Bond Wire Damage Detection and SOH Estimation of a Dual Pack IGBT Power Module using Active Power Cycling and Reflectometry

High thermal and electrical stress, over a period of time tends to cause deterioration of the health of power electronic switches. A huge fraction of research efforts involves the study of power electronic device reliability and development of novel techniques with higher accuracy in health estimation of such devices. Until today, no other existing techniques can determine the number of lifted bond wires and their locations in a live IGBT module. Through this paper, a new method for online condition monitoring of IGBTs and IGBT modules using SSTDR has been proposed. Unlike traditional methods, this research work concentrates at the gate terminals of the device instead of looking at the collector side. In addition, the RL-equivalent circuit to represent a bond wire has been developed for the DUT and simulated in CST Studio Suite to measure the reflection amplitudes. Both the experimental and simulation results have been compared. These results prove that a single measurement is sufficient to predict the failure of the device instead of looking at the traditional precursor parameter. With only two sets of measurements, it is possible to locate the aged device inside a module and detect the number of bond wire lift offs associated to that device.

30 DIRECT ENERGY CONVERSION↗

Investigation of instrumentation containing an embedded digital device - 257

The U.S. nuclear power industry primarily relies on mature, well-proven analog technology as the basis for most instrumentation and control (I and C) equipment employed in its nuclear power plants (NPPs). However, the market for this legacy instrumentation is very small and availability of such equipment for spare parts or replacement is increasingly limited. Frequently, modern I and C equipment contains embedded digital devices (EDDs), such as microprocessors and programmable logic devices. While the enhanced functional capabilities provided by the digital components offer improved performance, reliability, and maintainability, the corresponding complexity of sophisticated digital implementations also exacerbate concerns about an increased potential for undetected systematic faults, which can lead to common-cause failure (CCF). As part of a research project sponsored by the U.S. Department of Energy, an investigation has been conducted of commercially available instrumentation marketed for nuclear or industrial application. The objective was to identify the usage of EDDs and to determine the types of functional roles allocated to the devices. Examples of the equipment surveyed include smart sensors, sequencers for emergency diesel generators, pumps, valve actuators, motor control centers, breakers, priority logic modules, and uninterruptible power sources. Where sufficient detail was found, an evaluation was performed to ascertain the nature and role of the digital technology implemented in the instrumentation. The information gained through this investigation serves as technical input for defining a classification approach for EDDs based on the functional impact of the device. For example, the role of an EDD can involve any of the following functions: performance monitoring and diagnostics, information extraction and communication, instrument condition monitoring and protection, or execution of core instrument functions. Classifying digital devices according to their role in the operation of the instrumentation in which they are embedded can enable determination of the potential functional impact of failure of that device and contribute to determination of the potential safety significance of a CCF event disabling all instances of that device. This paper will report on the findings of the investigation of instrumentation with EDDs and indicate considerations for the emerging classification approach. The higher-level goal of this effort is to determine whether a graded approach to qualification testing may be possible based on classification. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Temperature Transducers for Online Monitoring of Microstructure Evolution

A critical technology gap exists relative to online condition monitoring (CM) of advanced nuclear plant components for damage accumulation; there are not capable sensors and infrastructure available for the high temperature environment. The sensory system, monitoring methodology, data acquisition, and damage characterization algorithm that comprise a CM system are investigated here. Thus this work supports the DOE mission to develop a fundamental understanding of advanced sensors to improve physical measurement accuracy and reduce uncertainty. The research involves a concept viability assessment, a detailed technology gap analysis, and a technology development roadmap.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Determining appropriate data analytics for transformer health monitoring - 107

Transformers are vital assets for the safe, reliable and cost-effective operation of nuclear power plants. The unexpected failure of a transformer can lead to different consequences ranging from a lack of export capability, with the corresponding economic penalties, to catastrophic failure, with the associated health, safety and economic effects. Condition monitoring techniques examine the health of the transformer periodically, with the aim to identify early indicators of anomalies. However, many transformer failures occur because diagnostic and monitoring models do not identify degraded conditions in time. Therefore, health monitoring is an essential component to transformer life cycle management. Existing tools for transformer health monitoring use traditional dissolved gas analysis based diagnostics techniques. With the advance of prognostics and health management (PHM) applications, we can enhance traditional transformer health monitoring techniques using PHM analytics. The design of an appropriate data analytics system requires a multi-stage design process including: (i) specification of engineering requirements; (ii) characterization of existing data sources and analytics to identify complementary techniques; (iii) development of the functional specification of the analytics suite to formalize its behavior, and finally (iv) deployment, validation, and verification of the functional requirements in the final platform. Accordingly, in this paper we propose a transformer analytics suite which incorporates anomaly detection, diagnostics, and prognostics modules in order to complement existing tools for transformer health monitoring. (authors)

