Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Effects of high count rate and gain shift on isotope identification algorithms

Spectroscopic gamma-ray detectors are used for many research, industrial, and homeland- security applications. Thallium-doped sodium iodide, (NaI(Tl)), scintillation crystals coupled to photomultiplier tubes provide medium-resolution spectral data about the surrounding environment. NaI(Tl)-based detectors, paired with spectral identification algorithms, are often effective for identifying gamma-ray sources by isotope. However, intrinsic limitations for NaI(Tl) systems exist, including gain shifts and spectral marring (e.g., loss of resolution and count-rate saturation) at high count rates. These effects are hardware dependent and have strong effects on the radioisotopic identification capability of NaI(Tl)-based systems. In this work, the effects of high count rate on the response of isotope-identification algorithms are explored. It is shown that a small gain shift of a few tens of keV is sufficient to disturb identification. The onset of this and other spectral effects is estimated for NaI(Tl) crystals, and a mechanism for mitigating these effects by estimating and correcting for them is implemented and evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of deadtime and electronic transients on the predelay bias in neutron coincidence counting

In neutron coincidence counting using the shift register autocorrelation technique, a predelay is inserted before the opening of the (R+A)-gate. Operationally the purpose of the predelay is to ensure that the (R+A)- and A-gates have matched effectiveness, otherwise a bias will result when the difference between the gates is used to calculate the accidentals corrected net reals coincidence rate. The necessity for the predelay was established experimentally in the early practical development and deployment of the coincidence counting method. The choice of predelay for a given detection system is usually made experimentally, but even today long standing traditional values (e.g., 4.5 µs) are often used. This, at least in part, reflects the fact that a deep understanding of why a finite predelay setting is needed and how to control the underlying influences has not been fully worked out. We attempt, in this paper, to gain some insight into the problem. One aspect we consider is the slowing down, thermalization, and diffusion of neutrons in the detector moderator. The other is the influence of deadtime and electronic transients. These may be classified as non-ideal detector behaviors because they are not included in the conventional model used to interpret measurement data. From improved understanding of the effect of deadtime and electronic transients on the predelay bias in neutron coincidence counting, the performance of both future and current coincidence counters may be improved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Operating a triple stack microchannel plate-phosphor assembly for single particle counting in the 12-300 K temperature range

An assembly consisting of a stack of three microchannel plates (MCPs) and a phosphor screen anode has been operated over the temperature range from 300 to 12 K. We report on measurements at 6.4 kHz (using an alpha source) and with dark counts only (15 Hz). Without any particle source, the MCP bias current decreased by a factor of 2.1x10{sup 3} when the temperature was lowered from 300 to 12 K. Using the alpha source, and a photomultiplier tube (PMT) to monitor the phosphor screen anode, we first observed an increase in the decay time of the phosphor from 12 to 45 {mu}s when the temperature was decreased from 300 to 100 K while the decay time then decreased and reached a value of 5 {mu}s at 12 K. The pulse height distribution from the PMT was measured between 300 and 12 K and shows a spectrum typical for a MCP phosphor setup at 300 K and 12 K but is strongly degraded for intermediate temperatures. We conclude that the present MCP-phosphor detector assembly is well suited for position-sensitive particle counting operation at temperatures down to at least 12 K even for count rates beyond 6 kHz. This result is crucial and an important part of ongoing developments of new instrumentation for investigations of, e.g., interactions involving complex molecular ions with internal quantum state control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of a digital pileup resolving method to high count rate neutron measurements

The possibility of working in high count rate conditions is an important issue for neutron measurements applied to fusion experiments in order to extend the measurement dynamic range and time resolution. One of the main issues of high count rate operation is the overlapping of closely spaced events (pileup) that produces a distortion in their amplitude and therefore in the pulse height spectra. The usual way to deal with such pileup events using standard analog electronics is to reject them in the energy analysis process. Thanks to digital acquisition techniques, the waveforms of pileup events can be recorded and elaborated in order to reconstruct the contributing original single events. This work presents the results of the application of a pileup resolving method for the reconstruction and analysis of overlapping events to pulses acquired digitally from a NE213 liquid scintillator detector. The measurements have been carried out at the PTB accelerator facility with 14 MeV neutrons at total count rates over 400 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Activated Au foils by 2{pi}{beta}+2{pi}{beta}-{gamma} Coincidence Counting and EGS5 Monte Carlo Calculation

