Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Compilation of Published PM2.5 Emission Rates for Cooking, Candles and Incense for Use in Modeling of Exposures in Residences

recent analysis of health impacts from air pollutant inhalation in homes found that PM2.5 is the most damaging at the population level. Chronic exposure to elevated PM2.5 has the potential to damage human respiratory systems, and may result in premature death. PM2.5 exposures in homes can be mitigated through various approaches including kitchen exhaust ventilation, filtration, indoor pollutant source reduction and designing ventilation systems to reduce the entry of PM2.5 from outdoors. Analysis of the potential benefits and costs of various approaches can be accomplished using computer codes that simulate the key physical processes including emissions, dilution and ventilation. The largest sources of PM2.5 in residences broadly are entry from outdoors and emissions from indoor combustion. The largest indoor sources are tobacco combustion (smoking), cooking and the burning of candles and incense. Data on the magnitude of PM2.5 and other pollutant emissions from these events and processes are required to conduct simulations for analysis. The goal of this study was to produce a database of pollutant emission rates associated with cooking and the burning of candles and incense. The target use of these data is for indoor air quality modeling.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Compilation of LLNL CUP-2 Data

The CUP-2 uranium ore concentrate (UOC) standard reference material, a powder, was produced at the Blind River uranium refinery of Eldorado Resources Ltd. in Canada in 1986. This material was produced as part of a joint effort by the Canadian Certified Reference Materials Project and the Canadian Uranium Producers Metallurgical Committee to develop a certified reference material for uranium concentration and the concentration of several impurity constituents. This standard was developed to satisfy the requirements of the UOC mining and milling industry, and was characterized with this purpose in mind. To produce CUP-2, approximately 25 kg of UOC derived from the Blind River uranium refinery was blended, homogenized, and assessed for homogeneity by X-ray fluorescence (XRF) analysis. The homogenized material was then packaged into bottles, containing 50 g of material each, and distributed for analysis to laboratories in 1986. The CUP-2 UOC standard was characterized by an interlaboratory analysis program involving eight member laboratories, six commercial laboratories, and three additional volunteer laboratories. Each laboratory provided five replicate results on up to 17 analytes, including total uranium concentration, and moisture content. The selection of analytical technique was left to each participating laboratory. Uranium was reported on an “as-received” basis; all other analytes (besides moisture content) were reported on a “dry-weight” basis. A bottle of 25g of CUP-2 UOC standard as described above was purchased by LLNL and characterized by the LLNL Nuclear Forensics Group. Non-destructive and destructive analytical techniques were applied to the UOC sample. Information obtained from short-term techniques such as photography, gamma spectrometry, and scanning electron microscopy were used to guide the performance of longer-term techniques such as ICP-MS. Some techniques, such as XRF and ICP-MS, provided complementary types of data. The results indicate that the CUP-2 standard has a natural isotopic ratio, and does not appear to have been isotopically enriched or depleted in any way, and was not contaminated by a source of uranium with a non-natural isotopic composition. Furthermore, the lack of 233 U and 236 U above the instrumental detection limit indicates that this sample was not exposed to a neutron flux, which would have generated one or both of these isotopes in measurable concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biota Modeling in EPA’s Preliminary Remediation Goal and Dose Compliance Concentration Calculators for Use in EPA Superfund Risk Assessment: Explanation of Intake Rate Derivation, Transfer Factor Compilation, and Mass Loading Factor Sources

The Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) calculators are screening level tools that set forth Environmental Protection Agency’s (EPA) recommended approaches, based upon currently available information with respect to risk assessment, for response actions at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites, commonly known as Superfund. The screening levels derived by the PRG and DCC calculators are used to identify isotopes contributing the highest risk and dose as well as establish preliminary remediation goals. Each calculator has a residential gardening scenario and subsistence farmer exposure scenarios that require modeling of the transfer of contaminants from soil and water into various types of biota (crops and animal products). New publications of human intake rates of biota; farm animal intakes of water, soil, and fodder; and soil to plant interactions require updates be implemented into the PRG and DCC exposure scenarios. Recent improvements have been made in the biota modeling for these calculators, including newly derived biota intake rates, more comprehensive soil mass loading factors (MLFs), and more comprehensive soil to tissue transfer factors (TFs) for animals and soil to plant transfer factors (BV’s). New biota have been added in both the produce and animal products categories that greatly improve the accuracy and utility of the PRG and DCC calculators and encompass greater geographic diversity on a national and international scale.

54 ENVIRONMENTAL SCIENCES↗

PV System Component Fault and Failure Compilation and Analysis.

This report describes data collection and analysis of solar photovoltaic (PV) equipment events, which consist of faults and fa ilures that occur during the normal operation of a distributed PV system or PV power plant. We present summary statistics from locations w here maintenance data is being collected at various intervals, as well as reliability statistics gathered from that da ta, consisting of fault/failure distributions and repair distributions for a wide range of PV equipment types.