42 ENGINEERING↗

Diagnostic device for monitoring the technical condition of mechanical assemblies

An automatic diagnostic device for monitoring the condition of tractor transmission gears is described. The structural noise spectrum of the gearshift box and rear axle of the tractor were analyzed in a digital computer, by an algorithm based on the multiple correlation method. The optimum assembly of operating frequencies, by use of which the errors in measurement were minimized, was selected from the entire frequency spectrum. Selected frequencies are necessary for choosing the measurement range of the diagnostic device. It turned out that, to obtain a relative error of no more than 2%, it was sufficient to use two filters, vibrating only at the frequencies carrying the maximum data of the mechanical parameter being investigated. The measurement system consists of frequency-selection filters, amplifiers and quadratic detectors, at the outlets of which constant voltages are created, which are proportional to the signal level at the frequencies selected.

Osovskiy, V. I.↗

Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan

The Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan has been developed in accordance with the requirements identified in the: • Interagency Agreement for the Pantex Superfund Site, Article 8.5 Work to be Performed, • Compliance Plan Provision of Hazardous Waste Permit No. 50284, and • Record of Decision for Groundwater, Soil, and Associated Media, Pantex Plant. A Long‐Term Monitoring System Design has been designed to monitor conditions in the perched groundwater including changes in the perched aquifer as a result of implementing the response actions. Monitoring is required for verifying the effectiveness of perched groundwater response actions (i.e., conditions in the perched aquifer are being affected as intended) and for confirming that the perched aquifer and Ogallala Aquifer characterization as defined in the Resource Conservation and Recovery Act Facility Investigation Report and the Corrective Measure Studies/Feasibility Study remains accurate. If monitoring results obtained through the monitoring network identify an unexpected condition or deviation, contingent actions will be considered and implemented as necessary to ensure continued protection of the Ogallala Aquifer and human health and the environment. Potential deviations to expected technology performance may be encountered for each of the four primary response actions that compose the selected remedy for perched groundwater; Playa 1 Pump and Treat System, Southeast Area Pump and Treat System, Southeast Area In‐Situ Bioremediation System (comprised of the Southeast In‐Situ Bioremediation System Original System, Southeast Area In‐Situ Bioremediation System Extension System, Offsite In‐Situ Bioremediation System, Perchlorate/Chromium ISB, Northeast ISB and County Road 8 ISB), and Zone 11 In‐Situ Bioremediation System. Monitoring will also be conducted to determine if there are deviations to the expected characterization, e.g., contaminants not expected as a result of the RCRA Facility Investigation characterization. Deviations to expected conditions in the Ogallala Aquifer could also be encountered if the response actions in the perched groundwater are not performing as expected, i.e., preventing contaminants from migrating to the Ogallala Aquifer. Currently, Pantex has begun investigation of detections of high explosives above groundwater protection standards in wells on the Texas Tech University property and a plume that is moving to the northeast from that area. Due to those detections, this Plan recognizes the fact that future detections in the Ogallala will be focused on first‐ time detections of analytes. After a remedy is determined, this Plan will require modification to address-deviations and contingent actions. This Plan was developed to identify the contingent actions necessary to mitigate impacts resulting from deviations to site conditions or response action performance. The Plan defines the environmental problem being addressed by the response actions, clarifies the expected conditions and objectives of the response actions, and identifies the potential deviations to the response actions (due to site conditions or technology performance) that could be encountered. The deviations were evaluated to determine the likelihood of occurrence, potential impact, and time to respond to avoid impact. The Plan also identifies the monitoring outlined in the Long‐Term Monitoring System Design Report (Consolidated Nuclear Security, 2024) and Sampling Analysis Plan (PanTeXas Deterrence, 2024) that will be used to detect the deviations. Lastly, the Plan specifies the contingent actions that could be implemented in response to the deviations. Because each response focuses on a discrete portion of the perched aquifer and contaminant plume, each response action has a different set of expected conditions, and therefore differing impacts from deviations to the site and technology expectations. As a result, the contingent actions are identified for each response action and potential deviation including specific constituents, location, and conditions. If deviations are encountered that impact the ability of the response action to meet performance objectives, the contingent actions will be focused on ensuring the response action can meet the performance objective. Contingent actions may be implemented as interim actions (ISMs/removal actions) in accordance with the Record of Decision, Interagency Agreement, and Hazardous Waste Permit‐50284, if warranted by the specific circumstances. For deviations to site characterization expected conditions, the contingent action will focus on determination of the source of the deviation, determination of the appropriate response, and evaluation of additional work to be completed. However, if the deviation to characterization impacts the performance of the response action, the contingent action will again focus on ensuring performance objectives can be met. Early source term removals and cleanup actions have been implemented to protect the Ogallala Aquifer. Because of these actions and based on modeling results, the expected conditions in the Ogallala Aquifer are that constituents of concern will not be detected above the Groundwater Protection Standards (GWPSs) nor will they reach potential points of exposure above the GWPS. The primary deviation of concern for the Ogallala is if constituents are detected in the Ogallala Aquifer near or above GWPSs. If it occurs, this change in expected conditions would require further evaluation of site and contaminant characteristics to determine an appropriate course of action. The evaluation would include additional monitoring, source identification, implementation of interim protective measures (if necessary), and delineation of extent. These evaluations are necessary to determine an appropriate response action for the Ogallala. The primary goal of the Plan is to provide for the continued protection of the Ogallala Aquifer and the health of its consumers. In recognition, this Plan presents a flexible and rational approach for making future decisions associated with confirming the change in perched and Ogallala aquifer conditions and identifying a response (technical activities, changes to response actions, regulatory oversight, and public involvement).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New intrinsically smart severe accident instrumentation saves costs and enhances severe accident management - 302

