach was used to simulate the domain structures inside a BTO crystal and to understand the origins of the strain stripes as piezoelectric blocks. A 180 ∘ domain model gives a better qualitative match to the experimental images. Published by the American Physical Society 2024

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Domain morphology, boundaries, and topological defects in biophotonic gyroid nanostructures of butterfly wing scales

Many organisms in nature have evolved sophisticated cellular mechanisms to produce photonic nanostructures and, in recent years, diverse crystalline symmetries have been identified and related to macroscopic optical properties. However, because we know little about the distributions of domain sizes, the orientations of photonic crystals, and the nature of defects in these structures, we are unable to make the connection between the nanostructure and its development and functionality. We report on nondestructive studies of the morphology of chitinous photonic crystals in butterfly wing scales. Using spatially and angularly resolved x-ray diffraction, we find that the domains are highly oriented with respect to the whole scale, indicating growth from scale boundaries. X-ray coherent diffractive imaging reveals two types of crystalline domain interfaces: abrupt changes between domains emerging from distinct nucleation sites and smooth transitions with edge dislocations presumably resulting from internal stresses during nanostructure development. Our study of the scale structure reveals new aspects of photonic crystal growth in butterfly wings and shows their similarity to block copolymer materials. It opens new avenues to exploration of fundamental processes underlying the growth of biological photonic nanostructures in a variety of species.

36 MATERIALS SCIENCE↗

Shapes and vorticities of superfluid helium nanodroplets

Helium nanodroplets are considered ideal model systems to explore quantum hydrodynamics in self-contained, isolated superfluids. However, exploring the dynamic properties of individual droplets is experimentally challenging. In this work, we used single-shot femtosecond x-ray coherent diffractive imaging to investigate the rotation of single, isolated superfluid helium-4 droplets containing ∼10 8 to 10 11 atoms. The formation of quantum vortex lattices inside the droplets is confirmed by observing characteristic Bragg patterns from xenon clusters trapped in the vortex cores. The vortex densities are up to five orders of magnitude larger than those observed in bulk liquid helium. The droplets exhibit large centrifugal deformations but retain axially symmetric shapes at angular velocities well beyond the stability range of viscous classical droplets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Physical optics simulations for synchrotron radiation sources

Here we describe approaches to high-accuracy physical optics calculations used for the development of x-ray beamlines at synchrotron radiation sources, as well as simulation of experiments and processing of experimental data at some of these beamlines. We pay special attention to the treatment of the partial coherence of x rays, a topic of high practical importance for modern low-emittance high-brightness synchrotron radiation facilities. The approaches are based, to a large extent, on the works of Emil Wolf and co-authors, including the basic scalar diffraction theory and the coherent mode decomposition method. The presented simulation examples are related to the case of the novel Coherent Diffractive Imaging beamline that is currently under development at the National Synchrotron Light Source II at the Brookhaven National Laboratory.

36 MATERIALS SCIENCE↗

Accurate determination of segmented X-ray detector geometry

Recent advances in X-ray detector technology have resulted in the introduction of segmented detectors composed of many small detector modules tiled together to cover a large detection area. Due to mechanical tolerances and the desire to be able to change the module layout to suit the needs of different experiments, the pixels on each module might not align perfectly on a regular grid. Several detectors are designed to permit detector sub-regions (or modules) to be moved relative to each other for different experiments. Accurate determination of the location of detector elements relative to the beam-sample interaction point is critical for many types of experiment, including X-ray crystallography, coherent diffractive imaging (CDI), small angle X-ray scattering (SAXS) and spectroscopy. For detectors with moveable modules, the relative positions of pixels are no longer fixed, necessitating the development of a simple procedure to calibrate detector geometry after reconfiguration. We describe a simple and robust method for determining the geometry of segmented X-ray detectors using measurements obtained by serial crystallography. By comparing the location of observed Bragg peaks to the spot locations predicted from the crystal indexing procedure, the position, rotation and distance of each module relative to the interaction region can be refined. Furthermore, we show that the refined detector geometry greatly improves the results of experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PtychoNet: Fast and High Quality Phase Retrieval for Ptychography

