Status Of The National Ignition Campaign And National Ignition Facility Integrated Computer Control System

The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a stadium-sized facility that will contains a 192-beam, 1.8-Megajoule, 500-Terawatt, ultraviolet laser system together with a 10-meter diameter target chamber with room for multiple experimental diagnostics. NIF is the world's largest and most energetic laser experimental system, providing a scientific center to study inertial confinement fusion (ICF) and matter at extreme energy densities and pressures. NIF's laser beams are designed to compress fusion targets to conditions required for thermonuclear burn. NIF is operated by the Integrated Computer Control System (ICCS) in an object-oriented, CORBA-based system distributed among over 1800 frontend processors, embedded controllers and supervisory servers. In the fall of 2010, a set of experiments began with deuterium and tritium filled targets as part of the National Ignition Campaign (NIC). At present, all 192 laser beams routinely fire to target chamber center to conduct fusion and high energy density experiments. During the past year, the control system was expanded to include automation of cryogenic target system and over 20 diagnostic systems to support fusion experiments were deployed and utilized in experiments in the past year. This talk discusses the current status of the NIC and the plan for controls and information systems to support these experiments on the path to ignition.

42 ENGINEERING↗

Steric and Electronic Influence of Excited-State Decay in Cu(I) MLCT Chromophores

For the past eleven years, a dedicated effort in our research group focused on fundamentally advancing the photophysical properties of cuprous bis-phenanthroline-based metal-to-ligand charge transfer (MLCT) excited states. We rationalized that by gaining control over the numerous factors limiting the more widespread use of Cu I MLCT photosensitizers, they would be readily adopted in numerous light-activated applications given the earth-abundance of copper and the extensive library of 1,10-phenanthrolines developed over the last century. Significant progress has been achieved by recognizing valuable structure-property concepts developed by other researchers in tandem with detailed ultrafast and conventional time-scale investigations, in-silico-inspired molecular designs to predict spectroscopic properties, and applying novel synthetic methodologies. Ultimately, we achieved a plateau in exerting cooperative steric influence to control Cu I MLCT excited state decay. This led to combining sterics with π-conjugation and/or inductive electronic effects to further exert control over molecular photophysical properties. The lessons gleaned from our studies of homoleptic complexes were recently extended to heteroleptic bis(phenanthrolines) featuring enhanced visible light absorption properties and long-lived room-temperature photoluminescence. Furthermore, this Account navigates the reader through our intellectual journey of decision-making, molecular and experimental design, and data interpretation in parallel with appropriate background information related to the quantitative characterization of molecular photophysics using Cu I MLCT chromophores as prototypical examples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prediction of Air Mixing From High Sidewall Diffusers in Cooling Mode: Preprint

Computational fluid dynamics modeling was used to evaluate the performance of high sidewall air supply in cooling mode. The research focused on the design, placement, and operation of air supply diffusers located high on a sidewall and return grilles located near the floor on the same sidewall. Parameters of the study are the supply velocity, supply temperature, diffuser dimensions and roomdimensions. Thermal loads characteristic of high performance homes were applied at the walls and room temperature was controlled via a thermostat. The results are intended to provide information to guide the selection of high sidewall supply diffusers to provide proper room mixing for cooling of high performance homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing cyber tools for monitoring power grid systems: what information is available and who needs it?

Abstract—The power grid is a complex, interconnected system that requires the coordination of multiple entities ensure the reliability of the system. System operators must be aware of the impacts of various natural and man-made contingencies through telemetry from their control systems, and they must also be aware of the integrity and availability of the cyber assets on their systems. A team of researchers from PNNL and INL have conducted a series of observations and interviews at power utilities to identify what information needs to be available for both control room dispatchers and cyber security analysts to maintain situation awareness of cyber security to effectively monitor the cyber assets on utility control systems. The researchers interviewed and observed control room dispatchers and spoke with regional control system engineers and cyber security analysts to define the context in which such information would be used. The results of this work will inform the design of a tool that will enhance cyber situation awareness and help facilitate effective communication between the various roles and organizations with utility and other regional authorities during contingencies. Index Terms—

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Savings Shapes Measure Documentation: Demand Control Ventilation

