Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminant Diffusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

239 records · Page 14

Microstructural Observations on Advanced Multilayer Protective Coatings for Nuclear Thermal Propulsion

The present research discusses the microstructures of a new multilayered coating concept proposed to solve the “midrange corrosion” problem observed in NbC and ZrC-coated graphite (Gr) nuclear fuels during the NERVA/Rover programs. The concept envisions designing a compliant multilayered coatings architecture to accommodate the thermal expansion mismatch strains between the ZrC outer coating and the Gr/(U,Zr)C fuel matrix along with using a diffusion barrier to minimize carbon and hydrogen diffusion, respectively. Multilayered coatings were deposited on Gr substrates by chemical vapor deposition (CVD). Graphite disks, as well as the inner channels of a 19-hole hexagonal rod 152.4 mm long, were coated by CVD in proof-of concept process demonstration studies. Coated disk specimens were thermally-cycled between ambient and 1900 K for as long as 20 cycles with a 1h hold time at the temperature using both stepped and non-interrupted thermal cycling methods. Detailed cross-sectional microstructural analyses were conducted on the thermally-cycled coated disks. These results showed that the coatings were intact after 20 thermal cycles at 1900 K although the bonding of the overlay Mo coating appeared to be influenced by the oxygen content in the layer. Seven transverse sections were cut along the length from the coated hexagonal rod for microstructural studies. All the nineteen channels were observed to have been coated in all the sections. This paper reports the results of detailed microstructural analyses, compositional line scans and x-ray dot maps conducted on three coated channels from a mid-section of the rod. The measured values of carbon (C) were observed to be exceptionally high in all the specimens, which were attributed to hydrocarbon contamination of the specimen surfaces. It was observed that the oxygen (O) levels were high in all the coating layers even after approximately correcting for the observed high values of C. The source of O contamination of the CVD reactor system was attributed to either the presence of oxychloride impurities in the precursor salts or a pin hole leak in the coating system. It is concluded that high values of O result in poor bonding of the Mo overlay to the ZrC layer. These trials have established that it is possible to deposit multilayered coatings by CVD in 19-hole hexagonal rods 152.4 mm long similar to the NERVA fuel rod design although the quality of the coatings and the uniformity of their thicknesses require further improvement.

Nuclear thermal propulsion, multilayer coatings, m↗

Postlaunch Assessment of the Response Versus Scan Angle for the Thermal Emissive Bands of Visible Infrared Imaging Radiometer Suite On-Board the Suomi National Polar-Orbiting Partnership Satellite

The visible infrared imaging radiometer suite (VIIRS) is a key sensor carried on the Suomi national polar-orbiting partnership (S-NPP) satellite, which was launched in October 2011. It has several on-board calibration components, including a solar diffuser and a solar diffuser stability monitor for the reflective solar bands, a V-groove blackbody for the thermal emissive bands (TEB), and a space view port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to characterize the on-orbit response for all scan angles relative to the calibrator scan angle. Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed to analyze the prelaunch RVS measurement data. A spacecraft level pitch maneuver was scheduled during the first 3 months of intensive Cal/Val. The S-NPP pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of Earth view scan angles, which can be used to characterize the TEB RVS. This study provides our analysis of the pitch maneuver data and assessment of the derived TEB RVS by comparison with prelaunch results. In addition, the stability of the RVS after the first 5 years of operation is examined using observed brightness temperatures (BT) over a clear ocean at various angles of incidence (AOI). To reduce the impact of variations in the BT measurements, the daily overpasses collected over the ocean are screened for cloud contamination, normalized to the results obtained at the blackbody AOI, and averaged each year.

Wu, Aisheng↗

Launch Complex 39B, SWMU 009 Air Sparging System Expansion Implementation Work Plan Kennedy Space Center, Florida

