Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Development of techniques for advanced optical contamination measurement with internal reflection spectroscopy, phase 1, volume 1

The feasibility of monitoring volatile contaminants in a large space simulation chamber using techniques of internal reflection spectroscopy was demonstrated analytically and experimentally. The infrared spectral region was selected as the operational spectral range in order to provide unique identification of the contaminants along with sufficient sensitivity to detect trace contaminant concentrations. It was determined theoretically that a monolayer of the contaminants could be detected and identified using optimized experimental procedures. This ability was verified experimentally. Procedures were developed to correct the attenuated total reflectance spectra for thick sample distortion. However, by using two different element designs the need for such correction can be avoided.

Hayes, J. D.↗

Payload/orbiter contamination control requirement study

A study was conducted to determine and quantify the expected particulate and molecular on-orbit contaminant environment for selected space shuttle payloads as a result of major shuttle orbiter contamination sources. Individual payload susceptibilities to contamination are reviewed. The risk of payload degradation is identified and preliminary recommendations are provided concerning the limiting factors which may depend on operational activities associated with the payload/orbiter interface or upon independent payload functional activities. A basic computer model of the space shuttle orbiter which includes a representative payload configuration is developed. The major orbiter contamination sources, locations, and flux characteristics based upon available data have been defined and modeled.

Bareiss, L. E.↗

Shuttle filter study. Volume 2: Contaminant generation and sensitivity studies

Contaminant generation studies were conducted at the component level using two different methods, radioactive tracer technique and gravimetric analysis test procedure. Both of these were reduced to practice during this program. In the first of these methods, radioactively tagged components typical of those used in spacecraft were studied to determine their contaminant generation characteristics under simulated operating conditions. Because the purpose of the work was: (1) to determine the types and quantities of contaminants generated; and (2) to evaluate improved monitoring and detection schemes, no attempt was made to evaluate or qualify specific components. The components used in this test program were therefore not flight hardware items. Some of them had been used in previous tests; some were obsolete; one was an experimental device. In addition to the component tests, various materials of interest to contaminant and filtration studies were irradiated and evaluated for use as autotracer materials. These included test dusts, plastics, valve seat materials, and bearing cage materials.

Source record↗

Payload/orbiter contamination control requirement study, volume 1, exhibit A

This study is to identify and quantify the expected molecular and particulate on orbit contaminant environment for selected shuttle payloads as a result of major spacelab and shuttle orbiter contaminant sources. This investigation reviews individual payload susceptibilities to contamination, identifies the combined induced environment, identifies the risk of spacelab/payload critical surface(s) degradation, and provides preliminary contamination recommendations. It also establishes limiting factors which may depend upon operational activities associated with the payloads, spacelab, and the shuttle orbiter interface or upon independent payload functional activities.

Bareiss, L. E.↗

Contaminant removal from enclosed atmospheres by regenerable adsorbents

A system for removing contaminants from spacecraft atmospheres was studied, which utilizes catalyst-impregnated activated carbon followed by in-situ regeneration by low-temperature catalytic oxidation of the adsorbed contaminants. Platinum was deposited on activated carbon by liquid phase impregnation with chloroplatinic acid, followed by drying and high-temperature reduction. Results were obtained for the seven selected spacecraft contaminants by means of three experimental test systems. The results indicate that the contaminants could be removed by oxidation with very little loss in adsorptive capacity. The advantages of a catalyst-impregnated carbon for oxidative regeneration are found to be significant enough to warrent its use.

Goldsmith, R. L.↗

Better vacuum by removal of diffusion-pump-oil contaminants

The complex problem of why large space simulation chambers do not realize true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance were identified, and some advances in vacuum distillation-fractionation technology were achieved which resulted in a two-decade-or-more lower ultimate pressure. Data are presented to show the overall or individual contaminating effects of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and for reclaiming contaminated oil by high-vacuum molecular distillation are described. Conceptual self-cleansing designs and operating procedures are proposed for modifying large diffusion pumps into high-efficiency distillation devices. The potential exists for application of these technological advancements to other disciplines, such as medicine, biomedical materials, metallurgy, refining, and chemical (diffusion-enrichment) processing.

