Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collective motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Design and pilot evaluation of the RAH-66 Comanche Core AFCS

This paper addresses the design and pilot evaluation of the Core Automatic Flight Control System (AFCS) for the Reconnaissance/Attack Helicopter (RAH-66) Comanche. During the period from November 1991 through February 1992, the RAH-66 Comanche control laws were evaluated through a structured pilot acceptance test using a motion base simulator. Design requirements, descriptions of the control law design, and handling qualities data collected from ADS-33 maneuvers are presented.

Fogler, Donald L., Jr.↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryocrystallography

We have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. Cryocooling is a common technique used for structural data collection to reduce radiation damage in intense X-ray beams and decrease the thermal motion of the atoms. From the thermal images it was clear that during cryocooling a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. As an extension to this work, we used thermal imaging to study small crystals, held in a cryo-loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop for automated structural genomics studies. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryocooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied.

Snell, Eddie↗

Functional Mobility Testing: A Novel Method to Establish Human System Interface Design Requirements

Across all fields of human-system interface design it is vital to posses a sound methodology dictating the constraints on the system based on the capabilities of the human user. These limitations may be based on strength, mobility, dexterity, cognitive ability, etc. and combinations thereof. Data collected in an isolated environment to determine, for example, maximal strength or maximal range of motion would indeed be adequate for establishing not-to-exceed type design limitations, however these restraints on the system may be excessive over what is basally needed. Resources may potentially be saved by having a technique to determine the minimum measurements a system must accommodate. This paper specifically deals with the creation of a novel methodology for establishing mobility requirements for a new generation of space suit design concepts. Historically, the Space Shuttle and the International Space Station vehicle and space hardware design requirements documents such as the Man-Systems Integration Standards and International Space Station Flight Crew Integration Standard explicitly stated that the designers should strive to provide the maximum joint range of motion capabilities exhibited by a minimally clothed human subject. In the course of developing the Human-Systems Integration Requirements (HSIR) for the new space exploration initiative (Constellation), an effort was made to redefine the mobility requirements in the interest of safety and cost. Systems designed for manned space exploration can receive compounded gains from simplified designs that are both initially less expensive to produce and lighter, thereby, cheaper to launch.

England, Scott A.↗

Subsurface Sampling and Sensing Using Burrowing Moles

Finding evidence for life on Mars will likely require accessing the subsurface since the Martian surface is both hostile to life and to preservation of biosignatures due to the cold dry conditions, the strong W environment, and the presence of strong oxidants. Systems are needed to probe beneath the sun and oxidant baked surface of Mars and return samples to the surface for analysis or to bring the instrument sensing underground. Recognizing this need, the European Space Agency incorporated a small subsurface penetrometer or Mole onto the Beagle 2 Mars lander. Had the 2003 landing been successful, the Mole would have collected samples from 1-1.5 m depth and delivered them to an organic analysis instrument on the surface. The de- vice called the Planetary Underground Tool (PLUTO), also measured soil mechanical and thermophysical properties. Constrained by the small mass and volume allowance of the Beagle lander, the PLUTO mole was a slender cylinder only 2 cm diameter and 28 cm long equipped with a small sampling device designed to collect samples and bring them to the surface for analysis by other instrument. The mass of the entire system including deployment mechanism and tether was 1/2 kg. sensor package underground to make in situ measurements. The Mars Underground Mole (MUM) is a larger Mole based on the PLUTO design but incorporating light collection optics that interface to a fiber optic cable in the tether that transmits light to a combined stimulated emission Raman Spectrometer and Short Wave Infrared (SWIR) reflectance Spectrometer with sensitivity from 0.7 to 2.5 micrometers. This instrument is called the Dual Spectral Sensor and uses a Digital Array Scanning Interferometer as the sensor technology, a type of fourier transform interferometer that uses fixed element prisms and thus is highly rugged compared to a Michaelson interferometer. Due to the size limitations of an on-Mole instrument compartment, and the availability of a tether, the sensor head, light sources, and control electronics for the instrument are on the surface. The DSS sensor is capable of sensing a wide range of minerals relevant to Mars Astrobiology objectives including hydrated minerals, clays, carbonates, sulfates, and ice. Additionally, Raman spectroscopy is effective for detecting organics. The MUM is designed to achieve a maximum depth of penetration of 5 m in Mars regolith and can be repeatedly deployed and retrieved. The ability to perform repeated sampling, combined with the low mass and power requirements, means that Moles could be incorporated into a rover mission as well as used on a stationary platform. The Mole mechanism is a pointed slender cylinder that advances into soil by way of an internal sliding hammer mechanism. Part of the energy released by the spring-loaded hammer with each shock is transferred to the Mole casing and from there to the soil, resulting in penetration by displacing and compressing the surrounding soil. A backwards-directed impulse as a re- action to each forward shock is transferred via a suppressor mass against a second weaker spring allowing forward motion without requiring reactive forces provided by the lander. The Mole tip can be opened to collect soil samples. The Mole casing is tethered to a supporting mechanism that supplies power. Components supporting the Mole on the surface include a launch tube, tether reel and winch for pulling in tether, in addition to the tether itself.