Ptychography is a coherent diffractive imaging method that captures multiple diffraction patterns of a sample with a set of shifted localized illuminations (“probes”). The reconstruction problem, known as “phase retrieval”, is typically solved by iterative algorithms. In this paper, we propose PtychoNet, a deep learning based method to perform phase retrieval for ptychography in a non-iterative manner. We devise a generative network to encode a full ptychography scan, reverse the diffractions at each scanning point and compute the amplitude and phase of the object. We demonstrate successful reconstructions using PtychoNet as well as recovering fine features in the case of extreme sparse scanning where conventional iterative methods fail to give recognizable features.

97 MATHEMATICS AND COMPUTING↗

Physical Sciences Vistas, Issue 1 2021 [Newsletter]

Issue 1 highlights of the Los Alamos Physical Sciences Vistas newsletter include: Finding and aiding success through the Lab's employee scholarship fund; Volunteer vignettes: helping others throughout Northern New Mexico; X-ray topography instrument reimagined for use at Oregon State University; Potentially activated metal recycle project triples its goal; Adaptive 3D machine-learning method for 3D coherent diffraction imaging; and, Sigma team aims for excellence in safety, quality, productivity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rethinking Coherent Diffraction Instruments for High Brightness Sources

Over the past two decades, exceptional progress has been made providing coherent x-ray beams at both high-brightness synchrotron sources and x-ray free electron lasers (XFEL). The availability of these coherent x-rays has led to a surge in instruments that exploit x-ray coherence for either x-ray photon correlation spectroscopy (XPCS) or coherent diffraction imaging (CDI). A key to these techniques has been to resolve, or at least nearly resolve, the speckles associated with the scattering from structural disorder. Given practical limits on detector pixel size, this requires long sample-to-detector distances. This paper presents numerical simulations of an instrument that can efMiciently provide a long sample-detector distance while maintaining the ability to rapidly set momentum transfer by inserting crystals with different order in the incident beam, thus changing in incident direction instead of moving the detector.

Fuoss, Paul H↗

Coherent hard x-ray diffractive imaging of nonisolated objects confined by an aperture

Coherent hard x-ray imaging of nonisolated weak phase objects is demonstrated by confining x-ray beam in a region of a few micrometers in cross section using a micrometer-sized aperture. Two major obstacles in the hard x-ray coherent diffraction imaging, isolating samples and obtaining central speckles, are addressed by using the aperture. The usefulness of the proposed method is illustrated by reconstructing the exit wave field of a nanoscale trench structure fabricated on silicon which serves as a weak phase object. The quantitative phase information of the exit wave field was used to reconstruct the depth profile of the trench structure. The scanning capability of this method was also briefly discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent diffraction microscopy at SPring-8: instrumentation, data acquisition and data analysis

Since the first demonstration of coherent diffraction microscopy in 1999, this lensless imaging technique has been experimentally refined by continued developments. Here, instrumentation and experimental procedures for measuring oversampled diffraction patterns from non-crystalline specimens using an undulator beamline (BL29XUL) at SPring-8 are presented. In addition, detailed post-experimental data analysis is provided that yields high-quality image reconstructions. As the acquisition of high-quality diffraction patterns is at least as important as the phase-retrieval procedure to guarantee successful image reconstructions, this work will be of interest for those who want to apply this imaging technique to materials science and biological samples.

oversampling↗

Concurrent multi-peak Bragg coherent x-ray diffraction imaging of 3D nanocrystal lattice displacement via global optimization

Abstract In this paper we demonstrated a method to reconstruct vector-valued lattice distortion fields within nanoscale crystals by optimization of a forward model of multi-reflection Bragg coherent diffraction imaging (MR-BCDI) data. The method flexibly accounts for geometric factors that arise when making BCDI measurements, is amenable to efficient inversion with modern optimization toolkits, and allows for globally constraining a single image reconstruction to multiple Bragg peak measurements. This is enabled by a forward model that emulates the multiple Bragg peaks of a MR-BCDI experiment from a single estimate of the 3D crystal sample. We present this forward model, we implement it within the stochastic gradient descent optimization framework, and we demonstrate it with simulated and experimental data of nanocrystals with inhomogeneous internal lattice displacement. We find that utilizing a global optimization approach to MR-BCDI affords a reliable path to convergence of data which is otherwise challenging to reconstruct.