Buggele, A. E.↗

Payload/orbiter contamination control assessment support

The development and use is described of a basic contamination mathematical model of the shuttle orbiter which incorporates specific shuttle orbiter configurations and contamination sources. These configurations and sources were evaluated with respect to known shuttle orbiter operational surface characteristics and specific lines-of-sight which encompass the majority of viewing requirements for shuttle payloads. The results of these evaluations are presented as summary tables for each major source. In addition, contamination minimization studies were conducted and recommendations are made, where applicable, to support the shuttle orbiter design and operational planning for those sources which were identified to present a significant contamination threat.

Rantanen, R. O.↗

Test evaluation of potential heat shield contamination of an Outer Planet Probe's atmospheric sampling system

An Outer Planets Probe which retains the charred heatshield during atmospheric descent must deploy a sampling tube through the heatshield to extract atmospheric samples for analysis. Once the sampling tube is deployed, the atmospheric samples ingested must be free of contaminant gases generated by the heatshield. Outgassing products such as methane and water vapor are present in planetary atmospheres and hence, ingestion of such species would result in gas analyzer measurement uncertainties. This paper evaluates the potential for, and design impact of, the extracted atmospheric samples being contaminated by heatshield outgassing products. Flight trajectory data for Jupiter, Saturn and Uranus entries are analyzed to define the conditions resulting in the greatest potential for outgassing products being ingested into the probe's sampling system. An experimental program is defined and described which simulates the key flow field features for a planetary flight in a ground-based test facility. The primary parameters varied in the test include: sampling tube length, injectant mass flow rate and angle of attack. Measured contaminant levels predict the critical sampling tube length for contamination avoidance. Thus, the study demonstrates the compatibility of a retained heatshield concept and high quality atmospheric trace species measurements.

Kessler, W. C.↗

Design, fabrication and test of a trace contaminant control system

A trace contaminant control system was designed, fabricated, and evaluated to determine suitability of the system concept to future manned spacecraft. Two different models were considered. The load model initially required by the contract was based on the Space Station Prototype (SSP) general specifications SVSK HS4655, reflecting a change from a 9 man crew to a 6 man crew of the model developed in previous phases of this effort. Trade studies and a system preliminary design were accomplished based on this contaminant load, including computer analyses to define the optimum system configuration in terms of component arrangements, flow rates and component sizing. At the completion of the preliminary design effort a revised contaminant load model was developed for the SSP. Additional analyses were then conducted to define the impact of this new contaminant load model on the system configuration. A full scale foam-core mock-up with the appropriate SSP system interfaces was also fabricated.

Source record↗

Evaluation of techniques for removal of spacecraft contaminants from activated carbon

Alternative techniques for the regeneration of carbon contaminated with various spacecraft contaminants were evaluated. Four different modes of regeneration were evaluated: (1) thermal desorption via vacuum, (2) thermal desorption via nitrogen purge, (3) in-situ catalytic oxidation of adsorbed contaminants, and (4) in-situ non-catalytic oxidation of adsorbed contaminants.

Mcnulty, K. J.↗

Infrared characterized spacecraft contaminants and related compounds

The limits of the infrared region of the electromagnetic spectrum are discussed, together with an explanation of some of the shortcomings of obtaining data in this range. Similarities and differences in the interest taken by the chemist/spectroscopist and the space/spectroscopist in the IR spectrum are discussed. The chemist uses IR spectra to identify materials and contaminants associated with spacecraft fabrication and testing. The space scientist, using IR spectrometry, can determine atmospheric conditions around planets, stars, and galaxies. He could also determine the temperature profile of the Earth's atmosphere at different altitudes, or even the temperature profile of the Sun. The importance of detecting contamination of spacecraft and the possible results of not taking corrective action are explored. All space experiments contain some contaminants, to a lesser or greater degree; the responsible personnel involved must determine the level of toleration. A collection of IR spectra of known spacecraft contaminants is presented as a guide for cognizant scientists and engineers.

Gross, F. C.↗

Optical contamination - Its prevention in the XUV spectrographs flown by the U.S. Naval Research Laboratory in the Apollo Telescope Mount

During construction and testing of the XUV spectrographs flown in the ATM by the Naval Research Laboratory, many problems associated with optical contamination were encountered. Solving these problems required setting up a contamination prevention program to select the materials used in constructing the instruments and to delineate procedures in assembling, testing, and storing the instruments. A brief description is given of methods of assessing the effects of contamination and of the procedures used to prevent contamination.