Stoker, C. R.↗

Gravity wave motions and momentum fluxes in the middle atmosphere at Adelaide, Australia

A study was made of gravity wave momentum fluxes in the middle atmosphere using data collected during June 1984 at Adelaide, Australia (35 deg S). The primary objectives were to identify that portion of the gravity wave spectrum that contributes most of the momentum transport and flux divergence and to examine the temporal variability of wave energies and momentum fluxes. The data were obtained with an HF (2 MHz) radar operated in a Doppler configuration with two coplanar off-vertical beams. This technique provides a direct measure of the vertical flux of horizontal momentum due to an arbitrary spectrum of gravity wave and other motions in the plane of the radar beams.

Vincent, R. A.↗

Vertical Axis Rotational Motion Cues in Hovering Flight Simulation

A previous study that examined how yaw motion affected a pilot's ability to perform realistic hovering flight tasks indicated that any amount of pure yaw motion had little-to-no effect on pilot performance or opinion. In that experiment, pilots were located at the vehicle's center of rotation; thus lateral or longitudinal accelerations were absent. The purpose of the new study described here was to investigate further these unanticipated results for additional flight tasks, but with the introduction of linear accelerations associated with yaw rotations when the pilot is not at the center of rotation. The question of whether a yaw motion degree-of-freedom is necessary or not is important to government regulators who specify what simulator motions are necessary according to prescribed levels of simulator sophistication. Currently, specifies two levels of motion sophistication for flight simulators: full 6-degree-of-freedom and 3-degree-of-freedom. For the less sophisticated simulator, the assumed three degrees of freedom are pitch, roll, and heave. If other degrees of freedom are selected, which are different f rom these three, they must be qualified on a case-by-case basis. Picking the assumed three axes is reasonable and based upon experience, but little empirical data are available to support the selection of critical axes. Thus, the research described here is aimed at answering this question. The yaw and lateral degrees of freedom were selected to be examined first, and maneuvers were defined to uncouple these motions from changes in the gravity vector with respect to the pilot. This approach simplifies the problem to be examined. For this experiment, the NASA Ames Vertical Motion Simulator was used in a comprehensive investigation. The math model was an AH-64 Apache in hover, which was identified from flight test data and had previously been validated by several AH-64 pilots. The pilot's head was located 4.5 ft in front of the vehicle center of gravity, which is representative of the AH-64 pilot location. Six test pilots flew three tasks that were specifically designed to represent a broad class of situations in which both lateral and yaw motion cues may be useful. For the first task, the pilot controlled only the yaw axis and was required to rapidly acquire a North heading from 15 deg yaw offsets to either the East or West. This task allowed for full, or 1:1, motion to be used in all axes (yaw, lateral, and longitudinal). The second task was a 10 sec., 180 deg. pedal turn over a runway, but with the pilot only controlling the yaw degree-of-freedom. The position of the vehicle's center-of-mass remained fixed. This maneuver was taken from a current U.S. Army rotary wing design standard5 and is representative of a maneuver performed for acceptance of military helicopters; however, it does not allow for full 1:1 motion, since the simulator cab cannot rotate 180 deg. The third task required the pilot to perform a rapid 9 ft climb at a constant heading. This task was challenging, because rapid collective lever movement in the unaugmented AH64 results in a substantial yawing moment (due to engine torque) that must be countered by the pilot. This task also had full motion in all axes, but, in this case, the pilot had two axes to control simultaneously, rather than one as in the previous tasks. Four motion configurations were examined for each task: full motion (except for the 180 deg turn, for which the motion system was configured to provide as much motion as possible), full linear with no yaw motion, full yaw with no linear motion, and no motion. Each configuration was flown four times in a randomized test matrix, and the pilots were not informed of the configuration given. Vehicle state data were recorded for objective performance comparisons, and pilots provided subjective comments and ratings. As part of the pilots' evaluation, they were asked to rate the compensation required, the overall fidelity of the motion as compared to real flight, and whether motion was detected or not in each of the six degrees of freedom. In addition, the pilots provided a numerical level-of confidence rating, between 1 and 7, corresponding to how sure they were whether or not motion was present in each degree-of-freedom. The latter rating allow classical signal detection analysis to be performed.