This Implementation Work Plan (IWP) for expansion of the Air Sparging (AS) system at Launch Complex 39B (LC39B), presents the design and coordination specifics to expand the existing AS Interim Measure (IM) at LC39B located at Kennedy Space Center (KSC), Florida. The existing AS system at LC39B was installed in 2017 and included 279 AS wells. LC39B has been designated as Solid Waste Management Unit (SWMU) 009 under the KSC Resource Conservation and Recovery Act (RCRA) Corrective Action Program. Expansion of the AS IM will include installation of an additional five AS wells to depths of approximately 13 and 17 feet below land surface (bls) to remediate contaminated groundwater identified northwest of the launch pad, near the liquid oxygen (LOX) tank. The expansion will target concentrations of cis-1,2-dichloroethene (cDCE) and vinyl chloride (VC) greater than Florida Department of Environmental Protection (FDEP) Natural Attenuation Default Concentrations (NADCs) that were identified during direct push technology (DPT) sampling events between 2019-2022 in shallow intervals between 8 and 16 feet bls. The objective for this expansion is to remediate contaminated groundwater within the treatment zone to below NADCs to support transition to monitored natural attenuation (MNA) through a long-term monitoring (LTM) program. This expansion will treat approximately 0.07-acres of residual groundwater contamination. The IWP design for this expansion will utilize the existing AS system trailer that is already onsite and operating. The five new AS expansion wells will be integrated into the existing Zone Z4 distribution manifold to deliver compressed air to the new AS wells. To deliver airflow, three existing lateral lines will be split in the field at a lateral split junction point (using 2-way or 3-way splits). Each split lateral will supply air to AS wells at the same depth interval to minimize preferential pathways. The trenching layout for the new AS wells was developed to minimize ground disturbance due to the amount of utilities in the area. One new monitoring well will also be installed and added to LC39B’s performance monitoring program to evaluate the effectiveness of the AS system expansion. This well will be sampled on a semi-annual basis for volatile organic compounds, with results evaluated to determine if system adjustments may be required. The main components of this IWP were presented to the KSC Remediation Team (KSCRT) at the October 2022 Meeting (Meeting 2210-M05). DPT delineation data from the LOX area were also presented, which included some inferred boundaries due to physical restrictions of the LOX tank and associated concrete pad and infrastructure. Planned monitoring well sampling in this area will help determine if back-diffusion may be occurring from beneath the pad. Additionally, based on potential petroleum odors and staining identified at two DPT locations during the January 2022 DPT event in the 10-16 feet bls range, a KSCRT action item was assigned during the October 2022 meeting to collect soil samples for petroleum compounds if similar odors or staining are identified during IM implementation. Construction completion and performance monitoring will be incorporated into LC39B’s groundwater monitoring reports, which are currently submitted on an annual basis to FDEP to document operation and maintenance activities and results from the AS IM.

Deborah M. Wilson↗

Flight Testing of the Forward Osmosis Bag for Water Recovery on STS-135

The Forward Osmosis Bag (FOB) is a personal water purification device for recovery of potable liquid from almost any non-potable water source. The FOB experiment was flown as a sortie mission on STS-135/ULF7 using flight-certified materials and a design based on the X-Pack(TradeMark) from Hydration Technology Innovations (Albany, OR). The primary objective was to validate the technology for use under microgravity conditions. The FOB utilizes a difference in solute concentration across a selectively permeable membrane to draw water molecules from the non-potable water while rejecting most chemical and all microbial contaminants contained within. Six FOB devices were tested on STS-135 for their ability to produce a potable liquid permeate from a feed solution containing 500 mL potassium chloride (15 g/L) amended with 0.1% methyl blue dye (w:v) tracer against an osmotic gradient created by addition of 60 mL of concentrate containing the osmolytes fructose and glucose, and 0.01% sodium fluorescein (w:v) tracer. Three FOB devices were physically mixed by hand for 2 minutes by a crewmember after loading to augment membrane wetting for comparison with three unmixed FOB devices. Hydraulic flux rate and rejection of salt and dye in microgravity were determined from a 60-mL sample collected by the crew on orbit after 6 hours. Post-flight analysis of samples collected on orbit demonstrated that the Forward Osmosis Bag achieved expected design specifications in microgravity. The hydraulic flux rate of water across the membrane was reduced approximately 50% in microgravity relative to ground controls that generated an average of 50 mL per hour using the same water and osmolyte solutions. The membrane rejected both potassium and chloride at >92% and methyl blue dye at >99.9%. Physical mixing of the FOB during water recovery did not have any significant effect on either flux rate or rejection of solutes from the water solution. The absence of buoyancy-driven convection in microgravity suggests that mass transport was dominated by diffusion, slowing the rate of permeate production across the membrane. It is possible that a predicted reduction in concentration polarization at the membrane surface that may have acted to increase the rate of permeate production in microgravity was negligible under the described test conditions.

Roberts, Michael S.↗

HaloSat Observations of Heliospheric Solar Wind Charge eXchange

X-ray emission from solar wind charge exchange (SWCX) produced in interplanetary space contaminates every astrophysical observation, regardless of the line-of-sight. Unfortunately, the primary SWCX emission lines also happen to be important diagnostics of astrophysical plasmas. Models of SWCX emission are limited by two main uncertainties: the local solar wind fluxes along the line-of-sight, and the charge exchange cross sections. The He cone, a localized density enhancement of helium neutrals, is the only heliospheric SWCX emission feature that is small enough and bright enough to be observationally isolated from the X-ray background and the broader SWCX emission. HaloSat, an X-ray CubeSat mission, has recently completed two series of specialized observations, near and far from the ecliptic plane, during two Earth transits of the He cone. These observations were used to test the predictions of a SWCX emission model against the emission observed at low ecliptic latitudes, where the solar wind data are monitored, and at high ecliptic latitudes, where the solar wind data are extrapolated. The measured SWCX emission for the set of observations near the ecliptic plane were consistent with the line intensities predicted by the model, but were underpredicted for the set of observations at high ecliptic latitude near the south ecliptic pole. Additionally, high temperature Galactic Halo emission components are reported for both spectral sets.

Solar Wind↗