Hunter, W. R.↗

Small monopropellant thruster contamination measurement in a high-vacuum low-temperature facility

The contamination that results from the exhaust plume of small thrusters used for attitude control maneuvers can pose severe problems for long-life satellite systems. In order to assess this type of contamination problem, analytical and experimental techniques must be developed. Mass deposition rate measurements of a representative 0.44-N thrust hydrazine thruster were made in a space simulation chamber using five appropriately placed variable-temperature quartz crystal microbalances. The mass deposition rates within the thruster plume were measured while operating the thruster over a wide range of operating parameters, including duty cycles, catalyst bed start temperatures, propellant water variation, as well as thruster aging effects. The contamination measurements were made over a temperature range of 144 to 256 K for all duty cycles. In addition, the nominal duty cycle of 100 msec on and 10 sec off was run at a temperature of 106 K. These data will make possible better prediction of deposition rates of contaminants from thrusters used in satellite systems.

Passamaneck, R. S.↗

Development of a preprototype trace contaminant control system

The steady state contaminant load model based on shuttle equipment and material test programs, and on the current space station studies was revised. An emergency upset contaminant load model based on anticipated emergency upsets that could occur in an operational space station was defined. Control methods for the contaminants generated by the emergency upsets were established by test. Preliminary designs of both steady state and emergency contaminant control systems for the space station application are presented.

Source record↗

Shuttle orbiter - IUS/DSP satellite interface contamination study

The results of a contamination analysis on the Defense Support Program (DSP) satellite during launch and deployment by the Space Transportation System (STS) are presented. Predicted contaminant deposition was also included on critical DSP surfaces during the period soon after launch when the DSP is in the shuttle orbiter bay with the doors closed, the bay doors open, and during initial deployment. Additionally, a six sided box was placed at the spacecraft position to obtain directional contaminant flux information for a general payload while in the bay and during deployment. The analysis included contamination sources from the shuttle orbiter, IUS and cradle, the DSP sensor and the DSP support package.

Rantanen, R. O.↗

Monitoring of particulate contamination and background brightness from IECM based instrumentation

Of particular concern to the astronomical community is the effect of Shuttle Transportation System induced contamination in the form of individual particles and general background on astronomical experiments. In an effort to investigate this problem, two camera/photometers in the Induced Environment Contamination Monitor (IECM) will be used to determine the size and velocity distribution of contaminant particles, their origin, and the extent of sunlit background brightness resulting from spacecraft contamination. The cameras will operate synchronously as a stereo pair to make continuous photographic measurements throughout the missions.

Clifton, K. S.↗

Effects of carbon/graphite fiber contamination on high voltage electrical insulation

The contamination mechanics and resulting failure modes of high voltage electrical insulation due to carbon/graphite fibers were examined. The high voltage insulation vulnerability to carbon/graphite fiber induced failure was evaluated using a contamination system which consisted of a fiber chopper, dispersal chamber, a contamination chamber, and air ducts and suction blower. Tests were conducted to evaluate the effects of fiber length, weathering, and wetness on the insulator's resistance to carbon/graphite fibers. The ability of nuclear, fossil, and hydro power generating stations to maintain normal power generation when the surrounding environment is contaminated by an accidental carbon fiber release was investigated. The vulnerability assessment included only the power plant generating equipment and its associated controls, instrumentation, and auxiliary and support systems.

Garrity, T.↗

Abatement of gaseous and particulate contamination in a space instrument application to a solar telescope

Methods to prevent the ingestion of external contaminants into the instrument and to limit the effect of the self-generated contaminants during ground, launch, orbiting and landing phases of flight were investigated. It is proposed that a positive pressure and purging flow of clean gas inside the instrument be maintained while on the ground, during launch, and for a period of time in orbit. The pressure to be maintained and the required purging flow are examined in terms of the effectiveness in preventing gaseous and particulate contaminants ingestion and the abatement of the self-generated contaminants. Considerations have been given to the venting requirements for the structural integrity of the instrument during launch, the limitations on the volume and the pressure of the purging gas to be carried along in orbit, and the required venting area is established based on the internal volume of the instrument, the allowable pressure differential, and the rate of external pressure change during launch.

Scialdone, J. J.↗