Schroeder, Jeffrey A.↗

Some tables of the factor of apparent additional mass

This note, prepared for publication by the National Advisory Committee for Aeronautics, is a collection of the tables of the factor of apparent mass that have been published up to now. The theory of the motion of solids in a perfect fluid is of the greatest value for the study of most aerodynamic problems, and the additional apparent mass of an immersed solid is the most important characteristic for such theoretical numerical computations. It will therefore be helpful to have the most important values of the apparent mass - for some elementary cases - collected in a convenient form.

Munk, Max M↗

Reduction in Dynamic Visual Acuity Reveals Gaze Control Changes Following Spaceflight

INTRODUCTION: Exposure to microgravity causes adaptive changes in eye-head coordination that can lead to altered gaze control. This could affect postflight visual acuity during head and body motion. The goal of this study was to characterize changes in dynamic visual acuity after long-duration spaceflight. METHODS: Dynamic Visual Acuity (DVA) data from 14 astro/cosmonauts were collected after long-duration (~6 months) spaceflight. The difference in acuity between seated and walking conditions provided a metric of change in the subjects ability to maintain gaze fixation during self-motion. In each condition, a psychophysical threshold detection algorithm was used to display Landolt ring optotypes at a size that was near each subject s acuity threshold. Verbal responses regarding the orientation of the gap were recorded as the optotypes appeared sequentially on a computer display 4 meters away. During the walking trials, subjects walked at 6.4 km/h on a motorized treadmill. RESULTS: A decrement in mean postflight DVA was found, with mean values returning to baseline within 1 week. The population mean showed a consistent improvement in DVA performance, but it was accompanied by high variability. A closer examination of the individual subject s recovery curves revealed that many did not follow a pattern of continuous improvement with each passing day. When adjusted on the basis of previous long-duration flight experience, the population mean shows a "bounce" in the re-adaptation curve. CONCLUSION: Gaze control during self-motion is altered following long-duration spaceflight and changes in postflight DVA performance indicate that vestibular re-adaptation may be more complex than a gradual return to normal.