This documentation focuses on a single end-use savings shape measure - Demand Control Ventilation (DCV). DCV can save energy by reducing the rate at which outdoor air (OA) is delivered during periods of less-than-design occupancy. This measure will enable DCV for air loops using applicable HVAC system types (all except dedicated outdoor air systems [DOAS], packaged systems, or that have an energy recovery ventilator [ERV]) and serving applicable space types (all except kitchens, dining areas, patient spaces, mechanical rooms, stairwells and corridors, or high exhaust space types) using model occupancy schedules to control the DCV. The measure is applicable to 72.7% of the stock floor area. As office buildings outside of California in ComStock are modeled using a single, whole-building space type, DCV is not applied to these building types. The DCV measure demonstrates 2.6% total site energy savings (119 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lessons Learned from Performing a Human Factors Engineering Validation of an Upgraded Digital Control System in a Nuclear Power Plant Control Room

The United States' fleet of nuclear power plants (NPPs) have exceeded their original 40-year licenses and many are seeking license renewals to continue operations into the future. To support continued operation the Department of Energy's (DOE) Light Water Reactor Sustainability Program (LWRS) provides support for utilities to maintain and upgrade their power production capabilities. Control room modernization is one focus area, which aims to modernization the analog control rooms with digital controls and human-system interfaces (HSIs). The Turbine Control System (TCS) is a non-safety related system undergoing modernization efforts at multiple plants and utilities. Considerable human factors research efforts, comprised of expert reviews and operator in the loop studies were performed to develop human factors compliant and usable TCS. This report documents the final phase of the human factors engineering program used to design and validate the new digital TCS. According to the NUREG-0711 review guide, one of the last steps of human factors engineering program prior to implementation is human factors validation. This report details the method, results and conclusions from the human factors validation study of a collaborating utilities TCS slated to be implemented in one of their plants. One control room team consisting of two control room supervisors and two reactor operators participated in the validation. All team members had participated in the BNP TCS training program foregoing the TCS validation. Performance measures included task performance, situation awareness and workload, expert observation of any negative influences of human-system interface features on control room team performance, and interviews with the participating operators. Performance criteria were based on the performance scores and the topics identified by interviews and expert observations. The results showed that the crew using the new TCS clearly could achieve their overall objectives in the test scenarios with sufficient situation awareness. The new TCS compared to the old system provided clear improvements of the control room work regarding shell and chest warming and regarding valve and other system testing. However, a number of Human Engineering Discrepancies (HEDs) were identified. HEDs were prioritized (level 1, 2 or 3) according to potential safety, plant availability, operability or personnel performance consequences. Since no priority 1 HEDs were identified there is no HFE reason not to continue implementation of the TCS. The TCS upgrade is acceptable if the Priority 2 HEDs are resolved and dispositioned in a satisfactory way. Priority 3 HEDs should be noted and considered for future modifications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Processing Parameter Control of Lifetime-Limiting Failure Mechanisms in Al-Si Cast Alloys at Room and Elevated Temperatures

Aluminum-silicon cast alloys widely used throughout the transportation sector, A356, 319, and A390, have been studied with respect to chemical compositions and processing parameters that control the resultant mechanical behavior. First, the development of strengthening mechanisms is discussed in terms of the role that alloying elements, solidification behavior, and thermal treatments play. Based on this understanding, an extensive matrix of material conditions was developed and characterized in order to provide practical guidelines for alloy development. In order to provide an understanding of lifetime-limiting failure mechanisms, fatigue crack growth and hot compressive dwell behaviors were further investigated. Fatigue crack growth tests were conducted for all alloys at R = 0.1 and room temperature, and creep–fatigue of 319 was studied at R = − 1.5 and 250 °C. The role of processing parameters in controlling the mechanical properties is identified and discussed, and recommendations for optimized design are made.

36 MATERIALS SCIENCE↗

Role of Fast Dynamics in Conductivity of Polymerized Ionic Liquids

Polymerized ionic liquids (PolyILs) are promising candidates for a broad range of technologies. However, the relatively low conductivity of PolyILs at room temperature has strongly limited their applications. In this work, we provide new insights into the roles of various microscopic parameters controlling ion transport in these polymers, which are crucial for their rational design and practical applications. Using broadband dielectric spectroscopy and neutron and light scattering techniques, we found a clear connection between the activation energy for conductivity, fast dynamics, and high-frequency shear modulus in PolyILs at their glass transition temperature (T g ). In particular, our analysis reveals a correlation between conductivity and the amplitude of fast picosecond fluctuations at T g , suggesting the possible involvement of fast dynamics in lowering the energy barrier for ion conductivity. We also demonstrate that both the activation energy for ion transport and the amplitude of the fast fluctuations depend on the high-frequency shear moduli of PolyILs, thus identifying a practically important parameter for tuning conductivity. Finally, the parameters recognized in this work and their connection to the ionic conductivity of PolyILs set the stage for a deeper understanding of the mechanism of ion transport in PolyILs in the glassy state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dyes in dye aggregate systems—engineering J, K, and dye packing