14 SOLAR ENERGY↗

Compilation of Site Names and Spatial Extents for Sites in the Hanford Site Disposition Database

Several analyses that will be completed as part of the Hanford Composite Analysis (CA) and Cumulative Impact Evaluation (CIE) require the extents of facilities, waste sites, and other locations on the Hanford Site. The purpose of this calculation is to provide spatial extents and consistent naming convention for those locations used as part of the analyses in a single dataset. This calculation documents the process used to develop the dataset.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Compilation for AGR-2 B&W UO2 Coated Particle Batch G73H-10-93085B

Coated particle fuel batch G73H-10-93085B was produced by the Babcock and Wilcox Company (B&W) for use as UO₂ fuel for the Advanced Gas Reactor Fuel Development and Qualification Program’s AGR-2 irradiation test. Batch G73H-10-93085B is a single batch of TRISO-coated 500 μm nominal diameter 10% low enrichment uranium oxide kernels (LEU). The TRISO-coatings consist of a ~50% dense carbon buffer layer (100 μm nominal thickness) followed by a dense inner pyrocarbon layer (40 μm nominal thickness) followed by a SiC layer (35 μm nominal thickness) followed by another dense outer pyrocarbon layer (40 μm nominal thickness). Argon was added to the hydrogen fluidization gas during SiC deposition. The AGR-2 Fuel Specification (INL SPC-923) provides the requirements necessary for acceptance of the fuel manufactured for the AGR-2 irradiation test. The bulk of the kernels and coated particle acceptance testing was performed at B&W and is not contained in this report. B&W samples NP-B8488, NP-B8489, and NP-B8490 (all from batch G73H-10-93085B) were sent to ORNL for characterization and compacting. These samples were composited and renamed LEU10. Samples were then riffled for supplemental characterization. The procedures for the limited characterization and qualification of the particles performed at ORNL are outlined in ORNL product inspection plan AGR-CHAR-PIP-09. The BAFo equivalent optical anisotropies of the inner and outer pyrocarbon layers are reported on Inspection Report Form IRF-09, with a determination as to whether the particle batch satisfied the specified parameters for this property. The batch was found to satisfy the AGR-2 Fuel Specification SPC-923, Rev. 1 for IPyC and OPyC anisotropy. Also provided in this data package are data on the true BAFo, average particle weight, and SiC soot inclusion defect fraction. True BAFo is calculated as (1+N)/(1-N), where N is the diattenuation. This differs from equivalent BAFo = 1+3N, which is the calculation used by the fuel specification to allow comparison to historical measurements. Three SiC inclusions were found in a sample of 3510 particles. This corresponds to a defect fraction of <2.3E-3 at 95% confidence. One of these inclusions was of unusual appearance and was determined to contain molybdenum using energy dispersive x-ray analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Compilation of Historical Data on Hagan Drop Testing with Results

The Hagan nuclear material storage container was designed in the late 1990’s to provide a robust container for daily use, safe transport within the plutonium facility PF-4, and storage of nuclear material for up to twenty years. There are currently >3000 loaded Hagan containers in use at TA-55. The majority of these are in the TA-55 vault, but they are also used in safes and in floor locations on the main floor of PF-4. The original design criteria are given below

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Biota Modeling in EPA’s Preliminary Remediation Goal and Dose Compliance Concentration Calculators for Use in EPA Superfund Risk Assessment: Explanation of Intake Rate Derivation, Transfer Factor Compilation, and Mass Loading Factor Sources

The Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) calculators are screening level risk assessment tools that set forth the Environmental Protection Agency’s (EPA) recommended approaches and currently available risk assessment guidance for response actions at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites, commonly known as Superfund. The environmental screening levels derived by the PRG and DCC calculators are used to identify isotopes contributing the highest risk and dose as well as establish preliminary remediation goals. Each calculator has residential gardening and subsistence farmer exposure scenarios that model transfer of contaminants from soil and water into various types of biota (crops and animal products). New publications of human intake rates of biota; farm animal intakes of water, soil, and fodder; and soil to plant interactions require updates be implemented into the PRG and DCC calculators. Recent improvements in the biota modeling for these calculators include newly derived biota intake rates, enhanced soil mass loading factors (MLFs), and more comprehensive soil to plant transfer factors (BV’s) and soil to tissue transfer factors (TFs) for animals. New biota have been added in both the produce and animal products categories that greatly improve the accuracy and utility of the PRG and DCC calculators and encompass greater geographic diversity on a national and international scale.

54 ENVIRONMENTAL SCIENCES↗

Compilation and Evaluation of Data from Groundwater Impounded within the U12n and U12t Tunnels, Rainier and Aqueduct Mesas, Nevada National Security Site

The Department of Defense (DOD) Defense Threat Reduction Agency (DTRA) and the U.S. Department of Energy (DOE) Office of Environmental Management Nevada Program (EM NV) conducted routine physical and geochemical monitoring of water impounded behind impermeable structures placed within the U12n and U12t tunnels on the Nevada National Security Site (NNSS) (formerly the Nevada Test Site [NTS]). Desert Research Institute (DRI) conducted a semiquantitative evaluation of pressure data to determine the extent to which the tunnels have been inundated and a qualitative evaluation of monitored geochemical parameters to determine if trends exist that were indicative of hydrologic and/or geochemical processes operating behind the tunnel plugs. Data were also evaluated to determine if monitored radiological parameters exceeded primary standards associated with the Environmental Protection Agency’s (EPA) Safe Drinking Water Act (SDWA) (40 C.F.R. § 141.66).

54 ENVIRONMENTAL SCIENCES↗