The Severe Accidents (SA) at Fukushima in 2011, identified the need for enhanced I and C to follow the progress of SA. Since SA environments are significantly Beyond DBA conditions, some new advanced Inherently Smart sensors had to be developed and tested. Nuclear plant designers and operators have helped focus the I and C enhancement based upon lessons learned from the Fukushima accidents. The result has been the addition of I and C for direct measurement of SA conditions hydrogen concentration, oxygen concentration, temperature, and pressure that provide unambiguous information for management of Severe Accident scenarios. The benefits are immediate from three important aspects. First, they deliver on the nuclear promise for enhanced safety at reduced costs. These Inherently Smart sensors have no maintenance and replace equipment that has high maintenance costs. Secondly, these sensors provide multiple benefits, such as condition monitoring information all the time and direct measurement of SA conditions if they are needed. Thirdly, and most importantly, simplify operator actions and training for SA. SA scenarios and SA Management can now rely on direct measurements to know such things as, the extent of fuel damage, integrity of the reactor pressure vessel, when corium is on the floor of containment, and conditions upon which to activate the hardened vent. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Online Monitoring to Enable Improved Diagnostics, Prognostics and Maintenance

For both existing and new plant designs there are increasing opportunities and needs for the application of advanced online surveillance, diagnostic and prognostic techniques. These methods can continuously monitor and assess the health of nuclear power plant systems and components. The added effectiveness of such programs has the potential to enable holistic plant management, and minimize exposure to future and unknown risks. The 'NDE & On-line Monitoring' activities within the Advanced Instrumentation, Information and Control Systems (II&CS) Pathway are developing R&D to establish advanced condition monitoring and prognostics technologies to understand and predict future phenomena, derived from plant aging in systems, structures, and components (SSC). This research includes utilization of the enhanced functionality and system condition awareness that becomes available through the application of digital technologies at existing nuclear power plants for online monitoring and prognostics. The current state-of-the-art for on-line monitoring applied to active components (eg pumps, valves, motors) and passive structure (eg core internals, primary piping, pressure vessel, concrete, cables, buried pipes) is being reviewed. This includes looking at the current deployment of systems that monitor reactor noise, acoustic signals and vibration in various forms, leak monitoring, and now increasingly condition-based maintenance (CBM) for active components. The NDE and on-line monitoring projects are designed to look beyond locally monitored CBM. Current trends include centralized plant monitoring of SSC, potential fleet-based CBM and technology that will enable operation and maintenance to be performed with limited on-site staff. Attention is also moving to systems that use online monitoring to permit longer term operation (LTO), including a prognostic or predictive element that estimates a remaining useful life (RUL). Many, if not all, active components (pumps, valves, motors etc.) can be well managed, routinely diagnosed, analyzed and upgraded as needed using a combination of periodic and online CBM. The ability to successfully manage passive systems and structures is seen as the key to LTO, particularly in the USA. New approaches will be demonstrated, including prognostics for passive structures, which is critical to maintaining safety and availability and to reducing operations and maintenance costs for NPP's. To provide proactive on-line monitoring that includes estimates for RUL new projects will include advanced sensors, better understanding of stressors and challenges faced in quantification of uncertainty associated with RUL. This program area will leverage insights from past experience in other industries and seek to demonstrate the feasibility of on-line monitoring and prognostics to support NPP LTO.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of Smart Solid State Sensor Technology in Aerospace Applications