The present disclosure is directed to designing dyes and methods to alter the parameters controlling the dipole-dipole coupling of dyes bound to a nucleotide oligomer architecture, which are used to propagate excitons for use in next generation room temperature quantum information systems. The disclosed dyes and methods are directed to changing the dye stability, symmetry, overlap, and steric hindrance of the dyes to fine tune aggregate systems.

Knowlton, William B.↗

Dynamic Human-in-the-Loop Simulated Nuclear Power Plant Thermal Dispatch System Demonstration and Evaluation Study

An Idaho National Laboratory research team performed a human-in-the-loop study with two formerly licensed retired operators to evaluate thermal power dispatch operations supported by the modified GSE Systems GPWR plant simulator. Virtual representations of the analog control panels were presented on touch-screen bays configured to mimic the control room layout in the newly renovated Human Systems Simulation Laboratory. The operators performed 15 scenarios covering normal evolutions to transition the plant from full turbine operation to joint turbine and thermal power dispatch operations in addition to transient response scenarios induced with simulated faults to evaluate the impact of thermal power dispatch system on operator and plant responses. A prototype human-system interface (HSI) was developed and displayed in tandem with the virtual analog panels to support the operators executing the procedurally drive evolutions and transient responses. An interdisciplinary team of operations experts, nuclear engineers, and human factors experts observed the operators performing the scenarios to evaluate the operations. Only a preliminary analysis of the results has been performed. The full analysis will be shared in a milestone report scheduled for release at the end of September; however, some high-level conclusions were readily available. Two high level findings for the system design were captured in the study. The manual control supported by the HSI to transition from standard operations to thermal power dispatch operation imposed a considerable amount of workload on the operators due to tedious manual valve manipulations and system monitoring required to verify their intended effect. An additional operator would be required in the control room to support the daily evolution. Automatic control for the transition was deemed a requirement for plant adoption without imposing additional staffing costs. The second finding was the necessity for an automatic thermal power dispatch system trip isolation function linked to a turbine and reactor trip signal. The operators completed scenarios with automatic isolation functionality and manually required actuation of the thermal power dispatch system. The operator response was sufficiently slower in the manual trip condition, such that operators were unable to manually actuate key post trip safety functions an indicate a degraded control capability that should be avoided. With an automatic trip signal little to no impact of the thermal power dispatch system was identified on the primary plant response and therefore the system could be readily and safely adopted. Together these two findings represent the need to support the adoption of thermal power dispatch capability into existing operations by leveraging automation to augment any additional operator tasking required to control and monitor an additional system beyond existing operations.

99 GENERAL AND MISCELLANEOUS↗

A Section 106 Evaluation of Building CP-1, Area 6, Nevada National Security Site, Nye County, Nevada