Peters, Brian T.↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC)

METRIC is a robotic science laboratory that can determine the mineralogy, elemental chemistry, micromorphology, and thermophysical properties of planetary regolith. The METRIC suite comprises METRIC XRD/F, an X-ray diffraction/X-ray fluorescence instrument that can determine the mineralogy and elemental chemistry of regolith samples; METRIC XCT, a micro X-ray computed tomography instrument that can be used to evaluate grain/crystallite sizes and textures; METRIC IRS, an imaging spectrometer mounted on a rover that can determine mineralogy and thermophysical properties at the landing site; and a pneumatic sample collection, processing, distribution system developed by Honeybee Robotics. The payload elements could be deployed on a static lander or a rover. Data returned from the METRIC payload would inform origin, formation, and evolution of rocky planetary bodies. METRIC XRD/F draws on heritage from the CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover [1], with a few important improvements. Like CheMin, METRIC XRD/F operates in transmission geometry and uses piezoelectric actuators on sample cells in a tuning fork geometry to induce convective grain motion of the regolith to create a randomly oriented powder. MSL CheMin uses an energy-sensitive CCD to collect XRD patterns and XRF spectra simultaneously from the same sample cell, resulting in qualitative XRF data. METRIC XRD/F uses two different sample cells, one optimized for XRD and one optimized for XRF, and a silicon drift detector to detect fluoresced X-rays. This improvement to the XRF capabilities provides quantitative geochemical data of major elements down to Z = 11 and allows for the detection of minor and trace elements that are critical for evaluating geologic evolution of the Moon (e.g., P and Th). Modest improvements to the XRD geometry and hardware allow for better angular resolution and the ability to distinguish between members of the pyroxene group. METRIC XCT uses the same geometry and much of the same hardware as METRIC XRD/F, where a CCD would capture images of a regolith sample in a 3 mm diameter sample tube that is rotated 360° in steps <1°. Image brightness can be used to infer compositional data, where brighter materials indicate a higher Z, much like scanning electron microscopy. Data from METRIC XCT complement those from METRIC XRD/F. Particle size, shape, and texture can provide petrologic and provenance information, whereas vesicle size and morphology in volcanic or impact melt lithologies can inform cooling rates. METRIC IRS is a hyperspectral thermal imager that can be mounted to a lander or rover to provide mineralogical data from the broader landing site and help determine whether the samples analyzed by METRIC XRD/F and XCT are representative. The METRIC IRS spectral range (8–14 μm) and resolution (10.8 cm-1) allow for quantitative mineralogy from modelling Reststrahlen bands of major rock-forming minerals (e.g., silicates, phosphates). Radiance cubes can be processed and modelled with an onboard high-performance computer to determine mineral abundances of plagioclase, high-Ca pyroxene, pigeonite, orthopyroxene, olivine, and glass. Regolith samples can be acquired, processed, and delivered to the X-ray instruments via multiple sample handling systems, but the pneumatic sampling systems developed by Honeybee Robotics [e.g., 2] are best suited for relatively low-cost missions that are being competed for the Moon (e.g., NASA’s Payloads and Research Investigations for the Surface of the Moon program). There are pneumatic sampling systems that collect surface material and other systems that pneumatically drill up to ~1 m below the surface, providing material that has not been space weathered and has not been affected by the lander’s exhaust. [1] Blake, D. F., Vaniman, D., Achilles, C., Anderson, R., Bish, D., et al. (2012). Space Sci. Rev. 170, 341-478. https://doi.org/10.1007/s11214-012-9905-1. [2] Zacny, K., Betts, B., Hedlund, M., Long, P., Gramlich, M., Tura, K., Chu, P., Jacob, A., Garcia, A. (2014). IEEE Aerospace Conference, 3-7 March 2014, Big Sky, MT, U.S.A.

X-ray diffraction↗

Lessons Learned from Performance Testing of Humans in Spacesuits in Simulated Reduced Gravity