Neutron activation analysis using Au foil is a common and important method for measurement of thermal neutron fluence. To determine the activity of Au foil experimentally, Kawada et al. proposed 2{pi}{beta}+2{pi}{beta}-{gamma} coincidence counting. This method is based on 4{pi}{beta}-{gamma} coincidence counting but a 4{pi}{beta} detector is divided into two 2{pi}{beta} detectors those are independently operated in the method. In this research the correction factors in 2{pi}{beta}+2{pi}{beta}-{gamma} coincidence counting were obtained by measurement and simulation. The activities obtained by these correction factors were in good agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of anomalous reactor activity using antineutrino count evolution over the course of a reactor cycle

This paper analyzes the sensitivity of antineutrino count rate measurements to changes in the fissile content of civil power reactors. Such measurements may be useful in IAEA reactor safeguards applications. We introduce a hypothesis testing procedure to identify statistically significant differences between the antineutrino count rate evolution of a standard 'baseline' fuel cycle and that of an anomalous cycle, in which plutonium is removed and replaced with an equivalent fissile worth of uranium. The test would allow an inspector to detect anomalous reactor activity, or to positively confirm that the reactor is operating in a manner consistent with its declared fuel inventory and power level. We show that with a reasonable choice of detector parameters, the test can detect replacement of 82 kg of plutonium in 90 days with 95% probability, while controlling the false positive rate at 5%. We show that some improvement on this level of sensitivity may be obtained by various means, including use of the method in conjunction with existing reactor safeguards methods. We also identify a necessary and sufficient minimum daily antineutrino count rate and a maximum tolerable background rate to achieve the quoted sensitivity, and list examples of detectors in which such rates have been attained.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Note: Simple calibration of the counting-rate dependence of the timing shift of single photon avalanche diodes by photon interval analysis

The counting-rate dependence of the temporal response of single photon avalanche diodes (SPADs) is a critical issue for the accurate determination of the fluorescence lifetime. In this study, the response of SPADs was examined with analyzing the time interval of the detected photons. The results clearly show that the shift of the detection timing causes the counting-rate dependence of the temporal response, and this timing shift is solely determined by the time interval from the preceding photon. We demonstrate that this timing instability is readily calibrated by utilizing the macrotime data taken with the time-tag mode that is implemented in the time-correlated single photon counting modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High quantum efficiency and low dark count rate in multi-layer superconducting nanowire single-photon detectors

In this paper, we theoretically show that a multi-layer superconducting nanowire single-photon detector (SNSPD) is capable of approaching characteristics of an ideal SNSPD in terms of the quantum efficiency, dark count, and band-width. A multi-layer structure improves the performance in two ways. First, the potential barrier for thermally activated vortex crossing, which is the major source of dark counts and the reduction of the critical current in SNSPDs is elevated. In a multi-layer SNSPD, a vortex is made of 2D-pancake vortices that form a stack. It will be shown that the stack of pancake vortices effectively experiences a larger potential barrier compared to a vortex in a single-layer SNSPD. This leads to an increase in the experimental critical current as well as significant decrease in the dark count rate. In consequence, an increase in the quantum efficiency for photons of the same energy or an increase in the sensitivity to photons of lower energy is achieved. Second, a multi-layer structure improves the efficiency of single-photon absorption by increasing the effective optical thickness without compromising the single-photon sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of two-stage system for neutron measurement aiming at increase in count rate at Japan Atomic Energy Agency-Fusion Neutronics Source

In order to increase the count rate capability of a neutron detection system as a whole, we propose a multi-stage neutron detection system. Experiments to test the effectiveness of this concept were carried out on Fusion Neutronics Source. Comparing four configurations of alignment, it was found that the influence of an anterior stage on a posterior stage was negligible for the pulse height distribution. The two-stage system using 25 mm thickness scintillator was about 1.65 times the count rate capability of a single detector system for d-D neutrons and was about 1.8 times the count rate capability for d-T neutrons. The results suggested that the concept of a multi-stage detection system will work in practice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compensated gadolinium-loaded plastic scintillators for thermal neutron detection (and counting)

Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by gadolinium-155 and gadolinium-157, alternative treatment to Pulse Shape Discrimination has to be proposed in order to display a trustable count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a non-gadolinium loaded compensation scintillator solely interacts with the photon part of the incident radiation. Posterior to the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate after photon response compensation falls into statistical fluctuations or provides a robust image of a neutron activity. A laboratory prototype is tested under both photon and neutron irradiations, allowing us to investigate the performance of the overall compensation system in terms of neutron detection, especially with regards to a commercial helium-3 counter. The study reveals satisfactory results in terms of sensitivity and orientates future investigation toward promising axes. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of High Count Rate and Gain Shift on Isotope Identification Algorithms

Spectroscopic gamma-ray detectors are used for many research applications, as well as Homeland Security screening applications. Sodium iodide (NaI) scintillator crystals coupled with photomultiplier tubes (PMTs) provide medium-resolution spectral data about the surrounding environment. NaI based detectors, paired with spectral identification algorithms, are often effective in identifying sources of interest by isotope. However, intrinsic limitations exist for NaI systems because of gain shifts and spectral marring (e.g., loss of resolution and count-rate saturation) at high count rates. These effects are hardware dependent, and have strong effects on the radioisotopic identification capability of these systems. In this work, the effects of high count rate on the capability of isotope identification algorithms are explored. It is shown that a small gain shift of a few tens of keV is sufficient to disturb identification. The onset of this and other spectral effects are estimated for several systems., and a mechanism for mitigating these effects by estimating and correcting for them is implemented and evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-IeP4-12: Performance of In-111 Coincident Gamma-Ray Counting: A Monte Carlo Simulation

Purpose: The decay of In-111 results in a non-isotropic gamma-ray cascade, which is normally imaged using a gamma camera. Creating images with a gamma camera using coincident gamma-rays from In-111 has not been previously studied. Our objective was to explore the feasibility of imaging this cascade as coincidence events and to determine the optimal timing resolution and source activity using Monte Carlo simulations. Methods: GEANT4 was used to simulate the decay of the In-111 nucleus and to model the gamma camera. Each photon emission was assigned a timestamp, and the time delay and angular separation for the second gamma-ray in the cascade was consistent with the known intermediate state half-life of 85ns. The gamma-rays are transported through a model of a Siemens dual head Symbia “S” gamma camera with a 5/8-inch thick crystal and medium energy collimators. A true coincident event was defined as a single 171keV gamma-ray followed by a single 245keV gamma-ray within a specified time window (or vice versa). Several source activities (ranging from 10uCi to 5mCi) with and without incorporation of background counts were then simulated. Each simulation was analyzed using varying time windows to assess random events. The noise equivalent count rate (NECR) was computed based on the number of true and random counts for each combination of activity and time window. No scatter events were assumed since sources were simulated in air. Results: As expected, increasing the timing window increased the total number of observed coincidences albeit at the expense of true coincidences. A timing window range of 200–500ns maximizes the NECR at clinically-used source activities. The background rate did not significantly alter the maximum NECR. Conclusion: This work suggests coincident measurements of In-111 gamma-ray decay can be performed with commercial gamma cameras at clinically-relevant activities. Work is ongoing to assess useful clinical applications.

60 APPLIED LIFE SCIENCES↗

Single-Photon Counting in Luminescent Analysis with Micro- and Millisecond Decay Times

Main methods of photon counting, as well as particularities in detecting micro- and millisecond decay times using a single-photon gated avalanche photodiode, are considered. The influence of the background radiation level on linearity of counting has been determined and the effect of photon superposition during asynchronous counting has been demonstrated. In addition, recommendations for the detection of long-living or delayed fluorescence and phosphorescence are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the Accuscan II In Vivo System for I-125 Thyroid Counting

