Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogenic cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Higher order mode analysis of a 915 MHz 2-cell cavity for a prototype industrial accelerator

A possible solution to reduce the complexity posed by the cryogenic systems in a superconducting RF accelerator for industrial applications, is to capitalize on the advances achieved by the Nb3Sn superconducting RF technology, as well as the feasibility of a reliable 4 K cooling system, based on commercial cryocoolers. Following this philosophy, the conceptual design for a prototype, conduction-cooled, 4 MeV, 20 kW SRF electron linac, is being developed at Jefferson Lab. Such design is based on a 915 MHz two-cell Nb3Sn cavity. In this contribution, we present the proposed cavity design, including the fundamental power coupler, and the analysis of the Higher Order Modes, using numerical simulations to estimate the potentially dangerous modes and to provide the requirements for damping for reliable operations with a cryocooler.

Rimmer, Robert↗

FGMS-poster

Idaho National Laboratory (INL) performs post irradiation examination (PIE) of tri-structural isotropic (TRISO)-coated particle fuel to help qualify it for high temperature gas cooled reactors. TRISO fuel compacts are re-irradiated in the Neutron Radiography Reactor (NRAD) to generate the short lived fission products needed for fission product release testing. The Fuel Accident Condition Simulator (FACS) furnace and newly added Screen Neutron Irradiated Fuel for Failure (SNIFF) furnace heat the compacts in helium to temperatures of up to 2,000°C, prompting fission product release—predominantly gaseous xenon and krypton isotopes and condensable products such as cesium—from failed particles. These released isotopes are transported to a fission gas monitoring system (FGMS 1 or FGMS 3), where they accumulate in cryogenic cold traps and are quantified using high-purity germanium (HPGe) detectors. The addition of SNIFF and FGMS 3 increases throughput by enabling simultaneous testing of multiple compacts. Furthermore, automated INL developed software provides continuous, near-real time monitoring of fission product inventories and manages the liquid nitrogen cooling of the traps. These system enhancements improve the efficiency, data quality, and testing capacity of TRISO fuel performance evaluations.

07 - ISOTOPES AND RADIATION SOURCES↗

Water-cooled Helmholtz coil for Ultra-low Magnetic Field Testing

Ultra-low magnetic field testing requires precise and finely calibrated instrumentation interacting with very marginal magnetic fields in highly controlled environments. We designed a large Helmholtz coil system for implementation around a 17.825-inch outer diameter Helium-3 Cryogenic fridge, to serve as both a field-zeroing device and to enable higher resolution on magnetic field sweeps during experiments. We present finite volume modeling and finite element analysis results which indicate the device could safely run at 20 [A] in perpetuity, producing a magnetic field of 65 [mT], without the surface facing the Cryogenic fridge exceeding 50°C. The overall system parts expense is $\$$4,882.76.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermoeconomic cost optimization of superconducting magnets for proton therapy gantries

A compact gantry delivering 70-220 MeV protons with fixed field in the superconducting magnets could reduce the cost and improve the adoption of proton therapy. While a number of magnet and cryogenics designs have been proposed, the combined capital and operating costs of state-of-the-art superconducting materials have not been analyzed. In response, we develop a thermoeconomic model of a multi-stage, conduction cooled gantry lattice and analyze the cryocooler operating cost, cryocooler capital cost and conductor capital cost for Nb-Ti, Nb 3 Sn, REBCO and Bi-2223 over a continuous range of magnet temperatures, and a differential evolution algorithm is used to identify the optimal combination of thermal intercept temperatures. Although Nb3Sn yields the lowest Net Present Value (NPV) of $111.7k at a magnet temperature of 9.4 K, the optimized Bi-2223 design at 12.8 K approaches the realm of commercial feasibility by offering improved thermal stability and forgoing the need for costly conductor heat treatment and magnet quench training. Furthermore, it was found that Nb3Sn was more cost effective than Nb-Ti and that REBCO was not economically viable for the parameters of this investigation. Overall, the thermoeconomic model developed herein can optimize conductor choices, magnet temperatures and thermal staging which has value for any conduction-cooled superconducting magnet.