Aerospace applications require a range of chemical sensing technologies to monitor conditions in both space vehicles and aircraft operations. One example is the monitoring of oxygen. For example, monitoring of ambient oxygen (O2) levels is critical to ensuring the health, safety, and performance of humans living and working in space. Oxygen sensors can also be incorporated in detection systems to determine if hazardous leaks are occurring in space propulsion systems and storage facilities. In aeronautic applications, O2 detection has been investigated for fuel tank monitoring. However, as noted elsewhere, O2 is not the only species of interest in aerospace applications with a wide range of species of interest being relevant to understand an environmental or vehicle condition. These include combustion products such as CO, HF, HCN, and HCl, which are related to both the presence of a fire and monitoring of post-fire clean-up operations. This paper discusses the development of an electrochemical cell platform based on a polymer electrolyte, NAFION, and a three-electrode configuration. The approach has been to mature this basic platform for a range of applications and to test this system, combined with "Lick and Stick" electronics, for its viability to monitor an environment related to astronaut crew health and safety applications with an understanding that a broad range of applications can be addressed with a core technology.

Hunter, Gary W.↗

Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan

A Long Term Monitoring System Design has been designed to monitor conditions in the perched groundwater including changes in the perched aquifer as a result of implementing the response actions. Monitoring is required for verifying the effectiveness of perched groundwater response actions (i.e., conditions in the perched aquifer are being affected as intended) and for confirming that the perched aquifer and Ogallala Aquifer characterization as defined in the Resource Conservation and Recovery Act Facility Investigation Report and the Corrective Measure Studies/Feasibility Study remains accurate. If monitoring results obtained through the monitoring network identify an unexpected conditions or deviation, contingent actions will be considered and implemented as necessary to ensure continued protection of the Ogallala Aquifer and human health and the environment.

54 ENVIRONMENTAL SCIENCES↗

A Novel, Low-Cost, Reduced-Sensor Approach for Providing Smart Renote Monitoring and Diagnostics for Packaged Air Conditioners and Heat Pumps

This report describes conceptually an approach to providing automated remote performance and conditioning monitoring and fault detection for air conditioners and heat pumps that shows great promise to reduce the capital and installation costs of such systems from over $1000 per unit to $200 to $400 per unit. The approach relies on non-intrusive electric load monitoring (NIELM) to enable separation of the power use signals of compressors and fans in the air conditioner or heat pump. Then combining information on the power uses and one or two air temperature measurements, changes in energy efficiency and occurrence of major faults would be detected. By decreasing the number of sensors used from between ten and twenty in current diagnostic monitoring systems to three for the envisaged system, the capital cost of the monitoring system hardware and the cost of labor for installation would be decreased significantly. After describing the problem being addressed and the concept for performance monitoring and fault detection in more detail, the report identifies specific conditions and faults that the proposed method would detect, discusses specific needs for successful use of the NIELM approach, and identifies the major elements in the path from concept to a commercialized monitoring and diagnostic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaic Systems

Faults in photovoltaic (PV) systems can seriously affect the efficiency, energy yield, cost, safety, and reliability of PV plants. Condition monitoring of PV plants is, therefore, a very important approach to estimating the health condition of PV modules and power electronics in the system. However, additional hardware for PV system monitoring adds cost to the system's operation; delayed maintenance service also causes additional energy production loss. The Center for Power Electronics Systems (CPES) at the Virginia Polytechnic Institute and State University and Siemens Cooperate Research developed the online impedance measurement for a PV panel self-monitoring and diagnosing technology using the DC-DC converter connected to the panel. Small-signal impedances of a monocrystalline silicon PV panel were modeled and simulated to reflect fault conditions such as the short-circuit, hot-spot, and junction box faults. Modeling and simulation results were validated firstly using a test setup consisting of a solar simulator, a network analyzer, small-signal injectors, and a monocrystalline PV panel rated at 300 W.