On December 17, 2015, the National Nuclear Security Administration Nevada Field Office (NNSA/NFO) vacated Building CP-1 (Building 06-CP-1) on the Nevada National Security Site (NNSS) in Nye County, Nevada. Starting in 1951, nearly all nuclear tests during the Cold War were controlled from this building on the facility, known as the Nevada Test Site for most of its years of operation. The test site was renamed the NNSS in 2010. CP-1 was the command and control center where decisions about NNSS activities were sought and made; where authorization for movements about the areas forward (north) of Mercury base camp were coordinated, granted or declined, and monitored; and where problems and emergencies in the forward areas were communicated and relayed to the appropriate agencies for solution. Some of the testing duties for the Control Point included the timing and firing of nuclear tests, air operations, security, communications, weather monitoring, and radiation safety. During tests, communications were maintained through various channels to receive and pass instructions or information to the numerous testing operations, to Washington, D.C., the national laboratories, and overhead aircraft monitoring the tests. At one time, the Security Control Center, a Class A Weather Station, and the Radiation Safety Headquarters were located in CP-1, which also contained a cafeteria, a dining area, and bunk rooms. This survey was prompted by recognition that closure of the building in place creates a situation where CP-1 is vulnerable to decay in its present and unused condition. Activities at CP-1 have been reduced gradually over time since the end of nuclear testing in 1992. The Area of Potential Effects (APE) was determined by NNSA/NFO to be a two-acre area historically considered the space directly associated with CP-1 and available to CP-1 personnel for use. The APE is bounded on the south by an unnamed main paved road into the guarded Control Point area, on the west by the edge of the parking lot for adjacent Building CP-9, on the east by the edge of the bladed cut-and-fill terrace for CP-1, and on the north by a barbed wire security fence (Figure 2). All of this lot is either bladed or covered with asphalt. Contained within the lot are eight Accessary Resources (AR) which are much more closely aligned with CP-1 than with adjacent buildings. AR are defined by the Nevada State Historic Preservation Office (SHPO) (2013) as “…related but subordinate to the principal building. Accessory resources would not exist were it not for the principal resource.” The Visual APE was determined by NNSA/NFO to be the same as the APE used for intensive survey because no exterior modifications to the resource are anticipated. The APE is located in Section 34 T11S R53E MDBM (projected) within the NNSS base called the Control Point in Area 6. It is on the 1986 Yucca Lake USGS 7.5 min. series topographic quadrangle. The Desert Research Institute (DRI) surveyed the APE with the assistance of National Security Technologies, LLC (NSTec), resulting in recordation and evaluation of CP-1 (SHPO Resource Number B14490) and eight accessory resources (AR1-AR8). This recording of CP-1 was done in three sessions. Copies of the building form and report are on file at Nevada Cultural Resources Information System (NVCRIS), DRI, and with the NNSA/NFO, Las Vegas, Nevada. Control Point refers to the support facilities of which Building CP-1, with its 126 rooms, is the most important part (Campbell et al. 1983:165). CP-1 refers to the entire building but it also is the designation for the first phase of construction, i.e. the original building. There were three major subsequent phases of additions to the building. The first two were called CP-1A (the east wing) and CP-1B (the west wing with the new War Room). A final phase filled in the hyphen between CP-1 and CP-1B with a Field Office. For convenience this last phase is called CP-1C in this report. Hence, CP-1 can refer either the entire building or to the first phase of the building exclusive of additions. The context makes clear which of the two meanings is intended in the various sections of this report. There were also two minor expansions consisting of a small battery room and a shelter for an emergency exit.

54 ENVIRONMENTAL SCIENCES↗

Multifunctional BiFeO{sub 3}/TiO{sub 2} nano-heterostructure: Photo-ferroelectricity, rectifying transport, and nonvolatile resistive switching property

Multifunctional BiFeO{sub 3} nanostructure anchored TiO{sub 2} nanotubes are fabricated by coupling wet chemical and electrochemical routes. BiFeO{sub 3}/TiO{sub 2} nano-heterostructure exhibits white-light-induced ferroelectricity at room temperature. Studies reveal that the photogenerated electrons trapped at the domain/grain boundaries tune the ferroelectric polarization in BiFeO{sub 3} nanostructures. The photon controlled saturation and remnant polarization opens up the possibility to design ferroelectric devices based on BiFeO{sub 3.} The nano-heterostructure also exhibits substantial photovoltaic effect and rectifying characteristics. Photovoltaic property is found to be correlated with the ferroelectric polarization. Furthermore, the nonvolatile resistive switching in BiFeO{sub 3}/TiO{sub 2} nano-heterostructure has been studied, which demonstrates that the observed resistive switching is most likely caused by the electric-field-induced carrier injection/migration and trapping/detrapping process at the hetero-interfaces. Therefore, BiFeO{sub 3}/TiO{sub 2} nano-heterostructure coupled with logic, photovoltaics and memory characteristics holds promises for long-term technological applications in nanoelectronics devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of E{sub h}-pH diagram for room temperature precipitation of zinc stannate microcubes in an aqueous media