36 MATERIALS SCIENCE↗

Coherent X-ray diffraction imaging and characterization of strain in silicon-on-insulator nanostructures

Coherent X-ray diffraction imaging (CDI) has emerged in the last decade as a promising high resolution lens-less imaging approach for the characterization of various samples. It has made significant technical progress through developments in source, algorithm and imaging methodologies thus enabling important scientific breakthroughs in a broad range of disciplines. In this report, we will introduce the principles of forward scattering CDI and Bragg geometry CDI (BCDI), with an emphasis on the latter. BCDI exploits the ultra-high sensitivity of the diffraction pattern to the distortions of crystalline lattice. Its ability of imaging strain on the nanometer scale in three dimensions is highly novel. We will present the latest progress on the application of BCDI in investigating the strain relaxation behavior in nanoscale patterned strained silicon-on-insulator (sSOI) materials, aiming to understand and engineer strain for the design and implementation of new generation semiconductor devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Simultaneous Multi-Bragg Peak Coherent X-ray Diffraction Imaging

The simultaneous measurement of two Bragg reflections by Bragg coherent X-ray diffraction is demonstrated on a twinned Au crystal, which was prepared by the solid-state dewetting of a 30 nm thin gold film on a sapphire substrate. The crystal was oriented on a goniometer so that two lattice planes fulfill the Bragg condition at the same time. The Au 111 and Au 200 Bragg peaks were measured simultaneously by scanning the energy of the incident X-ray beam and recording the diffraction patterns with two two-dimensional detectors. While the former Bragg reflection is not sensitive to the twin boundary, which is oriented parallel to the crystal–substrate interface, the latter reflection is only sensitive to one part of the crystal. The volume ratio between the two parts of the twinned crystal is about 1:9, which is also confirmed by Laue microdiffraction of the same crystal. The parallel measurement of multiple Bragg reflections is essential for future in situ and operando studies, which are so far limited to either a single Bragg reflection or several in series, to facilitate the precise monitoring of both the strain field and defects during the application of external stimuli.

47 OTHER INSTRUMENTATION↗

Three-dimensional coherent X-ray diffraction imaging via deep convolutional neural networks

Abstract As a critical component of coherent X-ray diffraction imaging (CDI), phase retrieval has been extensively applied in X-ray structural science to recover the 3D morphological information inside measured particles. Despite meeting all the oversampling requirements of Sayre and Shannon, current phase retrieval approaches still have trouble achieving a unique inversion of experimental data in the presence of noise. Here, we propose to overcome this limitation by incorporating a 3D Machine Learning (ML) model combining (optional) supervised learning with transfer learning. The trained ML model can rapidly provide an immediate result with high accuracy which could benefit real-time experiments, and the predicted result can be further refined with transfer learning. More significantly, the proposed ML model can be used without any prior training to learn the missing phases of an image based on minimization of an appropriate ‘loss function’ alone. We demonstrate significantly improved performance with experimental Bragg CDI data over traditional iterative phase retrieval algorithms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent x-ray diffraction imaging of paint pigmentparticles by scanning a phase plate modulator

We have implemented a coherent x-ray diffraction imaging technique that scans a phase plate to modulate wave-fronts of the x-ray beam transmitted by samples. The method was applied to measure a decorative alkyd paint containing iron oxide red pigment particles. By employing an iterative algorithm for wave-front modulation phase retrieval, we obtained an image of the paint sample that shows the distribution of the pigment particles and is consistent with the result obtained from a transmission x-ray microscope. The technique has been experimentally proven to be a feasible coherent x-ray imaging method with about 120 nm spatial resolution and was shown to work well with industrially relevant specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