Introduction: The overarching objective of the Integrated Suit Test (IST) series is to evaluate suited human performance using reduced-gravity analogs and learn what aspects of an EVA suit system affect human performance. For this objective to be successfully achieved, the testing methodology should be valid and reproducible, and the partial-gravity simulations must be as accurate and realistic as possible. Objectives: To highlight some of the key lessons learned about partial-gravity analogs and testing methodology, and to suggest considerations for optimizing the effectiveness and quality of results of future tests. Methods: Performance testing of suited and unsuited subjects was undertaken in different reduced-gravity analogs including the Space Vehicle Mockup Facility s Partial Gravity Simulator (POGO), parabolic flight on the C-9 aircraft, underwater environments including NASA s Extreme Environment Mission Operations (NEEMO) and the Neutral Buoyancy Lab (NBL), and in field analogs including Desert Research and Technology Studies (RATS), the Haughton Mars Project (HMP), and the JSC Rock Pile. Subjects performed level walking, incline/decline walking, running, shoveling, picking up and transferring rocks, kneeling/standing, and task boards. Lessons Learned Analogs: No single analog will properly simulate all aspects of the true partial-gravity environment. The POGO is an ideal environment from the standpoint that there are no time limits or significant volumetric constraints, but it does have several limitations. It allows only 2 translational degrees of freedom (DOF) and applies true partial-gravity offload only through the subject s center of gravity (CG). Also, when a subject is doing non-stationary tasks, significant overhead inertia from the lift column seems to have a negative impact on performance. Parabolic flight allows full translational and rotational DOF and applies offload to all parts of the body, but the simulation lasts less than 30 seconds. When this is coupled with the volumetric constraints of the plane, both task selection and data collection options are significantly limited. The underwater environments also allow all 6 DOF and allow off-loading to be applied throughout the body, but the data collection capabilities are limited to little more than subjective ratings. In addition, water drag negatively affects performance of tasks requiring dynamic motion. Field analogs provide the ability to simulate lunar terrain and more realistic mission-like objectives, but all of them operate at 1-g, so suited human performance testing generally must utilize a reduced-mass or "mockup" suit, depending on study objectives. In general, the ground-based overhead-suspension partial-gravity analogs like POGO allow the most diverse data collection methods possible while still simulating partial gravity. However, as currently designed, the POGO has significant limitations. Design of the Active Response Gravity Offload System (ARGOS) has begun and is focusing on adding full x,y,z translational DOF, improved offload accuracy, increased lift capacity, and active control of the x and y axes to minimize offload system inertia. Additionally, a new gimbal is being designed to reduce mass and inertia and to be able to work with different suits, as the current gimbal only supports suited testing with the Mark III Technology Demonstrator Suit (MKIII).

Norcross, Jason R.↗

Motion Perception and Manual Control Performance During Passive Tilt and Translation Following Space Flight

This joint ESA-NASA study is examining changes in motion perception following Space Shuttle flights and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data has been collected on 5 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s) combined with body translation (12-22 cm, peak-to-peak) is utilized to elicit roll-tilt perception (equivalent to 20 deg, peak-to-peak). A forward-backward moving sled (24-390 cm, peak-to-peak) with or without chair tilting in pitch is utilized to elicit pitch tilt perception (equivalent to 20 deg, peak-to-peak). These combinations are elicited at 0.15, 0.3, and 0.6 Hz for evaluating the effect of motion frequency on tilt-translation ambiguity. In both devices, a closed-loop nulling task is also performed during pseudorandom motion with and without vibrotactile feedback of tilt. All tests are performed in complete darkness. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for translation motion perception to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. The results of this study indicate that post-flight recovery of motion perception and manual control performance is complete within 8 days following short-duration space missions. Vibrotactile feedback of tilt improves manual control performance both before and after flight.

Clement, Gilles↗

Direct writing of PVBVA/Ti 3 C 2 T x (MXene) triboelectric nanogenerators for energy harvesting and sensing applications