Graphical abstract: - Highlights: • One pot aqueous synthesis of zinc stannate (ZnSnO{sub 3}) particles at low temperature. • Synthesis designed with the assistance of potential-pH diagram. • ZnSnO{sub 3} estimated to be stable between pH 8 and 12 was used for synthesis of the particles. • ZnSnO{sub 3}·3H{sub 2}O were formed during the precipitation of zinc stannate. - Abstract: Potential-pH diagram assisted-design for controlled precipitation is an attractive method to obtain engineered binary and ternary oxide particles. Aqueous synthesis conditions of zinc stannate (ZnSnO{sub 3}) particles at low temperature were formulated with the assistance of potential-pH diagram. The pH of a solution containing stoichiometric amounts of Zn{sup 2+} and Sn{sup 4+} was controlled for the precipitation in a one pot synthesis step at room temperature (25 °C). The effect of the concentration of the reactants on the particle size was studied by varying the concentration of the precursor (Zn{sup 2+} + Sn{sup 4+}) solution. Scanning electron micrographs show that the particles are monodispersed micron sized cubes formed by the self-organization of nano-sized crystallites. The obtained microcubes characterized by X-ray Diffraction and thermo gravimetric analysis (TGA) show that the particles are in ZnSnO{sub 3}·3H{sub 2}O form.

36 MATERIALS SCIENCE↗

Operating displays - new concept: high performance displays - 118

New control rooms in Nuclear Power Plants using digital Distributed Control System (DCS) operated with software displays, are providing thousands of signals to the operating crew. When an event happens, the Flood of information provided to operators could obscure the initiator event increasing the operator response time, work load and complicating the selection of the actions to be performed. There are some initiatives that are trying to minimize the 'avalanche effect' as the alarm engineering filtering and prioritization or diagnostic displays. Likewise, new control rooms are lost the availability to know the plant status just with a quick glance to the panel indicators. Regarding Small Modular Reactors, where in some cases four operators should monitor and control twelve reactors, these problems are even more significant. The challenge is to find a solution, based on current digital systems, that supply information to operators in order to prevent events and take early actions to minimize or avoid any unexpected incident. In order to minimize human errors, Tecnatom has developed a specific set of displays, called 'High Performance Displays' (HPD) based on objectives, work environment limitation, and non-anticipated events. These displays are being design following the HFE standards: applying the NUREG-0711 elements to identify the information that they have to content and the NUREG-0700 to design the interface. The function of these displays is monitoring the plant situation in a way that the operators are able to recognize any potential event at a simple glance but controlling thousands of signals through pattern recognition, symmetries, regular polygons and colors. The objective of the HPD is to provide an integrated function minimizing the tunnel effect and reduce the workload during the diagnosis phase. Moreover, HPD enhance operators to take the right actions to anticipate the response to any event, even avoiding it, if possible This paper analyzes how HPD's have been design as well as presents the results of a preliminary validation of their capabilities. The preliminary validation is a reduce validation in a full scope simulator running two representative scenarios of abnormal and emergency operation. The analysis is focused on the first stage of the event, i.e. the detection phase, HPD's have been installed in a generic full scope simulator of a nuclear power plant, digital controlled. Both scenarios have been performed by two different operator crews. The first operator shift has worked with the conventional human machine interface, that is, displays similar to the ones currently installed in existing nuclear power plant with digital control. The second crew, reproduce the same scenarios but with HPD available. The studio collects preliminary data in order to compare results, draw lesson learned from the experience to improve HPD design, and find solutions in terms of reducing human errors, human workload, and increase the availability of the plant. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Room Temperature Electrorefining of Rare Earth Metals from End-of-use Nd-Fe-B Magnets

Recovering rare earth elements (REE) from used permanent magnets, which contains about 30 wt.% of rare earth elements, has been persistent technological challenge. Current recycling methods relies on pyrometallurgical or hydrometallurgical processes which are energy- and chemical- intensive and not economically and environmentally viable for rare earth containing magnets. Enabling efficient and simplistic recovery and refining of REEs contained in End-of-Use (EoU) products, such as Neodymium-Iron-Boron (Nd-Fe-B) based magnets will play an important and complementary role in the total supply of REEs in the future. We designed a new electrochemical method and demonstrated a room temperature one-pot process that concurrently separates and electroplates REE from commercial Nd-Fe-B magnets. By establishing selective oxidation and reductive potential as electrochemical control parameter along with electrochemically compatible non-aqueous electrolyte system, we demonstrated selective electroleaching of lanthanides (Nd and Preseodymium (Pr)) from anode and concurrent plating as alloy at Pt cathode. The morphological and chemical evolution of the Nd-Fe-B magnets during electroleaching reveals the electrochemical stimuli and rate of dissolution depends on microstructural complexities of the Nd-Fe-B magnet. The concomitant electroplating process leads to Nd-Pr based alloy which can be used as raw metallic alloy for manufacturing new permanent magnet and other devices. Our study demonstrates a scalable separation and refining methodology, based on widely available organic electrolyte system and without any consumptive chemical use, for selective lanthanide recovery from waste magnets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Operations for Nuclear: Work Reduction Opportunity Demonstration Strategy