BSCCO↗

Design and validation of a cold load for characterization of CMB-S4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three novel design features: (1) the ability to operate from the 1 K stage of a dilution refrigerator (DR), (2) a 3He gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150 GHz detector array previously deployed by the Spider experiment. Here, thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1 K stage. Additionally, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

47 OTHER INSTRUMENTATION↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

Nb$_{3}$Sn SRF Photogun High Power Test at Cryogenic Temperatures

Superconducting RF (SRF) photoguns are emerging as promising candidates to produce highly stable electrons for Ultra fast Electron Diffraction/Microscopy (EUD/UEM) applications due to the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb 3 Sn and conduction cooling. SRF gun can provide a CW operation capability while consuming only several Watts of RF power which eliminates the need of an expensive high power RF system and saves a facility footprint. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. Here, in this paper, we present first high power results of the gun covered with Nb 3 Sn.

43 PARTICLE ACCELERATORS↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

10 MWE CDCL Large Pilot Plant – pre-FEED Study

Coal Direct Chemical Looping (CDCL) is an advanced oxy-combustion technology that has the potential to substantially reduce the energy penalty and the cost of electricity (COE) for coal-fired power generation with CO₂ capture. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been collaborating on the development of an iron oxide oxygen-carrier based chemical looping technology for clean power generation with inherent carbon capture. In this process, coal is dried and pulverized prior to being transported into a moving-bed reducer. In the reducer, coal reacts with the oxygen-carrier particles, forming combustion byproducts, predominantly CO₂ and H₂O, while reducing the iron oxide oxidation state from Fe₂O₃ to a mixture of FeO and Fe. The reduced state particles are then transported to a combustor reactor and re-oxidized with air. Following the oxidation, the oxygen-carrier particles are regenerated, and a large amount of heat is released for steam production. The produced steam is sent to a turbine for electricity generation. Meanwhile, the CO₂–rich stream leaving the reducer is cooled, cleaned, and compressed for subsequent pipeline transportation and sequestration. By combining air separation and fuel conversion into a single system, the CDCL technology enables the intensification of oxy-combustion processes by eliminating the energy and cost intensive cryogenic air separation unit and thereby results in higher overall plant efficiencies and lower COE’s. The use of a moving-bed reducer results in high conversions of volatile hydrocarbons and high CO₂ purity, which reduces the cost of downstream CO₂ purification for sequestration or utilization. The Babcock & Wilcox Company in collaboration with The Ohio State University, Johnson & Matthey, The Electric Power Research Institute, and Dover Light & Power completed a Preliminary Front-End Engineering and Design (Pre-FEED) study of a 10 MWe coal-direct chemical looping (CDCL) pilot plant. The planned system is a modular 10 MWe CDCL large pilot facility consisting in 4 modules of 2.5 MWe each, working in parallel and to be hosted within the current structure at the City of Dover’s Municipal Power Plant. The CDCL system can achieve auto-thermal operation and includes a sub-critical steam cycle for power generation. The pilot system was designed to demonstrate full commercial operation at a reduced scale. The coal distribution per plan area is a representative slice of larger commercial arrangements. The system includes a CO₂ recycle system, but it does not include a compression system. The large pilot includes all the environmental control equipment and oxygen carrier and ash handling systems. As part of the project, the Team performed laboratory testing and carried out multiple pilot test campaigns to obtain design and performance information at the 250 kWth CDCL pilot facility at the Babcock & Wilcox Company’s Research Center. The Team demonstrated sustained operations at designed coal inputs, high coal conversion, high CO₂ purity, heat generation on the combustor, low carbon carryover between reactors and low particle attrition. Emissions generated in the reducer reactor were identified as SO₂ and NO x . The commercial manufacturing cost of oxygen carrier particle was evaluated by JM. A particle manufacturing report was generated and submitted to the DOE. Based on the results from the pilot tests and the pre-FEED design efforts, a techno-economic analysis was performed. The study shows that the CDCL process is a promising carbon-friendly technology capable of producing electricity with high efficiency. The estimated COE of the supercritical CDCL plant is $83.3 / MWh, which meets DOE’s target of less than 30% increase in COE when compared to a supercritical PC plant without CO₂ capture. This is the lowest among the existing carbon capture technologies (post-combustion and oxy-combustion) for fossil fuel power plant. CDCL is evaluated to be the most promising technology for carbon capture from the economic aspect.