Triboelectric nanogenerators (TENGs) have gained recognition for their potential to convert mechanical energy into electrical energy, making them attractive for applications in healthcare, robotics, and human-device interfaces. However, many TENG devices rely on fluorinated polymers for high charge generation and involve complex fabrication processes, which limit their practicality and environmental sustainability. Here, we developed an eco-friendly composite of poly (vinyl butyral-co-vinyl alcohol-co-vinyl acetate) (PVBVA) and Ti 3 C 2 T x MXene for extrusion printing onto aluminum foil substrates, enabling the additive manufacturing of TENGs. Experimental results indicate that integrating 5.5 mg mL -1 of MXene (P-MX 5.5) into PVBVA resulted in a power density of 760 mW·m -2 , with simultaneous improvements in open-circuit voltage (129 %) and short-circuit current (250 %), demonstrating enhanced charge transfer efficiency. Beyond aluminum foil-based devices, we further explored the fully printed P-MX 5.5 TENG by utilizing silver ink electrodes, eliminating the need for aluminum foil. This fully printed, flexible TENG was successfully used for real-time human motion sensing, demonstrating its ability to detect activities such as walking, running, knee bending, and jumping. Collectively, our additively manufactured and sustainable PVBVA-MXene TENG composites, including both aluminum-based and fully printed versions, show promise for future energy harvesters, sensors, wearable electronics, healthcare, and robotic applications.

Additive manufacturing↗

A densely spaced array of sea level monitors for the detection of vertical crustal deformation in the Shumagin seismic gap, Alaska

A network of sea level gauges has been installed with about 40 km spacing in the Shumagin Islands in order to detect relative vertical motion, in particular, possible crustal motion precursory to an expected major earthquake. This required the development and deployment of a pressure sensor sea level gauge suitable for installation on remote and harsh coastlines. Data are collected in near-real-time via satellite, both in order to exploit fully any precursors that may be observed and to provide continuous information on the status of the instruments. Using Wiener filtering techniques, it has been determined conservatively that no relative vertical crustal motion greater than 0.1 m between stations has occurred during 1981-1985. This is consistent with independent geodetic leveling and trilateration data, though evidence exists for more rapid deformation during 1978-1980. The sea level data collected so far have an rms noise level of about 0.04 m after processing; this is limited in part by the pressure sensor and associated electronics. Improved prressure gauges with better long-term stability have recently been installed. A short-baseline tiltmeter operating in a tunnel has demonstrated that suitably designed and located land-based tiltmeters have a lower noise level, and hence better precursor detection characteristics than the sea level gauges, at monthly and shorter periods.

Beavan, John↗

Analysis of cryogenic propellant behavior in microgravity and low thrust environments

Predictions of a CFD program calculating a fluid-free surface shape and motion as a function of imposed acceleration are validated against the drop-tower test data collected to support design and performance assessments of the Saturn S-IVB stage liquid-hydrogen tank. The drop-tower facility, experimental package, and experiment procedures are outlined, and the program is described. It is noted that the validation analysis confirms the program's suitability for predicting low-g fluid slosh behavior, and that a similar analysis could examine the effect of incorporating baffles and screens to impede initiation of any unwanted side loads due to slosh. It is concluded that in actual vehicle applications, the engine thrust tailoff profile should be included in computer simulations if the precise interface versus time definition is needed.

Fisher, Mark F.↗

Monitoring Global Sea Level: Eustatic Variations, Local Variations, and Solid Earth Effects

Project BIFROST (Baseline Inferences for Fennoscandian Rebound Observations. Sea-level and Tectonics) combines networks of continuously operating CPS receivers in Sweden and Finland to measure ongoing crustal deformation due to glacial isostatic adjustment, (CIA). We present an analysis of data collected in the years 1993-1998. We compare the CPS determinations of three-dimensional crustal motion to predictions calculated using the high resolution Fennoscandian deglaciation model recently proposed by Lambeck et al. We find that the the maximum observed uplift rate (approx. 10 mm/ yr) and the maximum predicted uplift rate agree to better than 1 mm/ yr. The patterns of uplift also agree quite well, although differences are discernible. The chi(exp 2) difference between predicted and GPS-observed radial rates is reduced by a factor of 5-6 compared to that for the "null" (no uplift) model, depending on whether a mean difference is first removed. The north components of velocity agree at about the same relative level. whereas the agreement for the east components is worse, a problem possibly related to the lack of bias fixing. We have also compared the values for the observed radial deformation rates to those based on sea-level rates from Baltic tide gauges. The weighted RMS difference between CPS and tide-gauge rates (after removing a mean) is 0.6 mm/ yr, giving an indication of the combined accuracy of the CPS and tide-gauge measurement systems. Spectral analysis of the time series of position estimates yields spectral indices in the range -1 to -2. An EOF analysis indicates, however, that much of this power is correlated among the sites. The correlation appears to be regional and falls off only slightly with distance. Some of this correlated noise is associated with snow accumulation on the antennas or, for those antennas with radomes, on the radomes. This problem has caused us to modify the radomes used several times, leading to one of our more significant sources of uncertainty.