EXECUTIVE SUMMARY The Light Water Reactor Sustainability Program Plant Modernization Pathway has been working with industry for a number of years to leverage digital technology to extend the life and improve the performance of the existing fleet through modernized technologies and improved processes for plant operation and power generation. This includes development of modernization solutions to improve reliability and economic performance while addressing US nuclear industry’s aging and obsolescence challenges. The objective of these efforts is to deliver a sustainable business model that enables US nuclear industry to remain competitive. Digital Infrastructure (DI) research has established a technical foundation for these efforts. This effort began with technical analysis and support for a safety-related instrumentation and control (I&C) pilot upgrade being performed at Constellation Energy Generation’s Limerick Nuclear Plant. The following publicly available reports were produced as part of this effort. • INL/EXT-20-61079, Vendor-Independent Design Requirements for a Boiling Water Reactor Safety System Upgrade [1] • INL/EXT-20-59371, Business Case Analysis for Digital Safety-Related Instrumentation & Control System Modernizations [2] • INL/EXT-20-59809, “Safety-Related Instrumentation and Control Pilot Upgrade: Initial Scoping Phase Implementation Report and Lessons Learned [3] • INL/RPT-23-72105, Safety-Related Instrumentation and Control Upgrade: Conceptual – Detailed Design Phase Report and Lessons Learned [4]

99 GENERAL AND MISCELLANEOUS↗

Design of the Electromagnetic Particle Injector (EPI) for Tokamak Deployment

Both predicting and controlling disruptions are critical and urgent issues for ITER as some disruptions with a short warning time may be unavoidable. For these cases, a rapid response disruption mitigation system (DMS) referred to as the electromagnetic particle injector (EPI) is being developed. The primary advantages of the EPI are its fast response time and high velocity, which have been demonstrated in offline experiments (Raman et al., 2021). The EPI is capable of accelerating a metallic sabot electromagnetically using a rail gun to the required velocities ( > 2 km/s) within 2 ms. Two high-field racetrack magnets able to generate fields over 2 T are positioned above and below the rails to permit high velocity at low rail currents, a requirement to minimize electrode erosion. At the end of the acceleration phase, a sabot capture mechanism retains the spent sabot inside the vacuum chamber that houses the EPI. At this point, it releases well-defined microspheres, or a shell pellet, of a radiative payload into the disrupting plasma. A remotely operated sabot loading system positioned behind the injector contains several pre-equipped sabots that can be loaded by an operator from the tokamak control room. The injector is interfaced to the tokamak through a guide tube attached to the front of the EPI vacuum chamber. Finally, the advantages of the EPI system over other DMSs under consideration are described in conjunction with the details of an EPI system designed for near-term test on an existing large tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Virtualized Computing Platform For Fusion Control Systems

The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a stadium-sized facility that contains a 192-beam, 1.8-Megajoule, 500-Terawatt, ultraviolet laser system together with a 10-meter diameter target chamber with room for multiple experimental diagnostics. NIF is the world's largest and most energetic laser experimental system, providing a scientific center to study inertial confinement fusion (ICF) and matter at extreme energy densities and pressures. NIF's laser beams are designed to compress fusion targets to conditions required for thermonuclear burn, liberating more energy than required to initiate the fusion reactions. 2,500 servers, 400 network devices and 700 terabytes of networked attached storage provide the foundation for NIF's Integrated Computer Control System (ICCS) and Experimental Data Archive. This talk discusses the rationale & benefits for server virtualization in the context of an operational experimental facility, the requirements discovery process used by the NIF teams to establish evaluation criteria for virtualization alternatives, the processes and procedures defined to enable virtualization of servers in a timeframe that did not delay the execution of experimental campaigns and the lessons the NIF teams learned along the way. The virtualization architecture ultimately selected for ICCS is based on the Open Source Xen computing platform and 802.1Q open networking standards. The specific server and network configurations needed to ensure performance and high availability of the control system infrastructure will be discussed.