01 COAL, LIGNITE, AND PEAT↗

A cryogenic white light absorption spectroscopy setup with in situ gamma irradiation and thermo-optical annealing for optical fiber radiation-induced attenuation characterization

Silica optical fiber sensors offer a fast, distributed measurement solution in various cryogenic and radiation environments, such as magnets for fusion power. Under these conditions, light-absorbing point defects limit lifetime via radiation-induced attenuation (RIA). To support RIA kinetics prediction, we present an in situ, broadband absorption spectroscopy setup combining gamma irradiation with liquid nitrogen cooling. The apparatus enables continuous monitoring of narrowband RIA levels and the use of secondary optical annealing light sources, alongside broadband spectrum measurements to characterize RIA defects through spectrum decomposition. Initial results confirm the inevitable photobleaching effect of the probe light source, which must be accounted for. In addition, we report RIA kinetics during cycles of gamma irradiation at 77 K and isochronal thermal annealing steps from liquid nitrogen to room temperature, showcasing the setup’s ability to replicate real fiber operation scenarios. These instruments form an ideal platform to further study the kinetics of RIA coupled with thermal and optical annealing.

Absorption spectroscopy↗

Near-Monochromatic Tuneable Cryogenic Niobium Electron Field Emitter

We report creating, manipulating, and detecting coherent electrons is at the heart of future quantum microscopy and spectroscopy technologies. Leveraging and specifically altering the quantum features of an electron beam source at low temperatures can enhance its emission properties. Here, we describe electron field emission from a monocrystalline, superconducting niobium nanotip at a temperature of 5.9 K. The emitted electron energy spectrum reveals an ultranarrow distribution down to 16 meV due to tunable resonant tunneling field emission via localized band states at a nanoprotrusion’s apex and a cutoff at the sharp low-temperature Fermi edge. This is an order of magnitude lower than for conventional field emission electron sources. The self-focusing geometry of the tip leads to emission in an angle of 3.7°, a reduced brightness of 3.8 × 10 8 A/(m 2 srV), and a stability of hours at 4.1 nA beam current and 69 meV energy width. This source will decrease the impact of lens aberration and enable new modes in low-energy electron microscopy, electron energy loss spectroscopy, and high-resolution vibrational spectroscopy.

36 MATERIALS SCIENCE↗

High photon-phonon pair generation rate in a two-dimensional optomechanical crystal

Integrated optomechanical systems are a leading platform for manipulating, sensing, and distributing quantum information, but are limited by residual optical heating. Here, we demonstrate a two-dimensional optomechanical crystal (OMC) geometry with increased thermal anchoring and a mechanical mode at 7.4 GHz, well aligned with the operation range of cryogenic microwave hardware and piezoelectric transducers. The eight times better thermalization than current one-dimensional OMCs, large optomechanical coupling rates, g 0 /2π ≈ 880 kHz, and high optical quality factors, Q opt = 2.4 × 10 5 , allow ground-state cooling (n m = 0.32) of the acoustic mode from 3 K and entering the optomechanical strong-coupling regime. In pulsed sideband asymmetry measurements, we show ground-state operation (n m < 0.45) at temperatures below 10 mK, with repetition rates up to 3 MHz, generating photon-phonon pairs at ≈ 147 kHz. Our results extend optomechanical system capabilities and establish a robust foundation for future microwave-to-optical transducers with entanglement rates exceeding state-of-the-art superconducting qubit decoherence rates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lattice response to ambient self-irradiation of δ-phase 239 Pu-Ga alloys exposed to cryogenic temperatures

Self-irradiation in plutonium is a continuous process that introduces radiation damage ranging from point defects to nanoscale radiation damage as well as decay daughter product impurities that require to be accommodated by the host material. These changes are affecting the structure and properties of the material by lattice swelling, mechanical strengthening, and other alterations. X-ray diffraction and dilatometry studies have shown that the room temperature self-irradiation of δ-phase Pu-Ga alloys (2 and 7 at%Ga) results in swelling of the lattice that saturates after 0.1–0.2 displacement per atom (dpa) of accumulated lattice damage. Here, for a better understanding of these self- irradiation processes, defect accumulation and damage evolution, this time-of-flight neutron diffraction study investigates the impact of ambient self-irradiation effects on the structural evolution of δ-phase 239 Pu-Ga alloys exposed to cryogenic temperatures (<120 K), associated with a varied history of storage time and thermal treatments. Two key behaviors were observed in the lattice evolution after exposure to cryogenic temperatures with respect to room-temperature accumulated self-irradiation damage. Samples with no self- irradiation damage accumulation under ambient conditions showed swelling of the lattice at the end of the measurement, while samples that accumulated significant self-irradiation damage under ambient conditions showed only a partial recovery of the lattice parameter value upon completion of the measurements (cooling followed by heating back to room temperature). Possible causes of the behavior are proposed, and their associated effects are discussed.

