Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Application of partially coherent wavefront propagation calculations for design of coherence-preserving synchrotron radiation beamlines

Ultra-low emittance third-generation synchrotron radiation (SR) sources, such as NSLS-II and MAX-IV, will offer excellent opportunities for further development of experimental techniques exploiting X-ray coherence. However, even in these new SR sources, the radiation produced by relativistic electrons (in undulators, wigglers and bending magnets) will remain only partiallycoherent in the X-ray spectral range. 'Extraction' of 'coherent portion' of the radiation flux and its transport to sample without loss of coherence must be performed by dedicated SR beamlines, optimized for particular types of experiments. Detailed quantitative prediction of partially coherent X-ray beam properties at propagation through optical elements, which is required for the optimization of such beamlines, can only be obtained from accurate and efficient physical-optics based numerical simulations. Examples of such simulations, made for NSLS-II beamlines, using 'Synchrotron Radiation Workshop' (SRW) computer code, are presented. Special attention is paid to the numerical analysis of the basic properties of partially coherent undulator radiation beam and its distinctions from the Gaussian beam. Performance characteristics of importance for particular beamlines, such as radiation spot size and flux at sample vs size of secondary source aperture for high-resolution microscopy beamlines, are predicted by the simulations.

43 PARTICLE ACCELERATORS↗

The hard x-ray nanotomography microscope at the advanced light source

Beamline 11.3.1 at the Advanced Light Source is a tender/hard (6–17 keV) x-ray bend magnet beamline recently re-purposed with a new full-field, nanoscale transmission x-ray microscope. The microscope is designed to image composite and porous materials possessing a submicrometer structure and compositional heterogeneity that determine materials’ performance and geologic behavior. The theoretical and achieved resolutions are 55 and <100 nm, respectively. The microscope is used in tandem with a <25 nm eccentricity rotation stage for high-resolution volume imaging using nanoscale computed tomography. The system also features a novel bipolar illumination condenser for the illumination of an ~100 μm spot of interest on the sample, followed by a phase-type zone plate magnifying objective of ~52 µm field of view and a phase detection ring. The zone plate serves as the system objective and magnifies the sample with projection onto an indirect x-ray detection system, consisting of a polished single crystal CsI(Tl) scintillator and a range of high-quality Plan Fluorite visible light objectives. The objectives project the final visible light image onto a water-cooled CMOS 2048 × 2048-pixel 2 detector. Here, in this paper, we will discuss the salient features of this instrument and describe early results from imaging the internal three-dimensional microstructure and nanostructure of target materials, including fiber-reinforced composites and geomaterials.

47 OTHER INSTRUMENTATION↗

Modifying the Asynchronous Jacobi Method for Data Corruption Resilience

Moving scientific computation from high-performance computing (HPC) and cloud computing (CC) environments to devices on the edge, i.e., physically near instruments of interest, has received tremendous interest in recent years. Such edge computing environments can operate on data in situ, offering enticing benefits over data aggregation to HPC and CC facilities that include avoiding costs of transmission, increased data privacy, and real-time data analysis. Because of the inherent unreliability of edge computing environments, new fault-tolerant approaches must be developed before the benefits of edge computing can be realized. Motivated by algorithm-based fault tolerance, a variant of the asynchronous Jacobi (ASJ) method is developed that achieves resilience to data corruption by rejecting solution approximations from neighbor devices according to a bound derived from convergence theory. Numerical results on a two-dimensional Poisson problem show that the new rejection criterion, along with a novel approximation to the shortest path length on which the criterion depends, restores convergence for the ASJ variant in the presence of certain types data corruption. Numerical results are obtained for when the singular values in the analytic bound are approximated. Additional linear systems are also explored, one with a more dense sparsity pattern and one that includes advection. All results indicate that successful resilience to data corruption depends on whether the bound tightens fast enough to reject corrupted data before the iteration evolution deviates significantly from that predicted by the convergence theory defining the bound. This observation generalizes to future work on algorithm-based fault tolerance for other asynchronous algorithms, including upcoming approaches that leverage Krylov subspaces.