14 SOLAR ENERGY↗

Distributed Fiber Optic Sensor for On-Line Monitoring of Coal Gasifier Refractory Health

This report summarizes technical progress on the program “Distributed Fiber Optic Sensor for On-Line Monitoring of Coal Gasifier Refractory Health,” funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The scope of work entails analyses of traveling grating generation technologies in an optical fiber, as well as the interrogation of the gratings to infer a distributed temperature along the fiber, for the purpose of developing a real-time refractory health condition monitoring technology for coal gasifiers. During the project period, which is from 2011-2015, three different sensing principles were studied, including four-wave mixing (FWM), coherent optical time-domain reflectometer (C-OTDR) and Brillouin optical time-domain analysis (BOTDA). By comparing the three methods, the BOTDA was selected for further development into a complete bench-top sensing system for the proposed high-temperature sensing application. Based on the input from Eastman Chemical, the industrial collaborator on this project, a cylindrical furnace was designed and constructed to simulate typical gasifier refractory temperature conditions in the laboratory, and verify the sensor’s capability to fully monitor refractory conditions on the back-side at temperatures up to 1000°C. In the later stages of the project, the sensing system was tested in the simulated environment for its sensing performance and high-temperature survivability. Through theoretical analyses and experimental research on the different factors affecting the sensor performance, a sensor field deployment strategy was proposed for possible future sensor field implementations.

01 COAL, LIGNITE, AND PEAT↗

Analysis of Acoustic Emission Propagation in Metal-to-Metal Adhesively Bonded Joints

Acoustic emission (AE) monitoring shows promise as one of the most effective methods for condition monitoring of adhesively-bonded joints. Previous research has demonstrated its ability to detect, locate and classify adhesive joint failure, though in these studies little attention appears to have been paid to the differences in AE wave propagation through the bonded and un-bonded sections of the specimens tested, or to the effects of the wave modes excited or the propagation distances. This paper details an experimental study conducted on large aluminium sheet specimens to identify the effects of the presence of an adhesive layer on AE wave propagation. Three specimens are considered; a single aluminium sheet, two aluminium sheets placed together without adhesive, and an adhesively-bonded specimen. A pencil lead break (PLB) is used as a simulated AE source, and is applied to the three specimens at varying propagation distances and orientations. The acquired signals are processed using wavelet-transforms to explore time-frequency features, and compared with modified group-velocity curves based on the Rayleigh–Lamb equations to allow identification of wave-modes and edge-reflections. The effects of propagation distance and source orientation are investigated while comparison is made between the three specimens. It is concluded that while the wave propagation modes can be approximated as being constant throughout all three specimens, there is a significant change in the received waveforms due to the attenuation of high-frequency components exhibited by the bonded specimen. These findings may be utilised to provide a deeper understanding of acquired AE data, improving the current abilities to identify, locate and characterise damage mechanisms occurring within adhesive joints, ultimately improving safety in the use of adhesive bonding for critical applications.

42 ENGINEERING↗

Condition sensor system and method

The condition sensor system comprises a condition detector which produces a pulse when a parameter of the monitored condition exceeds a desired threshold. A resettable condition counter counts each pulse. A resettable timer is preset to produce a particular time frame. The counter produces a condition signal when the accumulated number of pulses within the time frame is equal to or greater than a preset count. Control means responsive to the incoming pulses and to the condition signal produce control signals that control utilization devices. After a suitable delay, the last detected pulse simultaneously resets the pulse counter and the timer, and prepares them for sensing another condition occurrence within the time frame. The invention has particular utility in the process of detecting rocking motions of blind people. A controlled, audible, bio-feedback signal is provided which constitutes a warning to the blind person that he is rocking.