Davis, James L.↗

Electrodynamic Tether Operations beyond the Ionosphere in the Low-Density Magnetosphere

In the classical concept for the operation of electrodynamic tethers in space, a voltage is generated across the tether, either by the tether's orbital motion through the earth's planetary magnetic field or by a power supply; electrons are then collected from the ionospheric plasma at the positive pole; actively emitted back into space at the negative pole; and the circuit is closed by currents driven through the ambient conducting ionosphere. This concept has been proven to work in space by the Tethered Satellite System TSS-1 and TSS-1R Space Shuttle missions; and the Plasma Motor-Generator (PMG) tether flight experiment. However, it limits electrodynamic tether operations to the F-region of the ionosphere where the plasma density is sufficient to conduct the required currents--in other words, between altitudes of approximately 200 to 1000 km in sunlight. In the earth's shadow, the ionospheric density drops precipitously and tether operations, using the above approach, are not effective--even within this altitude range. There are numerous missions that require in-space propulsion in the Earth's shadow and/or outside of the above altitude range. This paper will, therefore, present the fundamentals of a concept that would allow electrodynamic tethers to operate almost anywhere within the magnetosphere, the region of space containing the earth's planetary magnetic field. In other words, because operations would be virtually independent of any ambient plasma, the range of electrodynamic operations would be extended into the earth's shadow and out to synchronous orbit--forty times the present operational range. The key to this concept is the active generation of plasma at each pole of the tether so that current generation ,does not depend on the conductivity of the ambient ionosphere. Arguments will be presented, based on ,existing flight data, which shed light on the behavior of charge emissions in space and show the plausibility of the concept.

Stone, Nobie H.↗

A New Method for Interfacing Unsuited Subjects to Overhead Suspension Partial Gravity Simulators

The purpose of performing unsuited testing as part of a reduced gravity extravehicular (EVA) suited human performance research program is to define baseline performance. These results are then coupled with suited test results to evaluate how the suit system affects human performance at reduced gravity. The primary drawback to this approach is that previous studies used notably different systems to interface suited and unsuited subjects to overhead-suspension, partial-gravity simulators. A spreader bar (SB) assembly previously used for unsuited tests allowed limited pitch and roll of the subject, whereas the gimbal for suited tests allowed more pitch and roll, although the mass distribution led to large moments of inertia in the yaw axis. It is hypothesized that use of the same methods for offload of both unsuited and suited subjects is needed to make meaningful comparisons. A new gimbal (GIM) was designed with the idea that it could function with both suited and unsuited subjects. GIM was designed to minimize mass and moments of inertia and to be adjustable to co-locate the 3 axes of rotation with the subject s center of gravity. OBJECTIVE: To evaluate human performance differences between SB and GIM. METHODS: Ten unsuited subjects were off-loaded to 1/6-g using both interfaces. Subjects completed tasks including overground and treadmill ambulation, picking up objects, shoveling, postural stability, range of motion testing, and recovery from the kneeling and prone positions. Metabolic, biomechanical, and/or subjective data were collected based on task. RESULTS: Initial analyses suggest that subjects completed all tasks with lower levels of compensation and a more terrestrial approach to movement when suspended via GIM. With SB, subjects were not able to fall or get into a prone position and had increased difficulty both retrieving objects off the floor and with overground ambulation, especially at gait initiation, because they were unable to bend their torso. GIM shows promise as a new method.

Norcross, Jason R.↗