97 MATHEMATICS AND COMPUTING↗

The Role of National Research and Education Networks Providing Connectivity and Advanced Network Services to Virtual Communities in Collaborative R&E Projects. CUDI: The Mexican Case Part 1, , In: ISUM 2015: High Performance Computer Applications

This paper describes the role of National Research and Education Networks (NRENs) and their aim to provide a seamless, large scale, high-speed, low-latency network to accelerate scientific and education discovery for national, regional or global collaborative projects that are dependent on the use of modern high performance distributed computing systems (HPDCS) to process mathematical models, produce new knowledge and drive innovation when resolving complex problems. NRENs have become the mainstream of communication and collaboration to integrate the efforts of large geographically distributed teams of Virtual Communities (VC) that - train, teach and learn-, -create, use and share- knowledge, data, information and communications technology resources (e.g. computer and information systems, middleware, tools, instruments, data sets, repositories, applications and services) building e-infrastructures necessary to meet the collaborative projects’ goals. The paper focuses on the current status of the Mexican NREN: CUDI, its future organization and political support, necessary to provide seamless, large scale, high-speed, low latency and secure national backbone and international links providing connectivity, advanced network services and technical support to VCs and their e-infrastructures in collaborative R&E projects within the country, the LAC region and worldwide.

Computer Science↗

A nano-structured ZnO film as diagnostic X-ray sensor

Currently some international organizations such as WHO and IAEA have shown concerns about the quality of diagnostic services in clinics and hospitals that use ionizing radiation. In fact, the IAEA recommend that the characteristics of the X-ray beam must be adjusted to obtain the highest quality of the radiographic image with the minimum exposure to the patient. Several types of detectors may be used for monitoring X-ray beams, such as: ionization chamber, photodiode, phototransistor, among others. Recently nano-structured films made of various types of metal oxide materials have been used for various technological applications. Accordingly, the purpose of this paper is to present a sort of device based on a nano-structured zinc oxide (ZnO) to operate as a diagnostic X-ray sensor. By depositing a thin film on the glass substrate some ZnO semiconductor samples were built by sputtering techniques and then mounted in a BNC type connector to perform the electrical characterization. To test the device, we choose a standard X-Ray beam, the RQR9 radiation quality, which is normally used as the tool and condition for calibrating diagnostic X-Ray instruments in the energy range of computed tomography, in accordance with the stated requirements of IEC 61267. A 6430 sub-femto-ammeter, Keithley, was used as electrometer to perform the output readings and simultaneously bias the ZnO sensor. Analysis of the angular dependence and the dose rate were performed to evaluate how the device responds under the RQR9 radiation spectra. Although the results have shown that the ZnO film presents a certain angular dependence, if an angle of incidence of photons is selected, the device displays reproducibility as X-ray sensor and has the feature of radiation hardness unlike other types of semiconductor electronic devices typically used as an X-ray detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY 2019 Site-Directed Research & Development (Annual Report Overview)

This overview of the Fiscal Year 2019 Site-Directed Research & Development program and the Nevada National Security Site contains information regarding the program’s history and growth, leadership, project selection process, present areas of research, highlights of significant accomplishments and awards, noteworthy people, and performance metrics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Site-Directed Research & Development Annual Report Overview FY 2020

The SDRD program’s annual report for fiscal year 2020 consists of two parts: the program overview, which contains three major sections, Program Description, Program Accomplishments, and Program Value, and individual project report summaries published electronically on the Nevada National Security Site’s website, www.nnss.gov/pages/programs/sdrd.html. Complete technical reports for concluding projects are available from the Office of Scientific and Technical Information (OSTI) or the principal investigator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling reactive microscopy with MicroMator

Microscopy image analysis has recently made enormous progress both in terms of accuracy and speed thanks to machine learning methods and improved computational resources. This greatly facilitates the online adaptation of microscopy experimental plans using real-time information of the observed systems and their environments. Applications in which reactiveness is needed are multifarious. Here we report MicroMator, an open and flexible software for defining and driving reactive microscopy experiments. It provides a Python software environment and an extensible set of modules that greatly facilitate the definition of events with triggers and effects interacting with the experiment. We provide a pedagogic example performing dynamic adaptation of fluorescence illumination on bacteria, and demonstrate MicroMator’s potential via two challenging case studies in yeast to single-cell control and single-cell recombination, both requiring real-time tracking and light targeting at the single-cell level.

47 OTHER INSTRUMENTATION↗

Characterization of the neutron irradiation system for use in the Low-Dose-Rate Irradiation Facility at Sandia National Laboratories.