This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-125 thyroid counting. The source used for the calibration was a DOE manufactured Am-241/Eu-152 source contained in a 22 ml vial BEA Am-241/Eu-152 RMC II-1 with energies from 26 keV to 344 keV. The center of the detector housing was positioned 64 inches from the vault floor. This position places the approximate center line of the detector housing at the center line of the source in the phantom thyroid tube. The energy and efficiency calibration were performed using an RMC II phantom (Appendix J). Performance testing was conducted using source BEA Am-241/Eu-152 RMC II-1 and Validation testing was performed using an I-125 source in a 30 ml vial (I-125 BEA Thyroid 002) and an ANSI N44.3 phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-125 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calibration of the Accuscan II In Vivo System for I-131 Thyroid Counting

This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-131 thyroid counting. The source used for the calibration was an Analytics mixed gamma source 82834-121 distributed in an epoxy matrix in a Wheaton Liquid Scintillation Vial with energies from 88.0 keV to 1836.1 keV. The center of the detectors was position 64-feet from the vault floor. This position places the approximate center line of the detectors at the center line of the source in the thyroid tube. The calibration was performed using an RMC II phantom (Appendix J). Validation testing was performed using a Ba-133 source and an ANSI N44.3 Phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibrations including verification counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-131 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

B Counting at BaBar

In this thesis we examine the method of counting B{bar B} events produced in the BABAR experiment. The original method was proposed in 2000, but improvements to track reconstruction and our understanding of the detector since that date make it appropriate to revisit the B Counting method. We propose a new set of cuts designed to minimize the sensitivity to time-varying backgrounds. We find the new method counts B{bar B} events with an associated systematic uncertainty of {+-} 0.6%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A direct viable count method for the enumeration of attached bacteria and assessment of biofilm disinfection

This report describes the adaptation of an in situ direct viable count (in situ DVC) method in biofilm disinfection studies. The results obtained with this technique were compared to two other enumeration methods, the plate count (PC) and conventional direct viable count (c-DVC). An environmental isolate (Klebsiella pneumoniae Kp1) was used to form biofilms on stainless steel coupons in a stirred batch reactor. The in situ DVC method was applied to directly assess the viability of bacteria in biofilms without disturbing the integrity of the interfacial community. As additional advantages, the results were observed after 4 h instead of the 24 h incubation time required for colony formation and total cell numbers that remained on the substratum were enumerated. Chlorine and monochloramine were used to determine the susceptibilities of attached and planktonic bacteria to disinfection treatment using this novel analytical approach. The planktonic cells in the reactor showed no significant change in susceptibility to disinfectants during the period of biofilm formation. In addition, the attached cells did not reveal any more resistance to disinfection than planktonic cells. The disinfection studies of young biofilms indicated that 0.25 mg/l free chlorine (at pH 7.2) and 1 mg/l monochloramine (at pH 9.0) have comparable disinfection efficiencies at 25 degrees C. Although being a weaker disinfectant, monochloramine was more effective in removing attached bacteria from the substratum than free chlorine. The in situ DVC method always showed at least one log higher viable cell densities than the PC method, suggesting that the in situ DVC method is more efficient in the enumeration of biofilm bacteria. The results also indicated that the in situ DVC method can provide more accurate information regarding the cell numbers and viability of bacteria within biofilms following disinfection.

NASA Discipline Number 04-10↗

Update on Linear Mode Photon Counting with the HgCdTe Linear Mode Avalanche Photodiode

The behavior of the gain-voltage characteristic of the mid-wavelength infrared cutoff HgCdTe linear mode avalanche photodiode (e-APD) is discussed both experimentally and theoretically as a function of the width of the multiplication region. Data are shown that demonstrate a strong dependence of the gain at a given bias voltage on the width of the n− gain region. Geometrical and fundamental theoretical models are examined to explain this behavior. The geometrical model takes into account the gain-dependent optical fill factor of the cylindrical APD. The theoretical model is based on the ballistic ionization model being developed for the HgCdTe APD. It is concluded that the fundamental theoretical explanation is the dominant effect. A model is developed that combines both the geometrical and fundamental effects. The model also takes into account the effect of the varying multiplication width in the low bias region of the gain-voltage curve. It is concluded that the lower than expected gain seen in the first 2 × 8 HgCdTe linear mode photon counting APD arrays, and higher excess noise factor, was very likely due to the larger than typical multiplication region length in the photon counting APD pixel design. The implications of these effects on device photon counting performance are discussed.

HgCdTe↗