36 MATERIALS SCIENCE↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

Conjugate Multimode Heat Transfer Analysis of Cryogenic EXLO Manipulation

Abstract In this study, a conjugate radiation/conduction multimode heat transfer analysis of cryogenic focused ion beam (FIB) milling steps necessary for producing ex situ lift out specimens under cryogenic conditions (cryo-EXLO) is performed. Using finite volume for transient heat conduction and enclosure theory for radiation heat transfer, the analysis shows that as long as the specimen is attached or touching the FIB side wall trenches, the specimen will remain vitreous indefinitely, while actively cooled at liquid nitrogen (LN2) temperatures. To simulate the time needed to perform a transfer step to move the bulk sample containing the FIB-thinned specimen from the cryo-FIB to the cryo-EXLO cryostat, the LN2 temperature active cooling is turned off after steady-state conditions are reached and the specimen is monitored over time until the critical devitrification temperature is reached. Under these conditions, the sample will remain vitreous for >3 min, which is more than enough time needed to perform the cryo-transfer step from the FIB to the cryostat, which takes only ∼10 s. Cryo-transmission electron microscopy images of a manipulated cryo-EXLO yeast specimen prepared with cryo-FIB corroborates the heat transfer analysis.

Materials Science↗

High resolution diagnostic tools for superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 –10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two high-resolution diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system, which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. This setup has a spatial resolution of ~ 13 μm in the azimuthal direction and ~ 1 cm along the cavity contour. The second setup is a stationary, combined magnetic and temperature mapping system, which uses anisotropic magnetoresistance sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. This system has a spatial resolution of 5 mm close to the iris and 11 mm at the equator. Initial results show a non-uniform distribution of trapped flux on the cavities’ surfaces, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THERMAL/STRUCTURAL ANALYSIS OF THE AXION QUANTUM METROLOGY CAVITY AND ITS COMPONENTS

This research was centered around maximizing the capability to cool dielectric material within a containment unit, or Photonic Band Gap (PBG) cavity, designed for detecting axion dark matter and identifying the unit’s thermal properties. There are multiple types of PBG cavities, but the latest version that axion researchers wish to use has been theorized to contain possible issues related to its thermal properties. Thermal conductivity is an issue with the dielectric material because it is made from alumina which is highly insulative. This is important since the research is being done in a cryogenic environment and the thermal noise affects the quantum bit used for detecting the axion to photon conversion process. Therefore, any improvements to this unit should be justified and implemented but are not entirely limited to thermal contact related aspects of PBG cavities. A prospect of using sapphire in place of alumina also exists, but this is a more expensive, less tested, and more elusive material to justify the creation of a full dielectric structure out of sapphire. Thermal aspects of the cavity were analyzed using finite element method (FEM) and an experiment designed to test different thermal joint materials. FEM was used to check the contraction of the cavity during cooling, the contact quality between the dielectric material and cavity wall, theheat flow rate through the assembly, and helps visualize the cavity’s reaction to different design changes. A simple comparison between thermal conductivity curves justified the usage of sapphire over alumina from a thermal property point of view. Thus, the method of experimentation had an additional dielectric material, sapphire, to test with and compare to alumina. The thermal test identified which material is best to use for a thermal joint but also simultaneously found the conductance of the joint and dielectric material as well as an estimate for what the temperature is inside the larger scale cavity since a thermometer cannot be placed inside the PBG when it cools. Initially, the cavity simulation was tested for structural deformation properties and stress distribution since it is made of copper which contracts heavily in comparison to most other materials. The reduction in volume of the cavity was less than anticipated which gave more room for a possible usage of a modified thermal joint for additional contact area and higher conductivity.

43 PARTICLE ACCELERATORS↗