The objective of this work was to characterize the neutron irradiation system consisting of americium-241 beryllium (241AmBe) neutron sources placed in a polyethylene shielding for use at Sandia National Laboratories (SNL) Low Dose Rate Irradiation Facility (LDRIF). With a total activity of 0.3 TBq (9 Ci), the source consisted of three recycled 241AmBe sources of different activities that had been combined into a single source. The source in its polyethylene shielding will be used in neutron irradiation testing of components. The characterization of the source-shielding system was necessary to evaluate the radiation environment for future experiments. Characterization of the source was also necessary because the documentation for the three component sources and their relative alignment within the Special Form Capsule (SFC) was inadequate. The system consisting of the source and shielding was modeled using Monte Carlo N-Particle transport code (MCNP). The model was validated by benchmarking it against measurements using multiple techniques. To characterize the radiation fields over the full spatial geometry of the irradiation system, it was necessary to use a number of instruments of varying sensitivities. First, the computed photon radiography assisted in determining orientation of the component sources. With the capsule properly oriented inside the shielding, the neutron spectra were measured using a variety of techniques. A N-probe Microspec and a neutron Bubble Dosimeter Spectrometer (BDS) set were used to characterize the neutron spectra/field in several locations. In the third technique, neutron foil activation was used to ascertain the neutron spectra. A high purity germanium (HPGe) detector was used to characterize the photon spectrum. The experimentally measured spectra and the MCNP results compared well. Once the MCNP model was validated to an adequate level of confidence, parametric analyses was performed on the model to optimize for potential experimental configurations and neutron spectra for component irradiation. The final product of this work is a MCNP model validated by measurements, an overall understanding of neutron irradiation system including photon/neutron transport and effective dose rates throughout the system, and possible experimental configurations for future irradiation of components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GPU COMPUTING FOR PARTICLE TRACKING

This is a feasibility study of using a modern Graphics Processing Unit (GPU) to parallelize the accelerator particle tracking code. To demonstrate the massive parallelization features provided by GPU computing, a simplified TracyGPU program is developed for dynamic aperture calculation. Performances, issues, and challenges from introducing GPU are also discussed. General purpose Computation on Graphics Processing Units (GPGPU) bring massive parallel computing capabilities to numerical calculation. However, the unique architecture of GPU requires a comprehensive understanding of the hardware and programming model to be able to well optimize existing applications. In the field of accelerator physics, the dynamic aperture calculation of a storage ring, which is often the most time consuming part of the accelerator modeling and simulation, can benefit from GPU due to its embarrassingly parallel feature, which fits well with the GPU programming model. In this paper, we use the Tesla C2050 GPU which consists of 14 multi-processois (MP) with 32 cores on each MP, therefore a total of 448 cores, to host thousands ot threads dynamically. Thread is a logical execution unit of the program on GPU. In the GPU programming model, threads are grouped into a collection of blocks Within each block, multiple threads share the same code, and up to 48 KB of shared memory. Multiple thread blocks form a grid, which is executed as a GPU kernel. A simplified code that is a subset of Tracy++ [2] is developed to demonstrate the possibility of using GPU to speed up the dynamic aperture calculation by having each thread track a particle.

42 ENGINEERING↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Secure Collaborative Environment for Seamless Sharing of Scientific Knowledge

In a secure collaborative environment, tera-bytes of data generated from powerful scientific instruments are used to train secure machine learning (ML) models on exascale computing systems, which are then securely shared with internal or external collaborators as cloud-based services. Devising such a secure platform is necessary for seamless scientific knowledge sharing without compromising individual, or institute-level, intellectual property and privacy details. By enabling new computing opportunities with sensitive data, we envision a secure collaborative environment that will play a significant role in accelerating scientific discovery. Several recent technological advancements have made it possible to realize these capabilities. In this paper, we present our efforts at ORNL toward developing a secure computation platform. We present a use case where scientific data generated from complex instruments, like those at the Spallation Neutron Source (SNS), are used to train a differential privacy enabled deep learning (DL) network on Summit, which is then hosted as a secure multi-party computation (MPC) service on ORNL’s Compute and Data Environment for Science (CADES) cloud computing platform for third-party inference. In this feasibility study, we discuss the challenges involved, elaborate on leveraged technologies, analyze relevant performance results and present the future vision of our work to establish secure collaboration capabilities within and outside of ORNL.

Yoginath, Srikanth↗

Deep learning-based segmentation of lithium-ion battery microstructures enhanced by artificially generated electrodes

Accurate 3D representations of lithium-ion battery electrodes, in which the active particles, binder and pore phases are distinguished and labeled, can assist in understanding and ultimately improving battery performance. Here, we demonstrate a methodology for using deep-learning tools to achieve reliable segmentations of volumetric images of electrodes on which standard segmentation approaches fail due to insufficient contrast. We implement the 3D U-Net architecture for segmentation, and, to overcome the limitations of training data obtained experimentally through imaging, we show how synthetic learning data, consisting of realistic artificial electrode structures and their tomographic reconstructions, can be generated and used to enhance network performance. We apply our method to segment x-ray tomographic microscopy images of graphite-silicon composite electrodes and show it is accurate across standard metrics. We then apply it to obtain a statistically meaningful analysis of the microstructural evolution of the carbon-black and binder domain during battery operation.