Polhemus, J. T.↗

Novel Monitoring Techniques for Characterizing Frictional Interfaces in the Laboratory

A pressure-sensitive film was used to characterize the asperity contacts along a polymethyl methacrylate (PMMA) interface in the laboratory. The film has structural health monitoring (SHM) applications for flanges and other precision fittings and train rail condition monitoring. To calibrate the film, simple spherical indentation tests were performed and validated against a finite element model (FEM) to compare normal stress profiles. Experimental measurements of the normal stress profiles were within -7.7% to 6.6% of the numerical calculations between 12 and 50 MPa asperity normal stress. The film also possessed the capability of quantifying surface roughness, an important parameter when examining wear and attrition in SHM applications. A high definition video camera supplied data for photometric analysis (i.e., the measure of visible light) of asperities along the PMMA-PMMA interface in a direct shear configuration, taking advantage of the transparent nature of the sample material. Normal stress over individual asperities, calculated with the pressure-sensitive film, was compared to the light intensity transmitted through the interface. We found that the luminous intensity transmitted through individual asperities linearly increased 0.05643 ± 0.0012 candelas for an increase of 1 MPa in normal stress between normal stresses ranging from 23 to 33 MPa.

47 OTHER INSTRUMENTATION↗

Defect Length and Profile Influence on Frequency Domain Reflectometry

Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. Although system tests verify cable function under normal loads, demonstration of some cable’s ability to perform under exceptional loads associated with design-basis events is essential to assuring plant integrity. The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program that includes condition monitoring to justify cable performance under normal operation as well as accident conditions. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none are suitable for all cable configurations nor does any single test confirm all features of interest. One particularly promising test that is beginning to be used more and more by utilities is frequency domain reflectometry (FDR). FDR is a nondestructive electrical inspection technique used to detect and localize faults in power and communication system conductors along the length of a cable from a single connection point. FDR detects discontinuities in the electrical impedance that arise due to cable splices or similar changes along the path of the conductor pair. In addition, FDR has the potential to provide sensitivity to insulation degradation by detecting small changes in impedance between the cable conductors being examined. The technique is also sensitive to cable bends, the particular lay of the cable in tray, proximity to other cable, and other factors that bear consideration when interpreting the test results. This paper examines various influences on the FDR approach particularly using FEM modeling methods and focusing on defect length and defect profile.

Cable Inspection, Frequency Domain Reflectometry, ↗

Strategy Developed for Selecting Optimal Sensors for Monitoring Engine Health

Sensor indications during rocket engine operation are the primary means of assessing engine performance and health. Effective selection and location of sensors in the operating engine environment enables accurate real-time condition monitoring and rapid engine controller response to mitigate critical fault conditions. These capabilities are crucial to ensure crew safety and mission success. Effective sensor selection also facilitates postflight condition assessment, which contributes to efficient engine maintenance and reduced operating costs. Under the Next Generation Launch Technology program, the NASA Glenn Research Center, in partnership with Rocketdyne Propulsion and Power, has developed a model-based procedure for systematically selecting an optimal sensor suite for assessing rocket engine system health. This optimization process is termed the systematic sensor selection strategy. Engine health management (EHM) systems generally employ multiple diagnostic procedures including data validation, anomaly detection, fault-isolation, and information fusion. The effectiveness of each diagnostic component is affected by the quality, availability, and compatibility of sensor data. Therefore systematic sensor selection is an enabling technology for EHM. Information in three categories is required by the systematic sensor selection strategy. The first category consists of targeted engine fault information; including the description and estimated risk-reduction factor for each identified fault. Risk-reduction factors are used to define and rank the potential merit of timely fault diagnoses. The second category is composed of candidate sensor information; including type, location, and estimated variance in normal operation. The final category includes the definition of fault scenarios characteristic of each targeted engine fault. These scenarios are defined in terms of engine model hardware parameters. Values of these parameters define engine simulations that generate expected sensor values for targeted fault scenarios. Taken together, this information provides an efficient condensation of the engineering experience and engine flow physics needed for sensor selection. The systematic sensor selection strategy is composed of three primary algorithms. The core of the selection process is a genetic algorithm that iteratively improves a defined quality measure of selected sensor suites. A merit algorithm is employed to compute the quality measure for each test sensor suite presented by the selection process. The quality measure is based on the fidelity of fault detection and the level of fault source discrimination provided by the test sensor suite. An inverse engine model, whose function is to derive hardware performance parameters from sensor data, is an integral part of the merit algorithm. The final component is a statistical evaluation algorithm that characterizes the impact of interference effects, such as control-induced sensor variation and sensor noise, on the probability of fault detection and isolation for optimal and near-optimal sensor suites.

Source record↗