25 ENERGY STORAGE↗

Label-free nanoscopy of cell metabolism by ultrasensitive reweighted visible stimulated Raman scattering

Nanoscopic imaging of cell metabolism is hindered by the incompatibility of small metabolites with fluorescent dyes and the limited resolution of imaging mass spectrometry. We present ultrasensitive reweighted visible stimulated Raman scattering (URV-SRS), a label-free vibrational nanoscopy technique that enables multiplexed detection of metabolic nanostructures within cells. We developed an extensively chirped spectral focusing visible SRS microscope that achieves a detection limit of 4,000 molecules and introduced a self-supervised learning-based denoiser to robustly suppress non-independent SRS noise by over 7.2 dB. The instrumentation-based signal enhancement and computation-based noise suppression synergistically improved the detection sensitivity by 50 times over near-infrared SRS. Leveraging this enhanced sensitivity, we further pushed the resolution to nanoscopic levels by introducing Fourier reweighting to amplify sub-100 nm spatial frequencies previously overwhelmed by noise. Validated by Fourier ring correlation, URV-SRS achieves a lateral resolution of 86 nm in cellular imaging. Here, we applied URV-SRS to elucidate the reprogramming of metabolic nanostructures associated with virus replication in Vero E6 host cells and to compositionally delineate subcellular fatty acid synthesis in engineered Escherichia coli, demonstrating its capability towards nanoscopic spatial metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Planck intermediate results

We present the NPIPE processing pipeline, which produces calibrated frequency maps in temperature and polarization from data from the Planck Low Frequency Instrument (LFI) and High Frequency Instrument (HFI) using high-performance computers. NPIPE represents a natural evolution of previous Planck analysis efforts, and combines some of the most powerful features of the separate LFI and HFI analysis pipelines. For example, following the LFI 2018 processing procedure, NPIPE uses foreground polarization priors during the calibration stage in order to break scanning-induced degeneracies. Similarly, NPIPE employs the HFI 2018 time-domain processing methodology to correct for bandpass mismatch at all frequencies. In addition, NPIPE introduces several improvements, including, but not limited to: inclusion of the 8% of data collected during repointing manoeuvres; smoothing of the LFI reference load data streams; in-flight estimation of detector polarization parameters; and construction of maximally independent detector-set split maps. For component-separation purposes, important improvements include: maps that retain the CMB Solar dipole, allowing for high-precision relative calibration in higher-level analyses; well-defined single-detector maps, allowing for robust CO extraction; and HFI temperature maps between 217 and 857 GHz that are binned into 0'.9 pixels (Nside = 4096), ensuring that the full angular information in the data is represented in the maps even at the highest Planck resolutions. The net effect of these improvements is lower levels of noise and systematics in both frequency and component maps at essentially all angular scales, as well as notably improved internal consistency between the various frequency channels. Based on the NPIPE maps, we present the first estimate of the Solar dipole determined through component separation across all nine Planck frequencies. The amplitude is (3366.6 ± 2.7) μK, consistent with, albeit slightly higher than, earlier estimates. From the large-scale polarization data, we derive an updated estimate of the optical depth of reionization of τ = 0.051 ± 0.006, which appears robust with respect to data and sky cuts. There are 600 complete signal, noise and systematics simulations of the full-frequency and detector-set maps. As a Planck first, these simulations include full time-domain processing of the beam-convolved CMB anisotropies. The release of NPIPE maps and simulations is accompanied with a complete suite of raw and processed time-ordered data and the software, scripts, auxiliary data, and parameter files needed to improve further on the analysis and to run matching simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

3D nanoprinting via focused electron beams

Additive manufacturing of three-dimensional objects on the nanoscale is a very relevant topic but still a highly challenging task. Among the pool of nanofabrication techniques, focused electron beam induced deposition (FEBID) has recently developed from a trial-and-error laboratory method to a predictable 3D nanoprinting technology with unique advantages. This perspective article first introduces the basic principles of 3D-FEBID, followed by an overview of historical developments with a particular emphasis on the last three years. In this work, we examine different aspects of 3D nanoprinting such as the instrumental setup, fundamental growth mechanisms, simulations, computer aided design software solutions, material properties, and application studies. For each aspect, the individual challenges and limitations are reported on. Additionally, we share our outlook about possible solutions and studies currently under investigation. As a perspective, we also address the most urgent milestones of the future and speculate on applications ranging from optics to mechanics, magnetics, and electronics, all of them benefiting from the recently improved 3D FEBID synthesis technique.

77 NANOSCIENCE AND NANOTECHNOLOGY↗